RESUMO
BACKGROUND: Magnetic resonance (MR) imaging is the most common modality for assessment of the rotator cuff before and after surgery. Several classifications have been described aiming to define main tear characteristics. However, there is still confusion when it comes to the reliability of those classifications. PURPOSE: (1) To identify all MR classifications available in the literature for preoperative assessment of rotator cuff tears, (2) to summarize available data on the reliability of identified classifications, and (3) to assess the methodological quality of reliability studies. STUDY DESIGN: Systematic review; Level of evidence, 4. METHODS: This systematic review was conducted following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. All studies reporting MR assessment in patients with a superior or posterosuperior rotator cuff tear were included. After identification of the available MR criteria, reliability studies were analyzed. Descriptive statistics were used to summarize findings. Methodological quality was assessed using the Quality Appraisal of Reliability Studies checklist. RESULTS: A total of 75 studies were included in this review. Eight categories of outcomes could be identified. Of the total, 62 studies reported interobserver reliability whereas 32 reported intraobserver reliability of some of the identified criteria. Each category reflected a variety of reliability, ranging from poor to excellent agreement. MR proved to be a reliable imaging modality to detect the structural integrity of the posterosuperior cuff, especially in cases of full-thickness tear; it was also reliable in terms of tear width and length and muscle atrophy based on a tangent sign or Thomazeau classification. All other classifications did not prove acceptable reliability. Methodological quality was high for 23 articles and moderate for 14. CONCLUSION: Preoperative MR is a reliable imaging modality to identify full-thickness tears, measure tear size and morphology, and identify muscle atrophy with tangent sign or Thomazeau classification. All other outcomes and classifications did not show acceptable reliability; therefore, caution is needed when using them for preoperative evaluation of a rotator cuff tear.
Assuntos
Lacerações , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/diagnóstico por imagem , Lesões do Manguito Rotador/cirurgia , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética , Atrofia MuscularRESUMO
PURPOSE: Although many arthrometers have been developed to assess anterior knee laxity, reliability and diagnostic accuracy of these devices are still debated. The aim of the present study was to evaluate the validity of a new arthrometer in the outpatient setting, with the hypothesis that it had good validity in terms of reliability and diagnostic accuracy. METHODS: Seventy-eight subjects (39 with ACL injury and 39 with normal ACL) were tested. ATT was assessed by means of the Lachman test at 30° of flexion with a new testing device (BLU-DAT) under three different loading conditions: 7 kg (69 N), 9 kg (88 N) and maximum (MMT). The tests were performed on both knees to obtain SSD. In the ACL injury group, the tests were performed by two examiners and one of them repeated a second test series. Inter- and intra-observer reliability were assessed with the intraclass correlation coefficients (ICCs) for the average SSD measures. In the normal-ACL group, the analysis was performed with the same testing setup. Side-to-side difference measures of the two groups at every loading condition were compared by Student's t test. Data of test series were dichotomized based on the threshold value of 3-mm SSD as pathological ATT and 2 × 2 contingency tables were used to assess diagnostic accuracy. RESULTS: The ICCs for intra-observer reliability at 7-kg (69 N), 9-kg (88 N) and MMT measurements were 0.781, 0.855 and 0.913, respectively. The ICC for inter-observer reliability at 7-kg (69 N), 9-kg (88 N) and MMT measurements were 0.701, 0.845 and 0.834, respectively. Comparison between the two groups showed a significant mean difference ranging from 3.4 mm for 7-kg (69 N) load to 4.6 mm for MMT. Overall accuracy ranged from 84.6% for 7-kg load to 98.7% for MMT. CONCLUSION: The BLU-DAT has proven to be an instrument with good intra- and inter-observer reliability and very good accuracy in the diagnosis of ACL injuries in the outpatient setting. So, the BLU-DAT can be a new useful tool in everyday clinical practice to assist in the diagnosis of ACL injury. LEVEL OF EVIDENCE: II.
Assuntos
Lesões do Ligamento Cruzado Anterior , Instabilidade Articular , Humanos , Lesões do Ligamento Cruzado Anterior/diagnóstico , Reprodutibilidade dos Testes , Articulação do Joelho , Amplitude de Movimento Articular , Exame Físico , Instabilidade Articular/diagnóstico , Fenômenos BiomecânicosRESUMO
Primary or revision irreparable rotator cuff tears remain a challenge. Clear algorithms do not exist. Several joint-preserving options are available, but no technique has been definitely proven to be better than another. Although superior capsule reconstruction has been shown to be effective in restoring motion, lower trapezius transfer can provide strong external rotation and abduction moment. The aim of the present article was to describe an easy and reliable technique to combine both options in 1 surgery, aiming to maximize the functional outcome by getting motion and strength back.
RESUMO
PURPOSE: To describe the surgical technique and the outcome of a case series of nonunion and malunion of distal femur fractures treated with an endosteal medial plate combined with a lateral locking plate and with autogenous bone grafting. METHODS: We retrospectively analyzed a series of patients with malunion or nonunion of the distal femur treated with a medial endosteal plate in combination with a lateral locking plate, in a period between January 2011 and December 2019, Database from chart review was obtained including all the clinical relevant available baseline data (demographics, type of fracture, mechanism of injury, time from injury to surgery, number of previous surgical procedures, type of bone graft, and type of lateral plate). Time to bone healing, limb alignment at follow-up and complications were documented. RESULTS: Ten patients were included into the study: 7 male and 3 female with mean age of 48.3 years (range 21-67). The mechanism of trauma was in 8 cases a road traffic accident and in 2 cases a fall from height. According to AO/OTA classification 5 fractures were 33 A3, 3 were 33 C1, 1 was 33 C2 and 1 was 33 C3. The average follow up was 13.5 months. In all cases but one bony union was achieved. Bone healing was observed in average 3.3 months after surgery. No intraoperative or postoperative complications were reported. CONCLUSION: A medial endosteal plate is a useful augmentation for lateral plate fixation in nonunion or malunion following distal femur fractures, particularly in cases of medial bone loss, severe comminution, or poor bone quality. LEVEL OF EVIDENCE: Level IV (retrospective case series).
Assuntos
Fraturas Femorais Distais , Fraturas do Fêmur , Humanos , Masculino , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Placas Ósseas , Resultado do Tratamento , Consolidação da FraturaRESUMO
INTRODUCTION: For several years, many arthrometers have been developed to assess anterior knee laxity. The aim of our study was to evaluate the validity of a new practical and handy testing device with the hypothesis that the new arthrometer had good validity in terms of reliability and accuracy. METHODS: Lachman test was performed on five fresh frozen cadaveric knees by five examiners. Anterior tibial translation (ATT) was measured with a new arthrometer (BLU-DAT) and on lateral stress radiographs. Data on ATT were obtained under 7 kg (69 N), 9 kg (88 N), and maximum manual traction (MMT). Tests were performed on the same specimens before and after arthroscopic ACL excision. Inter-rater reliability of the BLU-DAT measures was assessed with the intraclass correlation coefficient (ICC) for single and average measurements. The Bland-Altman method was used to estimate agreement between the BLU-DAT and stress radiographs. RESULTS: ICC values for single measurements were 0.62, 0.54 and 0.58 for 7-kg, 9-kg and MMT assessment, respectively. Overall reliability was good (ICC = 0.63). ICC values for average measurements were 0.89, 0.85 and 0.88 for 7-kg, 9-kg and MMT assessment, respectively. Overall reliability was very good (ICC = 0.90) SEM ranged from 1.4 mm to 1.6 mm for single measurements and was below 1 mm at each testing condition for average measurements. Analysis of agreement between BLU-DAT and radiographic measurements showed a mean difference equal to 0.83 mm ± 2.1 mm (95% CI: 0.55-1.11). Upper LOA was equal to 4.9 mm (95% CI: 5.39-4.41). Lower LOA was equal to - 3.2 mm (95% CI: - 2.71 to - 3.69). CONCLUSION: Measurement of anterior knee laxity with the BLU-DAT testing device has a good to very good inter-rater reliability and good agreement with a gold standard such as stress radiographs. Cadaveric Diagnostic Study, Level of Evidence IV.
Assuntos
Lesões do Ligamento Cruzado Anterior , Instabilidade Articular , Humanos , Reprodutibilidade dos Testes , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Joelho/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , CadáverRESUMO
PURPOSE: To compare the clinical outcome of arthroscopic capsulolabral repair for traumatic anterior shoulder instability with PEEK knotless and knotted biodegradable suture anchors. METHODS: Arthroscopic stabilization was performed in 78 patients with recurrent traumatic anterior shoulder instability. They were divided into 2 groups of 39 patients each, according to suture anchors used: knotless PEEK anchors in group 1, and biodegradable anchors in group 2. Exclusion criteria were: instability without dislocation, posterior or multidirectional instability, glenoid bone loss > 20%, off-track lesions, concomitant rotator cuff tears and previous surgery. The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) self-administered questionnaire. Secondary outcomes were: Work-DASH, Sport-DASH, Rowe score, recurrent instability and subsequent surgery. The following independent variables were considered: age, gender, dominance, generalized ligamentous hyperlaxity, duration of symptoms, age at first dislocation, number of dislocations, type of work, type of sport, sports activity level, capsule-labral injury pattern, SLAP lesion and number of anchors. Differences between groups for numerical variables were analyzed by use of the Student's t-test or Mann-Whitney U-test. Fisher's exact test was used for analysis of categorical variables. Significance was set at p < 0.05. RESULTS: Seven patients (9%) were lost at follow-up, 5 from group 1 and 2 from group 2. Follow-up ranged from 36 to 60 months (median: 44; IQR: 13). Comparison between groups did not show significant differences for each independent variable considered. No differences could be found either for DASH (n.s.) or Rowe (p = n.s.) scores between the two groups. Overall recurrence rate was 7%. Three re-dislocations were reported in group 1 and two in group 2 (n.s.). Only one patient in each group underwent re-operation. CONCLUSIONS: The study showed no significant differences in clinical outcomes after arthroscopic treatment of traumatic anterior shoulder instability using PEEK knotless or biodegradable knotted anchors at mid-term follow-up. LEVEL OF EVIDENCE: I.
Assuntos
Luxações Articulares , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Artroscopia , Benzofenonas , Humanos , Luxações Articulares/complicações , Instabilidade Articular/complicações , Instabilidade Articular/cirurgia , Polímeros , Estudos Prospectivos , Recidiva , Ombro , Luxação do Ombro/complicações , Luxação do Ombro/cirurgia , Articulação do Ombro/cirurgia , Âncoras de Sutura , Resultado do TratamentoRESUMO
The aim of the present study was to present clinical and radiological outcome of a hip fracture-dislocation of the femoral head treated with biomimetic osteochondral scaffold.An 18-year-old male was admitted to the hospital after a motorcycle-accident. He presented with an obturator hip dislocation with a type IVA femoral head fracture according to Brumback classification system. The patient underwent surgery 5 days after accident. The largest osteochondral fragment was reduced and stabilized with 2 screws, and the small fragments were removed. The residual osteochondral area was replaced by a biomimetic nanostructured osteochondral scaffold. At 1-year follow-up the patient did not complain of hip pain and could walk without limp. At 2-year follow-up he was able to run with no pain and he returned to practice sports. Repeated radiographs and magnetic resonance imaging studies of the hip showed no signs of osteoarthritis or evidence of avascular necrosis. A hyaline-like signal on the surface of the scaffold was observed with restoration of the articular surface and progressive decrease of the subchondral edema.The results of the present study showed that the biomimetic nanostructured osteochondral scaffold could be a promising and safe option for the treatment of traumatic osteochondral lesions of the femoral head.Study Design: Case report.