Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Contrast Media Mol Imaging ; 2022: 8676787, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36082064

RESUMO

Purpose: In head and neck squamous cell carcinoma (HNSCC), the early diagnosis and efficient detection of recurrences and/or residual tumor after treatment play a very important role in patient's prognosis. Positron emission tomography (PET) using 2-deoxy-2-18F-fluoro-D-glucose (18F-FDG) has become an established method for the diagnosis of suspected recurrence in head and neck carcinomas. In particular, integrated PET/MRI imaging that provides optimal soft tissue contrast and less dental implant artifacts compared to PET/CT is an intriguing technique for the follow-up imaging of HNSCC patients. The aim of this study was to evaluate the benefit of PET/MRI compared to PET/CT in post-treatment follow-up imaging of HNSCC patients. Methods: This retrospective observational cohort study consists of 104 patients from our center with histologically confirmed HNSCC. All patients received chemoradiotherapy (CRT) and underwent 18F-FDG-PET/CT (n = 52) or 18F-FDG-PET/MRI (n = 52) scan 12 weeks after the end of treatment. Image analysis was performed by two independent readers according to a five-point Likert scale analysis. Results: PET/MRI was more sensitive (1.00 vs. 0.77) than PET/CT in the detection of locoregional recurrence. PET/MRI also had better negative (1.00 vs. 0.87) predictive values. AUCs for PET/MRI and PET/CT on patient-based analysis were 0.997 (95% CI 0.989-1.000) and 0.890 (95% CI 0.806-0.974), respectively. The comparison of sensitivity, AUCs, and negative predictive values revealed a statistically significant difference, p < 0.05. In PET/CT, false-negative and positive findings were observed in the more advanced disease stages, where PET/MRI performed better. Also, false-negative findings were located in the oropharyngeal, laryngeal, and nasopharyngeal regions, where PET/MRI made no false-negative interpretations. Conclusion: Based on these results, PET/MRI might be considered the modality of choice in detecting locoregional recurrence in HNSCC patients, especially in the more advanced stages in the oral cavity, larynx, or nasopharynx.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia
2.
Duodecim ; 133(5): 497-500, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29206000

RESUMO

According to current best knowledge, an MRI scan can be performed for patients with cochlear implants. The warnings and recommendations of the implant manufacturers must be followed strictly to prevent complications, such as overheating, migration or demagnetization of the magnet in the implant. We report on a case of cochlear implant magnet dislocation as a complication for an MRI scan. The patient had a tight bandage around the head to hold the magnet in place as recommended by the manufacturer, but apparently the bandage was not in the correct place.


Assuntos
Implantes Cocleares , Migração de Corpo Estranho/etiologia , Imageamento por Ressonância Magnética , Falha de Equipamento , Humanos , Imãs
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA