Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 402(4): 1713-22, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22159512

RESUMO

A certified reference material, NMIJ CRM 7405-a, for the determination of trace elements and As(V) in algae was developed from the edible marine hijiki (Hizikia fusiforme) and certified by the National Metrology Institute of Japan (NMIJ), the National Institute of Advanced Industrial Science and Technology (AIST). Hijiki was collected from the Pacific coast in the Kanto area of Japan, and was washed, dried, powdered, and homogenized. The hijiki powder was placed in 400 bottles (ca. 20 g each). The concentrations of 18 trace elements and As(V) were determined by two to four independent analytical techniques, including (ID)ICP-(HR)MS, ICP-OES, GFAAS, and HPLC-ICP-MS using calibration solutions prepared from the elemental standard solution of Japan calibration service system (JCSS) and the NMIJ CRM As(V) solution, and whose concentrations are certified and SI traceable. The uncertainties of all the measurements and preparation procedures were evaluated. The values of 18 trace elements and As(V) in the CRM were certified with uncertainty (k = 2).


Assuntos
Arsenicais/análise , Phaeophyceae/química , Oligoelementos/análise , Arsenicais/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Padrões de Referência , Oligoelementos/isolamento & purificação
2.
Anal Bioanal Chem ; 401(9): 2909-18, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21928079

RESUMO

The National Metrology Institute of Japan has issued a certified reference material of tunnel dust for polycyclic aromatic hydrocarbons (PAHs) and toxic element analyses. PAH certification was performed using isotope dilution mass spectrometry with deuterium-labeled PAHs as internal standards. Three extraction techniques (microwave-assisted extraction with toluene/methanol, Soxhlet extraction with toluene, and pressurized liquid extraction with toluene) were used, and the extracts were measured by gas chromatography/mass spectrometry with two different columns. For values of PAHs, 11 PAHs are provided as certified values between 0.294 and 20.3 mg/kg, and five PAHs are provided as information values. Certified values of five toxic elements (Cr, Ni, Pb, Mn, and Cd) obtained from microwave-assisted digestions and a combination of measurement techniques are also provided between 43.4 and 10.71 × 10(3) mg/kg.

3.
Anal Bioanal Chem ; 397(2): 493-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20204330

RESUMO

Arsenate [As(V)] solution reference material, National Metrology Institute of Japan (NMIJ) certified reference material (CRM) 7912-a, for speciation of arsenic species was developed and certified by NMIJ, the National Institute of Advanced Industrial Science and Technology. High-purity As(2)O(3) reagent powder was dissolved in 0.8 M HNO(3) solution and As(III) was oxidized to As(V) with HNO(3) to prepare 100 mg kg(-1) of As(V) candidate CRM solution. The solution was bottled in 400 bottles (50 mL each). The concentration of As(V) was determined by four independent analytical techniques-inductively coupled plasma mass spectrometry, inductively coupled plasma optical emission spectrometry, graphite furnace atomic absorption spectrometry, and liquid chromatography inductively coupled plasma mass spectrometry-according to As(V) calibration solutions, which were prepared from the arsenic standard of the Japan Calibration Service system and whose species was guaranteed to be As(V) by NMIJ. The uncertainties of all the measurements and preparation procedures were evaluated. The certified value of As(V) in the CRM is (99.53 +/- 1.67) mg kg(-1) (k = 2).


Assuntos
Arseniatos/normas , Arseniatos/química , Padrões de Referência
4.
Anal Sci ; 24(3): 355-60, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18332542

RESUMO

The sensitivity of graphite furnace atomic absorption spectrometry (GFAAS) to arsenobetaine (AB) was 1.3-times higher than to inorganic As. In order to understand the mechanism underlying this observation, the atomization processes for both chemical species were investigated in terms of the enthalpy change (DeltaH) during the atomization process in GFAAS. The enthalpy change of AB was slightly lower than that of inorganic As, which suggested that AB was atomized more efficiently than was inorganic As. Moreover, it was observed that some co-existing organic materials enhanced the analytical sensitivity of inorganic As. The sensitivity difference between inorganic As and AB depended upon the mechanisms of their atomization processes.


Assuntos
Arsênio/análise , Arsenicais/análise , Grafite/química , Espectrofotometria Atômica/métodos , Arsênio/química , Calibragem , Temperatura Alta , Oxirredução , Sensibilidade e Especificidade , Espectrofotometria Atômica/instrumentação , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA