Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 31(10): 2572-2581, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32648326

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are characterized as a wider and more continuous than that after conventional radiofrequency catheter ablation (RFCA) without the contact force (CF)-sensing technology. However, the impact on the lesion characteristics of ablation with a CF-sensing catheter has not been well discussed. We sought to assess the lesions using late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) and to compare the differences between the two groups (CB group vs. RF group). METHODS: A total of 30 consecutive patients who underwent PVI were enrolled (CB group, 18; RF group, 12). The RF applications were delivered with a target lesion size index (LSI) of 5. The PVI lesions were assessed by LGE-MRI 3 months after the PVI. The region around the PV was divided into eight segments: roof, anterior-superior, anterior carina, anterior inferior, bottom, posterior inferior, posterior carina, and posterior superior segment. The lesion width and visual gap of each segment were compared between the two groups. The visual gaps were defined as no-enhancement site of >4 mm. RESULTS: The mean LSI was 4.7 ± 0.7. The lesion width was significantly wider but the visual gaps were more frequently documented at the bottom segment of right PV in the CBA group (lesion width: 8.1 ± 2.2 vs. 6.3 ± 2.2 mm; p = .032; visual gap at the bottom segment or right PV: 39% vs. 0%; p = .016). CONCLUSIONS: The PVI lesion was wider after CBA, while the visual gaps were fewer after RFCA with a CF-sensing catheter.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Radiofrequência , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Meios de Contraste , Criocirurgia/efeitos adversos , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 30(10): 1830-1840, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31310389

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are wide and continuous, however, the distribution can depend on the pulmonary vein (PV) size. We sought to assess the relationship between the lesion distribution and PV size after CBA and hotballoon ablation (HBA). METHODS AND RESULTS: A total of 80 consecutive patients who underwent PVI were enrolled (40 with CBA). The lesions were visualized by late-gadolinium enhancement magnetic resonance imaging. The lesion width, lesion gaps, and distance from the PV ostium (PVos) to distal lesion edge (DLE) were assessed. If the DLE extended inside the PV, the value was expressed as a negative value. Although the lesion width was significantly wider in the CB group (7.8 ± 2.0 vs 4.9 ± 1.0 mm, P < .001), the number of lesion gaps was significantly less in the HB group (2.9 ± 2.4 vs 1.3 ± 1.4 gaps, P = .001). The distance from the PVos to DLE was a negative value in both groups, but the impact was significantly greater (-1.5 ± 1.8 vs -0.2 ± 1.2 mm, P < .001) and negatively correlated with PV size in the CB group, but not in HB group (r = -0.27, P = .007). The AF recurrence 12 months after the procedure did not differ (5 [12.5%] of 40 in the CB group vs 4 [10%] of 40 in the HB group, P = .695). CONCLUSIONS: The PVI lesions after HBA were characterized by (a) narrower, but (b) more continuous, (c) smaller lesion inside the PV, and (d) irrespective of PV size as compared to that after CBA.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Meios de Contraste/administração & dosagem , Criocirurgia , Imageamento por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Arrhythm ; 34(2): 158-166, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29657591

RESUMO

Background: Rhythm outcomes after the pulmonary vein isolation (PVI) using the cryoballoon (CB) are reported to be excellent. However, the lesions after CB ablation have not been well discussed. We sought to characterize and compare the lesion formation after CB ablation with that after radiofrequency (RF) ablation. Methods: A total of 42 consecutive patients who underwent PVI were enrolled (29 in the CB group and 13 in the RF group). The PVI lesions were assessed by late gadolinium enhancement magnetic resonance imaging 1-3 months after the PVI. The region around the PVs was divided into eight segments: roof, anterior-superior, anterior-carina, anterior-inferior, bottom, posterior-inferior, posterior-carina, and posterior-superior segment. The lesion width and lesion gap in each segment were compared between the two groups. Lesion gaps were defined as no-enhancement sites of >4 mm. Results: As compared to the RF group, the overall lesion width was significantly wider and lesion gaps significantly fewer at the anterior-superior segment of the left PV (LAS) and anterior-inferior segment of the right PV (RAI) in the CB group (lesion width: 8.2 ± 2.2 mm vs 5.6 ± 2.0 mm, P = .001; lesion gap at LAS: 7% vs 38%, P = .02; lesion gap at RAI: 7% vs 46%, P = .006). Conclusions: The PVI lesions after CB ablation were characterized by extremely wider and more continuous lesions than those after RF ablation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA