Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Microbiol Spectr ; 12(4): e0308123, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38446069

RESUMO

Bloodstream infections are associated with high mortality, which can be reduced by targeted antibiotic therapy in the early stages of infection. Direct antibiotic susceptibility testing (AST) from flagged positive blood cultures may facilitate the administration of early effective antimicrobials much before the routine AST. This study aimed to evaluate three different direct AST protocols for Gram-negative rods from flagged positive blood culture broths. Blood culture broths showing Gram-negative rods only were subjected to direct AST by Clinical and Laboratory Standards Institute-recommended direct disk diffusion (protocol A). Additionally, automated AST (protocol B) and Kirby-Bauer disk diffusion (protocol C) were performed with standard inoculum prepared from bacterial pellets obtained by centrifuging blood culture broths in serum separator vials. For comparison, conventional AST of isolates from solid media subculture was also performed with Kirby-Bauer disk diffusion (reference standard) and the automated method. Overall, categorical agreements of protocols A, B, and C were 97.6%, 95.7%, and 95.9%, respectively. Among Enterobacterales, minor error, major error, and very major error rates of protocol B were 3.5%, 0.36%, and 0.43%, respectively, whereas minor error, major error, and very major error rates of protocol C were 3.4%, 0.72%, and 0.21%, respectively, and among non-fermenters, protocol B had a minor error rate of 6.5%, and protocol C had a minor error rate of 4.1% and major error rate of 1.9%. All three direct AST protocols demonstrated excellent categorical agreements with the reference method. Performance of protocols B and C between Enterobacterales and non-fermenters was not statistically different. IMPORTANCE: Bloodstream infections are associated with high mortality that can be reduced by targeted antibiotic therapy in the early stages of infection. Direct antibiotic susceptibility testing (AST) from flagged positive blood cultures may facilitate the administration of early effective antimicrobials much before the routine AST. Clinical and Laboratory Standards Institute-recommended direct AST can be performed with a limited number of antibiotic disks only. On the other hand, using an automated system for direct AST will not only allow effective laboratory workflow with reduced turnaround time but also provide the minimum inhibitory concentration values of tested antibiotics. However, using expensive automated systems for direct AST may not be feasible for resource-limited laboratories. Therefore, in this study, we aimed to evaluate the CLSI-recommended method and two other direct AST protocols (one with an automated system and the other with disk diffusion) for Gram-negative rods from flagged positive blood cultures.


Assuntos
Anti-Infecciosos , Bacteriemia , Sepse , Humanos , Hemocultura/métodos , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Bactérias Gram-Negativas , Testes de Sensibilidade Microbiana , Antibacterianos/farmacologia , Anti-Infecciosos/farmacologia
2.
Trop Doct ; 54(2): 108-111, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38130150

RESUMO

Despite great efforts, intestinal protozoan infections remain a significant healthcare concern worldwide. Although many point-of-care (POC) tests are increasingly being used, microscopic examination of stool specimens remains the mainstay for their diagnosis, especially in resource-limited settings. We assessed the utility of rapid POC tests based on immunochromatography among patients from rural Northern India. A total of 78 patients were enrolled in the study. Out of nine specimens that tested positive for Giardia duodenalis on microscopy, an immunochromatographic test (ICT) could detect only five (55.55%). Entamoeba histolytica/dispar was demonstrated in two specimens on microscopy, both of which were missed by ICT. Its overall sensitivity, specificity, and positive and negative predictive value were 50%, 98.5%, 83.3%, and 93%, respectively. Its performance was considered unsatisfactory. Although ICT-based tests provide a relatively rapid and less labor-intensive alternative, they should be used to supplement and not replace stool microscopy.


Assuntos
Entamoeba histolytica , Entamoeba , Entamebíase , Infecções por Protozoários , Humanos , Pacientes Ambulatoriais , Entamebíase/diagnóstico , Entamebíase/epidemiologia , Fezes , Sensibilidade e Especificidade , Infecções por Protozoários/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA