RESUMO
OBJECTIVE: To investigate efficacy between arthroscopic popliteal cyst drainage and arthroscopic popliteal cyst resection. METHODS: From January 2013 to June 2021, 54 patients with popliteal cyst (Rausching-Lindgren gradeâ to â ¢) were treated with arthroscopic surgery. There were 24 males and 30 females. The age ranged from 44 to 72 years old, with a mean of (62.67±6.08) years old. The course of the disease ranged from 1 to 72 months, with a mean of(15±14) months. Twenty-four patients (group A) were underwent arthroscopic internal drainage of popliteal cyst. Thirty patients (group B) were underwent arthroscopic resection of popliteal cyst. Preoperative main symptoms included knee pain, swelling, walking pain, popliteal swelling, popliteal mass and so on. After 1, 3, 6 months and 1, 2 years of surgery, routine outpatient follow-up was conducted to observe and compare the surgical time, bleeding volume, preoperative and postoperative visual analog scale (VAS), knee Lysholm score, and complications between two groups. RESULTS: All incisions healed at one stage after operation. All 54 patients were followed up, and the duration ranged from 6 months to 2 years, with an average of (13.89±4.29) months. There was no intraoperative vascular or nerve injury. Operation time and intraoperative blood loss of the two groups:group A of (62.08±9.55) min and (8.00±1.69) ml, group B of (69.50±6.99) min and (8.70±2.00) ml. Popliteal pain, swelling, limitation of flexion and extension were significantly relieved after operation. VAS before and one month after operation between two groups:group A of 5.38±1.21 and 2.63±0.71, group B of 5.60±1.26 and 2.80±0.81. Lysholm scores of knee joint before and 6 months after operation:group A of 62.59±4.99 and 89.74±2.90, group B of 63.87±3.23 and 89.02±2.35. Knee joint function improved significantly in both groups. In group A, 4 cases had popliteal cyst at 3 months after operation, and 2 cases had small isolated cyst at 1 year after operation. There was no recurrence of cyst in group B. CONCLUSION: The results between two arthroscopic treatments of popliteal cyst are satisfactory, and there is no significant difference in the amount of blood loss, safety, postoperative pain VAS score and knee function recovery. It is suggested that arthroscopic resection of the cyst wall should be performed when the technique is mature, especially for large cysts and septal cysts.
Assuntos
Cistos , Cisto Popliteal , Feminino , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Cisto Popliteal/cirurgia , Drenagem , Articulação do Joelho/cirurgia , DorRESUMO
OBJECTIVE: To explore clinical effect of lateral locking compression plate combined with medial buttress plate in treating osteoporotic comminuted fractures of proximal humerus. METHODS: From May 2017 to December 2021, 12 patients with osteoporotic comminution of proximal humerus were treated by lateral locking compression plates combined with medial buttress plates, including 5 males and 7 females, aged from 55 to 78 years old, bone mineral density(BMD) less than -2.5 g/cm3, the time from injury to operation was from 2 to 6 days. According to Neer classification, 7 patients were type â ¢, 4 patients were type â £ and 1 patient was type â ¥. Postoperative complications, fracture healing and internal fixation were observed and Constant-Murley score of shoulder joint was used to evaluate clinical effects at 6 months after operation. RESULTS: Postoperative wound healed well at stage I. All patients were followed up from 6 to 18 months. Humeral head collapse and necrosis occurred in 1 patient and humeral head varus in 1 patient. No impact of shoulder joint, internal fixation loosening occurred. Constant-Murley score at 6 months ranged from 45 to 90 points, and 6 patients got excellent result, 3 good, and 3 poor. CONCLUSION: Locking compression plate combined with medial buttress plate could effectively reconstruct medial humeral column support and enhance fracture stability, and receive satisfactory clinical results. However, no control group was established in this study, and function of shoulder joint has not been evaluated many times after operation, so it cannot dynamically reflect changes of shoulder joint function.
Assuntos
Placas Ósseas , Fraturas Cominutivas , Fraturas do Úmero , Fraturas por Osteoporose , Fraturas do Ombro , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Placas Ósseas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas do Úmero/complicações , Cabeça do Úmero , Úmero , Fraturas do Ombro/cirurgia , Resultado do Tratamento , Fraturas por Osteoporose/cirurgiaRESUMO
OBJECTIVE: To observe the clinical effect of the treatment for complex fractures of the tibial plateau through the application of the external fixator and the locking plate. METHODS: From Feb. 2006 to Oct. 2008,12 patients with tibial plateau fractures were treated with external fixator and locking plate included 8 males and 4 females with an average age of 38 years ranging from 23 to 59. According to Schatzker type, 7 cases were type V and 5 cases were type VI. Using an anteromedial incision and an anterolateral approach, the locking plate were fixed in the tibia lateral. The collapse and height lossing of tibial plateau was observed through X-ray film before and after operation. The function of knee joint was evaluated according to HSS scoring. RESULTS: These patients were followed up for 4 to 18 months (means 9.79 months). Eleven cases had bone primary union,and 1 delayed union. No deep phlebothrombosis and osteofascial compartment syndrome occurened. The average healing time was 3.1 months. Between the preoperative and postoperative X-ray film there were no second stage depression fracture of the tibial plateau,postoperative reduction loss and bad alignment. The range of knee flexion was 90 degrees to 110 degrees. The HSS knee functional scoring was(75.50 +/- 10.01)scores after operation and (21.50 +/- 11.68) scores before operation. CONCLUSION: The treatment with the external fixator and the locking plate for complex fractures of the tibial plateau could provid continuous stability of fixation,prevent the fracture from second stage displacement and the knee force line change, protect the soft-tissue around the knee, reduce the postoperative complications. The knee joint function is satisfied.