Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 948
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38703164

RESUMO

BACKGROUND: In patients with persistent atrial fibrillation (PerAF), antiarrhythmic drugs (AADs) are considered a first-line rhythm-control strategy, whereas catheter ablation is a reasonable alternative. OBJECTIVES: This study sought to examine the prevalence, patient characteristics, and clinical outcomes of patients with PerAF who underwent catheter ablation as a first or second-line strategy. METHODS: This multicenter observational study included consecutive patients with PerAF who underwent first-time ablation between January 2020 and September 2021 in 9 medical centers in the United States. Patients were divided into those who underwent ablation as first-line therapy and those who had ablation as second-line therapy. Patient characteristics and clinical outcomes were compared between the groups. RESULTS: A total of 2,083 patients underwent first-time ablation for PerAF. Of these, 1,086 (52%) underwent ablation as a first-line rhythm-control treatment. Compared with patients treated with AADs as first-line therapy, these patients were predominantly male (72.6% vs 68.1%; P = 0.03), with a lower frequency of hypertension (64.0% vs 73.4%; P < 0.001) and heart failure (19.1% vs 30.5%; P < 0.001). During a mean follow-up of 325.9 ± 81.6 days, arrhythmia-free survival was similar between the groups (HR: 1.13; 95% CI: 0.92-1.41); however, patients in the second-line ablation strategy were more likely to continue receiving AAD therapy (41.5% vs 15.9%; P < 0.001). CONCLUSIONS: A first-line ablation strategy for PerAF is prevalent in the United States, particularly in men with fewer comorbidities. More data are needed to identify patients with PerAF who derive benefit from an early intervention strategy.

3.
Nat Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760584

RESUMO

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .

5.
Card Electrophysiol Clin ; 16(2): 181-186, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749639

RESUMO

A 70-year-old man with recurrent atrial fibrillation (AF) underwent transcatheter radiofrequency ablation after an earlier unsuccessful attempt. Although typical AF triggers were ablated, the patient's condition persisted, leading to the identification of the interatrial septum (IAS) as the probable source of the tachycardia trigger. Given the depth and thickness of the IAS, traditional radiofrequency ablation proved ineffective. However, using the alternative method of bipolar radiofrequency catheter ablation (B-RFCA), the atrial tachycardia was successfully terminated. B-RFCA demonstrates potential for effectively terminating tachycardias originating from deep intramural locations, suggesting its potential as a pivotal technique for complex cases with septal atrial tachycardia.


Assuntos
Ablação por Cateter , Humanos , Masculino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Septo Interatrial/cirurgia , Septo Interatrial/diagnóstico por imagem
6.
Artigo em Inglês | MEDLINE | ID: mdl-38751010

RESUMO

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.

9.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584468

RESUMO

AIMS: Pulsed field ablation (PFA) has significant advantages over conventional thermal ablation of atrial fibrillation (AF). This first-in-human, single-arm trial to treat paroxysmal AF (PAF) assessed the efficiency, safety, pulmonary vein isolation (PVI) durability and one-year clinical effectiveness of an 8 Fr, large-lattice, conformable single-shot PFA catheter together with a dedicated electroanatomical mapping system. METHODS AND RESULTS: After rendering the PV anatomy, the PFA catheter delivered monopolar, biphasic pulse trains (5-6 s per application; ∼4 applications per PV). Three waveforms were tested: PULSE1, PULSE2, and PULSE3. Follow-up included ECGs, Holters at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy endpoints were acute PVI and post-blanking atrial arrhythmia recurrence, respectively. Invasive remapping was conducted ∼75 days post-ablation. At three centres, PVI was performed by five operators in 85 patients using PULSE1 (n = 30), PULSE2 (n = 20), and PULSE3 (n = 35). Acute PVI was achieved in 100% of PVs using 3.9 ± 1.4 PFA applications per PV. Overall procedure, transpired ablation, PFA catheter dwell and fluoroscopy times were 56.5 ± 21.6, 10.0 ± 6.0, 19.1 ± 9.3, and 5.7 ± 3.9 min, respectively. No pre-defined primary safety events occurred. Upon remapping, PVI durability was 90% and 99% on a per-vein basis for the total and PULSE3 cohort, respectively. The Kaplan-Meier estimate of one-year freedom from atrial arrhythmias was 81.8% (95% CI 70.2-89.2%) for the total, and 100% (95% CI 80.6-100%) for the PULSE3 cohort. CONCLUSION: Pulmonary vein isolation (PVI) utilizing a conformable single-shot PFA catheter to treat PAF was efficient, safe, and effective, with durable lesions demonstrated upon remapping.


Assuntos
Fibrilação Atrial , Cateteres Cardíacos , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Desenho de Equipamento , Técnicas Eletrofisiológicas Cardíacas , Fatores de Tempo , Frequência Cardíaca , Potenciais de Ação
11.
J Clin Med ; 13(5)2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38592178

RESUMO

Although mitral valve prolapse (MVP) is the most prevalent valvular abnormality in Western countries and generally carries a good prognosis, a small subset of patients is exposed to a significant risk of malignant ventricular arrhythmias (VAs) and sudden cardiac death (SCD), the so-called arrhythmic MVP (AMVP) syndrome. Recent work has emphasized phenotypical risk features of severe AMVP and clarified its pathophysiology. However, the appropriate assessment and risk stratification of patients with suspected AMVP remains a clinical conundrum, with the possibility of both overestimating and underestimating the risk of malignant VAs, with the inappropriate use of advanced imaging and invasive electrophysiology study on one hand, and the catastrophic occurrence of SCD on the other. Furthermore, the sports eligibility assessment of athletes with AMVP remains ill defined, especially in the grey zone of intermediate arrhythmic risk. The definition, epidemiology, pathophysiology, risk stratification, and treatment of AMVP are covered in the present review. Considering recent guidelines and expert consensus statements, we propose a comprehensive pathway to facilitate appropriate counseling concerning the practice of competitive/leisure-time sports, envisioning shared decision making and the multidisciplinary "sports heart team" evaluation of borderline cases. Our final aim is to encourage an active lifestyle without compromising patients' safety.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

13.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-38448258

RESUMO

BACKGROUND: Left atrial appendage (LAA) occluder embolization is an infrequent but serious complication. OBJECTIVES: We aim to describe timing, management and clinical outcomes of device embolization in a multi-center registry. METHODS: Patient characteristics, imaging findings and procedure and follow-up data were collected retrospectively. Device embolizations were categorized according to 1) timing 2) management and 3) clinical outcomes. RESULTS: Sixty-seven centers contributed data. Device embolization occurred in 108 patients. In 70.4 % of cases, it happened within the first 24 h of the procedure. The device was purposefully left in the LA and the aorta in two (1.9 %) patients, an initial percutaneous retrieval was attempted in 81 (75.0 %) and surgery without prior percutaneous retrieval attempt was performed in 23 (21.3 %) patients. Two patients died before a retrieval attempt could be made. In 28/81 (34.6 %) patients with an initial percutaneous retrieval attempt a second, additional attempt was performed, which was associated with a high mortality (death in patients with one attempt: 2.9 % vs. second attempt: 21.4 %, p < 0.001). The primary outcome (bailout surgery, cardiogenic shock, stroke, TIA, and/or death) occurred in 47 (43.5 %) patients. Other major complications related to device embolization occurred in 21 (19.4 %) patients. CONCLUSIONS: The majority of device embolizations after LAA closure occurs early. A percutaneous approach is often the preferred method for a first rescue attempt. Major adverse event rates, including death, are high particularly if the first retrieval attempt was unsuccessful. CONDENSED ABSTRACT: This dedicated multicenter registry examined timing, management, and clinical outcome of device embolization. Early embolization (70.4 %) was most frequent. As a first rescue attempt, percutaneous retrieval was preferred in 75.0 %, followed by surgical removal (21.3 %). In patients with a second retrieval attempt a higher mortality (death first attempt: 2.9 % vs. death second attempt: 24.1 %, p < 0.001) was observed. Mortality (10.2 %) and the major complication rate after device embolization were high.

17.
JACC Case Rep ; 29(5): 102227, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38464799

RESUMO

We present a case of persistent complete atrioventricular block that occurred during the diagnostic portion of a premature ventricular contractions' radiofrequency ablation in a complex heart failure patient. The case was managed by bailout deep left ventricular septal pacing after bipolar radiofrequency elimination of premature ventricular contractions.

18.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38390748

RESUMO

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Assuntos
Ablação por Cateter , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ventrículos do Coração/cirurgia , Catéteres , Desenho de Equipamento
19.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310489

RESUMO

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Hemoglobinúria , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Hemoglobinúria/etiologia , Hemoglobinúria/prevenção & controle , Creatinina/sangue , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/métodos
20.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38305503

RESUMO

AIMS: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation. METHODS AND RESULTS: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location. CONCLUSION: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Veias Pulmonares/cirurgia , Constrição Patológica/complicações , Constrição Patológica/cirurgia , Método Simples-Cego , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA