Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Esthet Restor Dent ; 36(7): 1075-1080, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38716797

RESUMO

STATEMENT OF PROBLEM: Limited evidence is available for the effect of chairside adjustment using rotary cutting instruments on the surface roughness and optical properties of different zirconia types. PURPOSE: To evaluate the effect of simulated adjustments on surface roughness and optical properties of different zirconia types. MATERIALS AND METHODS: Three Partially Stabilized Zirconia (PSZ) types based on mole percent yttria (Y) concentration from the same manufacturer (Katana; Kuraray) were used: 3Y-PSZ, 4Y-PSZ, and 5Y-PSZ. Thirty disk-shaped specimens (Ø14 × 1.2 mm) from different zirconia types (N = 90) were prepared. Specimens were either left without adjustment (NA), adjusted with Dialite ZR finishing and polishing system (Brasseler) (APol), or adjusted with course diamond instruments only (ADia). The specimens were distributed into 9 groups (n = 10): Group 3Y-PSZ/NA, Group 3Y-PSZ/APol, Group 3Y-PSZ/ADia, Group 4Y-PSZ/NA, Group 4Y-PSZ/APol, Group 4Y-PSZ/ADia, Group 5Y-PSZ/NA, Group 5Y-PSZ/APol, and Group 5Y-PSZ/ADia. The surface roughness of specimen was analyzed using an Atomic Force Microscope (AFM) (Bruker's Dimension Icon, Bruker) and Root Means Square (RMS) were recorded (nm). Surface Gloss (SG), Translucency Parameter (TP), and Contrast Ratio (CR) values of all groups were recorded using an integrating sphere spectrophotometer. Statistical analysis was performed using analysis of variance (ANOVA) and Tukey's multiple comparison tests for pairwise comparisons at p < 0.05 and 95% confidence interval. RESULTS: APol had no effect on the surface roughness (p = 0.88) while ADia had a significant negative effect (p < 0.05) despite the type of zirconia. Out of the three testes optical properties, only SG was negatively affected by ADia for all types of zirconia (p < 0.05). The two adjustment types did not affect the TP of all the tested zirconia (p = 0.91). The CR was not affected by the tested adjustments for all zirconia types (p = 0.726). CONCLUSION: Proper zirconia adjustment following a sequence of burs and polishers can maintain acceptable roughness and optical properties. Adjustment of zirconia with rough diamond can lead to deleterious effects and should be avoided. CLINICAL SIGNIFICANCE: Chairside adjustment of zirconia could lead to rougher surface and unpredictable changes of surface gloss. Therefore, zirconia adjustment should be minimized to the greatest extent possible and a proper protocol should be followed if had to be done.


Assuntos
Propriedades de Superfície , Zircônio , Zircônio/química , Teste de Materiais
2.
Clin Oral Investig ; 27(11): 6865-6877, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37821653

RESUMO

OBJECTIVES: To investigate the impact of simulated gastric acid on the surface properties of lithium disilicate-reinforced glass-ceramics and zirconia-reinforced lithium silicate glass-ceramic after certain polishing and glazing procedures. MATERIALS AND METHODS: Four different types of square-shaped specimens (10 × 10 × 2 mm3, n = 13) were manufactured: lithium disilicate-reinforced glass-ceramic milled and polished (LDS-P); milled, polished, and glazed (LDS-PG); milled, glazed, and no polishing (LDS-G); and milled and polished zirconia-reinforced lithium silicate glass-ceramic (ZR-LS). Specimens were immersed in hydrochloride acid (HCl 0.06 M, pH 1.2) to simulate gastric acid irritation and stored in the acid for 96 h in 37 °C. Specimen weight, surface gloss, Vickers surface microhardness and surface roughness (Ra, Rq, with optical profilometer), and surface roughness on nanometer level (Sq, Sal, Sq/Sal, Sdr, Sds with atomic force microscope) were measured before and after the acid immersion. RESULTS: ZR-LS specimens lost significantly more weight after acid immersion (p = 0.001), also surface microhardness of ZR-LS was significantly reduced (p = 0.001). LDS-G and LDS-PG showed significantly lower surface roughness (Sa, Sq) values compared to LDS-P before (p ≤ 0.99) and after (p ≤ 0.99) acid immersion and ZR-LS after acid immersion (p ≤ 0.99). CONCLUSIONS: Gastric acid challenge affects the surface properties of lithium disilicate-reinforced glass-ceramic and zirconia-reinforced lithium silicate glass-ceramic. Glazing layer provides lower surface roughness, and the glazed surface tends to smoothen after the gastric acid challenge. CLINICAL RELEVANCE: Surface finish of lithium disilicate-reinforced glass-ceramic and zirconia-reinforced lithium silicate glass-ceramic has a clear impact on material's surface properties. Gastric acidic challenge changes surface properties but glazing seems to function as a protective barrier. Nevertheless, also glazing tends to smoothen after heavy gastric acid challenge. Glazing can be highly recommended to all glass-ceramic restorations but especially in patients with gastroesophageal reflux disease (GERD) and eating disorders like bulimia nervosa.


Assuntos
Ácido Gástrico , Lítio , Humanos , Teste de Materiais , Desenho Assistido por Computador , Porcelana Dentária/química , Cerâmica/química , Zircônio/química , Silicatos , Propriedades de Superfície
3.
Tissue Eng Part C Methods ; 29(5): 183-196, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37002888

RESUMO

Bioactive glasses (BAGs) are surface-active ceramic materials that can be used in bone regeneration due to their known osteoconductive and osteoinductive properties. This systematic review aimed to study the clinical and radiographic outcomes of using BAGs in periodontal regeneration. The selected studies were collected from PubMed and Web of Science databases, and included clinical studies investigating the use of BAGs on periodontal bone defect augmentation between January 2000 and February 2022. The identified studies were screened using Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. A total of 115 full-length peer-reviewed articles were identified. After excluding duplicate articles between the databases and applying the inclusion and exclusion criteria, 14 studies were selected. The Cochrane risk of bias tool for randomized trials was used to assess the selected studies. Five studies compared using BAGs with open flap debridement (OFD) without grafting materials. Two of the selected studies were performed to compare the use of BAGs with protein-rich fibrin, one of which also included an additional OFD group. Also, one study evaluated BAG with biphasic calcium phosphate and used a third OFD group. The remaining six studies compared BAG filler with hydroxyapatite, demineralized freeze-dried bone allograft, autogenous cortical bone graft, calcium sulfate ß-hemihydrate, enamel matrix derivatives, and guided tissue regeneration. This systematic review showed that using BAG to treat periodontal bone defects has beneficial effects on periodontal tissue regeneration. OSF Registration No.: 10.17605/OSF.IO/Y8UCR.


Assuntos
Perda do Osso Alveolar , Regeneração Tecidual Guiada Periodontal , Humanos , Perda do Osso Alveolar/cirurgia , Periodonto , Transplante Ósseo , Regeneração Óssea
4.
Clin Implant Dent Relat Res ; 25(2): 409-418, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36602418

RESUMO

OBJECTIVES: The present study aimed to evaluate the healing of experimentally induced bone defects around contaminated dental implants after air-abrasion using 45S5 or zinc oxide (ZnO)-containing bioactive glasses (BAGs). MATERIALS AND METHODS: One maxillary first molar was extracted from each Sprague-Dawley rat (n = 30). After 4-week healing, a titanium implant was placed in the extraction site with a circumferential bone defect. The rats were randomized into five different groups: (1) implants with Fusobacterium nucleatum and Porphyromonas gingivalis dual-species biofilm (IB); (2) implants with biofilm subjected to inert glass air-abrasion (inert); (3) sterile implants (S); (4) implants with biofilm subjected to 45S5 BAG air-abrasion (45S5); and (5) implants with biofilm subjected to ZnO-containing BAG air-abrasion (Zn4). After 8-week healing, maxillae were dissected, and histomorphometric analyses were performed. RESULTS: The first bone-to-implant contact was significantly shorter for the inert (1.58 ± 1.16 mm; p = 0.016), S (0.28 ± 0.13 mm; p < 0.001), 45S5 (0.41 ± 0.28 mm; p < 0.001), and Zn4 (0.26 ± 0.16 mm; p < 0.001) groups compared to IB group. Also, significantly more bone-to-implant contact was seen for S (72.35% ± 8.32%; p < 0.001), 45S5 (57.91% ± 24.10%; p = 0.002), and Zn4 (70.49% ± 12.74%; p < 0.001) groups than the IB group. The bone volume with the threads demonstrated significantly higher value for S (69.32% ± 9.15%; p < 0.001), 45S5 (58.93% ± 23.53%; p = 0.001), and Zn4 (68.65% ± 12.41%; p < 0.001) groups compared to the IB group. The bone volume within the defects was significantly higher for S (68.79% ± 11.77%; p < 0.001), 45S5 (62.51% ± 20.51%; p = 0.002), and Zn4 (73.81% ± 15.07%; p < 0.001) groups compared to the IB group. CONCLUSIONS: This study suggests that air-abrasion of contaminated moderately rough implant surfaces with either 45S5 or ZnO-containing BAGs enhances osseointegration and bone defect regeneration.


Assuntos
Implantes Dentários , Óxido de Zinco , Ratos , Animais , Propriedades de Superfície , Ratos Sprague-Dawley , Osseointegração , Titânio
5.
J Prosthet Dent ; 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35934577

RESUMO

STATEMENT OF PROBLEM: Limited evidence is available for the effect of chairside adjustment using diamond instruments on different types of zirconia. PURPOSE: The purpose of this in vitro study was to evaluate the effect of simulated adjustments on the biaxial flexural strength and phase transformation of 3 different zirconia types. MATERIAL AND METHODS: Three zirconia types from the same manufacturer (Katana; Kuraray) were used: High Translucency (3Y-PSZ), Super Translucent Multi Layered (4Y-PSZ), and Ultra Translucent Multi Layered (5Y-PSZ). Thirty disk-shaped specimens (Ø14×1.2 mm) were fabricated according to the International Organization for Standardization (ISO) Standard 6872 from different zirconia types (N=90). Specimens were either left without adjustment (NA), adjusted with Dialite ZR finishing and polishing system (Brasseler) (APol), or adjusted with course diamond instruments only (ADia). The specimens were distributed into 9 groups (n=10): group 3Y-PSZ/NA, group 3Y-PSZ/APol, group 3Y-PSZ/ADia, group 4Y-PSZ/NA, group 4Y-PSZ/APol, group 4Y-PSZ/ADia, group 5Y-PSZ/NA, group 5Y-PSZ/APol, and group 5Y-PSZ/ADia. The biaxial flexural strength of each specimen was measured by using a universal testing machine (Model 4411; Instron) and according to ISO 6872. X-ray diffraction analysis was conducted to quantify the monoclinic phase transformation. Scanning electron microscopy images were obtained to evaluate the fracture pattern. Statistical analysis was performed by using analysis of variance (ANOVA) and Tukey multiple comparison tests for pairwise comparisons (α=.05). RESULTS: The mean biaxial flexural strengths ranked from the highest to the lowest were for 3Y-PSZ, 4Y-PSZ, and 5Y-PSZ under any test condition (P=.007). Chairside adjustment with a diamond instrument significantly decreased the flexural strength of all zirconia types (P<.05). No statistically significant difference was found between the effect of APol and ADia on the strength of zirconia 3Y-PSZ (P=.603), 4Y-PSZ (P=.993), and 5Y-PSZ (P=.660). Phase transformation did not occur in the 5Y-PSZ groups. ADia groups had significantly higher phase transformation values regardless of zirconia type (P<.05). CONCLUSIONS: The biaxial flexural strength of zirconia decreased significantly after chairside adjustment with diamond instruments regardless of the yttria percentage. Adjustment with the Dialite ZR finishing and polishing system caused less tetragonal to monoclinic phase transformation than adjustment with a course-grit diamond instrument.

6.
Int J Prosthodont ; 35(2): 194-200, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35507532

RESUMO

PURPOSE: To test the push-out force and marginal leakage of different screw hole-sealing methods in monolithic zirconia implant crowns. MATERIALS AND METHODS: Ninety monolithic zirconia (Prettau, Zirkonzahn) specimens were milled with two different screw access hole designs: conventional smooth hole or threaded screw hole (for group PMMA-SC), and divided into five groups (n = 18) according to filling method: unbonded composite (UBC); bonded composite (BC); airborne-particle abrasion of screw hole and unbonded composite (ABR-UBC); airborne-particle abrasion of screw hole and bonded composite (ABR-BC); and PMMA screw plugs (PMMA-SC). Twelve specimens per group were subjected to static push-out force with a universal testing machine. Before testing, 6 specimens per group were stored in dry conditions, and 6 were kept in water storage (+37°C) for 7 days. For the remaining specimens (n = 6), cotton pellets were placed under the screw access hole fillings, and the specimens were immersed in 0.5% basic fuchsin solution for 2 weeks. Dye in cotton pellets was dissolved in 2 mL of water, and absorbances of the solutions were measured with a spectrophotometer at 465 nm. Data are reported as mean and SD. Statistical analysis was made using a generalized linear model with logarithmic transformation. RESULTS: PMMA-SC specimens showed the highest push-out forces (P < .0001) and lowest fuchsin penetration (P = .009). Airborne-particle abrasion increased the push-out force and decreased the microleakage in composite groups. The storage conditions affected the results of both unbonded groups. CONCLUSION: The design and sealing method of the screw access hole affect push-out force and microleakage.


Assuntos
Implantes Dentários , Polimetil Metacrilato , Parafusos Ósseos , Coroas , Materiais Dentários , Análise do Estresse Dentário , Teste de Materiais , Água , Zircônio
7.
J Mater Sci Mater Med ; 32(11): 136, 2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34709465

RESUMO

In vitro studies of implant-tissue attachment are primarily based on two-dimensional cell culture models, which fail to replicate the three-dimensional native human oral mucosal tissue completely. Thus, the present study aimed to describe a novel tissue culture model using pig mandibular block including alveolar bone and gingival soft tissues to evaluate the tissue attachment to titanium implant provided with hydrothermally induced TiO2 coating. Tissue attachment on TiO2 coated and non-coated implants were compared. Ti-6Al-4V alloy posts were used to function as implants that were inserted in five pig mandibles. Implants were delivered with two different surface treatments, non-coated (NC) titanium and hydrothermal induced TiO2 coated surfaces (HT). The tissue-implant specimens were cultured at an air/liquid interface for 7 and 14 days. The tissue-implant interface was analyzed by histological and immunohistochemical stainings. The microscopic evaluation suggests that pig tissue explants established soft and hard tissue attachment to both implant surfaces. The epithelial cells appeared to attach to the coated implant. The epithelium adjacent to the implant abutment starts to change its phenotype during the early days of the healing process. New bone formation was seen within small pieces of bone in close contact with the coated implant. In conclusion, this in vitro model maintains the viability of pig tissue and allows histologically and immunohistochemically evaluate the tissue-implant interface. HT-induced TiO2 coating seems to have a favorable tissue response. Moreover, this organotypic tissue culture model is applicable for further studies with quantitative parameters to evaluate adhesion molecules present at the implant-tissue interface.


Assuntos
Ligas , Materiais Biocompatíveis , Implantes Dentários , Teste de Materiais , Técnicas de Cultura de Tecidos , Titânio , Animais , Mandíbula , Propriedades de Superfície , Suínos
8.
J Mech Behav Biomed Mater ; 122: 104653, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34229172

RESUMO

PURPOSE: The purpose of this finite element analysis (FEA) was to evaluate the effect of specific retention biomaterials with different elastic modulus on the biomechanical response to the axial and off-axial biting loads of a mandibular midline single implant-supported overdenture (SIO) model. METHODS: Five 3-dimensional (3D) finite element models of an edentulous mandible with SIO were designed as follows: model M with a titanium retentive element for ball attachment, model P with a PEEK retentive element, model S with a silicone resilient liner retentive element, model T with a thermoplastic acrylic resin retentive element made from a CAD-CAM material, and model A with a polyacetal resin retentive element. Posterior bilateral vertical load (PV) at the 1st molar areas and anterior oblique load (AO) at the incisal edge of the mandibular central incisors at a 30-degree angle of 100 N were applied. Stress values were recorded. RESULTS: Stress values were higher for all models under (AO) loading than under (PV) loading. Model M recorded the highest stress values on the implant, its components, cortical, and cancellous bone under both loading conditions. Under (AO) loading condition, the ball abutment von Mises stress value in model S was almost 7 times lower than that of model M (19 and 130 MPa respectively) and the other 3 models (P, T, and A) (119, 121, and 120 MPa respectively). However, model S recorded the highest value of denture base stress at the attachment area. CONCLUSIONS: The elastic modulus of retention materials can affect stresses generated on the implant overdenture components and supporting structures.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Materiais Biocompatíveis , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Mandíbula , Estresse Mecânico
9.
Eur J Oral Sci ; 129(3): e12783, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33724569

RESUMO

This aim of this study was to investigate the effects of three types of air-abrasion particles on dual-species biofilms of Fusobacterium nucleatum and Porphyromonas gingivalis, both of which were cultured on sandblasted and acid-etched (SA) titanium discs. Out of 24 SA discs with biofilm, 18 were exposed to either air-abrasion using Bioglass 45S5 (45S5 BG; n = 6), novel zinc (Zn)-containing bioactive glass (Zn4 BG; n = 6), or inert glass (n = 6). The efficiency of biofilm removal was evaluated using scanning electron microscopy (SEM) imaging and culturing techniques. Air-abrasion using 45S5 BG or Zn4 BG demonstrated a significant decrease in the total number of viable bacteria compared to discs air-abraded with inert glass or intact biofilm without abrasion. Moreover, P. gingivalis could not be detected from SEM images nor culture plates after air-abrasion with 45S5 BG or Zn4 BG. The present study showed that air-abrasion with 45S5 or Zn4 bioactive glasses can successfully eradicate dual-biofilm of F. nucleatum and P. gingivalis from sandblasted and acid-etched titanium discs.


Assuntos
Fusobacterium nucleatum , Porphyromonas gingivalis , Biofilmes , Microscopia Eletrônica de Varredura , Titânio
10.
Int J Prosthodont ; 34(6): 801­810, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33616556

RESUMO

PURPOSE: To compare the flexural strength and modulus of ball-soft liner­retained overdentures vs ballsocket­ retained overdentures, as well as to evaluate the effect of using glass fiber reinforcement on the mechanical properties of ball-soft liner­retained overdentures. MATERIALS AND METHODS: A total of 80 overdenture specimens were fabricated and divided equally into four groups (n = 20/group): specimens with a metal matrix (group 1); a silicone soft liner matrix (group 2); reinforced with one bundle of unidirectional Stick glass fiber placed above the silicone soft liner matrix (group 3); and reinforced with four weaves of bidirectional Stick Net glass fibers placed above the silicone soft liner matrix (group 4). Half of the specimens from each group were stored in water at room temperature (23°C ± 1°C) for 24 hours, while the other half were stored in water at 37°C for 30 days before being subjected to a static three-point loading test. RESULTS: After 1 day of water storage, the flexural strength and flexural modulus values of groups 1, 3, and 4 were not significantly different from each other (P = .788, P = .084), but were significantly higher than group 2 (P < .05). Water storage for 30 days significantly decreased the flexural strength of group 1 only (P < .001) and not the other three groups (P >.05). CONCLUSION: Overdentures retained with a metal matrix were not significantly different from those retained with a silicone soft liner matrix in terms of flexural strength and modulus after 30 days of water storage. Placing unidirectional and bidirectional glass-fiber reinforcement above soft liner matrices can increase the flexural strength of ball-soft liner­retained overdentures.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Resinas Compostas , Análise do Estresse Dentário , Resistência à Flexão , Vidro , Teste de Materiais , Maleabilidade , Estresse Mecânico , Propriedades de Superfície
11.
J Prosthet Dent ; 126(3): 407-412, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32958304

RESUMO

STATEMENT OF PROBLEM: The fracture incidence of implant-supported overdentures is more frequent in the area of attachment because of stress concentration and denture deformation in this area. How E-glass fiber reinforcement can address this problem is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the influence of unidirectional E-glass fiber reinforcement on the mid-line denture base strains of single implant-supported overdentures. MATERIAL AND METHODS: An experimental acrylic resin cast was constructed with a single implant placed in the mid-line area and a ball attachment screwed to the implant. Twenty-four experimental overdentures were constructed and divided into 4 groups: group AP fabricated from autopolymerizing acrylic resin without fiber reinforcement, group APF fabricated from autopolymerizing acrylic resin with unidirectional E-glass fiber reinforcement running over the residual ridge and the ball matrix, group HP fabricated from heat-polymerized acrylic resin without fiber reinforcement, and group HPF fabricated from heat-polymerized acrylic resin with unidirectional E-glass fiber reinforcement running over the residual ridge and the ball matrix. A biaxial rosette strain gauge was attached to the incisor areas of each overdenture above the attachment level (Ch1, Ch2) and to a multichannel digital strain meter. A static vertical load of 100 N was applied to the first molar area bilaterally by using a universal testing device during strain measurement procedures. The differences in the mean strain and deflection values among the investigated groups were evaluated for statistical significance using 1-way analysis of variance (ANOVA) with the Tukey post hoc multiple comparison (α=.05). RESULTS: The type of acrylic resin did not have a statistically significant effect on the mean strain values among groups (P=.350), while the reinforcement did significantly affect them (P<.001). The interaction between reinforcement and acrylic resin was not statistically significant (P=.552). Both strain gauge channels in group APF and group HPF recorded significantly lower strain values by almost 50% than those of group AP and group HP (P<.05). CONCLUSIONS: Unidirectional E-glass fiber reinforcement placed over the residual ridge and implant attachment significantly reduced denture base strains and deformation of single implant-supported overdentures.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Bases de Dentadura , Vidro , Teste de Materiais , Estresse Mecânico
13.
Eur J Oral Sci ; 128(2): 160-169, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32154611

RESUMO

The aim of this study was to evaluate the hydrophilicity, surface free energy, and proliferation and viability of human osteoblast-like MC3T3-E1 cells on sandblasted and acid-etched titanium surfaces after air-abrasion with 45S5 bioactive glass, zinc-containing bioactive glass, or inert glass. Sandblasted and acid-etched titanium discs were subjected to air-abrasion with 45S5 bioactive glass, experimental bioactive glass (Zn4), or inert glass. Water contact angles and surface free energy were evaluated. The surfaces were studied with preosteoblastic MC3T3-E1 cells. Air-abrasion with either type of glass significantly enhanced the hydrophilicity and surface free energy of the sandblasted and acid-etched titanium discs. The MC3T3-E1 cell number was higher for substrates air-abraded with Zn4 bioactive glass and similar to that observed on borosilicate coverslips (controls). Confocal laser scanning microscopy images showed that MC3T3-E1 cells did not spread as extensively on the sandblasted and acid-etched and bioactive glass-abraded surfaces as they did on control surfaces. However, for 45S5- and Zn4-treated samples, the cells spread most at the 24 h time point and changed their morphology to more spindle-like when cultured further. Air-abrasion with bioactive glass and inert glass was shown to have a significant effect on the wettability and surface free energy of the surfaces under investigation. Osteoblast cell proliferation on sandblasted and acid-etched titanium discs was enhanced by air-abrasion with 45S5 bioactive glass and experimental Zn4 bioactive glass compared with air-abrasion with inert glass or no air-abrasion.


Assuntos
Osteoblastos , Proliferação de Células , Humanos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Titânio , Molhabilidade
14.
J Oral Implantol ; 45(6): 444-450, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31536440

RESUMO

Streptococcus mutans is able to form a high-affinity biofilm on material surfaces. S mutans has also been detected around infected implants. Bioactive glasses (BAGs) have been shown to possess antibacterial effects against S mutans and other microorganisms. This in vitro study was performed to investigate the influence of BAG air abrasion on S mutans biofilm on sandblasted and acid-etched titanium surfaces. Sandblasted and acid-etched commercially pure titanium discs were used as substrates for bacteria (n = 107). The discs were immersed in an S mutans solution and incubated for 21 hours to form an S mutans biofilm. Twenty colonized discs were subjected to air abrasion with Bioglass 45S5 (45S5 BAG), experimental zinc oxide containing BAG (Zn4 BAG), and inert glass. After the abrasion, the discs were incubated for 5 hours in an anaerobic chamber followed by an assessment of viable S mutans cells. Surface morphology was evaluation using scanning electron microscopy (n = 12). The thrombogenicity of the glass particle-abraded discs (n = 75) was evaluated spectrophotometrically using whole-blood clotting measurement at predetermined time points. Air abrasion with 45S5 and Zn4 BAG eradicated S mutans biofilm. Significantly fewer viable S mutans cells were found on discs abraded with the 45S5 or Zn4 BAGs compared with the inert glass (P < .001). No significant differences were found in thrombogenicity since blood clotting was achieved for all substrates at 40 minutes. Air abrasion with BAG particles is effective in the eradication of S mutans biofilm from sandblasted and acid-etched titanium surfaces. Zn4 and 45S5 BAGs had similar biofilm-eradicating effects, but Zn4 BAG could be more tissue friendly. In addition, the steady release of zinc ions from Zn4 may enhance bone regeneration around the titanium implant and may thus have the potential to be used in the treatment of peri-implantitis. The use of either BAGs did not enhance the speed of blood coagulation.


Assuntos
Peri-Implantite , Streptococcus mutans , Biofilmes , Humanos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Titânio
15.
J Prosthet Dent ; 122(6): 557-563, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30982623

RESUMO

STATEMENT OF PROBLEM: The incidence of fracture in a single-implant overdenture base increases in the region adjacent to the fulcrum implant. PURPOSE: The purpose of this in vitro study was to evaluate the effect of bidirectional woven electrical glass (E-glass) fiber reinforcements on the fatigue resistance of a simulated single LOCATOR-retained overdenture. MATERIAL AND METHODS: Test specimens with a centrally positioned metal housing for a LOCATOR stud attachment were fabricated from autopolymerizing acrylic resin. Specimens for the control group were fabricated without glass fiber reinforcements. The 4L group specimens had 4 layers of E-glass fiber weaves and were divided according to the fiber location into the following 3 subgroups: 4L-A with 4 fiber layers above the metal housing; 4L-N with 4 fiber layers adjacent to the metal housing; and 4L-A+4L-N with 4 fiber layers above and 4 fiber layers adjacent to the housing. Specimens were stored in distilled water for 1 week at 23 °C before cyclic fatigue testing at 10 000 cycles by using a staircase approach (n=12). The results were analyzed with 1-way ANOVA and the Tukey multiple comparisons post hoc analysis (α=.05). A 2-way ANOVA (α=.05) was conducted to detect the effect of fatigue cyclic loading and the position of the fiber layers and their interaction on the fatigue resistance. RESULTS: The results of the investigated compressive fatigue limits for the test groups were 190 ±15.9 N for the control group, 265 ±15.9 N for the 4L-A subgroup, 220 ±15.9 N for the 4L-N subgroup, and 275 ±15.9 N for the 4L-A+4L-N subgroup. A nonsignificant difference was found for creep values between the control group and reinforced subgroups (P>.05). The postfatigue flexural strength values in the 4L-A and 4L-A+4L-N subgroups were significantly higher than those in the control group (P<.001) and the 4L-N subgroup (P=.004 and P=.005). However, no significant difference was found in postfatigue flexural strength between the control group and the 4L-N subgroup (P=.828). CONCLUSIONS: Placing 4 layers of bidirectional E-glass fiber weaves above the metal housing can increase the fatigue resistance and the postfatigue flexural strength of single LOCATOR-retained overdentures.


Assuntos
Revestimento de Dentadura , Vidro , Resinas Acrílicas , Análise do Estresse Dentário , Teste de Materiais , Estresse Mecânico
16.
Int J Oral Maxillofac Implants ; 34(2): 313-319, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30883614

RESUMO

PURPOSE: Good cell adhesion is an important prerequisite for soft tissue attachment on implant abutment or crown surfaces. The aim of this study was to evaluate the adhesion and proliferation of human epithelial cells on sol-gel-derived TiO2-coated and noncoated zirconia. MATERIALS AND METHODS: Altogether, 56 zirconia disks (Z-CAD, Metoxit) were fabricated for this study. Half of the disks were coated with a sol-gel-derived TiO2 coating (MetAlive, ID Creations). The rest of the disks were noncoated and formed the control group. Surface properties of the disks were characterized by contact angle measurements and surface free energy (SFE) calculation. The cell adhesion was tested by cultivating epithelial cells (20,000 cells/cm2) on the experimental disks for 1, 3, 6, and 24 hours, after which the fluorescence of the samples was measured (BioTek synergy HT). The amount of cells was detected by comparing the fluorescence value to the standard curve. In addition, the proliferation was studied by growing epithelial cells (25,000 cells/cm2) for 1, 3, and 7 days. The number of cells was calculated by defining the absorbance of the samples (Multiskan EX, Thermo Labsystems), followed by a comparison with the standard curve. Finally, the samples were processed for light microscopy. RESULTS: TiO2-coated disks were significantly more hydrophilic with higher total SFE than noncoated disks (P < .05). The amount of epithelial cells was greater on TiO2-coated disks than on controls after 24 hours (P < .05). Regarding cell proliferation, the difference was statistically significant (P < .05) on days 3 and 7. Light microscope evaluation confirmed viable cells, which were in immediate close contact with both substrate surfaces. The cell layers on the coated disks appeared to be more uniform and cell rich than the layers on noncoated disks. CONCLUSION: This study indicated that TiO2 coating improves epithelial cell attachment and proliferation on zirconia surfaces. This has good potential to enhance formation of the epithelial junction to the coated zirconia surfaces.


Assuntos
Adesão Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Implantes Dentários , Inserção Epitelial/efeitos dos fármacos , Células Epiteliais/citologia , Titânio/farmacologia , Zircônio , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Fibroblastos/citologia , Humanos , Próteses e Implantes , Propriedades de Superfície , Titânio/química
17.
J Mech Behav Biomed Mater ; 91: 202-211, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30594062

RESUMO

PURPOSE: The purpose of this systematic review was to investigate the effect of reinforcement on the mechanical behaviour of implant overdenture (IOD) bases and its cumulative biological effect on the underlying supporting structures (implants and the residual ridge). MATERIAL AND METHODS: The required documents were collected electronically from PubMed and Web of Science databases targeting papers published in English that focused on denture base reinforcement for IOD prostheses in order to recognize the principal outcomes of reinforcement on the mechanical and biological properties of overdentures. Such biological outcomes as: strains on implants, peri-implant bone loss, residual ridge resorption, and strain on the residual alveolar ridge. RESULTS: A total of 269 citations were identified. After excluding any repeated articles between databases and the application of exclusion and inclusion criteria, only 13 publications fulfilled the inclusion criteria. Three publications investigated the mechanical properties of fibre and/or metal-reinforced implant overdentures while another 3 articles investigated the effect of metal reinforcement on stress distribution and strains transmitted to the underlying implants. In addition, 3 in vitro studies investigated the effect of metal reinforcement on overdenture base strain and stresses. Stress distribution to the residual ridge and strain characteristics of the underlying tissues were investigated by 2 in vitro studies. Five clinical studies performed to assist the clinical and prosthetic maintenance of metal-reinforced IOD were included. Data concerning denture base fracture, relining, peri-implant bone loss, probing depth, and implant survival rates during the functional period were extracted and considered in order to evaluate the mechanical properties of the denture base, residual ridge resorption and implant preservation rates, respectively. CONCLUSION: The use of a denture base reinforcement can reduce the fracture incidence in IOD bases by enhancing their flexural properties and reducing the overdenture base deformation. Strains on the underlying supporting structures of overdenture prostheses including dental implants and the residual ridge can be decreased and evenly distributed using a metal reinforcement.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Fenômenos Mecânicos , Fenômenos Biomecânicos , Humanos
18.
J Prosthet Dent ; 120(4): 558-564, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29961629

RESUMO

STATEMENT OF PROBLEM: Acrylic resin overdenture bases usually fracture because of stress concentrations at the area of the abutments. PURPOSE: The purpose of this study was to evaluate the reinforcing effect of bidirectional woven electrical glass (E-glass) fiber weaves with a different number of layers and different locations on the load-bearing capacity of simulated Locator-retained overdenture specimens. MATERIAL AND METHODS: Test specimens with a centrally located metal housing for a Locator stud attachment were fabricated from autopolymerizing acrylic resin (polymethylmethacrylate based) and reinforced with bidirectional woven E-glass fiber layers. The control group specimens were fabricated without fiber reinforcement. The 2L group had 2 layers of E-glass fiber weaves and was divided according to the fiber location within the specimens as follows: 2L-A subgroup with 2 fiber layers above the metal housing; 2L-N subgroup with 2 fiber layers adjacent to the housing; and 2L-A+2L-N subgroup with 2 fiber layers above and 2 fiber layers adjacent to the housing. The 4L group had 4 layers of E-glass fiber weaves and was divided according to the fiber location as follows: 4L-A subgroup with 4 fiber layers above the housing; 4L-N subgroup with 4 fiber layers adjacent to the housing; and 4L-A+4L-N subgroup with 4 fiber layers above and 4 fiber layers adjacent to the housing. Dry specimens were submitted to a 3-point static loading test, and the mean flexural strength, flexural modulus, and strain values were analyzed with 1-way ANOVA and Tukey post hoc tests (α=.05). Two-way ANOVA was conducted to detect the influence of the number and location of the reinforcing layers (α=.05). RESULTS: The results revealed a significant difference (P<.001) in flexural strength values between the control group (92.4 ±14 MPa) and the 2 subgroups, 4L-A (116 ±7.3 MPa) and 4L-A+4L-N (117.1 ±6 MPa), with a significant effect only from the number of the reinforcing layers (P<.001) and not the location (P=.153). No significant differences were found with flexural modulus (P=.195) and strain values (P=.174) among the tested groups. CONCLUSIONS: The load-bearing capacity of a Locator-retained overdenture can be significantly increased by placing 4 layers of bidirectional woven E-glass fiber weaves either only above the metal housing or in both locations above and adjacent to the metal.


Assuntos
Prótese Total , Revestimento de Dentadura , Projeto do Implante Dentário-Pivô , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Vidro , Humanos , Técnicas In Vitro , Suporte de Carga
19.
Clin Exp Dent Res ; 4(3): 78-85, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29955391

RESUMO

This study was designed to investigate the effect of nanostructured TiO2 coatings on human gingival fibroblast and to explore the influence of ultraviolet (UV) light on surface wettability and cellular response. Ti-6Al-4V titanium alloy discs (n = 96) were divided into three groups: a sol-gel-derived MetAlive™ (MA) coating; hydrothermal (HT) coating; and a non-coated (NC) group. Forty-eight titanium substrates were further treated with UV light for 15 min. The water contact angles of the substrates were measured using the sessile drop method. Human gingival fibroblasts were used to evaluate the cell adhesion strength and cell proliferation on experimental surfaces. The strength of cell adhesion against enzymatic detachment was studied after 6 hr of adhesion using gentle trypsinization for 15 min at room temperature. A fluorescence microscope was used for cell imaging (Zeiss-stereo-lumar-v12), and images were analyzed for cell counting, and the percentage of detached cells were calculated. The proliferation of cultured cells up to 10 days was determined according to the cell activity using Alamar Blue™assay. The HT group had the lowest contact angle value (31.1°) followed by MetAlive™ (35.3°), whereas the NC group had the highest contact angle (50.3°). After UV light treatment, all surfaces become considerably more hydrophilic. There was a significant difference in the amount of adherent cells between sol-gel and HT groups when compared with the NC group (p < .05) with detachment percentages of 35.8%, 36.4%, and 70.7%, respectively. All substrate types showed an increase in cell proliferation rate until 10 days. It can be concluded that nanostructured titanium oxide implant surfaces, obtained by sol-gel and HT coating methods, enhance the surface wettability and improve human gingival fibroblast function in terms of adhesion and proliferation rate when compared with non-coated surfaces. UV light treatment clearly enhances the wettability of all titanium surfaces.

20.
J Oral Implantol ; 44(5): 330-334, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29763362

RESUMO

New monolithic zirconia materials can be used to fabricate full-contour fixed dental prostheses with the computer-aided design/computer-aided manufacturing (CAD/CAM) method. The aim of this study was to examine the fracture strength and precision of fit of screw-retained monolithic zirconia crowns made directly on implants or by cementing on prefabricated titanium (Ti) bases. Monolithic screw-retained implant crowns (n = 6) were produced by CAD/CAM method using partially (PSZ) and fully stabilized (FSZ) zirconia. Industrially produced zirconia crowns were used as a reference. A lateral incisor study model was made onto an implant replica. Crowns were produced either directly on the implant or through cementing on a prefabricated titanium base (PSZ+Ti, FSZ+Ti). The crowns were tightened to implant replicas with a torque of 35 Ncm. The gap between the replica and the abutment or crown was measured from ×400 scanning electron microscope images for precision of fit. Mechanical testing until failure was completed with a universal testing machine with loading angle of 45°. Statistical analysis was performed (analysis of variance). Mean (±SD) failure loads were 259 ± 23 (PSZ), 140 ± 13 (FSZ), 453 ± 25 (PSZ+Ti), 439 ± 41 (FSZ+Ti), and 290 ± 39 (Procera). Mean (±SD) gap values were 2.2 ± 0.2 (PSZ), 2.5 ± 1.0 (FSZ), 7.0 ± 1.0 (PSZ+Ti), 7.7 ± 1.6 (FSZ+Ti), and 6.7 ± 1.7 (Procera). Monolithic zirconia crowns with a Ti base clearly show higher fracture strengths than the crowns fixed directly on the implant surface. Better marginal fit can be achieved with direct zirconia crowns than with crowns on a titanium base or industrially produced zirconia crowns.


Assuntos
Desenho Assistido por Computador , Dente Suporte , Resistência à Flexão , Zircônio , Coroas , Análise do Estresse Dentário , Teste de Materiais , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA