Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
BMJ Case Rep ; 20172017 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-29066633

RESUMO

A 74-year-old woman presented with an 8-year history of unilateral swelling of her right lower limb, which was thought to be 'idiopathic' lymphoedema until she noticed a painless swelling in her right groin. Physical examination showed a painless, non-pulsatile, deep-seated mass in her right proximal thigh with significant lymphoedema distally. MRI scan showed a large mass at her right inguinal region, involving the common femoral vein. Histological examination on complete excision revealed leiomyosarcoma. It is important to exclude proximal obstructive lesion before making a diagnosis of unilateral idiopathic lower limb lymphoedema.


Assuntos
Leiomiossarcoma/patologia , Linfedema/etiologia , Neoplasias Vasculares/patologia , Idoso , Feminino , Veia Femoral/patologia , Virilha/diagnóstico por imagem , Virilha/patologia , Humanos , Leiomiossarcoma/diagnóstico por imagem , Leiomiossarcoma/cirurgia , Extremidade Inferior/patologia , Linfedema/diagnóstico , Imageamento por Ressonância Magnética , Doenças Raras , Coxa da Perna/patologia , Resultado do Tratamento , Neoplasias Vasculares/diagnóstico por imagem , Neoplasias Vasculares/cirurgia
2.
J Endovasc Ther ; 23(1): 229-32, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26564914

RESUMO

PURPOSE: To report 2 cases of type IIIb endoleak with the Endurant stent-graft and postulate the cause for the events. CASE REPORT: A type IIIb endoleak was diagnosed at open conversion for a ruptured aneurysm 4 years after implantation of an Endurant stent-graft. In the other case, the endoleak was diagnosed at angiography 4 years after the Endurant stent-graft was implanted; the stent-graft was relined. In both cases the fabric hole was in the body of the stent-graft at the level of the top of the contralateral limb. CONCLUSION: The cause of the type IIIb endoleaks in these cases was fabric erosion likely due to interaction between the bare metal at the top of the contralateral limb and the fabric of the stent-graft body.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/etiologia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Desenho de Prótese , Reoperação , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
J Endovasc Ther ; 21(5): 723-7, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25290802

RESUMO

PURPOSE: To present confirmed cases of type IIIb endoleak in second and third-generation stent-grafts used for endovascular aneurysm repair (EVAR). CASE REPORTS: Four patients developed type IIIb endoleak caused by fabric tears between 4 and 13 years following their initial EVAR. Three patients presented with rupture and one with aneurysm expansion of unknown cause. In each case, the type IIIb endoleak was confirmed at open surgery after imaging proved non-diagnostic. Only one patient survived. Had the cause for the expansion or ruptures been found prior to open reintervention, relining of the stent-graft may have been possible. CONCLUSION: Type IIIb endoleak remains difficult to diagnose. Avoidance of the high mortality associated with open secondary intervention requires a high degree of suspicion and it should be considered in any post-EVAR aneurysm expansion without an obvious cause.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Ruptura Aórtica/etiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Remoção de Dispositivo , Endoleak/diagnóstico , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Evolução Fatal , Humanos , Masculino , Desenho de Prótese , Reoperação , Stents , Falha de Tratamento
4.
J Vasc Surg ; 60(2): 418-27, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24657293

RESUMO

BACKGROUND: Meta-analysis supports patch angioplasty after carotid endarterectomy (CEA); however, studies indicate considerable variation in practice. The hemodynamic effect of a patch is unclear and this study attempted to elucidate this and guide patch width selection. METHODS: Four groups were selected: healthy volunteers and patients undergoing CEA with primary closure, trimmed patch (5 mm), or 8-mm patch angioplasty. Computer-generated three-dimensional models of carotid bifurcations were produced from transverse ultrasound images recorded at 1-mm intervals. Rapid prototyping generated models for flow visualization studies. Computational fluid dynamic studies were performed for each model and validated by flow visualization. Mean wall shear stress (WSS) and oscillatory shear index (OSI) maps were created for each model using pulsatile inflow at 300 mL/min. WSS of <0.4 Pa and OSI >0.3 were considered pathological, predisposing to accretion of intimal hyperplasia. The resultant WSS and OSI maps were compared. RESULTS: The four groups comprised 8 normal carotid arteries, 6 primary closures, 6 trimmed patches, and seven 8-mm patches. Flow visualization identified flow separation and recirculation at the bifurcation increased with a patch and was related to the patch width. Computational fluid dynamic identified that primary closure had the fewest areas of low WSS or elevated OSI but did have mild common carotid artery stenoses at the proximal arteriotomy that caused turbulence. Trimmed patches had more regions of abnormal WSS and OSI at the bifurcation, but 8-mm patches had the largest areas of deleteriously low WSS and high OSI. Qualitative comparison among the four groups confirmed that incorporation of a patch increased areas of low WSS and high OSI at the bifurcation and that this was related to patch width. CONCLUSIONS: Closure technique after CEA influences the hemodynamic profile. Patching does not appear to generate favorable flow dynamics. However, a trimmed 5-mm patch may offer hemodynamic benefits over an 8-mm patch and may be the preferred option.


Assuntos
Angioplastia , Artérias Carótidas/cirurgia , Doenças das Artérias Carótidas/cirurgia , Endarterectomia das Carótidas , Hemodinâmica , Técnicas de Fechamento de Ferimentos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Angioplastia/instrumentação , Velocidade do Fluxo Sanguíneo , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiopatologia , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/fisiopatologia , Simulação por Computador , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Fluxo Pulsátil , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estresse Mecânico , Resultado do Tratamento , Ultrassonografia , Técnicas de Fechamento de Ferimentos/efeitos adversos
5.
J Vasc Surg ; 57(6): 1543-52, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23541544

RESUMO

OBJECTIVE: This article reports the incidence, timing, and related sequelae for proximal and distal migration of the Zenith Fenestrated AAA Endovascular Graft (Cook Medical, Bloomington, Ind) used to treat abdominal aortic aneurysms. METHOD: A prospectively maintained database at a tertiary referral hospital was used to identify 83 patients who underwent endovascular repair using the Zenith fenestrated stent graft. Inclusion criteria included a postoperative computed tomography (CT) scan within 6 weeks of implantation and at least one additional follow-up CT scan (>5 months) available electronically at our institution. Eligible patients underwent assessment of stent graft migration using a CT-based central luminal line (CLL) technique. The proximal and distal margins of the stent graft were measured using CLLs relative to vascular landmarks on all available follow-up CT scans. Migration was defined as stent graft movement ≥4 mm. RESULTS: Fifty-five patients were included in this study, mean age was 74 ± 7 years, and 89% were men. Mean preoperative aneurysm diameter was 67 ± 9 mm. In these 55 patients, fenestrations were applied to 162 target vessels with the commonest design accommodating two renal arteries (RAs) and the superior mesenteric artery (SMA). Median follow-up was 24 (range, 5-97) months; 80% of patients (n = 44) had both the proximal and two distal attachment sites assessed for evidence of migration. Twelve iliac limbs in 11 patients were excluded from analysis due to occlusion of one internal iliac artery precluding CLL assessment (n = 7), or image quality issues (n = 5). Using CLLs and based on those patients who exhibited migration, the median proximal and distal migration distances were +5.0 (range, +4.0 to +8.1) mm and -5.0 (range, -4.3 to -21.3) mm, respectively. Kaplan-Meier analysis for proximal migration revealed migration rates of 14% and 22% at 12 and 36 months, respectively. Distal migration rates were lower at 3% and 8%, respectively. There have been no incidences of late rupture or open conversion. Of the patients with proximal migration, two patients lost a single target vessel (two RAs) and three patients were reported to have target vessel stenosis (two SMAs, one RA). These cases did not require reintervention. CONCLUSIONS: Both suprarenal fabric extension and visceral artery stenting are known to provide additional fixation for fenestrated aortic stent grafts. Despite this, minor proximal migration still occurs in up to one quarter of fenestrated endovascular repair patients by 4 years. We believe this is mainly due to the engagement of the barbs of the anchoring stent. Distal migrations occur with lower frequency.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Migração de Corpo Estranho/etiologia , Stents/efeitos adversos , Idoso , Feminino , Migração de Corpo Estranho/complicações , Migração de Corpo Estranho/epidemiologia , Humanos , Incidência , Masculino , Estudos Prospectivos , Desenho de Prótese
6.
J Vasc Surg ; 57(2): 362-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23044256

RESUMO

BACKGROUND: Abdominal aortic aneurysms that are unsuitable for a standard endovascular repair (EVAR) could be considered for fenestrated endovascular repair (f-EVAR). The aim of this study was to conduct a risk-adjusted retrospective concurrent cohort comparison of f-EVAR and open repair for such aneurysms. METHODS: All patients who underwent repair of an abdominal aortic aneurysm that was unsuitable for a standard EVAR due to inadequate neck within one institution between January 2006 and December 2010 were identified. Case notes were retrieved for clinical data, Vascular Physiological and Operative Severity Score for enUmeration of Mortality and Morbidity (V-POSSUM) score, and aneurysm morphology. Computed tomography scans were reviewed to establish aneurysm morphology. RESULTS: A total of 107 patients were identified. The open surgery cohort included 54 patients (35 men) who were a median age of 72 years (interquartile range [IQR], 9.5; range, 60-86 years). The aortic cross-clamp was infrarenal in 20 patients, suprarenal or above in 21, and inter-renal in eight. Postoperatively, 63 major complications were noted in 30 patients, nine of whom required 16 reinterventions. Cumulative hospital stay of the cohort was 1170 days (median, 12; IQR, 13; range, 1-205 days) of which 234 days (median, 28; IQR, 36; range, 1-77 days) were in the intensive therapy unit (ITU). Perioperative mortality was 9.2% (n = 5), exactly as estimated by V-POSSUM. The f-EVAR cohort included 53 patients (47 men) who were a median age of 76 years (IQR, 11.50; range, 55-87 years). Two fenestrations and one scallop was the most frequent configuration (n = 31). Postoperatively, 37 major complications were noted in 18 patients, six requiring reintervention. Hospital stay was 559 days (median, 7; IQR, 4.5; range, 4-64 days), of which 31 days (median, 4; IQR, 10.5; range, 1-15 days) were in the ITU. Two patients died perioperatively (3.7%), resulting in an observed crude absolute risk reduction of 5.5% compared with open repair. The V-POSSUM estimated perioperative death in five patients (9.4%) in the f-EVAR cohort. In a hypothetic scenario of the f-EVAR cohort undergoing open repair, V-POSSUM estimated seven deaths (13.2%), resulting in an estimated risk-adjusted absolute risk reduction due to f-EVAR of 9.5%. CONCLUSIONS: In this group of patients, f-EVAR reduced mortality and morbidity substantially compared with open repair and also reduced total hospital stay and ITU utilization.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Inglaterra , Feminino , Mortalidade Hospitalar , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
J Endovasc Ther ; 18(6): 797-801, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22149229

RESUMO

PURPOSE: To measure the stiffness of commonly used "stiff" guidewires in terms of their flexural modulus, an engineering parameter related to bending stiffness. METHODS: Eleven different intact stiff guidewires were selected to undergo a 3-point bending test performed using a tensile testing machine. Testing was performed on 3 new and intact specimens of each guidewire at 10 locations along the wire's length, excluding the floppy tip. The flexural modulus (in gigapascals, GPa) was calculated from the results of the bending test. RESULTS: The flexural modulus of the plain Amplatz wire was 9.5 GPa compared to 11.4 to 14.5 GPa for the "heavy duty" wires. Within the Amplatz family of guidewires, the flexural modulus was 17 GPa for the "stiff," 29.2 GPa for the "extra stiff," 60.3 GPa for the "super stiff," and 65.4 GPa for the "ultra stiff." The Backup Meier measured 139.6 GPa and the Lunderquist Extra Stiff 158.4 GPa. CONCLUSION: The Instructions for Use of some endovascular devices specify a wire type selected from a range of undefined "stiffness" descriptors. These descriptors have little correlation with the measured flexural modulus. Two guidewires with the description "extra stiff" can have a 5-fold difference in flexural modulus. We recommend that guidewire catalogues and packaging include the flexural modulus and that device manufacturers amend their Instructions for Use accordingly.


Assuntos
Procedimentos Endovasculares/instrumentação , Teste de Materiais , Maleabilidade , Prótese Vascular
8.
Vasc Endovascular Surg ; 45(7): 665-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21821637

RESUMO

INTRODUCTION: Soft tissue malignancy encasing axial vessels presents a surgical challenge when the goal is limb-preserving radical excision. REPORT: We describe a case where limb-preserving resection of a myxoid liposarcoma involving the femoral vessels was successfully performed in the absence of autologous superficial vein for vascular reconstruction. The proximal ipsilateral superficial femoral artery was harvested as an autograft for venous reconstruction, with the arterial defect bridged using a polytetrafluoroethylene interposition graft. DISCUSSION: This technique may be selectively extended to other indications where limb viability is dependent upon availability of a high-quality graft, and conventional conduits are either unavailable or unreliable.


Assuntos
Artéria Femoral/transplante , Veia Femoral/cirurgia , Lipossarcoma Mixoide/cirurgia , Neoplasias de Tecidos Moles/cirurgia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Veia Femoral/patologia , Humanos , Lipossarcoma Mixoide/patologia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Politetrafluoretileno , Desenho de Prótese , Neoplasias de Tecidos Moles/patologia , Tomografia Computadorizada por Raios X , Transplante Autólogo , Resultado do Tratamento
11.
J Vasc Surg ; 36(1): 150-7, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12096273

RESUMO

OBJECTIVE: Migration and proliferation of vascular smooth muscle cells (SMCs) contributes to intimal hyperplasia in saphenous vein (SV) bypass grafts, which leads to patency-threatening stenosis. Evidence for the involvement of basement membrane-degrading matrix metalloproteinases (MMPs) and growth factors in mediating SMC migration and proliferation has been presented in a number of in vitro and in vivo models. 3-Hydroxy-3 methylglutaryl CoA reductase inhibitors (statins) are widely used in patients with atherosclerosis and are claimed to have additional effects beyond cholesterol reduction. We therefore examined the effects of simvastatin, a commonly prescribed statin, on the proliferation and migration of cultured human SV SMC and on neointima formation and MMP activity in human SV organ cultures. To clarify its mode of action, we studied in parallel the effects of a specific MMP inhibitor, marimastat. STUDY DESIGN: Human SV specimens were obtained from patients who underwent coronary artery bypass grafting, and were cultured for 14 days in the presence of three concentrations of simvastatin and subsequently processed for measurement of MMP activity and neointimal thickness measurements. Cultured SV SMCs were used to construct growth curves in the presence of 10% fetal calf serum or 10% fetal calf serum supplemented with simvastatin or marimastat. Migration through a Matrigel basement-membrane matrix (invasion) was quantified with modified Boyden chambers. RESULTS: Simvastatin dose dependently reduced neointima formation (P =.004) in association with reduced MMP-9 activity (P =.03). SMC proliferation and invasion also were inhibited with simvastatin (P <.007 and P <.009, respectively). Marimastat dose dependently inhibited SMC invasion (P <.001) but importantly had no effect on SMC proliferation (P >.36). CONCLUSION: For effective control of neointimal development in vivo, a pharmacologic strategy should inhibit both SMC migration and proliferation. The ancillary properties of 3-Hydroxy-3 methylglutaryl CoA reductase inhibitors typified by simvastatin may be important in this regard.


Assuntos
Inibição de Migração Celular , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Músculo Liso Vascular/citologia , Músculo Liso Vascular/efeitos dos fármacos , Veia Safena/efeitos dos fármacos , Sinvastatina/administração & dosagem , Túnica Íntima/citologia , Túnica Íntima/efeitos dos fármacos , Relação Dose-Resposta a Droga , Avaliação de Medicamentos , Inibidores Enzimáticos/farmacologia , Humanos , Ácidos Hidroxâmicos/farmacologia , Metaloproteinase 2 da Matriz/efeitos dos fármacos , Metaloproteinase 9 da Matriz/efeitos dos fármacos , Ácido Mevalônico/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA