Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Front Plant Sci ; 13: 1024144, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36743553

RESUMO

Rice is susceptible to abiotic stresses such as drought stress. To enhance drought resistance, elucidating the mechanisms by which rice plants adapt to intermittent drought stress that may occur in the field is an important requirement. Roots are directly exposed to changes in the soil water condition, and their responses to these environmental changes are driven by photosynthates. To visualize the distribution of photosynthates in the root system of rice plants under drought stress and recovery from drought stress, we combined X-ray computed tomography (CT) with open type positron emission tomography (OpenPET) and positron-emitting tracer imaging system (PETIS) with 11C tracer. The short half-life of 11C (20.39 min) allowed us to perform multiple experiments using the same plant, and thus photosynthate translocation was visualized as the same plant was subjected to drought stress and then re-irrigation for recovery. The results revealed that when soil is drier, 11C-photosynthates mainly translocated to the seminal roots, likely to promote elongation of the root with the aim of accessing water stored in the lower soil layers. The photosynthates translocation to seminal roots immediately stopped after rewatering then increased significantly in crown roots. We suggest that when rice plant experiencing drought is re-irrigated from the bottom of pot, the destination of 11C-photosynthates translocation immediately switches from seminal root to crown roots. We reveal that rice roots are responsive to changes in soil water conditions and that rice plants differentially adapts the dynamics of photosynthates translocation to crown roots and seminal roots depending on soil conditions.

2.
New Phytol ; 232(5): 1974-1984, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34498274

RESUMO

Rice (Oryza sativa) plants have porous or hollow organs consisting of aerenchyma, which is presumed to function as a low-resistance diffusion pathway for air to travel from the foliage above the water to submerged organs. However, gas movement in rice plants has yet to be visualized in real time. In this study involving partially submerged rice plants, the leaves emerging from the water were fed nitrogen-13-labeled nitrogen ([13 N]N2 ) tracer gas, and the gas movement downward along the leaf blade, leaf sheath, and internode over time was monitored. The [13 N]N2 gas arrived at the bottom of the plant within 10 min, which was 20 min earlier than carbon-11 photoassimilates. The [13 N]N2 gas movement was presumably mediated by diffusion along the aerenchyma network from the leaf blade to the root via nodes functioning as junctions, which were detected by X-ray computed tomography. These findings imply the diffusion of gas along the aerenchyma, which does not consume energy, has enabled plants to adapt to aquatic environments. Additionally, there were no major differences in [13 N]N2 gas movement between paddy rice and deepwater rice plants, indicative of a common aeration mechanism in the two varieties, despite the difference in their response to flooding.


Assuntos
Oryza , Oxigênio , Pressão Parcial , Folhas de Planta , Raízes de Plantas , Água
3.
Sensors (Basel) ; 20(9)2020 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-32357411

RESUMO

Compton cameras can simultaneously detect multi-isotopes; however, when simultaneous imaging is performed, crosstalk artifacts appear on the images obtained using a low-energy window. In conventional single-photon emission computed tomography, a dual energy window (DEW) subtraction method is used to reduce crosstalk. This study aimed to evaluate the effectiveness of employing the DEW technique to reduce crosstalk artifacts in Compton images obtained using low-energy windows. To this end, in this study, we compared reconstructed images obtained using either a photo-peak window or a scatter window by performing image subtraction based on the differences between the two images. Simulation calculations were performed to obtain the list data for the Compton camera using a 171 and a 511 keV point source. In the images reconstructed using these data, crosstalk artifacts were clearly observed in the images obtained using a 171 keV photo-peak energy window. In the images obtained using a scatter window (176-186 keV), only crosstalk artifacts were visible. The DEW method could eliminate the influence of high-energy sources on the images obtained with a photo-peak window, thereby improving quantitative capability. This was also observed when the DEW method was used on experimentally obtained images.

4.
Phys Med Biol ; 65(5): 05LT01, 2020 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-31323647

RESUMO

The Compton camera can simultaneously acquire images of multiple isotopes injected in a body; therefore, it has the potential to introduce a new subfield in the field of biomedical imaging applications. The objective of this study is to assess the ability of a prototype semiconductor-based silicon/cadmium telluride (Si/CdTe) Compton camera to simultaneously image the distributions of technetium (99mTc)-dimercaptosuccinic acid (DMSA) (141 keV emission) and 18F-fluorodeoxyglucose (FDG) (511 keV emission) injected into a human volunteer. 99mTc-DMSA and 18F-FDG were injected intravenously into a 25-year-old male volunteer. The distributions of 99mTc-DMSA and 18F-FDG were simultaneously made visible by setting a specified energy window for each radioisotope. The images of these radiopharmaceuticals acquired using the prototype Compton camera were superimposed onto computed tomography images for reference. The reconstructed image showed that 99mTc-DMSA had accumulated in both kidneys, which is consistent with the well-known diagnostic distribution determined by clinical imaging via single-photon emission computed tomography. In the 18F-FDG image, there is broad distribution around the liver and kidneys, which was expected based on routine clinical positron emission tomography imaging. The current study demonstrated for the first time that the Si/CdTe Compton camera was capable of simultaneously imaging the distributions of two radiopharmaceuticals, 99mTc-DMSA and 18F-FDG, in a human body. These results suggest that the Si/CdTe Compton camera has the potential to become a novel modality for nuclear medical diagnoses enabling multi-probe simultaneous tracking.


Assuntos
Fluordesoxiglucose F18 , Câmaras gama , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Ácido Dimercaptossuccínico Tecnécio Tc 99m , Adulto , Compostos de Cádmio , Humanos , Processamento de Imagem Assistida por Computador/métodos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Silício , Telúrio
5.
Phys Med ; 56: 1-9, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30527083

RESUMO

INTRODUCTION: We have been developing a medical imaging technique using a Compton camera, which is expected to reconstruct three-dimensional images. If the number of views is not sufficient, star-shaped artifacts (streak artifacts) could arise in cross-sectional images. Therefore, we estimated the point spread function (PSF) of cross-sectional Compton images and the effect of the number of views by Monte Carlo simulations and experimental studies. MATERIALS AND METHODS: A cross-sectional Compton image was reconstructed using a dataset comprising 719 view directions and PSF was analyzed using a radial distribution. The peak height, full width at half maximum (FWHM), background (BG), and residual sum of squares (RSS) were calculated from the obtained PSF. In addition, RSSs were plotted against the number of views to estimate the required number to suppress star-shaped artifacts. RESULTS: There was no correlation found between the number of views and both FWHM (16 mm) and peak/BG ratio (∼1 × 104). RSSs were reduced with the number of views and approached the minimum asymptotically. Correlation was observed between the required number of views and the number of Compton events used for image reconstruction. CONCLUSION: We determined the PSF of cross-sectional Compton images and the effect of the number of views on the images. The required number of views to suppress the star-shaped artifact is related to the square root of the number of Compton events used to reconstruct the image. From this study, we concluded that 21 or more views are required for clinical purposes.


Assuntos
Imageamento Tridimensional/métodos , Cintilografia/métodos , Simulação por Computador , Desenho de Equipamento , Radioisótopos de Flúor , Câmaras gama , Raios gama , Humanos , Método de Monte Carlo
6.
Phys Med Biol ; 63(20): 205006, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30222127

RESUMO

We have been developing a medical imaging technique using a Compton camera. This study evaluates the feasibility of clear imaging with 99mTc and 18F simultaneously, and demonstrates in vivo imaging with 99mTc and/or 18F. We used a Compton camera with silicon and cadmium telluride (Si/CdTe) semiconductors. We estimated the imaging performance of the Compton camera for 141 keV and 511 keV gamma rays from 99mTc and 22Na, respectively. Next, we simultaneously imaged 99mTc and 18F point sources to evaluate the cross-talk artifacts produced by a higher energy gamma-ray background. Then, in the in vivo experiments, three rats were injected with 99mTc-dimercaptosuccinic acid and/or 18F-fluorodeoxyglucose and imaged. The Compton images were compared with PET images. The rats were euthanized, and the activities in their organs were measured using a well counter. The energy resolution and spatial resolution were measured for the sources. No apparent cross-talk artifacts were observed in the practical-activity ratio (99mTc:18F = 1:16). We succeeded in imaging the distributions of 99mTc and 18F simultaneously, and the results were consistent with the PET images and well counter measurements. Our Si/CdTe Compton camera can thus work as a multi-tracer imager, covering various SPECT and PET probes, with less cross-talk artifacts in comparison to the conventional Anger cameras using a collimator. Our findings suggest the possibility of human trials.


Assuntos
Fluordesoxiglucose F18/metabolismo , Câmaras gama , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagem Corporal Total/métodos , Radioisótopos de Ítrio , Animais , Masculino , Ratos , Ratos Wistar
7.
Appl Radiat Isot ; 139: 238-243, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29864741

RESUMO

Astatine-211 is a promising radionuclide for targeted radiotherapy. It is required to image the distribution of targeted radiotherapeutic agents in a patient's body for optimization of treatment strategies. We proposed to image 211At with high-energy photons to overcome some problems in conventional planar or single-photon emission computed tomography imaging. We performed an imaging experiment of a point-like 211At source using a Compton camera, and demonstrated the capability of imaging 211At with the high-energy photons for the first time.


Assuntos
Astato/uso terapêutico , Cintilografia/instrumentação , Radioterapia/instrumentação , Partículas alfa/uso terapêutico , Simulação por Computador , Humanos , Método de Monte Carlo , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Fótons , Cintilografia/estatística & dados numéricos , Compostos Radiofarmacêuticos/uso terapêutico , Radioterapia/estatística & dados numéricos
8.
Phys Med Biol ; 63(4): 045016, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29235991

RESUMO

A feasibility study on the imaging of monochromatic carbon-ion beams for carbon-ion therapy was performed. The evaluation was based on Monte Carlo simulations and beam-irradiation experiments, using a pinhole x-ray camera, which measured secondary electron bremsstrahlung (SEB). The simulation results indicated that the trajectories of the carbon-ion beams with injection energies of 278, 249 and 218 MeV/u in a water phantom, were clearly imaged by measuring the SEB with energies from 30 to 60 keV, using a pinhole camera. The Bragg-peak positions for these three injection energies were located at the positions where the ratios of the counts of SEB acquisitions to the maximum counts were approximately 0.23, 0.26 and 0.29, respectively. Moreover, we experimentally demonstrated that it was possible to identify the Bragg-peak positons, at the positions where the ratios coincided with the simulation results. However, the estimated Bragg-peak positions for the injection energies of 278 and 249 MeV/u were slightly deeper than the expected positions. In conclusion, for both the simulations and experiments, we found that the 25 mm shifts in the Bragg-peak positions can be observed by this method.


Assuntos
Elétrons , Radioterapia com Íons Pesados/métodos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Raios X
9.
Sci Rep ; 7(1): 2110, 2017 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-28522868

RESUMO

In the field of nuclear medicine, single photon emission tomography and positron emission tomography are the two most common techniques in molecular imaging, but the available radioactive tracers have been limited either by energy range or difficulties in production and delivery. Thus, the use of a Compton camera, which features gamma-ray imaging of arbitrary energies from a few hundred keV to more than MeV, is eagerly awaited along with potential new tracers which have never been used in current modalities. In this paper, we developed an ultra-compact Compton camera that weighs only 580 g. The camera consists of fine-pixelized Ce-doped Gd3Al2Ga3O12 scintillators coupled with multi-pixel photon counter arrays. We first investigated the 3-D imaging capability of our camera system for a diffuse source of a planar geometry, and then conducted small animal imaging as pre-clinical evaluation. For the first time, we successfully carried out the 3-D color imaging of a live mouse in just 2 h. By using tri-color gamma-ray fusion images, we confirmed that 131I, 85Sr, and 65Zn can be new tracers that concentrate in each target organ.

10.
Rev Sci Instrum ; 88(1): 014301, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147655

RESUMO

The purpose of this study is to determine whether the main component of the low-energy (63-68 keV) particles emitted perpendicularly to the 12C beam from the 12C-irradiated region in a water phantom is secondary electron bremsstrahlung (SEB). Monte Carlo simulations of a 12C-beam (290 MeV/u) irradiated on a water phantom were performed. A detector was placed beside the water phantom with a lead collimator between the phantom and the detector. To move the Bragg-peak position, a binary filter was placed in an upper stream of the phantom. The energy distributions of the particles incident on the detector and those deposited in the detector were analyzed. The simulation was also performed with suppressed delta-ray and/or bremsstrahlung generation to identify the SEB components. It was found that the particles incident on the detector were predominantly photons and neutrons. The yields of the photons and energy deposition decreased with the suppression of SEB generation. It is concluded that one of the predominant components of the yields in the regions shallower than the Bragg-peak position is due to SEB generation, and these components become significantly smaller in regions deeper than the Bragg-peak position.

11.
Phys Med Biol ; 57(10): 2843-56, 2012 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-22513759

RESUMO

We describe a new method for estimating the beam range in heavy-ion radiation therapy by measuring the ion beam bremsstrahlung. We experimentally confirm that the secondary electron bremsstrahlung process provides the dominant bremsstrahlung contribution. A Monte Carlo simulation shows that the number of background photons from annihilation gamma rays is about 1% of the bremsstrahlung strength in the low-energy region used in our estimation (63-68 keV). Agreement between the experimental results and the theoretical prediction for the characteristic shape of the bremsstrahlung spectrum validates the effectiveness of our new method in estimating the ion beam range.


Assuntos
Radiometria/métodos , Raios gama/uso terapêutico , Método de Monte Carlo , Fótons/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA