Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Front Bioeng Biotechnol ; 12: 1386713, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38798957

RESUMO

Introduction: Prompt reperfusion of coronary artery after acute myocardial infarction (AMI) is crucial for minimizing heart injury. The myocardium, however, may experience additional injury due to the flow restoration itself (reperfusion injury, RI). The purpose of this study was to demonstrate that short preconditioning (10 min) with selective autoretroperfusion (SARP) ameliorates RI, based on a washout hypothesis. Methods: AMI was induced in 23 pigs (3 groups) by occluding the left anterior descending (LAD) artery. In SARP-b (SARP balloon inflated) and SARP-nb (SARP balloon deflated) groups, arterial blood was retroperfused for 10 min via the great cardiac vein before releasing the arterial occlusion. A mathematical model of coronary circulation was used to simulate the SARP process and evaluate the potential washout effect. Results: SARP restored left ventricular function during LAD occlusion. Ejection fraction in the SARP-b group returned to baseline levels, compared to SARP-nb and control groups. Infarct area was significantly larger in the control group than in the SARP-b and SARP-nb groups. End-systolic wall thickness was preserved in the SARP-b compared to the SARP-nb and control groups. Analyte values (pH, lactate, glucose, and others), measured every 2 min during retroperfusion, suggest a "washout" effect as one important mechanism of action of SARP in reducing infarct size. With SARP, the values progressively approached baseline levels. The mathematical model also confirmed a possible washout effect of tracers. Discussion: RI can be ameliorated by delaying restoration of arterial flow for a brief period of time while pretreating the infarction with SARP to restore homeostasis via a washout mechanism.

2.
PLoS One ; 19(4): e0296652, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38626037

RESUMO

INTRODUCTION: Stress is characterized as a challenging occurrence that triggers a physiological and/or behavioral allostatic response, alongside the demands typically encountered throughout the natural course of life. A sustained state of stress gives rise to secondary effects, including insomnia and neck pain. Also, the risk of musculoskeletal problems in the cervical and lumbar spine can be increased due to a sustained state of stress. The present study main objective is to study the association between orofacial and pelvic floor muscles in women in Spain. METHODOLOGY: An observational, cross-sectional, retrospective analytical study was designed and carried out in the laboratories of the European University of Madrid. Sixty-five participants were recruited with a mean age of 29.9 ± 7.69. Measurements were taken by myotonometry on natural oscillation frequency (Hz), dynamic stiffness (N/m), elasticity (N/m2), mechanical stress relaxation time (ms) and creep, for the following muscles: right and left masseter, right and left temporalis and central fibrous nucleus of the perineum (CFPF). On the other hand, the subjects completed the following questionnaires: perceived stress scale (PSS-14), anxiety scale (STAI), self-reported bruxism questionnaire (CBA), Fonseca Anamnestic Index and the Pittsburgh Sleep Quality Scale (PSQI). RESULTS: Significant correlations were found in several parameters between the right temporalis and CFPF (p<0.05). Highlighting the correlation between TMDs and lubrication r = -0.254 (p = 0.041) and bruxism with pain in sexual intercourse r = 0.261 (p = 0.036). CONCLUSION: The results support the proposed hypothesis. To the author's knowledge, this is the first study which relates both locations, and it is suggested to continue with the research and expand the knowledge of it.


Assuntos
Bruxismo , Distúrbios do Assoalho Pélvico , Testes Psicológicos , Autorrelato , Humanos , Feminino , Adulto Jovem , Adulto , Bruxismo/epidemiologia , Estudos Transversais , Estudos Retrospectivos
3.
Front Cardiovasc Med ; 10: 1233712, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38094118

RESUMO

Stroke is the second leading cause of death worldwide. Nearly two-thirds of strokes are produced by cardioembolisms, and half of cardioembolic strokes are triggered by Atrial Fibrillation (AF), the most common type of arrhythmia. A more recent cause of cardioembolisms is Transcatheter Aortic Valve Replacements (TAVRs), which may onset post-procedural adverse events such as stroke and Silent Brain Infarcts (SBIs), for which no definitive treatment exists, and which will only get worse as TAVRs are implanted in younger and lower risk patients. It is well known that some specific characteristics of elderly patients may lower the safety and efficacy of anticoagulation therapy, making it a real urgency to find alternative therapies. We propose a device consisting of a strut structure placed at the base of the treated artery to model the potential risk of cerebral embolisms caused by dislodged debris of varying sizes. This work analyzes a design based on a patented medical device, intended to block cardioembolisms from entering the cerebrovascular system, with a particular focus on AF, and potentially TAVR patients. The study has been carried out in two stages. Both of them based on computational fluid dynamics (CFD) coupled with Lagrangian particle tracking method. The first stage of the work evaluates a variety of strut thicknesses and inter-strut spacings, contrasting with the device-free baseline geometry. The analysis is carried out by imposing flowrate waveforms characteristic of both healthy and AF patients. Boundary conditions are calibrated to reproduce physiological flowrates and pressures in a patient's aortic arch. In the second stage, the optimal geometric design from the first stage was employed, with the addition of lateral struts to prevent the filtration of particles and electronegatively charged strut surfaces, studying the effect of electrical forces on the clots if they are considered charged. Flowrate boundary conditions were used to emulate both healthy and AF conditions. Results from numerical simulations coming form the first stage indicate that the device blocks particles of sizes larger than the inter-strut spacing. It was found that lateral strut space had the highest impact on efficacy. Based on the results of the second stage, deploying the electronegatively charged device in all three aortic arch arteries, the number of particles entering these arteries was reduced on average by 62.6% and 51.2%, for the healthy and diseased models respectively, matching or surpassing current oral anticoagulant efficacy. In conclusion, the device demonstrated a two-fold mechanism for filtering emboli: while the smallest particles are deflected by electrostatic repulsion, avoiding microembolisms, which could lead to cognitive impairment, the largest ones are mechanically filtered since they cannot fit in between the struts, effectively blocking the full range of particle sizes analyzed in this study. The device presented in this manuscript offers an anticoagulant-free method to prevent stroke and SBIs, imperative given the growing population of AF and elderly patients.

4.
Front Cardiovasc Med ; 10: 1208903, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37790598

RESUMO

Background: Chronic coronary retroperfusion to treat myocardial ischemia has previously failed due to edema and hemorrhage of coronary veins suddenly exposed to arterial pressures. The objective of this study was to selectively adapt the coronary veins to become arterialized prior to coronary venous retroperfusion to avoid vascular edema and hemorrhage. Methods and results: In 32 animals (Group I = 19 and Group II = 13), the left anterior descending (LAD) artery was occluded using an ameroid occlusion model. In Group I, the great cardiac vein was blocked with suture ligation (Group IA = 11) or with occlusion device (Group IB = 8) to arterialize the venous system within 2 weeks at intermediate pressure (between arterial and venous levels) before a coronary venous bypass graft (CVBG) was implemented through a left internal mammary artery (LIMA) anastomosis. Group II only received the LAD artery occlusion and served as control. Serial echocardiograms showed recovery of left ventricular (LV) function with this adaptation-arterialization approach, with an increase in ejection fraction (EF) in Group I from 38% ± 5% after coronary occlusion to 53% ± 7% eight weeks after CVBG, whereas in Group II the EF never recovered (41% ± 2%-33% ± 7%). The remodeling of the venous system not only allowed restoration of myocardial function when CVBG was implemented but possibly promoted a novel form of "collateralization" between the native arterioles and the newly arterialized venules, which revascularized the ischemic myocardium. Conclusions: These findings form a potential rationale for a venous arterialization-revascularization treatment for the refractory angina and the "no-option" patients using a hybrid percutaneous (closure device for arterialization)/surgical approach (CVBG) to revascularize the myocardium.

5.
Biology (Basel) ; 11(11)2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36358280

RESUMO

Introduction: The purpose of this study was to delve more deeply into the medium and long-term relation between mRNA-based vaccines and changes in menstrual pain, cycle length, and amount of bleeding in Spanish women. Material and Methods: A total of 746 women (63% between 18−30 and 37% between 31−45 years old) participated in the study. A numerical rating scale was used for recording pain intensity, a pictorial chart for menstrual bleeding, and data from menstrual cycle duration, type of vaccine, number of doses and time from vaccination. Results: Sixty-five per cent of the women perceived changes in their menstrual cycle after receiving the vaccines, irrespective of type of vaccine or number of doses; all p values were >0.05. Most of them (n = 316 out of 484) reported more than one alteration in their menstrual cycle. Almost half of the participants had been vaccinated over 5 months (45%), 3−4 months (15%) 2−3 months (26%), and one month or less (13%) before. The percentage of women that reported alterations remained strongly constant across time, p > 0.05, ranging from 64 to 65%. Conclusions: Reported alterations in Spanish women after COVID vaccination remained more than 5 months after the last dose.

6.
J Hum Kinet ; 82: 243-252, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36196348

RESUMO

Every parasport is currently encouraged to consider evidence-based classification to develop their respective classification system. Therefore, the aims of this study were to: (1) assess the relationship between trunk function and anaerobic power determining proficiency in wheelchair basketball, and (2) define "natural classes" in wheelchair basketball based on anaerobic power. Fifty-nine elite players (representing five national teams) were divided into four main functional classes: Group 1 (n=17), Group 2 (n=14), Group 3 (n=16), Group 4 (n=12). They performed the 6x10s Anaerobic Power Test using an arm crank ergometer. Average values of mean power, peak power, relative mean power, relative peak power, and power decrement were calculated for the 6x10s and 3x10s tests. The Spearman's correlation matrix revealed significant correlations between classes and values recorded in the 6x10s test. This confirmation between anaerobic power and players' classification endorses the division of players into different classes. Furthermore, cluster analysis (with fair quality) divided players into two "natural classes". The first resulting class was mainly formed of participants from Group 1 (71%). An important complement to this research could be to consider wheelchair acceleration and the volume of trunk action in wheelchair basketball classification.

7.
J Sports Sci ; 40(1): 16-23, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34530683

RESUMO

The aim of the current experiment was to examine the spatiotemporal control of expert tennis players while executing first service returns within a representative experimental setting. We recruited and tested 12 male expert tennis players in hard courts. A comprehensive analysis of the timing (eleven temporal variables analysed at 300 Hz) and performance success of the return actions were carried out, while simultaneously considering task constraints such as the accuracy and the speed of the serves. Temporal organisation of return actions were scaled relative to the server's racket-ball contact (5 ms), an adaptation of fly-time of the split-step, which resulted in consistent landings (133 ms), and initiation of lateral movements towards the ball - with no response errors - after the server's stroke (around 177 ms). Poorer returns occurred when responding to accurate serves accompanied by late trunk movements towards the ball. Returners scaled the timing of the response to the unfolding action of the serve in order to support both spatial and temporal accuracy. These novel findings highlight the significance of the study of fast-ball sports in representative settings and offer further detail on the spatiotemporal control of skilful perception-action.


Assuntos
Tênis , Animais , Fenômenos Biomecânicos , Masculino , Movimento , Percepção , Tronco
8.
Sports Biomech ; : 1-10, 2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-34016018

RESUMO

The main aims of the present research were 1) to characterise the inter-subject and intra-subject timing of the preparatory movements of competitive swimmers during relay starts and 2) to relate the preparatory movements with the relay start outcome. Nine international youth swimmers performed 10 relay freestyle starts (one-step technique) filmed at 120 Hz from a lateral viewpoint. Results obtained (0.14 ± 0.10 s changeover time, 0.31 ± 0.07 s entry time, 2.59 ± 0.09 m entry distance and 0.96 ± 0.06 s time to 5 m) indicated that the longer the preparation time (from the initial position to the swimmer's take-off), the better the changeover time, entry distance, and 5 m time. Specifically, a mixed linear model identified preparation time (p < 0.001, F (1,80.01) = 56.36), and entry distance (p = 0.008, F (1,80.01) = 7.36) as predicting variables for 5 m time. Also, faster swimmers on times to 5 m were found to be more consistent - lower levels of intra-subject variability - in 5 m (r = 0.76, p = 0.018) and changeover (r = 0.72, p = 0.029) times. In summary, the timing of the preparatory movements seems to be a key aspect to optimise relay start performances.

9.
Front Psychol ; 11: 523691, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33192764

RESUMO

The purpose of this paper is to explain learning in sports and physical education (PE) from the perspective of enactive and ecological psychology. The learning process is first presented from the enactive perspective, and some relevant notions such as sense-making and sensorimotor schemes are developed. Then, natural learning environments are described, and their importance in the human development process is explained. This is followed by a section devoted to the learner's experience in which some research methods are explained, such as neurophenomenology, in addition to self-confrontation, interviews aimed at bringing out the meaning, sensations, and emotions that performers experience when they are immersed in their sport or a PE class. The sections on the ecological approach deal with the attunement, calibration, the education of intention, and the importance of representative experimental designs. The last section addresses the main similarities and differences between the two approaches. Finally, we state our theoretical position in favor of a common project that brings together the main elements of both post-cognitive approaches.

10.
JACC Basic Transl Sci ; 5(3): 267-278, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32215349

RESUMO

Mild hypothermia (MH) and retroperfusion are 2 techniques proposed to reduce infarct size due to myocardial infarction. The authors evaluated the effects of focal MH combined with selective coronary venous autoretroperfusion (SARP) as an acute cardioprotective modality before percutaneous coronary intervention (PCI) in a swine model of left ventricular myocardial infarction. Significant reduction in infarct size with preservation of cardiac function and cardiomyocyte viability were achieved. The authors propose that SARP alone or in combination with MH may provide a clinically relevant percutaneous short-term option of cardiac support to high-risk patients undergoing PCI.

11.
Front Psychol ; 10: 1438, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31316423

RESUMO

This study addressed the question whether coaches better allow athletes to self-control their decisions when under pressure or whether to impose a decision upon them. To this end, an experiment was conducted that manipulated the soccer kickers' degree of control in decision-making. Two groups of elite under-19 soccer players (n = 18) took penalty kicks in a self-controlled (i.e., kickers themselves decided to which side to direct the ball) and an externally controlled condition (i.e., the decision to which side to direct the ball was imposed upon the kickers). One group performed the penalty kick under psychological pressure (i.e., the present coaching staff assessed their performance), while the second group performed without pressure. Just before and after performing the kicks, CSAI-2 was used to measure cognitive and somatic anxiety and self-confidence. Further, the number of goals scored, ball placement and speed, and the duration of preparatory and performatory behaviors were determined. The results verified increased levels of cognitive and somatic anxiety after performing the kicks in the pressured group compared to the no-pressure group. In addition, degree of self-control affected the participants' performance, particularly in the pressured group. They scored more goals and placed the kicks higher in the self-controlled than in the externally-controlled condition. Participants also took more time preparing and performing the run-up in the self-controlled condition. Findings indicate that increased self-control helps coping with the debilitating effects of pressure and can counter performance deteriorations. The findings are discussed within the framework of self-control theories, and recommendations for practitioners and athletes are made.

12.
Sci Rep ; 7(1): 7065, 2017 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-28765648

RESUMO

Stroke is a life threatening event that is expected to more than double over the next 40 years. Atrial fibrillation (AF) has been reported as a strong independent risk factor for stroke. We have previously shown that a hemodynamic perturbation by AF or reduced cardiac output and cycle length may have a significant impact on clot trajectory and thus embolic stroke propensity through the left common carotid artery using an idealized aortic arch model. Here, we show the dependence of flow patterns and hence stroke propensity on geometry of patient-specific aortas. We performed computational fluid dynamics (CFD) simulations to determine the variations of AF-induced stroke propensity over various image-based patient-dependent aorta models. The results demonstrated that curvature pattern of aorta can play a determinant role in AF-induced stroke propensity alteration. Specifically, it was shown that the hemodynamic perturbation by AF considered led to substantial increase in stroke propensity (i.e., 2.5~3.8 fold elevation) for lower curvature angle <90° while the changes in stroke propensity by AF are negligible for higher curvature angle >90°. The present simulations suggest that aortic arch curvature is an important risk factor for embolic stroke which should be tested in future clinical trials.


Assuntos
Aorta/anatomia & histologia , Simulação por Computador , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/fisiopatologia , Humanos , Hidrodinâmica , Fluxo Sanguíneo Regional , Medição de Risco
13.
J Exp Psychol Hum Percept Perform ; 43(4): 783-793, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28345945

RESUMO

It is widely accepted that the sources of information used to guide interceptive actions depend on conflicting spatiotemporal task demands. However, there is a paucity of evidence that shows how information pick-up during interceptive actions is adapted to such conflicting constraints. The present study therefore examined the effects of systematic manipulations of spatiotemporal constraints on performance, timing and gaze in an in situ interceptive action. To this end, expert futsal goalkeepers faced penalty kicks taken from 10 m and 6 m. With the more lenient spatiotemporal constraints (i.e., kicks from 10 m), the goalkeepers saved more kicks, initiated their actions later, and looked longer toward ball relative to the penalty takers' body. Furthermore, analysis of gaze patterns showed that interindividual variations in information pick-up were related to the unfolding of the penalty taker's action, revealing a less variable, funnel-like gaze pattern toward the end of the action. These findings are interpreted to reflect that changes in spatiotemporal demands induce the differential use of information for the accurate control of interceptive actions. (PsycINFO Database Record


Assuntos
Antecipação Psicológica/fisiologia , Movimentos Oculares/fisiologia , Desempenho Psicomotor/fisiologia , Futebol/fisiologia , Percepção Espacial/fisiologia , Adolescente , Adulto , Medições dos Movimentos Oculares , Humanos , Masculino , Fatores de Tempo , Adulto Jovem
14.
EuroIntervention ; 12(12): 1534-1541, 2016 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-27998846

RESUMO

AIMS: Percutaneous structural heart therapies, such as mitral value repair, require site-specific transseptal access (TSA). This can be challenging for interventional cardiologists. We describe a TSA catheter (TSAC) that utilises suction for enhanced control and puncture accuracy. Here, we aim to evaluate the safety and efficacy of the device. METHODS AND RESULTS: Ex vivo interatrial septum preparations were dissected from swine (n=8) and diseased human hearts (n=6) to quantify TSAC suction and needle puncture force. TSAC suction was 6.5-fold greater than the opposing needle puncture force, and thus provides sufficient stabilisation for punctures. The safety and efficacy of TSAC was evaluated in a chronic mitral regurgitation swine model (n=10) and compared to a conventional TSA device. MR was induced by disrupting one to three mitral chordae tendineae, and the progression of heart disease was followed for three weeks. During device testing, procedure time and fluoroscopy exposure were not statistically different between devices. TSAC reduced septal displacement from 8.7±0.30 mm to 3.60±0.19 mm (p<0.05) and improved puncture accuracy 1.75-fold. CONCLUSIONS: TSAC provides controlled TSA and improves puncture accuracy, while maintaining procedure time and workflow. These findings provide a strong rationale for a first-in-man study to demonstrate the clinical utility of the device.


Assuntos
Septo Interatrial/cirurgia , Desenho de Equipamento , Septos Cardíacos/cirurgia , Punções , Sucção , Animais , Cateterismo Cardíaco/instrumentação , Ablação por Cateter/instrumentação , Feminino , Humanos , Masculino , Punções/métodos , Sucção/métodos , Suínos
15.
J Biomech ; 48(10): 1789-95, 2015 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-26049978

RESUMO

Atrial fibrillation (AF) is a dysfunction of heart rhythm and represents an increased predisposition to ischemic stroke in AF patients. It has been shown that the AF-induced hemodynamic conditions may contribute to the increased embolic propensity through the carotid arteries. We simulated a stroke-prevention device with a unique strut structure to deflect the trajectory of a blood clot to the carotid artery. We identified the important determinants of functionality in a device design using computational fluid dynamics simulations. Quantitative assessment of deflection efficacy over various clot dimensions was carried out for the device with different strut configurations under AF flow conditions. The simulations demonstrate that the trajectory of a clot destined to the left common carotid artery (LCCA) can be deflected by a strut-structured device at the LCCA inlet with virtually no change in flow resistance. The deflection efficacy of the device is dependent on the clot properties and strut designs of the device. A configuration of 0.75 mm thick and 0.75 mm distant struts with 50% of surface convexity were found to provide maximum deflection efficacy (e.g., 36% greater deflection efficacy than a flat filter) among the strut structures considered. The results suggest that a deflector stent implanted in the aortic branch may be an effective stroke-prevention device. The present simulations motivate pre-clinical animal studies as well as further studies on patient-specific design of the device that maximize the deflection efficacy while minimizing device safety issues.


Assuntos
Modelos Cardiovasculares , Stents , Acidente Vascular Cerebral/prevenção & controle , Trombose/fisiopatologia , Trombose/terapia , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Artéria Carótida Primitiva/fisiopatologia , Embolia/complicações , Embolia/fisiopatologia , Embolia/terapia , Hemodinâmica , Humanos , Acidente Vascular Cerebral/etiologia , Trombose/complicações
16.
Obes Surg ; 24(1): 159-66, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24214283

RESUMO

BACKGROUND: Bariatric surgery using laparoscopic techniques is the most effective treatment for morbid obesity. The objective of the study is to assess the safety and efficacy of a novel laparoscopic reversible gastric restrictive (RGR) device in a group of obese dogs. An implant was also performed in a cadaver to assess implant feasibility in a human. METHODS: Four obese mongrel dogs were subjected to RGR implantation for 3 months followed by recovery for an additional 6 weeks after device removal. Food intake, body weight, radiographic barium imaging, and gastric endoscopy were used to monitor RGR performance before implant, after implant, and implant removal. An additional RGR laparoscopic implantation procedure was performed in a human cadaver. RESULTS: The implanted obese dogs exhibited a significant decrease in food intake and body weight over 3 months with the RGR device. The reduction of food intake was sustained at an average of 46 % after implant and the excess weight loss reached an average of 75 % at the end of 12 weeks with recovery to approximately 78 % of baseline after 6 weeks of implant removal. Barium imaging and gastric endoscopy both confirmed passage for food through the restrictive device channel in the stomach. The RGR device was successfully implanted laparoscopically on the cadaver stomach in less than an hour. CONCLUSIONS: The RGR device is laparoscopically deliverable and removable with effective and sustainable weight loss over a 12-week period in an obese dog model. The implant is also technically feasible in man.


Assuntos
Gastroplastia/instrumentação , Obesidade/cirurgia , Próteses e Implantes , Animais , Cadáver , Modelos Animais de Doenças , Cães , Ingestão de Alimentos , Estudos de Viabilidade , Feminino , Humanos , Laparoscopia , Masculino , Implantação de Prótese , Resultado do Tratamento , Redução de Peso
17.
PLoS One ; 8(9): e73769, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24058488

RESUMO

It is well known that flow patterns at the anastomosis of coronary artery bypass graft (CABG) are complex and may affect the long-term patency. Various attempts at optimal designs of anastomosis have not improved long-term patency. Here, we hypothesize that mild anastomotic stenosis (area stenosis of about 40-60%) may be adaptive to enhance the hemodynamic conditions, which may contribute to slower progression of atherosclerosis. We further hypothesize that proximal/distal sites to the stenosis have converse changes that may be a risk factor for the diffuse expansion of atherosclerosis from the site of stenosis. Twelve (12) patient-specific models with various stenotic degrees were extracted from computed tomography images using a validated segmentation software package. A 3-D finite element model was used to compute flow patterns including wall shear stress (WSS) and its spatial and temporal gradients (WSS gradient, WSSG, and oscillatory shear index, OSI). The flow simulations showed that mild anastomotic stenosis significantly increased WSS (>15 dynes · cm(-2)) and decreased OSI (<0.02) to result in a more uniform distribution of hemodynamic parameters inside anastomosis albeit proximal/distal sites to the stenosis have a decrease of WSS (<4 dynes · cm(-2)). These findings have significant implications for graft adaptation and long-term patency.


Assuntos
Constrição Patológica/cirurgia , Ponte de Artéria Coronária , Vasos Coronários/cirurgia , Modelos Cardiovasculares , Software , Anastomose Cirúrgica , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Constrição Patológica/diagnóstico por imagem , Constrição Patológica/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Radiografia , Estudos Retrospectivos , Resistência ao Cisalhamento , Estresse Mecânico
18.
PLoS One ; 8(9): e73485, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24039957

RESUMO

Atrial fibrillation (AF) is the most common sustained dysfunction in heart rhythm clinically and has been identified as an independent risk factor for stroke through formation and embolization of thrombi. AF is associated with reduced cardiac output and short and irregular cardiac cycle length. Although the effect of AF on cardiac hemodynamic parameters has been reported, it remains unclear how the hemodynamic perturbations affect the potential embolization of blood clots to the brain that can cause stroke. To understand stroke propensity in AF, we performed computer simulations to describe trajectories of blood clots subject to the aortic flow conditions that represent normal heart rhythm and AF. Quantitative assessment of stroke propensity by blood clot embolism was carried out for a range of clot properties (e.g., 2-6 mm in diameter and 0-0.8 m/s ejection speed) under normal and AF flow conditions. The simulations demonstrate that the trajectory of clot is significantly affected by clot properties as well as hemodynamic waveforms which lead to significant variations in stroke propensity. The predicted maximum difference in stroke propensity in the left common carotid artery was shown to be about 60% between the normal and AF flow conditions examined. The results suggest that the reduced cardiac output and cycle length induced by AF can significantly increase the incidence of carotid embolism. The present simulations motivate further studies on patient-specific risk assessment of stroke in AF.


Assuntos
Fibrilação Atrial/complicações , Embolia/etiologia , Hemodinâmica , Acidente Vascular Cerebral/etiologia , Coagulação Sanguínea , Débito Cardíaco , Simulação por Computador , Humanos , Modelos Cardiovasculares , Fatores de Risco
19.
Mech Res Commun ; 42: 134-141, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22778489

RESUMO

Cardiac growth and remodeling in the form of chamber dilation and wall thinning are typical hallmarks of infarct-induced heart failure. Over time, the infarct region stiffens, the remaining muscle takes over function, and the chamber weakens and dilates. Current therapies seek to attenuate these effects by removing the infarct region or by providing structural support to the ventricular wall. However, the underlying mechanisms of these therapies are unclear, and the results remain suboptimal. Here we show that myocardial infarction induces pronounced regional and transmural variations in cardiac form. We introduce a mechanistic growth model capable of predicting structural alterations in response to mechanical overload. Under a uniform loading, this model predicts non-uniform growth. Using this model, we simulate growth in a patient-specific left ventricle. We compare two cases, growth in an infarcted heart, pre-operative, and growth in the same heart, after the infarct was surgically excluded, post-operative. Our results suggest that removing the infarct and creating a left ventricle with homogeneous mechanical properties does not necessarily reduce the driving forces for growth and remodeling. These preliminary findings agree conceptually with clinical observations.

20.
J Surg Res ; 178(1): 165-71, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22459287

RESUMO

BACKGROUND: Variable responses of gut hormones have been observed after bariatric procedures. The aim of the present study was to evaluate the ghrelin, glucagon-like peptide 1 (GLP-1), and leptin levels in nonobese canine and obese rat models after weight loss owing to a reversible gastric restriction (RGR) device. METHODS: Mongrel dogs and obese Zucker rats were submitted to either surgical implantation or a sham operation and were followed up for 6 wk. The serum fasting ghrelin, GLP-1, and leptin levels in dogs were measured using enzyme-linked immunosorbent assay before and after surgical implantation and after implant removal. The protein expression of mucosa ghrelin, GLP-1, and leptin in the dog and rat stomach were measured using Western blotting. RESULTS: The RGR implant in dogs and rats resulted in a significant decrease in food intake and body weight. In the nonobese dog, the serum ghrelin level and mucosa ghrelin expression were significantly increased after surgical implantation (P < 0.05) and tended to recover after implant removal. In the obese rat, mucosa ghrelin expression decreased by about 27% (P = 0.06) 6 wk after implantation. A lower serum leptin level in dogs and lower mucosa leptin expression in dogs and rats was observed after surgical implantation compared with the sham procedure (P < 0.05). The RGR implant had no influence on the serum GLP-1 level in dogs or mucosa GLP-1 expression in either animal model. CONCLUSIONS: Our results showed that ghrelin levels are downregulated with short-term RGR implantation in obese rats but upregulated in nonobese dogs, implying that the energy balance could be an important determinant of ghrelin level. The marked suppression of leptin in both animal models might contribute to the weight-reducing effect of the RGR implant.


Assuntos
Gastroplastia/métodos , Grelina/sangue , Peptídeo 1 Semelhante ao Glucagon/sangue , Leptina/sangue , Obesidade/metabolismo , Obesidade/cirurgia , Animais , Peso Corporal/fisiologia , Modelos Animais de Doenças , Cães , Metabolismo Energético/fisiologia , Mucosa Gástrica/metabolismo , Mucosa Gástrica/cirurgia , Grelina/metabolismo , Peptídeo 1 Semelhante ao Glucagon/metabolismo , Leptina/metabolismo , Ratos , Ratos Zucker , Redução de Peso/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA