Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Fr Ophtalmol ; 44(8): 1229-1236, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34243998

RESUMO

PURPOSE: To examine the reproducibility of spectral domain optical coherence tomography (SD-OCT) segmented ganglion cell complex and circumpapillary retinal nerve fiber layer (cpRNFL) measurements in children with primary congenital glaucoma (PCG) in comparison with healthy children. METHODS: 12 children with PCG (G1) and 24 healthy children (G2) were recruited. The following SD-OCT measurements (Spectralis, Heidelberg Engineering) were made in one eye per child: total macular thickness (MT), thicknesses in several subfields and volumes of the three inner macular layers, macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL) and cpRNFL thickness. In a single day, an expert operator obtained 3 circumpapillary and 3 macular measurements in each participant to determine intraoperator variability. Intraoperator repeatability was defined by the coefficient of variation (CoV) and intraclass correlation (ICC). RESULTS: ICC was excellent in both groups for cpRNFL measurements (G1 ICC=0.950 and G2 ICC=0.995) and for MT was excellent in G1 (ICC=0.957) and moderate in G2 (ICC=552). For the inner macular layer measurements, all ICCs were better in PCG group (mRNFL-ICC: 0.915 vs. 0.765; ICC-GCL: 0.584 vs. 0.263 and ICC-IPL: 0.979 vs. 0.742; G1 and G2 respectively). Greater CoV were recorded for macular measurements (from 0.71% to 9.82%) compared to cpRNFL measurements (from 0.52% to 1.50%). CONCLUSION: In children with PCG, Spectralis SD-OCT showed excellent intrasession repeatability for cpRNFL, MT, mRNFL and IPL measurements and moderated for GCL measurements. For all macular measurements, ICC were higher in children with PCG than healthy children.


Assuntos
Glaucoma , Macula Lutea , Criança , Estudos Transversais , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Reprodutibilidade dos Testes , Células Ganglionares da Retina , Tomografia de Coerência Óptica
3.
Arch Soc Esp Oftalmol (Engl Ed) ; 96(3): 127-132, 2021 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33032838

RESUMO

OBJECTIVE: To determine the reliability and validity of VOG Perea® (VP) and GazeLab® (GL), their correlation and concordance with cover test (CT), and define the margins of variability of the measurement of angle deviation in primary position. METHODS: Forty-four orthotropic patients were included. Alternating prism CT, an examination with VP, and GL were performed. Intraclass correlation coefficient (ICC) was calculated to determine the reliability, and mean comparison was used to study validity. Correlation coefficient (R) between CT and each video-oculographer was calculated. Bland-Altman diagrams were used to determine concordance. All measurements were expressed in prismatic dioptres (PD). RESULTS: The mean horizontal deviation was -0.571 PD with CT; 0.22 PD with VP and 0.4 PD with GL. ICC was 0.246 (95% CI: [-0.402]-0.595) in GL and 0.984 [95% CI: 0.970-0.992)] in VP. Mean comparison between CT and GL was -0.9286 (CI 95%: [-1.822]-[0.0355], P=.042) and -0.8423 (95% CI: [-1.7190]-0.03450, P=.0593) for CT-VP. Correlation coefficient for VP was R=0.5704 (95% CI: 0.319-0.747, P=.0001) and R=0.4539 (95% CI: 0.174-0.666, P=.0025) for GL. Margins of variability for a single horizontal measurement in primary position with VP were±5.22 PD and±2 DP for GL. CONCLUSION: Both VP and GL are reliable and valid devices. Margins of variability for a horizontal measurement are ±5.22 PD in VP and±2 PD in GL.

4.
J Fr Ophtalmol ; 43(8): 697-703, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32792292

RESUMO

OBJECTIVE: To compare corneal densitometry and topography variables in patients with primary congenital glaucoma (PCG) and healthy subjects. MATERIAL AND METHODS: Cross sectional study, consecutive recruitment with gender- and age-matched control group. Forty eyes of 40 patients in each group were studied with Pentacam corneal topography. The variables compared between the two groups were: intraocular pressure (IOP), visual acuity (VA) and Pentacam (Oculus, Wetzlar, Germany) corneal topography measurements: mean and maximum keratometry (Km, Kmax), cylinder (Cyl), anterior elevation apex (AEA), central anterior elevation (CAE), maximum anterior elevation (MAE), posterior elevation apex (PEA), central posterior elevation (CPE), maximum posterior elevation (MPE), pachymetry and anterior, mid-stromal and posterior corneal densitometry in the 0-2mm, 2-6mm, 6-10mm zones. RESULTS: Significant differences between patients and healthy controls were detected in the topographic variables MAE (P=0.002) and MPE (P<0.001), and in all the densitometry variables (anterior, mid-stromal, posterior for the 0-2mm, 2-6mm and 6-10mm zones) (P<0.001 each). In the PCG group, negative correlation was observed between VA and total densitometry (r=-0.49; P=0.004). CONCLUSION: Patients with PCG and healthy subjects display differences in corneal densitometry and topographic measurements. PCG patients show greater corneal density with an inverse relationship between visual acuity and higher elevation (anterior and posterior values).


Assuntos
Córnea/diagnóstico por imagem , Glaucoma/congênito , Glaucoma/diagnóstico , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Córnea/patologia , Topografia da Córnea , Estudos Transversais , Densitometria , Feminino , Glaucoma/patologia , Humanos , Lactente , Recém-Nascido , Masculino , Tamanho do Órgão , Prognóstico , Adulto Jovem
5.
Arch Soc Esp Oftalmol (Engl Ed) ; 94(11): 536-539, 2019 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31455595

RESUMO

PURPOSE: To analyse the association between the thickness of the circumpapillary retinal nerve fibre layer (cpRNFL) and the thickness of the inner macular layers with the mean deviation of the visual field (MD) in children with primary congenital glaucoma (PCG). MATERIAL AND METHODS: A total of 41 children with PGC were included in the study. They all had a complete ophthalmological examination, including visual acuity, intraocular pressure, funduscopy, Octopus™ visual field, as well as circumpapillar and macular spectral domain optical coherence tomography (SD-OCT). SD-OCT with automated segmentation was used to measure the thicknesses and volumes of the macular retinal nerve fibre layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer. RESULTS: The mean age was 11.2±3.86 years, and the mean MD was 8.85±6.76dB. The visual field was classified as normal in 46% of the patients, and 20% of the patients had a concentrical restriction of the visual field. A positive correlation was found between between the cup-to-disc ratio and the MD, r=0.51 (P=.004). The correlation between the MD and the cpRNFL was r=-0.63 (P<.001), and r=-0.69 (P<.001) with the GCL. CONCLUSIONS: Inner macular layers thickness and cpRNFL thickness show a good correlation with the mean deviation of the visual field in children with primary congenital glaucoma.


Assuntos
Glaucoma/congênito , Retina/patologia , Campos Visuais , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Fundo de Olho , Humanos , Pressão Intraocular , Macula Lutea/diagnóstico por imagem , Macula Lutea/patologia , Retina/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Adulto Jovem
7.
Arch Soc Esp Oftalmol ; 92(12): 571-576, 2017 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28734565

RESUMO

OBJECTIVE: To evaluate the effect of treatment with topical brinzolamide on visual acuity and nystagmus intensity in patients with congenital nystagmus. MATERIAL AND METHODS: A retrospective study was designed in which the clinical records of 14 patients with congenital nystagmus were reviewed. All patients underwent a complete ophthalmological examination and a Perea video-oculography (VOG) before, and three days after, initiation of treatment with topical brinzolamide (Azopt). Five expert researchers evaluated the intensity of nystagmus by video before and after treatment. Finally, the subjective improvement of the patients was recorded. RESULTS: Statistically significant differences were found in pre- and post-treatment binocular near visual acuity. A slight increase in the frequency of nystagmus was found, which was statistically significant with the horizontal gaze to the left and with the gaze downwards (P=.04, P=.03, respectively). The kappa index concordance between the researchers evaluating the intensity of nystagmus was 0.014. Only two of the patients noticed improvement in visual acuity, and one patient noticed improvement in the aesthetic aspect. CONCLUSIONS: In spite of an improvement in nystagmus, it was slight, not cosmetically appreciable by patients in most cases, and was not related to a significant improvement in visual acuity or in patient quality of life. Further studies are needed to evaluate the effects of topical brinzolamide, and to establish potential therapeutic indications in nystagmus.


Assuntos
Inibidores da Anidrase Carbônica/administração & dosagem , Nistagmo Congênito/tratamento farmacológico , Sulfonamidas/administração & dosagem , Tiazinas/administração & dosagem , Administração Tópica , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Nistagmo Congênito/fisiopatologia , Estudos Retrospectivos , Acuidade Visual/efeitos dos fármacos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA