Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cytometry A ; 89(11): 1010-1016, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27768824

RESUMO

Whereas commercially available hematological analyzers measure volume of individual platelets, angle-resolved light-scattering provides unique ability to additionally measure their shape index. We utilized the scanning flow cytometer to measure light-scattering profiles (LSPs) of individual platelets taken from 16 healthy donors and the solution of the inverse light-scattering problem to retrieve the volume and shape index of each platelet. In normal conditions, the platelet shape index distribution (PSID) demonstrates three peaks, which relate to resting, partially activated, and fully activated platelets. We developed an algorithm, based on fitting PSID by a sum of three peak functions, to determine the percentage, mean platelet shape index, and distribution width of each platelet fraction. In total, this method gives eight additional parameters of platelet morphology and function to be used in clinical hematological analysis. We also stimulated the platelets with adenosine diphosphate (ADP) and measured the dependence of equilibrium PSID, including the total percentage of activated platelets, on ADP concentration. © 2016 International Society for Advancement of Cytometry.


Assuntos
Algoritmos , Plaquetas/citologia , Citometria de Fluxo/métodos , Humanos
2.
J Immunol Methods ; 418: 66-74, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25687877

RESUMO

Traditional methods for estimating the number of expressed molecules, based on the detection of target antigens bound with fluorescently labeled antibodies, assume that the antigen-antibody reaction reaches equilibrium. A calibration procedure is used to convert the intensity of the fluorescence signal to the number of target molecules. Along with the different limitations of every calibration system, this substantially limits the applicability of the traditional approaches especially in the case of low affinity antibodies. We address this problem here with studies in which we demonstrate a new approach to the antigen molecule quantification problem. Instead of using a static calibration system, we analyzed mean fluorescence values over time by flow cytometry during antibody-antigen binding. Experimental data obtained with an LSRII cytometer were fitted by a diffusion-reaction mathematical model using the Levenberg-Marquardt nonlinear least squares curve-fitting algorithm in order to obtain the number of target antigen molecules per cell. Results were compared with the Quanti-BRITE calibration system. We conclude that, instead of using experiment-specific calibration, the value of the binding rate constant for each particular antibody-antigen reaction can be used to quantify antigen molecules with flow cytometry. The radius of CD8 antibody molecule binding site was found, that allows recalculating the binding rate constant for other conditions (different sizes of reagent molecules, fluorescent label, medium viscosity and temperature). This approach is independent of specially prepared calibration beads, antibody reagents and the specific dye and can be applied to both low and high affinity antibodies, under both saturating and non-saturating binding conditions. The method was demonstrated on a human blood sample dataset investigating CD8α antigen on T cells in stable binding conditions.


Assuntos
Antígenos CD8/análise , Citometria de Fluxo , Anticorpos Monoclonais/imunologia , Reações Antígeno-Anticorpo , Sítios de Ligação de Anticorpos , Antígenos CD8/imunologia , Humanos , Linfócitos T Citotóxicos/imunologia
3.
J Immunol Methods ; 427: 139-47, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27030828

RESUMO

Traditional methods for estimating the number of expressed molecules, based on the detection of target antigens bound with fluorescently labeled antibodies, assume that the antigen-antibody reaction reaches equilibrium. A calibration procedure is used to convert the intensity of the fluorescence signal to the number of target molecules. Along with the different limitations of every calibration system, this substantially limits the applicability of the traditional approaches especially in the case of low affinity antibodies. We address this problem here with studies in which we demonstrate a new approach to the antigen molecule quantification problem. Instead of using a static calibration system, we analyzed mean fluorescence values over time by flow cytometry during antibody-antigen binding. Experimental data obtained with an LSRII cytometer were fitted by a diffusion-reaction mathematical model using the Levenberg-Marquardt nonlinear least squares curve-fitting algorithm in order to obtain the number of target antigen molecules per cell. Results were compared with the Quanti-BRITE calibration system. We conclude that, instead of using experiment-specific calibration, the value of the binding rate constant for each particular antibody-antigen reaction can be used to quantify antigen molecules with flow cytometry. The radius of CD8 antibody molecule binding site was found, that allows recalculating the binding rate constant for other conditions (different sizes of reagent molecules, fluorescent label, medium viscosity and temperature). This approach is independent of specially prepared calibration beads, antibody reagents and the specific dye and can be applied to both low and high affinity antibodies, under both saturating and non-saturating binding conditions. The method was demonstrated on a human blood sample dataset investigating CD8α antigen on T cells in stable binding conditions.


Assuntos
Reações Antígeno-Anticorpo/imunologia , Antígenos/imunologia , Citometria de Fluxo/métodos , Anticorpos Monoclonais/imunologia , Sítios de Ligação de Anticorpos/imunologia , Imunofluorescência , Humanos
5.
Vestn Ross Akad Med Nauk ; (8): 31-5, 2004.
Artigo em Russo | MEDLINE | ID: mdl-15455689

RESUMO

Thirteen murine hybridoma lines producing monoclonal antibodies (Mabs) to recombinant human laminin-binding protein (rLBP) were developed. All 13 Mabs reacted with affinity purified 43 kDA rLBP in ELISA and Western blotting. Mab class determination showed 9 Mabs as belonging to IgM class, 2 Mabs--to IgG2 subclass, 1 Mab--to IgG1 and 1 Mab--to IgG2b. Ten Mabs of different classes were capable to react with LBP on the surface of Vero cells. Mabs displayed a high and simultaneously varying affinity to rLBP (10(8) 10(9) M(-1)). The Mab affinity was found to be comparable with the mean affinity of mouse and rabbit antibodies isolated from hyperimmune sera. The possibility of using the produced Mabs in mapping the LBP domains involved in virus attachment, cell differentiation and cancer metastases progression as well as in the systemic response to bacterial protozoan and parasitic infection is under discussion.


Assuntos
Anticorpos Monoclonais/imunologia , Laminina/imunologia , Laminina/metabolismo , Precursores de Proteínas , Receptores de Laminina , Receptores de Laminina/imunologia , Receptores de Laminina/metabolismo , Animais , Anticorpos Monoclonais/análise , Afinidade de Anticorpos , Western Blotting , Diferenciação Celular , Chlorocebus aethiops , Progressão da Doença , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoquímica , Técnicas Imunoenzimáticas , Imunoglobulina G/análise , Laminina/genética , Camundongos , Camundongos Endogâmicos BALB C , Metástase Neoplásica , Coelhos , Receptores de Laminina/genética , Proteínas Recombinantes , Células Vero
6.
J Theor Biol ; 206(3): 407-17, 2000 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-10988026

RESUMO

A statistical approach is presented to model the kinetics of cell distribution in the process of ligand-receptor binding on cell surfaces. The approach takes into account the variation of the amount of receptors on cells assuming the homogeneity of monovalent binding sites and ligand molecules. The analytical expressions for the kinetics of cell distribution have been derived in the reaction-limited approximation. In order to demonstrate the applicability of the mathematical model, the kinetics of binding the rabbit, anti-mouse IgG with Ig-receptors of the murine hybridoma cells has been measured. Anti-mouse IgG was labeled with fluorescein isothiocyanate (FITC). The kinetics of cell distribution on ligand-receptor complexes was observed during the reaction process by real-time measuring of the fluorescence and light-scattering traces of individual cells with the scanning flow cytometer. The experimental data were fitted by the mathematical model in order to obtain the binding rate constant and the initial cell distribution on the amount of receptors.


Assuntos
Simulação por Computador , Hibridomas/citologia , Hibridomas/metabolismo , Imunoglobulina G/metabolismo , Modelos Estatísticos , Receptores de IgG/metabolismo , Animais , Citometria de Fluxo , Camundongos , Modelos Biológicos , Ligação Proteica , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA