Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cytometry A ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107997

RESUMO

This panel was designed to characterize the immune cell landscape in the mouse tumor microenvironment as well as mouse lymphoid tissues (e.g., spleen). As an example, using the MC-38 mouse syngeneic tumor model, we demonstrated that we could measure the frequency and characterize the functional status of CD4 T cells, CD8 T cells, regulatory T cells, NK cells, B cells, macrophages, granulocytes, monocytes, and dendritic cells. This panel is especially useful for understanding the immune landscape in "cold" preclinical tumor models with very low immune cell infiltration and for investigating how therapeutic treatments may modulate the immune landscape.

2.
Cytometry A ; 101(10): 835-845, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35112484

RESUMO

Recent advances in flow cytometry instrumentation and fluorochrome chemistries have greatly increased fluorescent conjugated antibody combinations that can be used reliably and easily in routine experiments. The Cytek Aurora flow cytometer was first released with three excitation lasers (405, 488, and 640 nm) and incorporated the latest Avalanche Photodiode (APD) technology, demonstrating significant improvement in sensitivity for fluorescent emission signals longer than 800 nm. However, there are limited commercially available fluorochromes capable of excitation with peak emission signals beyond 800 nm. To address this gap, we engineered six new fluorochromes: PE-750, PE-800, PE-830 for the 488 nm laser and APC-750, APC-800, APC-830 for the 640 nm laser. Utilizing the principal of fluorescence resonance energy transfer (FRET), these novel structures were created by covalently linking a protein donor dye with an organic small molecule acceptor dye. Additionally, each of these fluorochrome conjugates were shown to be compatible with fixation/permeabilization buffer reagents, and demonstrated acceptable brightness and stability when conjugated to antigen-specific monoclonal antibodies. These six novel fluorochrome reagents can increase the numbers of fluorochromes that can be used on a spectral flow cytometer.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Corantes Fluorescentes , Anticorpos Monoclonais , Antígenos , Citometria de Fluxo , Imunofluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA