Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 11(1)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38247957

RESUMO

The growing interest in advancing microfluidic devices for manipulating fluids within micrometer-scale channels has prompted a shift in manufacturing practices, moving from single-component production to medium-size batches. This transition arises due to the impracticality of lab-scale manufacturing methods in accommodating the increased demand. This experimental study focuses on the design of master benchmarks 1-5, taking into consideration critical parameters such as rib width, height, and the relative width-to-height ratio. Notably, benchmarks 4 and 5 featured ribs that were strategically connected to the inlet, outlet, and reaction chamber of the master, enhancing their utility for subsequent replica production. Vat photopolymerization was employed for the fabrication of benchmarks 1-5, while replicas of benchmarks 4 and 5 were generated through polydimethylsiloxane casting. Dimensional investigations of the ribs and channels in both the master benchmarks and replicas were conducted using an optical technique validated through readability analysis based on the Michelson global contrast index. The primary goal was to evaluate the potential applicability of vat photopolymerization technology for efficiently producing microfluidic devices through a streamlined production process. Results indicate that the combination of vat photopolymerization followed by replication is well suited for achieving a minimum rib size of 25 µm in width and an aspect ratio of 1:12 for the master benchmark.

2.
Bioengineering (Basel) ; 10(2)2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36829644

RESUMO

The attachment or entrapment of microbial cells and enzymes are promising solutions for various industrial applications. When the traps are beads, they are dispersed in a fluidized bed in a vessel where a pump guarantees fresh liquid inflow and waste outflow without washing out the cells. Scientific papers report numerous types of cell entrapment, but most of their applications remain at the laboratory level. In the present research, rigid polymer beads were manufactured by two different additive manufacturing (AM) techniques in order to verify the economy, reusability, and stability of the traps, with a view toward a straightforward industrial application. The proposed solutions allowed for overcoming some of the drawbacks of traditional manufacturing solutions, such as the limited mechanical stability of gel traps, and they guaranteed the possibility of producing parts of constant quality with purposely designed exchange surfaces, which are unfeasible when using conventional processes. AM proved to be a viable manufacturing solution for beads with complex shapes of two different size ranges. A deep insight into the production and characteristics of beads manufactured by AM is provided. The paper provides biotechnologists with a manufacturing perspective, and the results can be directly applied to transit from the laboratory to the industrial scale.

3.
Materials (Basel) ; 14(18)2021 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-34576399

RESUMO

In this paper, we explore and modify the structural, mechanical, and decorative properties of films composed by TiN and Ti (N, C) with a wide range of N2 gas flow during the deposition in order to be used on orthodontic systems. The films were grown using reactive DC magnetron sputtering from a pure Ti target and customized with C pellets onto Si and stainless steel 316L substrates. The structural properties were studied using X-ray diffraction and scanning electron microscopy, while the mechanical ones were obtained through hardness, elastic modulus, and friction coefficient. Moreover, the wear rate has been measured under an artificial saliva medium to simulate the oral cavity. The color of the films deposited onto stainless steel 316 L substrate was characterized through CIELab color code. Our findings show that the addition of N2 and C in the Ti matrix improves the mechanical properties of the films. With the increase in the amount of N2 and C, the hardness reaches a value of 739 HV, higher than the one reported in the literature (600 HV), a low value of the coefficient of elasticity (8.0 GPa), and also a low friction coefficient (0.30). Moreover, with the addition of N2 and C in the Ti films, the color of the films changes from metallic aspect until "with" gold, which means that our coatings exhibit versatile mechanical and color characteristics to be used in orthodontic wires applications.

4.
Materials (Basel) ; 12(9)2019 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-31083618

RESUMO

The development of novel Ti-based amorphous or ß-phase nanostructured metallic materials could have significant benefits for implant applications, due to potentially improved corrosion properties, and mechanical characteristics (lower Young's modulus, better wear performance, improved fracture toughness) in comparison to the standardized α+ß titanium alloys. Moreover, the devitrification phenomenon, occurring during heating, could contribute to lower input power during additive manufacturing technologies. Ti-based alloy ribbons were obtained by melt-spinning, considering the ultra-fast cooling rates this method can provide. The titanium alloys contain Zr, Nb, and Si (Ti60Zr10Si15Nb15, Ti64Zr10Si15Nb11, Ti56Zr10Si15Nb19) in various proportions. These elements were chosen due to their reported biological safety, as in the case of Zr and Nb, and the metallic glass-forming ability and biocompatibility of Si. The morphology and chemical composition were analyzed by scanning electron microscopy and energy-dispersive X-ray spectroscopy, while the structural features (crystallinity, phase attribution after devitrification (after heat treatment)) were assessed by X-ray diffraction. Some of the mechanical properties (hardness, Young's modulus) were assessed by instrumented indentation. The thermal stability and crystallization temperatures were measured by differential thermal analysis. High-intensity exothermal peaks were observed during heating of melt-spun ribbons. The corrosion behavior was assessed by electrocorrosion tests. The results show the potential of these alloys to be implemented as materials for biomedical applications.

5.
J Mech Behav Biomed Mater ; 40: 240-251, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25255419

RESUMO

In-stent restenosis (ISR) remains a significant limitation despite the considerable previous clinical and investigative emphasis on the problem. Complications arising from the interaction of stent materials with the surrounding vessel wall as well as from the mechanical forces developing after implantation, play an important role in the development of ISR. To investigate the relation between mechanical factors and stent structural integrity, and to identify any structural weakness points on the geometry of commercially available Stainless Steel and Cobalt-Chromium stents, accelerated pulsatile durability tests were carried out in a simulated physiological environment. Potential spatial variations in the mechanical properties on stent struts and their role in the observed premature failures of the stent devices during operation were also examined. Fretting wear and fatigue-induced fractures were found on stent surfaces after exposure to cyclic loading similar to that arising in vivo. Nanoindentation studies performed on various locations along the stent struts have shown that the hardness of specific stent locations significantly increases after mechanical expansion. The increase in hardness was associated with a reduction of the material's ability to dissipate energy in plastic deformations, therefore an increased vulnerability to fracture and fatigue. We conclude that the locations of fatigue fractures in stent struts are controlled not only by the geometrically-driven stress concentrations developing during cyclic loading but also by the local material mechanical changes that are imparted on various parts of the stent during the deployment process.


Assuntos
Cromo , Cobalto , Aço Inoxidável , Stents , Constrição Patológica , Teste de Materiais , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA