Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 12(2): 182-193, 2019 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-30678797

RESUMO

OBJECTIVES: The aim of this study was to evaluate the predictors of left ventricular outflow tract (LVOT) obstruction after transcatheter mitral valve replacement (TMVR). BACKGROUND: LVOT obstruction is a major concern with TMVR, but limited data exist regarding its predictors and impact on outcomes. METHODS: Patients with pre-procedural multidetector row computed tomography (MDCT) undergoing TMVR for failed mitral bioprosthetic valves (valve-in-valve), annuloplasty rings (valve-in-ring), and mitral annular calcification (valve-in-MAC) were included in this study. Echocardiographic and procedural characteristics were recorded, and comprehensive assessment with MDCT was performed to identify the predictors of LVOT obstruction (defined as an increment of mean LVOT gradient ≥10 mm Hg from baseline). The new LVOT (neo-LVOT) area left after TMVR was estimated by embedding a virtual valve into the mitral annulus on MDCT, simulating the procedure. RESULTS: Among 194 patients with pre-procedural MDCT undergoing TMVR (valve-in-valve, 107 patients; valve-in-ring, 50 patients; valve-in-MAC, 37 patients), LVOT obstruction was observed in 26 patients (13.4%), with a higher rate after valve-in-MAC than valve-in-ring and valve-in-valve (54.1% vs. 8.0% vs. 1.9%; p < 0.001). Patients with LVOT obstruction had significantly higher procedural mortality compared with those without LVOT obstruction (34.6% vs. 2.4%; p < 0.001). Receiver-operating characteristic curve analysis showed that an estimated neo-LVOT area ≤1.7 cm2 predicted LVOT obstruction with sensitivity of 96.2% and specificity of 92.3%. CONCLUSIONS: LVOT obstruction after TMVR was associated with higher procedural mortality. A small estimated neo-LVOT area was significantly associated with LVOT obstruction after TMVR and may help identify patients at high risk for LVOT obstruction.


Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/etiologia , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Estenose da Valva Mitral/fisiopatologia , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/mortalidade , Obstrução do Fluxo Ventricular Externo/fisiopatologia
2.
Rev Bras Cir Cardiovasc ; 29(2): 285-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25140481

RESUMO

Insertion of inferior vena cava filters has been well established in literature, reducing occurrence of pulmonary embolism after an episode of deep venous thrombosis in patients with contraindication to anticoagulation. There are a small number of complications related to procedure and embolization is rare. In this context, we described a case of intracardiac embolization associated with cardiac tamponade.


Assuntos
Tamponamento Cardíaco/etiologia , Traumatismos Cardíacos/etiologia , Embolia Pulmonar/etiologia , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior , Angiografia Coronária , Átrios do Coração/lesões , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X , Trombose Venosa/etiologia
3.
Rev. bras. cir. cardiovasc ; 29(2): 285-288, Apr-Jun/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-719421

RESUMO

Insertion of inferior vena cava filters has been well established in literature, reducing occurrence of pulmonary embolism after an episode of deep venous thrombosis in patients with contraindication to anticoagulation. There are a small number of complications related to procedure and embolization is rare. In this context, we described a case of intracardiac embolization associated with cardiac tamponade.


A colocação percutânea de filtro de veia cava inferior é bem estabelecida em literatura, reduzindo a chance de ocorrência de tromboembolismo pulmonar após um episódio de trombose venosa profunda em pacientes com contraindicações à anticoagulação. O índice de complicações relacionadas ao procedimento é pequeno, sendo embolização evento extremamente raro. Nesse contexto, descrevemos um caso de embolização intracardíaca de filtro de veia cava inferior associada ao tamponamento cardíaco.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Tamponamento Cardíaco/etiologia , Traumatismos Cardíacos/etiologia , Embolia Pulmonar/etiologia , Veia Cava Inferior , Filtros de Veia Cava/efeitos adversos , Angiografia Coronária , Átrios do Coração/lesões , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X , Trombose Venosa/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA