Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Assunto principal
Tipo de documento
Intervalo de ano de publicação
1.
Polymers (Basel) ; 14(16)2022 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-36015676

RESUMO

Excessive postoperative scarring halts the effectiveness of glaucoma surgery and still remains a challenging problem. The purpose of this study was to develop a PLA-PEG-based drug delivery system with cyclosporine A or everolimus for wound healing modulation. METHODS: PLA-PEG implants saturation with cyclosporine A or everolimus as well as their further in vitro release were analyzed. Anti-proliferative activity and cytotoxicity of the immunosuppressants were studied in vitro using human Tenon's fibroblasts. Thirty-six rabbits underwent glaucoma filtration surgery with the application of sham implants or samples saturated with cyclosporine A or everolimus. The follow-up period was six months. A morphological study of the surgery area was also performed at seven days, one, and six months post-op. RESULTS: PLA-PEG implants revealed a satisfactory ability to cumulate either cyclosporine A or everolimus. The most continuous period of cyclosporine A and everolimus desorption was 7 and 13 days, respectively. Immunosuppressants demonstrated marked anti-proliferative effect regarding human Tenon's fibroblasts without signs of cytotoxicity at concentrations provided by the implants. Application of PLA-PEG implants saturated with immunosuppressants improved in vivo glaucoma surgery outcomes. CONCLUSIONS: Prolonged delivery of either cyclosporine A or everolimus by means of PLA-PEG implants represents a promising strategy of wound healing modulation in glaucoma filtration surgery.

2.
Biomed Opt Express ; 13(7): 3699-3722, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35991916

RESUMO

Coupling to longitudinal modes of thin spherical shells, under Gaussian-beam illumination, was explored with a theoretical method based on Fourier-optics analysis and vector spherical harmonics and was scrutinized with an experimental setup. For the theory part, the illumination frequency band was fixed between 100-600 GHz and the outer spherical shell radius of curvature and thickness are 7.5 mm and 0.5 mm, respectively. The shell material was either the lossless cornea or an aqueous effective media representing the cornea. Six different beam-target strategies were introduced being potential candidates for maximum coupling. Two dispersion-tuned beam ensembles with strongly frequency-dependent phase center location have been created with a fixed incident beam 1/e radius and radius of curvature called forward strategies. These computations of different alignments were continued with four beam ensembles of frequency-invariant phase center, constructed from fits to experimental data, oriented at four different axial locations with respect to the spherical shell center of curvature, they are called reverse strategies. Coupling efficiency for all strategies was calculated for different targets including perfect electrical conductor (PEC) sphere, PEC core covered by a cornea loss-free layer and cornea. All scattering strategies contrasted to scattering from equivalent planar targets as a reference with maximum coupling. The results show that, under an ideal calibration, forward strategies are a closer approximation to the plane-wave condition for the cornea. An experimental setup was assembled to explore the simulation approach in a frequency range between 220 GHz to 330 GHz. Two different quartz samples with permittivity of 4.1 were mounted on a water core, acting for a cornea. The first and second quartz radius and thickness were 7.5 mm and 0.5 mm and 8 mm and 1 mm, respectively. An adequate agreement between theory and experiment was confirmed. A particle optimisation swarm algorithm was applied to extract the thickness and permittivity of quartz from the measured back-scattered field for reverse strategies.

3.
Sensors (Basel) ; 22(9)2022 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-35590925

RESUMO

Improving the longitudinal modes coupling in layered spherical structure contributes significantly to corneal terahertz sensing, which plays a crucial role in the early diagnosis of cornea dystrophies. Using a steel sphere to calibrate reflection from the cornea sample assists in enhancing the resolution of longitudinal modes. The requirement and challenges toward applying the calibration sphere are introduced and addressed. Six corneas with different properties are spotted to study the effect of perturbations in the calibration sphere in a frequency range from 100 GHz to 600 GHz. A particle-swarm optimization algorithm is employed to quantify corneal characteristics considering cases of accurately calibrated and perturbed calibrated scenarios. For the first case, the study is carried out with signal-to-noise values of 40 dB, 50 dB and 60 dB at waveguide bands WR-5.1, WR-3.4, and WR-2.2. As expected, better estimation is achieved in high-SNR cases. Furthermore, the lower waveguide band is revealed as the most proper band for the assessment of corneal features. For perturbed cases, the analysis is continued for the noise level of 60 dB in the three waveguide bands. Consequently, the error in the estimation of corneal properties rises significantly (around 30%).


Assuntos
Imagem Terahertz , Algoritmos , Calibragem , Córnea/diagnóstico por imagem , Refração Ocular
4.
Materials (Basel) ; 14(23)2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34885553

RESUMO

Thin layers of silver nanowires are commonly studied for transparent electronics. However, reports of their terahertz (THz) properties are scarce. Here, we present the electrical and optical properties of thin silver nanowire layers with increasing densities at THz frequencies. We demonstrate that the absorbance, transmittance and reflectance of the metal nanowire layers in the frequency range of 0.2 THz to 1.3 THz is non-monotonic and depends on the nanowire dimensions and filling factor. We also present and validate a theoretical approach describing well the experimental results and allowing the fitting of the THz response of the nanowire layers by a Drude-Smith model of conductivity. Our results pave the way toward the application of silver nanowires as a prospective material for transparent and conductive coatings, and printable antennas operating in the terahertz range-significant for future wireless communication devices.

5.
Inorg Chem ; 58(8): 5058-5068, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30907600

RESUMO

Reduction of terbium(III) double-decker phthalocyanine, TbIIIPc2 (1), by sodium fluorenone ketyl in the presence of bis(triphenylphosphoranylidene)ammonium cations yields one-electron-reduced (PPN+){TbIII(Pc2-)2}-·2.5C6H4Cl2 (2) containing the dianionic Pc2- macrocycles, whereas a stronger NaCpCo(CO)2 reductant in the presence of an excess of cryptand yields two-electron-reduced {Cryptand(Na+)}2{(Pc2-)TbIII(Pc•3-)}2- (3) containing the Pc•3- radical trianionic macrocycle. Isolated pairs of the {TbIII(Pc2-)2}- anions are formed in 2, whereas compound 3 has unique 3D packing of the macrocycles with weak π-orbitals overlapping in all three directions. This is the first example of the two-electron-reduced lanthanide double-decker containing Pc•3- radical trianion studied in solid state. Compound 2 manifests single-ion magnet (SIM) behavior with a large effective spin-reversal energy barrier of Ueff = 538 cm-1 in comparison with previously studied (Bu4N+){TbIII(Pc2-)2}- ( Ueff = 230 cm-1). Thus, changes in cation size and shape affect the molecular packing of {TbIII(Pc2-)2}- and increase the spin-reversal energy barrier. At the same time, two-electron-reduced species 3 containing TbIII and Pc•3- show no signs of SIM such as hysteresis loop at 1.9 K, and no peaks are observed on the temperature dependencies of in-phase (χ') and out-of-phase (χ″) signals. In contrast to EPR silent 2, both compounds 1 and 3 manifest broad signals from paramagnetic TbIII ions. Narrower signals attributed to Pc•3- are of high intensity only in 3. In addition to the absorption bands of Pc in the UV and visible spectral range, compound 3 manifests the lowest energy absorption band in solid-state spectra even in the near IR range at 4700 cm-1 (2130 nm), whereas such bands are not observed in the spectrum of 2. These data show that the reduction of the Pc macrocycles in the lanthanide double-deckers leads to the appearance of new very low-energy new transitions associated with Pc•3- whose energy is the lowest among known reduced metal phthalocyanines.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA