Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Eng Technol ; 13(2): 219-233, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34453278

RESUMO

PURPOSE: Left atrial (LA) rapid AF activity has been shown to co-localise with areas of successful atrial fibrillation termination by catheter ablation. We describe a technique that identifies rapid and regular activity. METHODS: Eight-second AF electrograms were recorded from LA regions during ablation for psAF. Local activation was annotated manually on bipolar signals and where these were of poor quality, we inspected unipolar signals. Dominant cycle length (DCL) was calculated from annotation pairs representing a single activation interval, using a probability density function (PDF) with kernel density estimation. Cumulative annotation duration compared to total segment length defined electrogram quality. DCL results were compared to dominant frequency (DF) and averaging. RESULTS: In total 507 8 s AF segments were analysed from 7 patients. Spearman's correlation coefficient was 0.758 between independent annotators (P < 0.001), 0.837-0.94 between 8 s and ≥ 4 s segments (P < 0.001), 0.541 between DCL and DF (P < 0.001), and 0.79 between DCL and averaging (P < 0.001). Poorer segment organization gave greater errors between DCL and DF. CONCLUSION: DCL identifies rapid atrial activity that may represent psAF drivers. This study uses DCL as a tool to evaluate the dynamic, patient specific properties of psAF by identifying rapid and regular activity. If automated, this technique could rapidly identify areas for ablation in psAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Análise Espacial
2.
J Cardiovasc Electrophysiol ; 30(9): 1464-1474, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31211473

RESUMO

BACKGROUND: Conventional mapping techniques during atrial fibrillation (AF) are difficult to apply because of cycle length irregularity. Mapping studies are usually restricted to short durations of AF in limited regions because of the laborious manual annotation of local activation time (LAT). The purpose of this study was to test an automated algorithm to map activation during AF, with comparable accuracy to manual annotation. METHODS: Left atrial (LA) mapping was performed using a 20-pole double loop catheter (AFocusII) in 30-second data segments from 16 patients. The new algorithm (RETRO-Mapping) was designed to detect wavefront propagation between electrodes, and display activating wavefronts on a two-dimensional representation of the catheter. Activation patterns were validated against their bipolar electrograms and with isochronal maps. The mapping protocol was approved by the research ethics committee (13/LO1169 and 14/LO1367). RESULTS: During AF, uniform wavefront activation direction (mean ± SD, degrees) from manually constructed isochronal maps was comparable to RETRO-Propagation Map (RETRO-PM) and RETRO-Automated Direction (RETRO-AD): 1 ± 6.9 for RETRO-PM; and 2 ± 6.6 for RETRO-AD. There was no significant difference in activation direction assigned to 1373 uniform wavefronts during AF when comparing RETRO-PM with RETRO-AD (Bland-Altman mean difference: -0.1 degrees; limits of agreement: -8.0 to 8.3; 95% CI -0.4 to 0.2; (r = 0.01) R2 = < 0.005; P = .77). CONCLUSION: We have developed and validated a new technique to map activation during AF. This technique shows comparable accuracy to that of conventional isochronal mapping with careful manual adjustment of LAT.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/fisiopatologia , Processamento de Sinais Assistido por Computador , Potenciais de Ação , Adulto , Idoso , Fibrilação Atrial/fisiopatologia , Automação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA