Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Imaging ; 113: 110235, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39059085

RESUMO

OBJECTIVE: This study aims to assess the efficacy of polyenergetic reconstruction methods in reducing streak artifacts caused by dual source imaging in Photon Counting Detector Computed Tomography (PCD-CT) imaging, thereby improving image quality and diagnostic accuracy. METHODS: A retrospective cohort study was conducted, involving 50 patients who underwent chest Computed Tomography Angiography with PCD-CT, focusing on those with streak artifacts. Quantitative and qualitative analyses were performed on images reconstructed using monoenergetic and polyenergetic techniques. Quantitative evaluations measured the attenuation of tracheal air density in regions affected by streak artifacts, while qualitative assessments employed a modified Likert scale to rate image quality. Statistical analyses included Wilcoxon's signed-rank tests and Spearman's correlation, alongside assessments of inter-rater reliability. RESULTS: There was significantly lower attenuation of tracheal air density on the polyenergetic reconstructions (Median - 1010 ± 62 HU vs -930 ± 110 HU; P < 0.001), and significantly decreased variation on the polyenergetic reconstructions (Median 65.2 ± 79.5 HU vs 38.8 ± 33.9 HU; P < 0.001). The median modified-Likert scale were significantly better for the polyenergetic reconstructions (median modified-Likert 4 ± 0.5 vs 2.5 ± 1; P < 0.001). The inter-rater agreement was substantial and not significantly different between reconstructions (Gwet's ACPolyenergetic = 0.78 vs Gwet's ACVMI = 0.775). CONCLUSION: Polyenergetic reconstruction significantly mitigates streak artifacts in PCD-CT imaging, enhancing quantitative and qualitative image quality. This advancement addresses a known limitation of current PCD-CT reconstruction techniques, offering a promising approach to improving diagnostic reliability and accuracy in clinical practice. We demonstrate that future software implementations can resolve this artifact.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38717723

RESUMO

PURPOSE: In 2021, the United States Preventive Services Task Force (USPSTF) revised their 2013 recommendations for lung cancer screening eligibility by lowering the pack-year history from 30+ to 20+ pack-years and the recommended age from 55 to 50 years. Simulation studies suggest that Black persons and females will benefit most from these changes, but it is unclear how the revised USPSTF recommendations will impact geographic, health-related, and other sociodemographic characteristics of those eligible. METHODS: This cross-sectional study employed data from the 2017-2020 Behavioral Risk Factor Surveillance System surveys from 23 states to compare age, gender, race, marital, sexual orientation, education, employment, comorbidity, vaccination, region, and rurality characteristics of the eligible population according to the original 2013 USPSTF recommendations with the revised 2021 USPSTF recommendations using chi-squared tests. This study compared those originally eligible to those newly eligible using the BRFSS raking-dervived weighting variable. RESULTS: There were 30,190 study participants. The results of this study found that eligibility increased by 62.4% due to the revised recommendations. We found that the recommendation changes increased the proportion of eligible females (50.1% vs 44.1%), Black persons (9.2% vs 6.6%), Hispanic persons (4.4% vs 2.7%), persons aged 55-64 (55.8% vs 52.6%), urban-dwellers(88.3% vs 85.9%), unmarried (3.4% vs 2.5%) and never married (10.4% vs 6.6%) persons, as well as non-retirees (76.5% vs 56.1%) Respondents without comorbidities and COPD also increased. CONCLUSION: It is estimated that the revision of the lung cancer screening recommendations decreased eligibility disparities in sex, race, ethnicity, marital status, respiratory comorbidities, and vaccination status. Research will be necessary to estimate whether uptake patterns subsequently follow the expanded eligibility patterns.

3.
Pol J Radiol ; 89: e63-e69, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38371894

RESUMO

Purpose: Computed tomography (CT) pulmonary angiography is considered the gold standard for pulmonary embolism (PE) diagnosis, relying on the discrimination between contrast and embolus. Photon-counting detector CT (PCD-CT) generates monoenergetic reconstructions through energy-resolved detection. Virtual monoenergetic images (VMI) at low keV can be used to improve pulmonary artery opacification. While studies have assessed VMI for PE diagnosis on dual-energy CT (DECT), there is a lack of literature on optimal settings for PCD-CT-PE reconstructions, warranting further investigation. Material and methods: Twenty-five sequential patients who underwent PCD-CT pulmonary angiography for suspicion of acute PE were retrospectively included in this study. Quantitative metrics including signal-to-noise ratio (SNR) and contrast-to-noise (CNR) ratio were calculated for 4 VMI values (40, 60, 80, and 100 keV). Qualitative measures of diagnostic quality were obtained for proximal to distal pulmonary artery branches by 2 cardiothoracic radiologists using a 5-point modified Likert scale. Results: SNR and CNR were highest for the 40 keV VMI (49.3 ± 22.2 and 48.2 ± 22.1, respectively) and were inversely related to monoenergetic keV. Qualitatively, 40 and 60 keV both exhibited excellent diagnostic quality (mean main pulmonary artery: 5.0 ± 0 and 5.0 ± 0; subsegmental pulmonary arteries 4.9 ± 0.1 and 4.9 ± 0.1, respectively) while distal segments at high (80-100) keVs had worse quality. Conclusions: 40 keV was the best individual VMI for the detection of pulmonary embolism by quantitative metrics. Qualitatively, 40-60 keV reconstructions may be used without a significant decrease in subjective quality. VMIs at higher keV lead to reduced opacification of the distal pulmonary arteries, resulting in decreased image quality.

4.
Emerg Radiol ; 31(1): 73-82, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224366

RESUMO

PURPOSE: Acute chest syndrome (ACS) is secondary to occlusion of the pulmonary vasculature and a potentially life-threatening complication of sickle cell disease (SCD). Dual-energy CT (DECT) iodine perfusion map reconstructions can provide a method to visualize and quantify the extent of pulmonary microthrombi. METHODS: A total of 102 patients with sickle cell disease who underwent DECT CTPA with perfusion were retrospectively identified. The presence or absence of airspace opacities, segmental perfusion defects, and acute or chronic pulmonary emboli was noted. The number of segmental perfusion defects between patients with and without acute chest syndrome was compared. Sub-analyses were performed to investigate robustness. RESULTS: Of the 102 patients, 68 were clinically determined to not have ACS and 34 were determined to have ACS by clinical criteria. Of the patients with ACS, 82.4% were found to have perfusion defects with a median of 2 perfusion defects per patient. The presence of any or new perfusion defects was significantly associated with the diagnosis of ACS (P = 0.005 and < 0.001, respectively). Excluding patients with pulmonary embolism, 79% of patients with ACS had old or new perfusion defects, and the specificity for new perfusion defects was 87%, higher than consolidation/ground glass opacities (80%). CONCLUSION: DECT iodine map has the capability to depict microthrombi as perfusion defects. The presence of segmental perfusion defects on dual-energy CT maps was found to be associated with ACS with potential for improved specificity and reclassification.


Assuntos
Síndrome Torácica Aguda , Anemia Falciforme , Iodo , Embolia Pulmonar , Humanos , Síndrome Torácica Aguda/diagnóstico por imagem , Estudos Retrospectivos , Angiografia/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Pulmão , Embolia Pulmonar/diagnóstico por imagem , Anemia Falciforme/complicações , Anemia Falciforme/diagnóstico por imagem , Perfusão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA