Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
5.
J Arrhythm ; 37(2): 338-347, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33850575

RESUMO

BACKGROUND: Substrate analysis of the left atrium in patients undergoing atrial fibrillation ablation has limitations when performed by means of simple bipolar acquisition. OBJECTIVE: To evaluate the incidence of low-voltage zones (LVZs) through maps constructed by means of various catheters: multipolar (MC), omnipolar (OC), and circular catheters (CMCs) with the 3D electro-anatomical systems (3d-S) CARTO3 and EnSite Precision. METHODS: To assess LVZs, we acquired maps by means of CMC and MC in the voltage range 0.05-0.5 mV in 70 consecutive patients in sinus rhythm. In the case of OC only, we made an intra-patient comparison of bipolar maps constructed by means of the along and across, and HD-Wave configurations of the EnSite 3d-S in the ranges of 0.05-0.5 and 0.5-1.0 mV. On the basis of this comparison, we chose the range that best identified LVZs as a set of different colors (SDC) compatible with patchy fibrosis (qualitative analysis). Subsequently, we detected the voltage values corresponding to purple and gray points, close to SDC, and the value inside corresponding to blue, green, and red colors, and we evaluated the color change in other voltage ranges. Finally, we performed a quantitative analysis of LVZs by applying the qualitative characteristics described above. RESULTS: On the basis of our settings, for OC, the optimal range identifying LVZs was 0.3-0.6 mV. OC revealed smaller LVZs than MC (P < .05 or P < .001), except in the lateral wall. No significant differences were observed between CMCs. CONCLUSIONS: In our experience, OC does not present the limits of bipolar HD maps, though further studies are needed in order to confirm that 0.3-0.6 mV is the optimal voltage range within which to identify LVZs.

6.
Case Rep Cardiol ; 2021: 8834133, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33628520

RESUMO

BACKGROUND: Atrial Fibrillation ablation in older patients represents a challenge to be addressed to ensure the improvement of the quality of life and survival of these patients. New mapping system tools can help to treat older patients because of its ability to simplify and reduce procedural risks. The new NavX EnSite "Live view" tool allows dynamic "beat to beat" activation and voltage mapping visualization in order to instantly recognize vein disconnection and minimize RF deliveries. METHODS: An 81-year old patient with paroxysmal AF and well-documented firing focus trigger underwent pulmonary veins isolation using NavX EnSite Precision, HD Grid multipolar catheter, and the new "Live view" tool. RESULTS: All pulmonary veins were successfully isolated with no procedural complications. "Live view" tool allows to perform shorter and safer procedure (total procedural time: 90 minutes, left atrium dwell time: 60 minutes, total RF delivery number: 78). CONCLUSION: "Live view tool" allows dynamic activation and voltage mapping in order to perform a safe and tailored approach to ablation, especially in older patients.

8.
J Cardiovasc Med (Hagerstown) ; 20(7): 464-470, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30994511

RESUMO

AIMS: We aimed to corroborate clinical evidence on the safety and efficacy of the ultrathin-strut biodegradable-polymer sirolimus-eluting Orsiro stent in an all-comer population including high-risk subgroups. METHODS: The nationwide, prospective, all-comer BIOFLOW-III Satellite Registry was conducted at 18 Italian sites. High-risk subgroups [diabetes, small vessels (≤2.75 mm), acute myocardial infarction (AMI), and chronic total occlusions (CTOs)] were prespecified. The primary endpoint was target lesion failure (TLF) at 12 months, a composite of cardiac death, target vessel myocardial infarction (MI), emergent coronary artery bypass graft, and clinically driven target lesion revascularization (TLR). RESULTS: In all, 601 patients were enrolled (31.9% diabetes, 34.6% AMIs) with 736 lesions (37.2% small vessels, 5.7% CTOs, and 15.5% bifurcation lesions). Cumulative TLF rate at 12 months was 4.6% [95% confidence interval (CI) 3.2-6.6]: 6.9% (95% CI 4.1-11.6) in the diabetic patients, 5.0% (95% CI 2.7-9.1) in acute MI subgroup, 4.2% (95% CI 2.3-7.7) in small vessels, and 5.3% (95% CI 1.4-19.7) in CTOs. At 18-month follow-up, TLF, target vessel revascularization, and clinically driven TLR rates in the overall population were 5.2% (95% CI 3.7-7.4), 1.8% (95% CI 1.0-3.3), and 1.6% (95% CI 0.8-3.1), respectively. Probable stent thrombosis rate was 0.5% (95% CI 0.1-1.4), whereas no definite stent thrombosis was observed. CONCLUSIONS: The study results confirmed the excellent clinical performance of the Orsiro drug-eluting stents at 18 months in the whole all-comer population and in the prespecified high-risk subgroups.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Stents Farmacológicos , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Sirolimo/administração & dosagem , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Fármacos Cardiovasculares/efeitos adversos , Trombose Coronária/epidemiologia , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
9.
Int J Cardiol ; 221: 1008-12, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27441483

RESUMO

BACKGROUND: Diffuse coronary artery disease treatment still remains a challenge for interventional cardiologists and cardiac surgeons. There are few data on full metal jacket (FMJ) stenting, especially with new-generation drug-eluting stents. We aimed to assess the efficacy and safety of FMJ with new-generation Zotarolimus-eluting stents (n-ZES). METHODS AND RESULTS: All patients who underwent FMJ with n-ZES (≥60mm stent length) in eleven Italian interventional centers participating in the Clinical Service® project were included in this analysis. The project population consisted of 120 patients and 122 lesions. Mean age was 67±10years and 95 (79.2%) patients were male. A chronic total occlusion was present in 34 lesions (27.9%). The number of stents implanted per lesion was 2.9±0.8, and the diameter of the stents was 3.0±0.5mm. Predilation and post-dilatation were performed in 107 (87.7%) and 92 (75.4%) patients, respectively. At 41±21month follow-up there were 2 patients with subacute definite stent thrombosis, 6 patients (5.0%) had cardiac death and 5 patients (4.2%) had non-fatal myocardial infarction. Seven patients (5.8%) underwent clinically-driven target lesion revascularization. Fourteen patients (11.7%) had at least one major adverse cardiac event. CONCLUSION: The treatment of diffuse coronary artery disease with FMJ stenting with n-ZES appears to be effective and safe. Late and very-late ST does not seem to be an issue and the rate of restenosis and of major cardiac adverse events after more than 3-year follow-up is rather low.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos/efeitos adversos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Feminino , Humanos , Itália/epidemiologia , Efeitos Adversos de Longa Duração/epidemiologia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/epidemiologia , Índice de Gravidade de Doença , Resultado do Tratamento
10.
Int J Cardiol ; 220: 761-7, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27393863

RESUMO

AIMS: To define a benchmark target for an invasive strategy (IS) rate appropriate for performance assessment in intermediate-to-high risk non-ST-segment elevation acute coronary syndromes (NSTE-ACS). METHODS AND RESULTS: During the BLITZ-4 campaign, which aimed at improving the quality of care in 163 Italian coronary care units, 4923/5786 (85.1%) of consecutive patients admitted with NSTE-ACS with troponin elevation and/or dynamic ST-T changes on the electrocardiogram were managed with IS. The reasons driving the choice (RDC) for a conservative strategy (CS) in the remaining 863 patients were prospectively recorded. In 33.8%, CS was mandatory because of patients refusal, known coronary anatomy or death before coronary angiography; in 52.8% it was clinically justified because of active stroke, bleeding, advanced frailty, severe comorbidities, contraindication to antiplatelet therapy or because they were considered to be at low risk; only in 13.4% the reasons, such as renal failure, advanced age or other, were less stringent. As compared to patients undergoing IS, those in the CS were 12years older and had significantly more severe comorbidities. The in-hospital and 6-month all-cause mortality were 9.0% vs 0.9% and 22.0% vs 3.9% in CS and IS groups respectively (p<0.0001 for both). CONCLUSION: As the RDC for CS were clinically correct in vast majority of cases the observed 85% invasive strategy rate may be considered as the desirable benchmark target in patients with NSTE-ACS. For the same reason, it remains questionable if the higher rate of IS could have improved the prognosis in CS patients, despite their highly unfavorable prognosis.


Assuntos
Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/terapia , Benchmarking/normas , Admissão do Paciente/normas , Qualidade da Assistência à Saúde/normas , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Benchmarking/métodos , Angiografia Coronária/normas , Eletrocardiografia/normas , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Admissão do Paciente/tendências , Resultado do Tratamento
11.
G Ital Cardiol (Rome) ; 17(6 Suppl 2): 13S-20, 2016 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-27384601

RESUMO

BACKGROUND: Significant developments have occurred in the field of percutaneous interventions for structural heart disease over the last decade. The introduction of several innovations has expanded significantly the spectrum of therapeutic applications of structural interventional cardiology. However, the translation of the most recent scientific evidence into clinical practice and the adoption of new technologies may be susceptible to large variability, even within the same geographic area. This study aimed at describing current status and changing trends of structural heart interventions within 6 Regions in Italy. METHODS: Between July 2015 and October 2015, 6 regional delegations of the Italian Society of Interventional Cardiology (SICI-GISE) promoted a web-based multicenter survey concerning structural heart interventions. An ad hoc questionnaire was administered to head physicians of the cath-labs of 4 Regions of Northern Italy (Tuscany, Lombardy, Veneto and Emilia-Romagna) and 2 Regions of Southern Italy (Puglia and Campania). Also, in this study we considered previous data from a similar survey that involved Tuscany, Lombardy, Veneto and Emilia-Romagna between April 2014 and May 2014. Data from the two surveys were compared, observing the changing trends between 2014 and 2015. RESULTS: The 2015 survey was completed in more than two thirds (68%) of the 145 eligible cath-labs. According to the survey, the application of percutaneous structural heart interventions and the availability of devices were wide and homogeneous within the 6 Regions involved. The main factors perceived as limiting the execution of structural heart interventions resulted economic (e.g. cost of procedures and devices) or organizational (e.g. limited diffusion of hybrid operating rooms). CONCLUSIONS: In this study, which was based on the results of a recent survey conducted in 6 Italian Regions, structural heart interventions resulted widely growing throughout the investigated area. The indications for treatment and the availability of devices were relatively homogeneous between the regions involved, as well as the limiting factors, which appear to be mainly economic-organizational.


Assuntos
Cardiopatias/terapia , Intervenção Coronária Percutânea , Humanos , Itália , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA