Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Drug Test Anal ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517060

RESUMO

As gamma-hydroxybutyric acid (GHB) underlies fast metabolization, its determination from hair may presumably offer a detection window superior to that of body fluids. Due to the wide range of endogenous concentration levels, the evidence of an exogenous ingestion is challenging. As already shown for other drugs, the temporal resolution obtained by applying single hair microanalysis provides further information. Therefore, a method for the extraction and quantification of GHB in 2-mm hair segments (seg) was optimized and validated (limit of detection [LOD]: 2.5 pg/seg, lower limit of quantification [LLOQ]: 5 pg/seg), and five single hairs were examined, each for three non-users and for three (alleged) users. A major challenge was the choice of appropriate extraction tubes without remains of GHB. In two samples from non-users, GHB could not or could only be detected in trace amounts. In the third sample, concentrations between the LOD and 31.1 pg/seg (mean: 9.5, median: 8.4; each pg/seg) were detected with decreasing values towards the tips. In two samples of persons with assumed GHB intake, maximum concentrations of 6.8 and 30.7 pg/seg were measured, but no significant concentration peaks indicating a single ingestion could be observed. The third sample showed concentrations of 7.6-55.2 pg/seg (mean: 28.8, median: 29.6; each pg/seg). In this case, the obtained profiles showing at least two reproducible concentration maxima between 20 and 40 mm point to an ingestion of GHB. The concentration profiles from single hairs were reproducible in each case, reflecting the concentration course of routine 1-cm segmental analysis. These are the first results published on GHB testing in segmented single hairs, and the results must be verified further.

2.
Drug Test Anal ; 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350637

RESUMO

Synthetic cannabinoid receptor agonists (SCRAs) are one of the largest groups of new psychoactive substances (NPS). Yet, another novel analog started spreading on the NPS market around 2021. Soon after, the substance could be analytically characterized in herbal material as ADB-HEXINACA, an SCRA containing a hexyl-substituted tail on the indazole core. Here, we present suitable urinary markers to prove the consumption of this analog, a case report of acute polydrug intoxication and data on its prevalence in Germany. Anticipated phase I metabolites were detected in 12 authentic urine samples that were collected for abstinence control and analyzed by ultra-performance liquid chromatography coupled to a time-of-flight mass spectrometer (UPLC-qToF-MS). The results of in vivo samples were confirmed by analysis of in vitro incubates with pooled human liver microsomes (pHLMs). Forensic samples were used to assess the prevalence of ADB-HEXINACA. Thirty-two phase I metabolites were detected in the authentic urine samples. The main metabolites resulted from amide hydrolysis in combination with either monohydroxylation or ketone formation at the hexyl moiety (M15 and M26), the monitoring of which is recommended as a proof of consumption. ADB-HEXINACA was detected in 3.5% of SCRA positive urine samples collected for abstinence control in Freiburg up to December 2022 and in 5.5% of the SCRA positive blood/serum samples. The hexyl substituent of ADB-HEXINACA allows for the detection of specific urinary biomarkers suggested as analytical targets to confirm its prior intake. ADB-HEXINACA had a rather low prevalence in Germany, alternating months of higher prevalence with periods of total absence.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA