Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39120125

RESUMO

The presence of residual undifferentiated pluripotent stem cells (PSCs) in PSC-derived cell therapy products (CTPs) is a major safety issue for their clinical application, due to the potential risk of PSC-derived tumor formation. An international multidisciplinary multisite study to evaluate a droplet digital PCR (ddPCR) approach to detect residual undifferentiated PSCs in PSC-derived CTPs was conducted as part of the Health and Environmental Sciences Institute Cell Therapy-TRAcking, Circulation & Safety Technical Committee. To evaluate the use of ddPCR in quantifying residual iPSCs in a cell sample, different quantities of induced pluripotent stem cells (iPSCs) were spiked into a background of iPSC-derived cardiomyocytes (CMs) to mimic different concentrations of residual iPSCs. A one step reverse transcription ddPCR (RT-ddPCR) was performed to measure mRNA levels of several iPSC-specific markers and to evaluate the assay performance (precision, sensitivity, and specificity) between and within laboratories. The RT-ddPCR assay variability was initially assessed by measuring the same RNA samples across all participating facilities. Subsequently, each facility independently conducted the entire process, incorporating the spiking step, to discern the parameters influencing potential variability. Our results show that a RT-ddPCR assay targeting ESRG, LINC00678, and LIN28A genes offers a highly sensitive and robust detection of impurities of iPSC-derived CMs and that the main contribution to variability between laboratories is the iPSC-spiking procedure, and not the RT-ddPCR. The RT-ddPCR assay would be generally applicable for tumorigenicity evaluation of PSC-derived CTPs with appropriate marker genes suitable for each CTP.

2.
Fam Med ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39012289

RESUMO

BACKGROUND AND OBJECTIVES: Assessing suicide risk in primary care settings has become standard practice; however, the emotional toll on medical providers remains understudied. This qualitative study examines the emotional impact of suicide assessments among family medicine residents. METHODS: We conducted one-on-one, semistructured, in-depth interviews with a convenience sample of residents enrolled in a family medicine residency program at a US military installation. Employing an exploratory, qualitative research approach, we iteratively coded transcribed interviews for content and themes. RESULTS: For this study, we interviewed 15 family medicine residents spanning all three postgraduate year groups. The primary objective of the comprehensive study was to evaluate the confidence levels of family medicine residents in suicide risk screening, with the intent to identify educational gaps for improvement. However, unexpectedly, participants revealed their profound negative emotional responses during these assessments. The emotional impact of suicide risk assessment was the most frequently coded theme in the study, with participants noting six main emotional reactions to assessing suicide risk among their patients: fear, weariness, anxiety, shock, overwhelm, and inadequacy. CONCLUSIONS: Despite claims of emotional detachment, participants often expressed surprise and vulnerability when faced with suicidal patients. With suicide screening becoming increasingly vital in primary care, understanding and mitigating the emotional impact on physicians is essential. Future research should explore strategies to support medical providers in navigating these challenging interactions effectively for both the patients and themselves.

3.
Opt Express ; 32(12): 21783-21794, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38859524

RESUMO

We study the interaction of a laser cavity-soliton microcomb with an externally coupled, co-propagating tunable CW pump, observing parametric Kerr interactions which lead to the formation of both a cross-phase modulation and a four-wave mixing replica of the laser cavity-soliton. We compare and explain the dependence of the microcomb spectra from both the cavity-soliton and pump parameters, demonstrating the ability to adjust the microcomb externally without breaking or interfering with the soliton state. The parametric nature of the process agrees with numerical simulations. The parametric extended state maintains the typical robustness of laser-cavity solitons.

4.
Adv Mater ; 36(31): e2403659, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38843445

RESUMO

On-chip integration of 2D materials with unique structures and properties endow integrated devices with new functionalities and improved performance. With high flexibility in ways to modify its properties and compatibility with integrated platforms, graphene oxide (GO) is an exceptionally attractive 2D material for hybrid integrated photonic chips. Here, by harnessing unique property changes induced by photothermal effects in 2D GO films, novel functionalities beyond the capability of photonic integrated circuits are demonstrated. These include all-optical control and tuning, optical power limiting, and nonreciprocal light transmission. The 2D layered GO films are integrated onto photonic chips with precise control of their thickness and size. Benefitting from the broadband optical response of 2D GO films, all three functionalities feature a very wide operational optical bandwidth. By fitting the experimental results with theory, the changes in GO film properties induced by the photothermal effects are analyzed, revealing interesting insights about the physics of 2D GO films. These results highlight the versatility of 2D GO films in implementing new functions for integrated photonic devices for a wide range of applications.

5.
Opt Express ; 32(7): 11281-11295, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38570979

RESUMO

We report a dual-polarization radio frequency (RF) channelizer based on microcombs. Two high-Q micro-ring resonators (MRRs) with slightly different free spectral ranges (FSRs) are used: one MRR is pumped to yield soliton crystal microcombs ("active"), and the other MRR is used as a "passive" periodic optical filter supporting dual-polarization operation to slice the RF spectrum. With the tailored mismatch between the FSRs of the active and passive MRRs, wideband RF spectra can be channelized into multiple segments featuring digital-compatible bandwidths via the Vernier effect. Due to the use of dual-polarization states, the number of channelized spectral segments, and thus the RF instantaneous bandwidth (with a certain spectral resolution), can be doubled. In our experiments, we used 20 microcomb lines with ∼ 49 GHz FSR to achieve 20 channels for each polarization, with high RF spectra slicing resolutions at 144 MHz (TE) and 163 MHz (TM), respectively; achieving an instantaneous RF operation bandwidth of 3.1 GHz (TE) and 2.2 GHz (TM). Our approach paves the path towards monolithically integrated photonic RF receivers (the key components - active and passive MRRs are all fabricated on the same platform) with reduced complexity, size, and unprecedented performance, which is important for wide RF applications with digital-compatible signal detection.

6.
Clin Gerontol ; 47(1): 78-89, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-36732317

RESUMO

OBJECTIVES: Dementia caregivers (CGs) are at heightened risk for developing problems with anxiety and depression. Much attention has been directed toward developing and deploying interventions designed to protect CG health, but few have been supported by rigorous empirical evidence. Technology-based interventions that are effective, scalable, and do not add greatly to the CG burden are of particular interest. METHODS: We conducted a nine-month randomized controlled trial in 63 homes evaluating People Power Caregiver (PPCg), a system of sensors in the home connected to cloud-based software that alerts CGs about worrisome deviations from normal patterns (e.g., falls, wandering). RESULTS: CGs in the active condition had significantly less anxiety than those in the control condition at the six-month assessment. Greater anxiety reduction in the active condition at the six-month assessment was associated with greater interaction with PPCg via SMS text messages. There were no differences in anxiety at the three-month or nine-month assessments or in depression at any assessment. CONCLUSIONS: PPCg shows promise for reducing anxiety associated with caring for a =person with dementia. CLINICAL IMPLICATIONS: Technology-based interventions can help reduce CG anxiety, a major adverse consequence of caregiving that may be difficult to treat due to other demands on caregiver time and energy.


Assuntos
Demência , Tecnologia Assistiva , Humanos , Cuidadores , Demência/terapia , Ansiedade/terapia , Transtornos de Ansiedade
7.
Sensors (Basel) ; 23(24)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38139613

RESUMO

The engineering of thermo-optic effects has found broad applications in integrated photonic devices, facilitating efficient light manipulation to achieve various functionalities. Here, we perform both an experimental characterization and a theoretical analysis of these effects in integrated microring resonators made from high-index doped silica, which have had many applications in integrated photonics and nonlinear optics. By fitting the experimental results with theory, we obtain fundamental parameters that characterize their thermo-optic performance, including the thermo-optic coefficient, the efficiency of the optically induced thermo-optic process, and the thermal conductivity. The characteristics of these parameters are compared to those of other materials commonly used for integrated photonic platforms, such as silicon, silicon nitride, and silica. These results offer a comprehensive insight into the thermo-optic properties of doped silica-based devices. Understanding these properties is essential for efficiently controlling and engineering them in many practical applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA