1.
N Engl J Med ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38767244

RESUMO

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
Artigo em Inglês | MEDLINE | ID: mdl-38757909

RESUMO

INTRODUCTION: Left bundle branch area (LBBA) pacing (LBBAP) has been proposed as an alternative therapy option in patients indicated for cardiac pacing to treat bradycardia or heart failure. The aim of the study was to evaluate the safety and effectiveness of LBBAP in patients implanted with a Tendril 2088 stylet-driven lead. METHODS: The international retrospective data collection registry included 11 sites from 5 countries globally. Patients with attempted implants of the Tendril lead in the LBBA were followed for at least 6 months post the implant attempt. The primary safety and efficacy endpoints were freedom from LBBAP lead-related serious adverse events and the composite of LBBA capture threshold of ≤2.0 V and R-wave amplitudes ≥5 mV (or ≥value at implant), respectively. RESULTS: Of 221 patients with attempted implants of the Tendril 2088 lead in the LBBA, 91.4% (202/221) had successful implants for LBBAP. Regardless of the LBBAP implant success, all patients were followed for at least 6 months (8.7 ± 7.3 months). Baseline characteristics: 44% female, 84% ≥65 years old, 34% coronary artery disease, and 86% of primary indications for pacemaker implant. Both primary safety and effectiveness endpoints were met (freedom from LBBAP lead-related serious adverse device effects of 99.5% and electrical performance composite success rate of 93%). The capture thresholds in LBBAP at implant and 6 months were 0.8 ± 0.3 V@0.4 ± 0.1 ms and 0.8 ± 0.3 V@0.4 ± 0.1 ms. The rate of patients with capture threshold rise ≥1 V was 1.5% through 6 months. The R-wave amplitudes in LBBAP at implant and 6 months were 9.3 ± 3.2 mV and 10.6 ± 3.0 mV. CONCLUSIONS: This large multicenter study demonstrates that the stylet-driven Tendril™ STS 2088 lead is safe and effective for LBBAP with high success and low complication rates.

3.
Nat Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760584

RESUMO

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .

5.
Card Electrophysiol Clin ; 16(2): 149-155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749634

RESUMO

Leadless pacemaker systems (LPs) were developed as an alternative to traditional transvenous permanent pacemakers (TV-PPM) due to increasing rates of device and procedural related complications, leading to a high-cost burden to our health-care system. LPs were initially indicated for single-chamber ventricular pacing; however, recent developments have allowed for dual-chamber pacing too. These systems have demonstrated highly successful implant rates with stable pacing performance. This article describes the retrieval techniques of the Micra LPs and ways to mitigate challenges encountered during the retrieval process.


Assuntos
Remoção de Dispositivo , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/métodos
6.
Cureus ; 16(2): e55035, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38550437

RESUMO

Acute interstitial nephritis (AIN) is characterized by an inflammatory infiltrate of the interstitium of the kidney, typically causing a decline in kidney function. Drug-induced AIN (also called allergic AIN) is a type of AIN. Common drugs associated with AIN are antibiotics, non-steroidal anti-inflammatory drugs (NSAIDs), and proton pump inhibitors (PPIs). A 59-year-old male with a history of recent laparoscopic robotic sleeve gastrectomy presented to the emergency department with five weeks of progressively worsening fatigue, nausea, and lightheadedness. Postoperatively, he was prescribed omeprazole 20 mg daily for gastric ulcer prophylaxis. His other home medications were amlodipine, atorvastatin, ursodiol, and budesonide-formoterol fumarate nebulizer. His physical examination was normal. Laboratory studies revealed elevated creatinine of 4.19 mg/dL from a baseline of 0.9 mg/dL two months ago and the presence of urine eosinophils. The etiology of this elevated creatinine was unclear, prompting CT-guided left renal biopsy. The biopsy showed diffuse interstitial inflammatory infiltration with numerous lymphocytes, a large number of neutrophils, and scattered eosinophils, consistent with the allergic type of AIN. Omeprazole was discontinued and the patient received a seven-day course of prednisone. Despite treatment, permanent renal damage occurred, and the patient's new baseline creatinine was 2.3 mg/dL. AIN caused by PPIs should be considered in the differential diagnosis of acute kidney injury (AKI). AIN can be difficult to diagnose, presenting with nonspecific symptoms, such as oliguria, malaise, nausea, and vomiting. An accurate and timely diagnosis can help prevent and treat worsening renal failure.

7.
BMJ Support Palliat Care ; 14(2): 171-177, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38490720

RESUMO

The scope of artificial intelligence (AI) in healthcare is promising, and AI has the potential to revolutionise the field of palliative care services also. Consumer satisfaction in palliative care is a critical aspect of providing high-quality end-of-life support. It encompasses various elements that contribute to a positive experience for both patients and their families. AI-based tools and technologies can help in early identification of the beneficiaries, reduce the cost, improve the quality of care and satisfaction to the patients with chronic life-limiting illnesses. However, it is essential to ensure that AI is used ethically and in a way that complements, rather than replaces, the human touch and compassionate care, which are the core components of palliative care. This article tries to analyse the scope and challenges of improving consumer satisfaction through AI-based technology in palliative care services.


Assuntos
Inteligência Artificial , Cuidados Paliativos , Humanos , Satisfação do Paciente , Comportamento do Consumidor
8.
Cureus ; 16(2): e54958, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38544616

RESUMO

Ureaplasma species, typically considered commensal organisms of the human urogenital tract, have been implicated in various urinary tract infections (UTIs), including the rare and challenging presentation of pyelonephritis. This case report describes a unique instance of pyelonephritis induced by Ureaplasma, characterized by a negative routine urine culture and a lack of response to empirical antibiotic treatment, highlighting the complexities associated with diagnosing and managing infections caused by atypical pathogens. A 50-year-old female presented to the emergency department with symptoms suggestive of UTI, including fever, vomiting, and dysuria. However, initial urine analysis was notable for pyuria while routine bacterial culture returned negative results, creating a diagnostic dilemma. Empirical treatment with third-generation cephalosporin was initiated. However, the patient's condition failed to improve, raising concerns about antibiotic resistance or atypical pathogens. Subsequent molecular diagnostics, precisely polymerase chain reaction (PCR), identified Ureaplasma urealyticum as the causative agent. This prompted a change in the treatment regimen to doxycycline, to which the patient showed significant clinical improvement. Physicians should be aware of Ureaplasma as a potential cause of pyelonephritis, especially in cases of culture-negative UTIs and when patients do not respond to standard empirical treatment. This case emphasizes the importance of considering atypical pathogens in differential diagnosis and the role of molecular diagnostic techniques in guiding appropriate management.

9.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38448797

RESUMO

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Traumatismos Cardíacos/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-38509402

RESUMO

BACKGROUND: Roughly one in six patients receiving conventional transvenous pacemaker systems experience significant complications within 1 year of implant, mainly due to the transvenous lead and subcutaneous pocket. A new helix-fixation single-chamber ventricular leadless pacemaker (LP) system capable of pre-deployment exploratory electrical mapping is commercially available. Such an LP may mitigate complications while streamlining the implantation. In this study, the initial real-world implant experience of the helix-fixation LP was evaluated following its commercial release. METHODS: In patients indicated for single-chamber right ventricular pacing, helix-fixation Aveir VR LPs (Abbott, Abbott Park, IL) were implanted using the dedicated loading tool, introducer, and delivery catheter. Implant procedural characteristics, electrical parameters, and any 30-day procedure-related adverse events of consecutive implant attempts were retrospectively evaluated. RESULTS: A total of 167 patients with Class I indication for permanent pacing received implants in four North American centers (57% male, 70 years old). Pre-fixation electrical mapping of potential sites allowed repositioning to be avoided in 95.7% of patients. Median [interquartile range] LP procedure and fluoroscopy durations were 25.5 min [20.0, 35.0] and 5.7 min [4.0, 9.2], respectively. Pacing capture threshold, sensed R-wave amplitude, and impedance were 0.8 V [0.5, 1.3], 9.0 mV [6.0, 12.0], and 705 Ω [550, 910], respectively. Implantation was successful in 98.8% of patients, with 98.2% free from acute adverse events. CONCLUSIONS: The initial, real-world experience of the helix-fixation ventricular leadless pacemaker demonstrated safe and efficient implantation with minimal repositioning, viable electrical metrics, and limited acute complications.

11.
JACC Clin Electrophysiol ; 10(1): 68-78, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897465

RESUMO

BACKGROUND: Injury to the esophagus has been reported in a high percentage of patients undergoing ablation of atrial fibrillation (AF). OBJECTIVES: This study assessed the incidence of esophageal injury in patients undergoing ablation of AF with and without an esophageal deviating device. METHODS: This prospective, randomized, multicenter, double-blinded, controlled Food and Drug Administration investigational device exemption trial compared the incidence of ablation-related esophageal lesions, as assessed by endoscopy, in patients undergoing AF ablation assigned to a control group (luminal esophageal temperature [LET] monitoring alone) compared with patients randomized to a deviation group (esophagus deviation device + LET). This novel deviating device uses vacuum suction and mechanical deflection to deviate a segment of the esophagus, including the trailing edge. RESULTS: The data safety and monitoring board recommended stopping the study early after randomizing 120 patients due to deviating device efficacy. The primary study endpoint, ablation injury to the esophageal mucosa, was significantly less in the deviation group (5.7%) in comparison to the control group (35.4%; P < 0.0001). Control patients had a significantly higher severity and greater number of ablation lesions per patient. There was no adverse event assigned to the device. By multivariable analysis, the only feature associated with reduced esophageal lesions was randomization to deviating device (OR: 0.13; 95% CI: 0.04-0.46; P = 0.001). Among control subjects, there was no difference in esophageal lesions with high power/short duration (31.8%) vs other radiofrequency techniques (37.2%; P = 0.79). CONCLUSIONS: The use of an esophageal deviating device resulted in a significant reduction in ablation-related esophageal lesions without any adverse events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Humanos , Estudos Prospectivos , Ablação por Cateter/métodos , Esôfago/cirurgia
12.
JACC Clin Electrophysiol ; 10(2): 270-283, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37999669

RESUMO

BACKGROUND: Strokes after left atrial appendage closure (LAAC) prophylaxis are generally less severe than those after warfarin prophylaxis-thought to be secondary to more hemorrhagic strokes with warfarin. Hemorrhagic strokes are similarly infrequent with direct oral anticoagulant (DOAC) prophylaxis, so the primary subtype after either LAAC or DOAC prophylaxis is ischemic stroke (IS). OBJECTIVES: The purpose of this study was to compare the severity of IS using the modified Rankin Scale in atrial fibrillation patients receiving prophylaxis with DOACs vs LAAC. METHODS: A retrospective analysis was performed of consecutive patients undergoing LAAC at 8 centers who developed an IS (ISLAAC) compared with contemporaneous consecutive patients who developed IS during treatment with DOACs (ISDOAC). The primary outcome was disabling/fatal stroke (modified Rankin Scale 3-5) at discharge and 3 months later. RESULTS: Compared with ISDOAC patients (n = 322), ISLAAC patients (n = 125) were older (age 77.2 ± 13.4 years vs 73.1 ± 11.9 years; P = 0.002), with higher HAS-BLED scores (3.0 vs 2.0; P = 0.004) and more frequent prior bleeding events (54.4% vs 23.6%; P < 0.001), but similar CHA2DS2-VASc scores (5.0 vs 5.0; P = 0.28). Strokes were less frequently disabling/fatal with ISLAAC than ISDOAC at both hospital discharge (38.3% vs 70.3%; P < 0.001) and 3 months later (33.3% vs 56.2%; P < 0.001). Differences in stroke severity persisted after propensity score matching. By multivariate regression analysis, ISLAAC was independently associated with fewer disabling/fatal strokes at discharge (OR: 0.22; 95% CI: 0.13-0.39; P < 0.001) and 3 months (OR: 0.25; 95% CI: 0.12-0.50; P < 0.001), and fewer deaths at 3 months (OR: 0.28; 95% CI: 0.12-0.64; P < 0.001). CONCLUSIONS: Ischemic strokes in patients with atrial fibrillation are less often disabling or fatal with LAAC than DOAC prophylaxis.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral Hemorrágico , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Varfarina/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , AVC Isquêmico/induzido quimicamente , AVC Isquêmico/complicações , AVC Isquêmico/tratamento farmacológico , Acidente Vascular Cerebral Hemorrágico/induzido quimicamente , Acidente Vascular Cerebral Hemorrágico/complicações , Acidente Vascular Cerebral Hemorrágico/tratamento farmacológico , Estudos Retrospectivos , Oclusão do Apêndice Atrial Esquerdo , Resultado do Tratamento , Anticoagulantes/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente
13.
JACC Cardiovasc Interv ; 16(22): 2708-2718, 2023 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-37943200

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) is an approved alternative for stroke prevention in atrial fibrillation for patients with an "appropriate rationale" to avoid long-term oral anticoagulation (OAC). Many patients undergoing LAAO are at high risk of bleeding. OBJECTIVES: This study sought to investigate whether dual antiplatelet therapy (DAPT) is a safe alternative to OAC (direct oral anticoagulation [DOAC] or warfarin) with aspirin after LAAO. METHODS: Using National Cardiovascular Data Registry LAAO registry data, patients undergoing Watchman FLX (Boston Scientific) implantation (August 5, 2020-September 30, 2021) were included in 1:1 propensity-matched analyses comparing discharge medication regimens (DAPT, DOAC/aspirin, or warfarin/aspirin). A composite endpoint (death, stroke, major bleeding, and systemic embolism), its components, and device-related thrombus between discharge and 45 days were evaluated. RESULTS: In 49,968 patients implanted with the Watchman FLX during the study period, the mean age was 77 years, and 40% were women. Postimplant DOAC/aspirin was prescribed in 24,497 patients, warfarin/aspirin in 3,913, and DAPT in 4,155. DAPT patients had more comorbid conditions than patients receiving OAC/aspirin. After propensity score matching, the 45-day composite endpoint rates were similar among the groups (DAPT = 3.44% vs DOAC/aspirin: 4.06%; P = 0.13 and DAPT = 3.23% vs warfarin/aspirin: 3.08%; P = 0.75). Death, stroke, and device-related thrombus were also similar; major bleeding was slightly increased in DOAC/aspirin patients (DAPT = 2.48% vs DOAC/aspirin = 3.25%; P = 0.04 and DAPT = 2.25% vs warfarin/aspirin = 2.22%; P = 0.93). CONCLUSIONS: In a large registry, DAPT had a similar safety profile compared with current Food and Drug Administration-approved postimplant drug regimens of OAC with aspirin following LAAO with the Watchman FLX. Shared decision making for nonpharmacologic stroke prevention should include a discussion of postprocedure medical therapy options.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Trombose , Humanos , Feminino , Idoso , Masculino , Varfarina/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Anticoagulantes/efeitos adversos , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Hemorragia/induzido quimicamente , Aspirina/efeitos adversos , Trombose/tratamento farmacológico , Sistema de Registros
14.
JACC Clin Electrophysiol ; 9(12): 2587-2599, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37831030

RESUMO

BACKGROUND: Intraprocedural imaging is critical for device delivery in transcatheter left atrial appendage occlusion (LAAO). Although pivotal trials of LAAO devices were conducted using transesophageal echocardiography (TEE), intracardiac echocardiography (ICE) is an emerging imaging modality. OBJECTIVES: This study compared outcomes after ICE- and TEE-guided Watchman FLX implantation in the SURPASS (SURveillance Post Approval AnalySiS Plan) nationwide LAAO registry. METHODS: Baseline characteristics were compared using chi-square and t-tests. Outcomes were reported in unadjusted and adjusted comparisons via propensity weighting. RESULTS: Between August 2020 and September 2021, LAAO was attempted in 39,759 patients at 698 sites, including 2,272 cases (5.7%) with ICE and 31,835 (80.0%) with TEE. ICE and TEE patients had similar baseline characteristics and mean procedural times (ICE 82 minutes vs TEE 78 minutes). ICE patients were less likely to receive general anesthesia (54% vs 98%, P < 0.01). Successful device implantation (98.3% vs 97.6%) and complete seal rates at 45 days were similar (n = 25,280; 83% vs 82%). Most adverse event rates were similar; unadjusted mortality rates at 45 days were 1.1% for ICE vs 0.8% for TEE (P = 0.14), and 1.0% vs 0.7% (P = 0.27) in adjusted analyses. Even after adjustment, pericardial effusion rates requiring intervention were significantly higher with ICE at 45 days (1.0% vs 0.5%; P = 0.02). This rate decreased as operators performed more ICE-guided procedures, although 82% of operators had performed <10 ICE-guided procedures overall. CONCLUSIONS: In the largest comparison to date, ICE use was infrequent. ICE and TEE both achieved high rates of complete LAAO. ICE was associated with significantly higher rates of pericardial effusion requiring intervention.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Derrame Pericárdico , Humanos , Ecocardiografia Transesofagiana , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Derrame Pericárdico/etiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos
15.
Circ Arrhythm Electrophysiol ; 16(10): e012232, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37767710

RESUMO

BACKGROUND: The clinical utilization of leadless pacemakers (LPs) as an alternative to traditional transvenous pacemakers is likely to increase with the advent of dual-chamber LP systems. Since device retrieval to allow LP upgrade or replacement will become an important capability, the first such dual-chamber, helix-fixation LP system (Aveir DR; Abbott, Abbott Park, IL) was specifically designed to allow catheter-based retrieval. In this study, the preclinical performance and safety of retrieving chronically implanted dual-chamber LPs was evaluated. METHODS: Atrial and ventricular LPs were implanted in the right atrial appendage and right ventricular apex of 9 healthy ovine subjects. After ≈2 years, the LPs were retrieved using a dedicated transvenous retrieval catheter (Aveir Retrieval Catheter; Abbott) by snaring, docking, and unscrewing from the myocardium. Comprehensive necropsy/histopathology studies were conducted to evaluate device- and procedure-related outcomes. RESULTS: At a median of 1.9 years postimplant (range, 1.8-2.6), all 18 of 18 (100%) LPs were retrieved from 9 ovine subjects without complications. The median retrieval procedure duration for both LPs, from first-catheter-in to last-catheter-out, was 13.3 minutes (range, 2.5-36.4). Postretrieval, all right atrial, and right ventricular implant sites demonstrated minimal tissue disruption, with intact fibrous tissue limited to the distal device body. No significant device-related trauma, perforation, pericardial effusion, right heart or tricuspid valve injury, or chronic pulmonary thromboembolism were observed at necropsy. CONCLUSIONS: This preclinical study demonstrated the safe and effective retrieval of chronically implanted, helix-fixation, dual-chamber LP systems, paving the way for clinical studies of LP retrieval.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Ovinos , Animais , Lipopolissacarídeos , Carneiro Doméstico , Ventrículos do Coração , Desenho de Equipamento
16.
JACC Cardiovasc Interv ; 16(15): 1902-1913, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37587599

RESUMO

BACKGROUND: The Amulet (Abbott) left atrial appendage occluder investigational device exemption trial is the largest randomized trial evaluating the safety and effectiveness of the Amulet left atrial appendage occluder compared with the Watchman 2.5 device (Boston Scientific) through 5 years. OBJECTIVES: This analysis evaluated the device effect on 3-year outcomes in the Amulet investigational device exemption trial. METHODS: The medication regimen and key clinical outcomes were reported through 3 years including: 1) the composite of ischemic stroke or systemic embolism (SE); 2) the composite of all strokes, SE, or cardiovascular (CV) death; 3) major bleeding; and 4) all-cause death and CV death. RESULTS: A total of 1,878 patients at 108 sites were randomized. A significantly higher percentage of patients were free of oral anticoagulation usage at 3 years with Amulet (96.2%) vs Watchman (92.5%) (P < 0.01). Clinical outcomes were comparable for the composite of ischemic stroke or SE (5.0% vs 4.6%; P = 0.69); the composite of all strokes, SE, or CV death (11.1% vs 12.7%; P = 0.31); major bleeding (16.1% vs 14.7%; P = 0.46); all-cause death (14.6% vs 17.9%; P = 0.08); and CV death (6.6% vs 8.5%; P = 0.14) for Amulet and Watchman, respectively. Through 3 years, device factors (device-related thrombus or peridevice leak ≥3 mm) preceded ischemic stroke events and CV deaths more frequently in Watchman compared with Amulet patients. CONCLUSIONS: The Amulet occluder demonstrated continued safety and effectiveness with over 96% free of oral anticoagulation usage through 3 years in a high-risk population compared to the Watchman device. (AMPLATZER Amulet LAA Occluder Trial [Amulet IDE]; NCT02879448).


Assuntos
Apêndice Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Anticoagulantes
18.
Am Heart J ; 264: 123-132, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37279840

RESUMO

BACKGROUND: Percutaneous left atrial appendage (LAA) closure (LAAC) was developed as a nonpharmacologic alternative to oral anticoagulants (OACs) in patients with atrial fibrillation (AF) who are at an increased risk for stroke or systemic embolism. The Watchman device permanently seals off the LAA to prevent thrombi from escaping into the circulation. Previous randomized trials have established the safety and efficacy of LAAC compared to warfarin. However, direct OACs (DOACs) have become the preferred pharmacologic strategy for stroke prevention in patients with AF, and there is limited data comparing Watchman FLX to DOACs in a broad AF patient population. CHAMPION-AF is designed to prospectively determine whether LAAC with Watchman FLX is a reasonable first-line alternative to DOACs in patients with AF who are indicated for OAC therapy. STUDY DESIGN: A total of 3,000 patients with a CHA2DS2-VASc score ≥2 (men) or ≥3 (women) were randomized to Watchman FLX or DOAC in a 1:1 allocation at 142 global clinical sites. Patients in the device arm were to be treated with DOAC and aspirin, DOAC alone, or DAPT for at least 3 months postimplant followed by aspirin or P2Y12 inhibitor for 1-year. Control patients were required to take an approved DOAC for the duration of the trial. Clinical follow-up visits are scheduled at 3- and 12-months, and then annually through 5 years; LAA imaging is required at 4 months in the device group. Two primary end points will be evaluated at 3 years: (1) composite of stroke (ischemic/hemorrhagic), cardiovascular death, and systemic embolism compared for noninferiority, and (2) nonprocedural bleeding (International Society on Thrombosis and Haemostasis [ISTH] major and clinically relevant nonmajor bleeding) tested for superiority in the device arm against DOACs. The third primary noninferiority end point is the composite of ischemic stroke and systemic embolism at 5 years. Secondary end points include 3- and 5-year rates of (1) ISTH-defined major bleeding and (2) the composite of cardiovascular death, all stroke, systemic embolism, and nonprocedural ISTH bleeding. CONCLUSIONS: This study will prospectively evaluate whether LAAC with the Watchman FLX device is a reasonable alternative to DOACs in patients with AF. CLINICAL TRIAL REGISTRATION: NCT04394546.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Resultado do Tratamento , Seguimentos , Apêndice Atrial/cirurgia , Anticoagulantes/uso terapêutico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Hemorragia/induzido quimicamente , Hemorragia/complicações , Aspirina/uso terapêutico , Embolia/prevenção & controle
19.
Circ Arrhythm Electrophysiol ; 16(6): e011714, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183700

RESUMO

BACKGROUND: The role of atrioventricular optimization (AVO) to improve cardiac resynchronization therapy outcomes remains controversial. Previous post hoc analyses of a multicenter trial showed that measures of electrical dyssynchrony (right ventricular-left ventricular [LV] or LV electrical delay durations) are associated with patients who benefit from AVO. METHODS: This was a global, multicenter, prospective, randomized trial of de novo cardiac resynchronization therapy implant patients with an right ventricular-LV duration ≥70 ms to determine whether AVO results in greater reverse remodeling. Patients were randomized 1:1 for either an AVO algorithm (SmartDelay) that determines atrioventricular delay and pacing chamber, biventricular or LV only, or a fixed atrioventricular delay of 120 ms with biventricular pacing. Paired echocardiograms performed at baseline and 6 months were evaluated. The primary end point was echocardiographic cardiac resynchronization therapy response, defined dichotomously as a >15% reduction in LV end-systolic volume. RESULTS: A total of 310 patients (n=120 women) were randomized and had completed 6 months of follow-up. The echocardiographic cardiac resynchronization therapy response rate did not statistically differ between the groups (SmartDelay, 74.8%; fixed, 67.7%; P=0.17). Analyses of prespecified secondary end points demonstrated significant improvements in the absolute (median: SmartDelay, -41.0 mL; fixed, -33.0 mL; P=0.01) and relative change in LV end-systolic volume (SmartDelay, -38.3%; fixed, -27.8%; P=0.03) for patients with SmartDelay optimization. Similar results were observed for the relative improvement in LV ejection fraction (SmartDelay, 46.7%; fixed, 32.1%; P=0.050); absolute improvement in LV ejection fraction trended to be higher with SmartDelay (P=0.06). CONCLUSIONS: Analysis of reverse remodeling parameters demonstrated that AVO via SmartDelay, relative to the nonoptimized fixed atrioventricular delay comparator group, improved absolute and relative changes in LV function in patients with longer right ventricular-LV duration. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03089281.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Terapia de Ressincronização Cardíaca/métodos , Estudos Prospectivos , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia
20.
Heart Rhythm ; 20(8): 1146-1155, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37075958

RESUMO

BACKGROUND: Dual-chamber leadless pacemakers (LPs) require robust communication between distinct right atrial (RA) and right ventricular (RV) LPs to achieve atrioventricular (AV) synchrony. OBJECTIVE: The purpose of this preclinical study was to evaluate a novel, continuous implant-to-implant (i2i™) communication methodology for maintaining AV-synchronous, dual-chamber DDD(R) pacing by the 2 LPs. METHODS: RA and RV LPs were implanted and paired in 7 ovine subjects (4 with induced complete heart block). AV synchrony (% AV intervals <300 ms) and i2i communication success (% successful i2i transmissions between LPs) were evaluated acutely and chronically. During acute testing, 12-lead electrocardiographic and LP diagnostic data were collected from 5-minute recordings, in 4 postures and 2 rhythms (AP-VP and AS-VP, or AP-VS and AS-VS) per subject. Chronic i2i performance was evaluated through 23 weeks postimplant (final i2i evaluation period: week 16-23). RESULTS: Acute AV synchrony and i2i communication success across multiple postures and rhythms were median [interquartile range] 100.0% [100.0%-100.0%] and 99.9% [99.9%-99.9%], respectively. AV synchrony and i2i success rates did not differ across postures (P = .59, P = .11) or rhythms (P = 1, P = .82). During the final i2i evaluation period, the overall i2i success was 98.9% [98.1%-99.0%]. CONCLUSION: Successful AV-synchronous, dual-chamber DDD(R) leadless pacing using a novel, continuous, wireless communication modality was demonstrated across variations in posture and rhythm in a preclinical model.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Animais , Ovinos , Estimulação Cardíaca Artificial/métodos , Lipopolissacarídeos , Bloqueio Atrioventricular/terapia , Frequência Cardíaca