RESUMO
The study of metabolomics is revealing immense potential for diagnosis, therapy monitoring, and understanding of pathogenesis processes. Volatilomics is a subcategory of metabolomics interested in the detection of molecules that are small enough to be released in the gas phase. Volatile compounds produced by cellular processes are released into the blood and lymph, and can reach the external environment through different pathways, such as the blood-air interface in the lung that are detected in breath, or the blood-water interface in the kidney that leads to volatile compounds detected in urine. Besides breath and urine, additional sources of volatile compounds such as saliva, blood, feces, and skin are available. Volatilomics traces its roots back over fifty years to the pioneering investigations in the 1970s. Despite extensive research, the field remains in its infancy, hindered by a lack of standardization despite ample experimental evidence. The proliferation of analytical instrumentations, sample preparations and methods of volatilome sampling still make it difficult to compare results from different studies and to establish a common standard approach to volatilomics. This review aims to provide an overview of volatilomics' diagnostic potential, focusing on two key technical aspects: sampling and analysis. Sampling poses a challenge due to the susceptibility of human samples to contamination and confounding factors from various sources like the environment and lifestyle. The discussion then delves into targeted and untargeted approaches in volatilomics. Some case studies are presented to exemplify the results obtained so far. Finally, the review concludes with a discussion on the necessary steps to fully integrate volatilomics into clinical practice.
RESUMO
The ability of olfaction to distinguish odors is based on many different properties deriving from the molecular structure, including chirality. Even if the electronic nose (e-nose) concept has been widely used in strict analogy with biological systems to implement sensor arrays that recognize and distinguish complex odor matrices, the fabrication of an enantioselective e-nose remains a challenge. This paper introduces an array of quartz microbalances (QMB) functionalized with sensitive materials made of a combination of achiral receptors and silica nanohelices grafted by chiral and achiral porphyrins. In this combination, nanohelices provide a chiral template for the spatial arrangement of porphyrins, while porphyrins act as receptors that can interact differently with analytes. Remarkably, even if single sensors show scarce enantioselectivity, the signals of the overall array achieve recognition of the chiral identity of the five diverse enantiomeric pairs tested when the data are processed with proper multivariate algorithms. Such an innovative and generalizable approach is expected to enable the formation of an extensive library of readily integrable chiral receptors in enantioselective sensor arrays, potentially revolutionizing diverse fields such as agrochemicals, medicine, and environmental sciences.
RESUMO
Direct catalytic methanol fuel cells (DCMFCs) have been studied for several years for energy conversion. Less extensive is the investigation of their analytical properties. In this paper, we demonstrate that the behavior of both the discharge and charger curves of DCMFCs depends on the chemical composition of the solution injected in the fuel cell. Their discharge and charge curves, analyzed using a chemometric data fusion method named ComDim, enable the identification of various types of aliphatic alcohols diluted in water. The results also show that the identification of alcohols can be obtained from the first portion of the discharge and charge curves. To this end, the curves have been described by a set of features related to the slope and intercept of the initial portion of the curves. The ComDim analysis of this set of features shows that the identification of alcohols can be obtained in a time that is about thirty times shorter than the time taken to achieve steady-state voltage.
RESUMO
An original approach has been proposed for designing a nanofibrous (NF) layer using UV-cured polyvinylpyrrolidone (PVP) as a matrix, incorporating mesoporous graphene carbon (MGC) nanopowder both inside and outside the fibers, creating a sandwich-like structure. This architecture is intended to selectively adsorb and detect acetic acid vapors, which are known to cause health issues in exposed workers. The nanocomposite MGC-PVP-NFs layer was fabricated through electrospinning deposition onto interdigitated microelectrodes (IDEs) and stabilized under UV-light irradiation. To enhance the adhesion of MGC onto the surface of the nanocomposite polymeric fibers, the layer was dipped in a suspension of polyethyleneimine (PEI) and MGC. The resulting structure demonstrated promising electrical and sensing properties, including rapid responses, high sensitivity, good linearity, reversibility, repeatability, and selectivity towards acetic acid vapors. Initial testing was conducted in a laboratory using a bench electrometer, followed by validation in a portable sensing device based on consumer electronic components (by ARDUINO®). This portable system was designed to provide a compact, cost-effective solution with high sensing capabilities. Under room temperature and ambient air conditions, both laboratory and portable tests exhibited favorable linear responses, with detection limits of 0.16 and 1 ppm, respectively.
RESUMO
Laser-induced graphene (LIG) has emerged as a highly versatile material with significant potential in the development of electrochemical sensors. In this paper, we investigate the use of LIG and LIG functionalized with ZnO and porphyrins-ZnO as the gate electrodes of the extended gate field effect transistors (EGFETs). The resultant sensors exhibit remarkable sensitivity and selectivity, particularly toward ascorbic acid. The intrinsic sensitivity of LIG undergoes a notable enhancement through the incorporation of hybrid organic-inorganic materials. Among the variations tested, the LIG electrode coated with zinc tetraphenylporphyrin-capped ZnO nanoparticles demonstrates superior performance, reaching a limit of detection of approximately 3 nM. Furthermore, the signal ratio for 5 µM ascorbic acid relative to the same concentration of dopamine exceeds 250. The practical applicability of these sensors is demonstrated through the detection of ascorbic acid in real-world samples, specifically in a commercially available food supplement containing l-arginine. Notably, formulations with added vitamin C exhibit signals at least 25 times larger than those without, underscoring the sensors' capability to discern and quantify the presence of ascorbic acid in complex matrices. This research not only highlights the enhanced performance of LIG-based sensors through functionalization but also underscores their potential for practical applications in the analysis of vitamin-rich supplements.
RESUMO
Volatile organic compounds (VOCs) comprise a diverse range of metabolites with high vapour pressure and low boiling points. Although they have received attention, they are a largely unexplored part of the metabolome. Previous studies have shown that malaria infections produce characteristic, definitive, and detectable volatile signatures. Many transcriptional and metabolic differences are observed at different stages of the parasite Intraerythrocytic Developmental Cycle (IDC) as well as when artemisinin-resistant parasites are put under drug pressure. This prompted our research to characterize whether these responses are reflected at a volatile level in malaria during the IDC stages using gas chromatography-mass spectrometry. We investigated whether the resistant P. falciparum parasites would produce their own characteristic volatilome profile compared to near-isogenic wild-type parasite in vitro; firstly at three different stages of the IDC and secondly in the presence or absence of artemisinin drug treatment. Finally, we explored the VOC profiles from two media environments (Human serum and Albumax) of recently lab-adapted field parasite isolates, from Southeast Asia and West/East Africa, compared to long-term lab-adapted parasites. Recognizable differences were observed between IDC stages, with schizonts having the largest difference between wild type and resistant parasites, and with cyclohexanol and 2,5,5-trimethylheptane only present for resistant schizonts. Artemisinin treatment had little effect on the resistant parasite VOC profile, whilst for the wild type parasites compounds ethylbenzene and nonanal were greatly affected. Lastly, differing culturing conditions had an observable impact on parasite VOC profile and clustering patterns of parasites were specific to geographic origin. The results presented here provide the foundation for future studies on VOC based characterization of P. falciparum strains differing in abilities to tolerate artemisinin.
Assuntos
Antimaláricos , Artemisininas , Malária Falciparum , Malária , Parasitos , Compostos Orgânicos Voláteis , Humanos , Animais , Plasmodium falciparum , Antimaláricos/farmacologia , Antimaláricos/uso terapêutico , Compostos Orgânicos Voláteis/farmacologia , Resistência a Medicamentos , Artemisininas/farmacologia , Artemisininas/uso terapêutico , Malária Falciparum/tratamento farmacológico , Malária Falciparum/parasitologia , Malária/tratamento farmacológico , Proteínas de Protozoários/farmacologiaRESUMO
BACKGROUND: The growing demand for rosé sparkling wine has led to an increase in its production. Traditional or Charmat wine-making influence the aromatic profiles in wine. An analysis such as gas chromatography makes an accurate assessment of wines based on volatile detection but is resource intensive. On the other hand, the electronic nose (E-nose) has emerged as a versatile tool, offering rapid, cost-effective discrimination of wines, and contributing insights into quality and production processes because of its aptitude to perform a global aromatic pattern evaluation. In the present study, rosé sparkling wines were produced using both methods and major volatile compounds and polyols were measured. Wines were tested by E-nose and predictive modelling was performed to distinguish them. RESULTS: Volatile profiles showed differences between Charmat and traditional methods, especially at 5 months of aging. A partial least square discriminant analysis (PLS-DA) was carried out on E-nose detections, obtaining a model that describes 94% of the variability, separating samples in different clusters and correctly identifying different classes. The differences derived from PLS-DA clustering agree with the results obtained by gas-chromatography. Moreover, a principal components regression model was built to verify the ability of the E-nose to non-destructively predict the amount of different volatiles analyzed. CONCLUSION: Production methods of Rosé sparkling wine affect the final wine aroma profiles as a result of the differences in terms of volatiles. The PLS-DA of the data obtained with E-nose reveals that distinguishing between Charmat and traditional methods is possible. Moreover, predictive models using gas chromatography-flame ionization detection analysis and E-nose highlight the possibility of fast and efficient prediction of volatiles from the E-nose. © 2023 The Authors. Journal of The Science of Food and Agriculture published by John Wiley & Sons Ltd on behalf of Society of Chemical Industry.
RESUMO
The versatility of metal complexes of corroles has raised interest in the use of these molecules as elements of chemical sensors. The tuning of the macrocycle properties via synthetic modification of the different components of the corrole ring, such as functional groups, the molecular skeleton, and coordinated metal, allows for the creation of a vast library of corrole-based sensors. However, the scarce conductivity of most of the aggregates of corroles limits the development of simple conductometric sensors and requires the use of optical or mass transducers that are rather more cumbersome and less prone to be integrated into microelectronics systems. To compensate for the scarce conductivity, corroles are often used to functionalize the surface of conductive materials such as graphene oxide, carbon nanotubes, or conductive polymers. Alternatively, they can be incorporated into heterojunction devices where they are interfaced with a conductive material such as a phthalocyanine. Herewith, we introduce two heterostructure sensors combining lutetium bisphthalocyanine (LuPc2) with either 5,10,15-tris(pentafluorophenyl) corrolato Cu (1) or 5,10,15-tris(4-methoxyphenyl)corrolato Cu (2). The optical spectra show that after deposition, corroles maintain their original structure. The conductivity of the devices reveals an energy barrier for interfacial charge transport for 1/LuPc2, which is a heterojunction device. On the contrary, only ohmic contacts are observed in the 2/LuPc2 device. These different electrical properties, which result from the different electron-withdrawing or -donating substituents on corrole rings, are also manifested by the opposite response with respect to ammonia (NH3), with 1/LuPc2 behaving as an n-type conductor and 2/LuPC2 behaving as a p-type conductor. Both devices are capable of detecting NH3 down to 10 ppm at room temperature. Furthermore, the sensors show high sensitivity with respect to relative humidity (RH) but with a reversible and fast response in the range of 30-60% RH.
RESUMO
We report here a small library of a new type of acyclic squaramide receptors (L1-L5) as selective ionophores for the detection of ketoprofen and naproxen anions (KF- and NS-, respectively) in aqueous media. 1H NMR binding studies show a high affinity of these squaramide receptors toward KF- and NS-, suggesting the formation of H-bonds between the two guests and the receptors through indole and -NH groups. Compounds L1-L5 have been tested as ionophores for the detection of KF- and NS- inside solvent PVC-based polymeric membranes. The optimal membrane compositions were established through the careful variation of the ligand/tridodecylmethylammonium chloride (TDMACl) anion-exchanger ratio. All of the tested acyclic squaramide receptors L1-L5 have high affinity toward KF- and NS- and anti-Hofmeister selectivity, with L4 and L5 showing the highest sensitivity and selectivity to NS-. The utility of the developed sensors for a high precision detection of KF- in pharmaceutical compositions with low relative errors of analysis (RSD, 0.99-1.4%) and recoveries, R%, in the range 95.1-111.8% has been demonstrated. Additionally, the chemometric approach has been involved to effectively discriminate between the structurally very similar KF- and NS-, and the possibility of detecting these analytes at concentrations as low as 0.07 µM with R2 of 0.947 and at 0.15 µM with R2 of 0.919 for NS- and KF-, respectively, was shown.
Assuntos
Quinina , Ionóforos/química , Ânions/análiseRESUMO
Enantiorecognition of a chiral analyte usually requires the ability to respond with high specificity to one of the two enantiomers of a chiral compound. However, in most cases, chiral sensors have chemical sensitivity toward both enantiomers, showing differences only in the intensity of responses. Furthermore, specific chiral receptors are obtained with high synthetic efforts and have limited structural versatility. These facts hinder the implementation of chiral sensors in many potential applications. Here, we utilize the presence of both enantiomers of each receptor to introduce a novel normalization that allows the enantio-recognition of compounds even when single sensors are not specific for one enantiomer of a target analyte. For this purpose, a novel protocol that permits the fabrication of a large set of enantiomeric receptor pairs with low synthetic efforts by combining metalloporphyrins with (R,R)- and (S,S)-cyclohexanohemicucurbit[8]uril is developed. The potentialities of this approach are investigated by an array of four pairs of enantiomeric sensors fabricated using quartz microbalances since gravimetric sensors are intrinsically non-selective toward the mechanism of interaction of analytes and receptors. Albeit the weak enantioselectivity of single sensors toward limonene and 1-phenylethylamine, the normalization allows the correct identification of these enantiomers in the vapor phase indifferent to their concentration. Remarkably, the achiral metalloporphyrin choice influences the enantioselective properties, opening the way to easily obtain a large library of chiral receptors that can be implemented in actual sensor arrays. These enantioselective electronic noses and tongues may have a potential striking impact in many medical, agrochemical, and environmental fields.
RESUMO
In this work, it has been experimentally proven that the kinetic performance of a common Direct Catalytic Ethanol Fuel Cell (DCEFC) can be increased by introducing nanostructured (ZnII,AlIII(OH)2)+NO3-·H2O Layered Double Hydroxides (LDHs) into the anode compartment. Carrying out the measurements with the open-circuit voltage method and using a kinetic format, it has been shown that the introduction of LDHs in the anodic compartment implies a 1.3-fold increase in the calibration sensitivity of the method. This improvement becomes even greater in the presence of hydrogen peroxide in a solution. Furthermore, we show that the calibration sensitivity increased by 8-times, when the fuel cell is modified by the enzyme catalase, crosslinked on LDHs and in the presence of hydrogen peroxide. The fuel cell, thus modified (with or without enzyme), has been used for analytical applications on real samples, such as biological (human saliva) and hand disinfectant samples, commonly used for the prevention of COVID-19, obtaining very positive results from both analytical and kinetic points of view on ethanol detection. Moreover, if the increase in the calibration sensitivity is of great importance from the point of view of analytical applications, it must be remarked that the increase in the speed of the ethanol oxidation process in the fuel cell can also be extremely useful for the purposes of improving the energy performance of a DCEFC.
Assuntos
COVID-19 , Etanol , Humanos , Catalase , Saliva , Peróxido de Hidrogênio , HidróxidosRESUMO
In this work, we have described the synthesis and characterization of novel zinc (II) phthalocyanine bearing four 2-(2,4-dichloro-benzyl)-4-(1,1,3,3-tetramethyl-butyl)-phenoxy substituents on the peripheral positions. The compound was characterized by elemental analysis and different spectroscopic techniques, such as FT-IR, 1H NMR, MALDI-TOF, and UV-Vis. The Zn (II) phthalocyanine shows excellent solubility in organic solvents such as dichloromethane (DCM), n-hexane, chloroform, tetrahydrofuran (THF), and toluene. Photochemical and electrochemical characterizations of the complex were performed by UV-Vis, fluorescence spectroscopy, and cyclic voltammetry. Its good solubility allows a direct deposition of this compound as film, which has been tested as a solid-state sensing material in gravimetric chemical sensors for gas detection, and the obtained results indicate its potential for qualitative discrimination and quantitative assessment of various volatile organic compounds, among them methanol, n-hexane, triethylamine (TEA), toluene and DCM, in a wide concentration range.
RESUMO
Tuberculosis (TB) is among the more frequent causes of death in many countries. For pulmonary TB, early diagnosis greatly increases the efficiency of therapies. Although highly sensitive tests based on nucleic acid amplification tests (NAATs) and loop-mediated isothermal amplification (TB-LAMP) are available, smear microscopy is still the most widespread diagnostics method in most low-middle-income countries, and the true positive rate of smear microscopy is lower than 65%. Thus, there is a need to increase the performance of low-cost diagnosis. For many years, the use of sensors to analyze the exhaled volatile organic compounds (VOCs) has been proposed as a promising alternative for the diagnosis of several diseases, including tuberculosis. In this paper, the diagnostic properties of an electronic nose (EN) based on sensor technology previously used to identify tuberculosis have been tested on-field in a Cameroon hospital. The EN analyzed the breath of a cohort of subjects including pulmonary TB patients (46), healthy controls (38), and TB suspects (16). Machine learning analysis of the sensor array data allows for the identification of the pulmonary TB group with respect to healthy controls with 88% accuracy, 90.8% sensitivity, 85.7% specificity, and 0.88 AUC. The model trained with TB and healthy controls maintains its performance when it is applied to symptomatic TB suspects with a negative TB-LAMP. These results encourage the investigation of electronic noses as an effective diagnostic method for future inclusion in clinical practice.
Assuntos
Tuberculose Pulmonar , Tuberculose , Humanos , Tuberculose/diagnóstico , Tuberculose Pulmonar/diagnóstico , Testes Respiratórios/métodos , Microscopia , Técnicas de Amplificação de Ácido Nucleico/métodos , Expiração , Sensibilidade e EspecificidadeRESUMO
Indoor locations with limited air exchange can easily be contaminated by harmful volatile compounds. Thus, is of great interest to monitor the distribution of chemicals indoors to reduce associated risks. To this end, we introduce a monitoring system based on a Machine Learning approach that processes the information delivered by a low-cost wearable VOC sensor incorporated in a Wireless Sensor Network (WSN). The WSN includes fixed anchor nodes necessary for the localization of mobile devices. The localization of mobile sensor units is the main challenge for indoor applications. Yes. The localization of mobile devices was performed by analyzing the RSSIs with machine learning algorithms aimed at localizing the emitting source in a predefined map. Tests performed on a 120 m2 meandered indoor location showed a localization accuracy greater than 99%. The WSN, equipped with a commercial metal oxide semiconductor gas sensor, was used to map the distribution of ethanol from a point-like source. The sensor signal correlated with the actual ethanol concentration as measured by a PhotoIonization Detector (PID), demonstrating the simultaneous detection and localization of the VOC source.
RESUMO
Legionellosis is a generic term describing the pneumonic (Legionnaires' disease, LD) and non-pneumonic (Pontiac fever, PF) forms of infection with bacteria belonging to the genus Legionella. Currently, the techniques used to detect Legionella spp. in water samples have certain limitations and drawbacks, and thus, there is a need to identify new tools to carry out low-cost and rapid analysis. In this regard, several studies demonstrated that a volatolomics approach rapidly detects and discriminates different species of microorganisms via their volatile signature. In this paper, the volatile organic compounds (VOCs) pattern emitted in vitro by Legionella pneumophila cultures is characterized and compared to those produced by other Legionella species and by Pseudomonas aeruginosa, using a gas sensor array and gas chromatograph mass spectrometer (GC-MS). Bacterial cultures were measured at the 3rd and 7th day after the incubation. Sensor array data analyzed via the K-nearest neighbours (k-NN) algorithm showed a sensitivity to Legionella pneumophila identification at around 89%. On the other hand, GC-MS identified a bouquet of VOCs, mainly alcohols and ketones, that enable the differentiation of Legionella pneumophila in respect to other waterborne microorganisms.
Assuntos
Legionella pneumophila , Legionella , Doença dos Legionários , Humanos , Projetos Piloto , Cromatografia Gasosa-Espectrometria de Massas , Doença dos Legionários/diagnóstico , Doença dos Legionários/microbiologiaRESUMO
Conjugating the porphyrin ring with an amino acid via amide linkage represents a straightforward way for conferring both amphiphilicity and chirality to the macrocycle. Proline residue is a good choice in this context since its conformational rigidity allows for porphyrin assembling where molecular chirality is efficiently transferred and amplified using properly honed aqueous environments. Herein, we describe the evolution of the studies carried out by our group to achieve chiral systems from some porphyrin-proline derivatives, both in solution and in the solid state. The discussion focuses on some fundamental aspects reflecting on the final molecular architectures obtained, which are related to the nature of the appended group (stereochemistry and charge), the presence of a metal ion coordinated to the porphyrin core and the bulk solvent properties. Indeed, fine-tuning the mentioned parameters enables the achievement of stereospecific structures with distinctive chiroptical and morphological features. Solid films based on these chiral systems were also obtained and their recognition abilities in gaseous and liquid phase are here described.
Assuntos
Porfirinas , Porfirinas/química , Solventes/química , Prolina , Conformação Molecular , ÁguaRESUMO
In this paper, a novel non-enzymatic modified glassy carbon (GC) sensor, of the (GC-Agpaste)-catalytic proline-assisted LDH type, for H2O2 determination was fabricated, studied, characterized and employed to determine the hydrogen peroxide content in healthy and diabetic human urine. LDH (whose composition can be schematized as [ZnIIAlIII (OH)2]+ NO3-·nH2O) is glued to glassy carbon by means of silver paste, while proline, which increases the catalytic properties of LDH, is used free in solution in the phosphate buffer. A voltametric survey was first conducted to ascertain the positive effect induced by the presence of proline, i.e., the increase of sensor sensitivity. Then a deep study of the new three-electrode amperometric proline-assisted LDH sensor, whose working electrode was of the same type as the one used to perform the cyclic voltammetry, was carried out, working at first in static air, then in a nitrogen atmosphere. Possible interferences from various substances, both oxidants and antioxidants, were also investigated. Lastly, the new amperometric sensor was successfully used to determine the H2O2 level in human urine from both healthy and diabetic subjects. The effect of proline in enhancing the properties of the sensor system was also investigated. The limit of detection (LOD) of the new catalytic sensor was of the order of 0.15 mmol L-1, working in air, and of 0.05 µmol L-1, working in nitrogen atmosphere.
Assuntos
Diabetes Mellitus , Peróxido de Hidrogênio , Carbono/química , Técnicas Eletroquímicas , Eletrodos , Humanos , Peróxido de Hidrogênio/química , Nitrogênio , Oxidantes , Fosfatos , Prolina , Prata/químicaRESUMO
The realization of an unobtrusive and effective technology able to track fish freshness in real time and inform on its edibility is highly demanded, but still unachieved. In the present paper, we address this issue through a single metal oxide gas sensor working in temperature modulation mode. The system can work without an external reference air source, which is an appealing feature for its possible integration in domestic refrigerators. Tests were carried out using fresh sea bream fillets as case study and working both inside the refrigerator and at room temperature. Parallel gas chromatography-mass spectrometry and microbiological characterization indicated the marked dependence of both the microbiological condition and the gas-phase composition from the individual sample and from the storage temperature. Despite such a large variability, which may be expected in real applications, the proposed system provided similar responses whenever the total bacterial population approached and exceeded the edibility threshold of 107 CFU/g.
Assuntos
Dourada , Animais , Bactérias , Cromatografia Gasosa-Espectrometria de Massas , Óxidos , TemperaturaRESUMO
Currently, in clinical practice there is a pressing need for potential biomarkers that can identify lung cancer at early stage before becoming symptomatic or detectable by conventional means. Several researchers have independently pointed out that the volatile organic compounds (VOCs) profile can be considered as a lung cancer fingerprint useful for diagnosis. In particular, 16% of volatiles contributing to the human volatilome are found in urine, which is therefore an ideal sample medium. Its analysis through non-invasive, relatively low-cost and straightforward techniques could offer great potential for the early diagnosis of lung cancer. In this study, urinary VOCs were analysed with a gas chromatography-ion mobility spectrometer (GC-IMS) and an electronic nose (e-nose) made by a matrix of twelve quartz microbalances complemented by a photoionization detector. This clinical prospective study involved 127 individuals, divided into two groups: 46 with lung cancer stage I-II-III confirmed by computerized tomography or positron emission tomography-imaging techniques and histology (biopsy), and 81 healthy controls. Both instruments provided a multivariate signal which, after being analysed by a machine learning algorithm, identified eight VOCs that could distinguish lung cancer patients from healthy ones. The eight VOCs are 2-pentanone, 2-hexenal, 2-hexen-1-ol, hept-4-en-2-ol, 2-heptanone, 3-octen-2-one, 4-methylpentanol, 4-methyl-octane. Results show that GC-IMS identifies lung cancer with respect to the control group with a diagnostic accuracy of 88%. Sensitivity resulted as being 85%, and specificity was 90%-Area Under the Receiver Operating Characteristics: 0.91. The contribution made by the e-nose was also important, even though the results were slightly less sensitive with an accuracy of 71.6%. Moreover, of the eight VOCs identified as potential biomarkers, five VOCs had a high sensitivity (p⩽ 0.06) for early stage (stage I) lung cancer.
Assuntos
Neoplasias Pulmonares , Compostos Orgânicos Voláteis , Biomarcadores/análise , Testes Respiratórios/métodos , Detecção Precoce de Câncer , Nariz Eletrônico , Humanos , Neoplasias Pulmonares/diagnóstico , Estudos Prospectivos , Compostos Orgânicos Voláteis/análiseRESUMO
Optical chemical sensors are widely applied in many fields of modern analytical practice, due to their simplicity in preparation and signal acquisition, low costs, and fast response time. Moreover, the construction of most modern optical sensors requires neither wire connections with the detector nor sophisticated and energy-consuming hardware, enabling wireless sensor development for a fast, in-field and online analysis. In this review, the last five years of progress (from 2017 to 2021) in the field of optical chemical sensors development for persistent organic pollutants (POPs) is provided. The operating mechanisms, the transduction principles and the types of sensing materials employed in single selective optical sensors and in multisensory systems are reviewed. The selected examples of optical sensors applications are reported to demonstrate the benefits and drawbacks of optical chemical sensor use for POPs assessment.