Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
J Mech Behav Biomed Mater ; 151: 106366, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38176198

RESUMO

Iodine-containing coatings were prepared on pure Ti surfaces via electrochemical deposition to enhance their antibacterial properties. The factors influencing iodine content were analyzed using an orthogonal experiment. The electrochemically deposited samples were characterized using scanning electron microscopy with energy dispersive spectroscopy and X-ray photoelectron spectroscopy, and their antibacterial properties and cytotoxicity were evaluated. The results showed that changing the deposition time is an effective way to control the iodine content. The iodine content, coating thickness, and adhesion of the samples increased with deposition time. Iodine in the coatings mainly exists in three forms, which are I2, I3-, and pentavalent iodine. For samples with iodine-containing coatings, the antibacterial ratios against E. coli and S. aureus were greater than 90% and increased with increasing iodine content. Although the samples with iodine-containing coatings showed some inhibition of the proliferation of MC3T3-E1 cells, the cell viabilities were all higher than 80%, suggesting that iodine-containing coatings are biosafe.


Assuntos
Materiais Revestidos Biocompatíveis , Iodo , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química , Iodo/farmacologia , Staphylococcus aureus , Escherichia coli , Titânio/farmacologia , Antibacterianos/farmacologia , Propriedades de Superfície
2.
Materials (Basel) ; 14(21)2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34772123

RESUMO

We found that specific biomedical Ti and its alloys, such as CP Ti, Ti-29Nb-13Ta-4.6Zr, and Ti-36Nb-2Ta-3Zr-0.3O, form a bright white oxide layer after a particular oxidation heat treatment. In this paper, the interfacial microstructure of the oxide layer on Ti-29Nb-13Ta-4.6Zr and the exfoliation resistance of commercially pure (CP) Ti, Ti-29Nb-13Ta-4.6Zr, and Ti-36Nb-2Ta-3Zr-0.3O were investigated. The alloys investigated were oxidized at 1273 or 1323 K for 0.3-3.6 ks in an air furnace. The exfoliation stress of the oxide layer was high in Ti-29Nb-13Ta-4.6Zr and Ti-36Nb-2Ta-3Zr-0.3O, and the maximum exfoliation stress was as high as 70 MPa, which is almost the same as the stress exhibited by epoxy adhesives, whereas the exfoliation stress of the oxide layer on CP Ti was less than 7 MPa, regardless of duration time. The nanoindentation hardness and frictional coefficients of the oxide layer on Ti-29Nb-13Ta-4.6Zr suggested that the oxide layer was hard and robust enough for artificial tooth coating. The cross-sectional transmission electron microscopic observations of the microstructure of oxidized Ti-29Nb-13Ta-4.6Zr revealed that a continuous oxide layer formed on the surface of the alloys. The Au marker method revealed that both in- and out-diffusion occur during oxidation in Ti-29Nb-13Ta-4.6Zr and Ti-36Nb-2Ta-3Zr-0.3O, whereas only out-diffusion governs oxidation in CP Ti. The obtained results indicate that the high exfoliation resistance of the oxide layer on Ti-29Nb-13Ta-4.6Zr and Ti-36Nb-2Ta-3Zr-0.3O are attributed to their dense microstructures composing of fine particles, and a composition-graded interfacial microstructure. On the basis of the results of our microstructural observations, the oxide formation mechanism of the Ti-Nb-Ta-Zr alloy is discussed.

3.
J Biomed Mater Res A ; 107(5): 944-954, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30861312

RESUMO

In the present article, the recent trends in the research and development of metallic biomaterials are discussed with focus on the results obtained by the author's group. The design of biocompatible metallic biomaterials possessing excellent biological and mechanical properties, including titanium alloys with low Young's modulus, is reviewed with focus on Young's modulus, fatigue strength, and peculiar behavior. The evaluation of biological compatibility including cell viability and living tissue compatibility using animal models and surface modifications using bioactive ceramic and blood-compatible polymers are summarized. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 944-954, 2019.


Assuntos
Materiais Biocompatíveis/farmacologia , Teste de Materiais , Fenômenos Mecânicos , Metais/farmacologia , Animais , Módulo de Elasticidade , Humanos , Propriedades de Superfície
4.
ACS Appl Mater Interfaces ; 10(27): 22997-23008, 2018 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-29664283

RESUMO

Poor kinetics of hole transportation at the electrode/electrolyte interface is regarded as a primary cause for the mediocre performance of n-type TiO2 photoelectrodes. By adopting nanotubes as the electrode backbone, light absorption and carrier collection can be spatially decoupled, allowing n-type TiO2, with its short hole diffusion length, to maximize the use of the available photoexcited charge carriers during operation in photoelectrochemical (PEC) water splitting. Here, we presented a delicate electrochemical anodization process for the preparation of quaternary Ti-Nb-Ta-Zr-O mixed-oxide (denoted as TNTZO) nanotube arrays and demonstrated their utility in PEC water splitting. The charge-transfer dynamics for the electrodes was investigated using time-resolved photoluminescence, electrochemical impedance spectroscopy, and the decay of open-circuit voltage analysis. Data reveal that the superior photoactivity of TNTZO over pristine TiO2 originated from the introduction of Nd, Ta, and Zr elements, which enhanced the amount of accessible charge carriers, modified the electronic structure, and improved the hole injection kinetics for expediting water splitting. By modulating the water content of the electrolyte employed in the anodization process, the wall thickness of the grown TNTZO nanotubes can be reduced to a size smaller than that of the depletion layer thickness, realizing a fully depleted state for charge carriers to further advance the PEC performance. Hydrogen evolution tests demonstrate the practical efficacy of TNTZO for realizing solar hydrogen production. Furthermore, with the composition complexity and fully depleted band structure, the present TNTZO nanotube arrays may offer a feasible and universal platform for the loading of other semiconductors to construct a sophisticated heterostructure photoelectrode paradigm, in which the photoexcited charge carriers can be entirely utilized for efficient solar-to-fuel conversion.

5.
PLoS One ; 13(1): e0189967, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29342150

RESUMO

Simulated Body Fluid (SBF) has served as a useful standard to check the bioactivity of implant materials for years. However, it is not perfectly able to imitate human serum; sometimes disparities between the SBF test and animal test were confirmed. Therefore, to ensure the reliability of the results of the SBF test obtained from our previous study, an animal study was performed to check osteoconductivity of surface modified implant materials. Three types of solution processes, hydrothermal (H), electrochemical (E), and hydrothermal-electrochemical (HE), were performed on the Ti-29Nb-13Ta-4.6Zr alloy (TNTZ) to improve its bioactivity, and their bioactivities were measured in vivo using bone-implant contacts (BICs). BICs of the HE- and H-treated samples were significantly higher than that of the control. Metal ion diffusion towards the bone was also evaluated to examine the adverse effect of metal ions. No metal ion diffusion was observed, indicating the safety of our solution processed implant materials.


Assuntos
Regeneração Óssea , Nióbio/química , Tantálio/química , Titânio/química , Oligoelementos/farmacocinética , Zircônio/química , Animais , Ratos , Ratos Sprague-Dawley , Solubilidade
7.
Sci Rep ; 6: 29779, 2016 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-27417073

RESUMO

ß-type Ti-29Nb-13Ta-4.6Zr alloy is a promising novel material for biomedical applications. We have proposed a 'single crystalline ß-Ti implant' as new hard tissue replacements for suppressing the stress shielding by achieving a drastic reduction in the Young's modulus. To develop this, the orientation dependence of the plastic deformation behavior of the Ti-29Nb-13Ta-4.6Zr single crystal was first clarified. Dislocation slip with a Burgers vector parallel to <111> was the predominant deformation mode in the wide loading orientation. The orientation dependence of the yield stress due to <111> dislocations was small, in contrast to other ß-Ti alloys. In addition, {332} twin was found to be operative at the loading orientation around [001]. The asymmetric features of the {332} twin formation depending on the loading orientation could be roughly anticipated by their Schmid factors. However, the critical resolved shear stress for the {332} twins appeared to show orientation dependence. The simultaneous operation of <111> slip and {332} twin were found to be the origin of the good mechanical properties with excellent strength and ductility. It was clarified that the Ti-29Nb-13Ta-4.6Zr alloy single crystal shows the "plastically almost-isotropic and elastically highly-anisotropic" nature, that is desirable for the development of 'single crystalline ß-Ti implant'.

8.
Regen Biomater ; 3(3): 173-85, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27252887

RESUMO

Biomedical titanium alloys with Young's moduli close to that of cortical bone, i.e., low Young's modulus titanium alloys, are receiving extensive attentions because of their potential in preventing stress shielding, which usually leads to bone resorption and poor bone remodeling, when implants made of their alloys are used. They are generally ß-type titanium alloys composed of non-toxic and allergy-free elements such as Ti-29Nb-13Ta-4.6Zr referred to as TNTZ, which is highly expected to be used as a biomaterial for implants replacing failed hard tissue. Furthermore, to satisfy the demands from both patients and surgeons, i.e., a low Young's modulus of the whole implant and a high Young's modulus of the deformed part of implant, titanium alloys with changeable Young's modulus, which are also ß-type titanium alloys, for instance Ti-12Cr, have been developed. In this review article, by focusing on TNTZ and Ti-12Cr, the biological and mechanical properties of the titanium alloys with low Young's modulus and changeable Young's modulus are described. In addition, the titanium alloys with shape memory and superelastic properties were briefly addressed. Surface modifications for tailoring the biological and anti-wear/corrosion performances of the alloys have also been briefly introduced.

9.
Adv Healthc Mater ; 5(14): 1740-52, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27113724

RESUMO

Osteoporosis is becoming more prevalent due to the aging demographics of many populations. Osteoporotic bone is more prone to fracture than normal bone, and current orthopedic implant materials are not ideal for the osteoporotic cases. A newly developed strontium phosphate (SrPO4 ) coating is reported herein, and applied to Ti-29Nb-13Ta-4.6Zr (wt%), TNTZ, an implant material with a comparative Young's modulus to that of natural bone. The SrPO4 coating is anticipated to modulate the activity of osteoblast (OB) and osteoclast (OC) cells, in order to promote bone formation. TNTZ, a material with excellent biocompatibility and high bioinertness is pretreated in a concentrated alkaline solution under hydrothermal conditions, followed by a hydrothermal coating growth process to achieve complete SrPO4 surface coverage with high bonding strength. Owing to the release of Sr ions from the SrPO4 coating and its unique surface topography, OB cells demonstrate increased proliferation and differentiation, while the cellular responses of OC are suppressed, compared to the control case, i.e., bare TNTZ. This TNTZ implant with a near physiologic Young's modulus and a functional SrPO4 coating provides a new direction in the design and manufacture of implantable devices used in the management of orthopedic conditions in osteoporotic individuals.


Assuntos
Ligas/química , Substitutos Ósseos/química , Materiais Revestidos Biocompatíveis/química , Teste de Materiais , Osteoblastos/metabolismo , Fosfatos/química , Estrôncio/química , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Osteoblastos/citologia
10.
J Mech Behav Biomed Mater ; 59: 497-507, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26999621

RESUMO

Titanium and its alloys are suitable for biomedical applications owing to their good mechanical properties and biocompatibility. Beta-type Ti-Mn alloys (8-17 mass% Mn) were fabricated by metal injection molding (MIM) as a potential low cost material for use in biomedical applications. The microstructures and mechanical properties of the alloys were evaluated. For up to 13 mass% Mn, the tensile strength (1162-938MPa) and hardness (308-294HV) of the MIM fabricated alloys are comparable to those of Ti-Mn alloys fabricated by cold crucible levitation melting. Ti-9Mn exhibits the best balance of ultimate tensile strength (1046MPa) and elongation (4.7%) among the tested alloys, and has a Young's modulus of 89GPa. The observed low elongation of the alloys is attributed to the combined effects of high oxygen content, with the presence of interconnected pores and titanium carbides, the formation of which is due to carbon pickup during the debinding process. The elongation and tensile strength of the alloys decrease with increasing Mn content. The Ti-Mn alloys show good compressive properties, with Ti-17Mn showing a compressive 0.2% proof stress of 1034MPa, and a compressive strain of 50%.


Assuntos
Manganês , Teste de Materiais , Desenho de Prótese , Titânio , Ligas , Força Compressiva , Módulo de Elasticidade , Dureza , Resistência à Tração
11.
J Mech Behav Biomed Mater ; 59: 226-235, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26774617

RESUMO

The effects of severe plastic deformation through high-pressure torsion (HPT) on the microstructure and tensile properties of a biomedical Co-Cr-Mo (CCM) alloy were investigated. The microstructure was examined as a function of torsional rotation number, N and equivalent strain, εeq in the HPT processing. Electron backscatter diffraction analysis (EBSD) shows that a strain-induced martensitic transformation occurs by the HPT processing. Grain diameter decreases with increasing εeq, and the HPT-processed alloy (CCMHPT) for εeq=45 exhibits an average grain diameter of 47nm, compared to 70µm for the CCM alloy before HPT processing. Blurred and wavy grain boundaries with low-angle of misorientation in the CCMHPT sample for εeq<45 become better-defined grain boundaries with high-angle of misorientation after HPT processing for εeq=45. Kernel average misorientation (KAM) maps from EBSD indicate that KAM inside grains increases with εeq for εeq<45, and then decreases for εeq=45. The volume fraction of the ε (hcp) phase in the CCMHPT samples slightly increases at εeq=9, and decreases at εeq=45. In addition, the strength of the CCMHPT samples increases at εeq=9, and then decrease at εeq=45. The decrease in the strength is attributed to the decrease in the volume fraction of ε phase, annihilation of dislocations, and decrease in strain in the CCMHPT sample processed at εeq=45 by HPT.


Assuntos
Ligas/química , Cromo , Cobalto , Teste de Materiais , Fenômenos Mecânicos , Molibdênio , Pressão , Torque
12.
Acta Biomater ; 26: 366-76, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26283166

RESUMO

The microstructures, mechanical properties and biocompatibility of low cost ß-type Ti-(6-18)Mn alloys were investigated after solution treatment. Ti-9 Mn exhibits the best combination of tensile strength and elongation among the fabricated alloys, and its performance is comparable to or superior to those of Ti-6Al-4V ELI (Ti-64 ELI) in terms of every parameter evaluated. A hardness of 338 HV, a Young's modulus of 94 GPa, a 0.2% proof stress of 1023 MPa, an ultimate tensile strength of 1048 MPa and elongation of 19% were obtained for Ti-9 Mn. Furthermore, the cell viability and metallic ion release ratios are comparable to those of commercially pure titanium, making this alloy promising for biomedical applications. The Young's modulus is also lower than that of Ti-64 ELI (110 GPa), which can possibly reduce the stress shielding effect in implanted patients. STATEMENT OF SIGNIFICANCE: This study evaluates mechanical and biological performance of low cost solution treated ß-type Ti-(6, 9, 13 and 18 mass%)Mn alloys. It includes alloys containing a Mn content range higher than most previously published works (which is around or lower than 8 mass%). Furthermore, the effects of the ω phase and the ß phase stability of the alloys over some mechanical properties and microstructures are discussed. Ion release behavior under simulated body fluids and cell viability are also evaluated. For the case of the Ti-9 Mn, a mechanical and biological performance that is comparable to or superior than that of the widely used Ti-6Al-4V ELI and commercially pure Ti was observed.


Assuntos
Apoptose/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Manganês/química , Manganês/toxicidade , Titânio/química , Titânio/toxicidade , Células 3T3 , Ligas/química , Ligas/toxicidade , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Força Compressiva , Módulo de Elasticidade , Dureza , Teste de Materiais , Camundongos , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
13.
J Mech Behav Biomed Mater ; 51: 398-408, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26301568

RESUMO

In previous studies, it has been concluded that volume losses (V loss) of the Ti-29Nb-13Ta-4.6Zr (TNTZ) discs and balls are larger than those of the respective Ti-6Al-4V extra-low interstitial (Ti64) discs and balls, both in air and Ringer's solution. These results are related to severe subsurface deformation of TNTZ, which is caused by the lower resistance to plastic shearing of TNTZ than that of Ti64. Therefore, it is necessary to further increase the wear resistance of TNTZ to satisfy the requirements as a biomedical implant. From this viewpoint, interstitial oxygen was added to TNTZ to improve the plastic shear resistance via solid-solution strengthening. Thus, the wear behaviors of combinations comprised of a new titanium alloy, TNTZ with high oxygen content of 0.89 mass% (89O) and a conventional titanium alloy, Ti64 were investigated in air and Ringer's solution for biomedical implant applications. The worn surfaces, wear debris, and subsurface damage were analyzed using a scanning electron microscopy and an electron probe microanalysis. V loss of the 89O discs and balls are smaller than those of the respective TNTZ discs and balls in both air and Ringer's solution. It can be concluded that the solid-solution strengthening by oxygen effectively improves the wear resistance for TNTZ materials. However, the 89O disc/ball combination still exhibits higher V loss than the Ti64 disc/ball combination in both air and Ringer's solution. Moreover, V loss of the disc for the 89O disc/Ti64 ball combination significantly decreases in Ringer's solution compared to that in air. This decrease for the 89O disc/Ti64 ball combination in Ringer's solution can be explained by the transition in the wear mechanism from severe delamination wear to abrasive wear.


Assuntos
Materiais Biocompatíveis/química , Fenômenos Mecânicos , Nióbio/química , Oxigênio/química , Tantálio/química , Titânio/química , Zircônio/química , Fricção , Teste de Materiais , Peso Molecular , Soluções , Propriedades de Superfície
14.
Acta Biomater ; 24: 361-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26102334

RESUMO

Along with a high strength, ductility, and work hardening rate, a variable Young's modulus is crucial for materials used as implant rods in spinal fixation surgery. The potential in this context of Ti-(9,8,7)Cr-0.2O (mass%) alloys is reported herein. The microstructural and mechanical properties of the alloys were systematically examined as a function of their chromium content, and the ion release of the optimized alloy was investigated to assess its suitability as an implant material. In terms of the deformation-induced ω-phase transformation required for a variable Young's modulus, the balance between ß-phase stability and athermal ω-phase content is most favorable in the Ti-9Cr-0.2O alloy. In addition, this composition affords a high tensile strength (>1000MPa), elongation at break (∼20%), and work hardening rate to solution-treated (ST) samples. These excellent properties are attributed to the combined effects of deformation-induced ω-phase transformation, deformation twinning, and dislocation gliding. Furthermore, the ST Ti-9Cr-0.2O alloy proves resistant to metal ion release in simulated body fluid. This combination of a good biocompatibility, variable Young's modulus and a high strength, ductility, and work hardening rate is ideal for spinal fixation applications. STATEMENT OF SIGNIFICANCE: Extensive efforts have been devoted over the past decades to developing ß-type titanium alloys with low Young's moduli for biomedical applications. In spinal fixation surgery however, along with excellent mechanical properties, the spinal-support materials should possess high Young's modulus for showing small springback during surgery to facilitate manipulation but low Young's modulus close to bone once implanted to avoid stress shielding. None of currently used metallic biomaterials can satisfy these abovementioned requirements. In the present study, we have developed a novel alloy, Ti-9Cr-0.2O. Remarkably variable Young's modulus and excellent mechanical properties can be achieved in this alloy via phase transformations and complex deformation mechanisms, which makes the Ti-9Cr-0.2O preferred material for spinal fixation surgery.


Assuntos
Ligas de Cromo/química , Módulo de Elasticidade , Fixadores Internos , Coluna Vertebral , Titânio/química , Humanos
15.
Artigo em Inglês | MEDLINE | ID: mdl-26046260

RESUMO

Ti-xMg (x=17, 33, and 55 mass%) alloy films, which cannot be prepared by conventional melting processes owing to the absence of a solid-solution phase in the phase diagram, were prepared by direct current magnetron sputtering in order to investigate their biocompatibility. Ti and Mg films were also prepared by the same process for comparison. The crystal structures were examined by X-ray diffraction (XRD) analysis and the surfaces were analyzed by X-ray photoelectron spectroscopy. The Ti, Ti-xMg alloy, and Mg films were immersed in a 0.9% NaCl solution at 310 K for 7d to evaluate the dissolution amounts of Ti and Mg. In addition, to evaluate the formation ability of calcium phosphate in vitro, the Ti, Ti-xMg alloy, and Mg films were immersed in Hanks' solution at 310 K for 30 d. Ti and Mg form solid-solution alloys because the peaks attributed to pure Ti and Mg do not appear in the XRD patterns of any of the Ti-xMg alloy films. The surfaces of the Ti-17 Mg alloy and Ti-33 Mg alloy films contain Ti oxides and MgO, whereas MgO is the main component of the surface oxide of the Ti-55 Mg alloy and Mg films. The dissolution amounts of Ti from all films are below or near the detection limit of inductively coupled plasma-optical emission spectroscopy. On the other hand, the Ti-17 Mg alloy, Ti-33 Mg alloy, Ti-55 Mg alloy, and Mg films exhibit Mg dissolution amounts of approximately 2.5, 1.4, 21, and 41 µg/cm(2), respectively. The diffraction peaks attributed to calcium phosphate are present in the XRD patterns of the Ti-33 Mg alloy, Ti-55 Mg alloy, and Mg films after the immersion in Hanks' solution. Spherical calcium phosphate particles precipitate on the surface of the Ti-33 Mg film. However, many cracks are observed in the Ti-55 Mg film, and delamination of the film occurs after the immersion in Hanks' solution. The Mg film is dissolved in Hanks' solution and calcium phosphate particles precipitate on the glass substrate. Consequently, it is revealed that the Ti-33 Mg alloy film evaluated in this study is suitable for biomedical applications.


Assuntos
Ligas/química , Materiais Biocompatíveis/química , Magnésio/química , Titânio/química , Fosfatos de Cálcio/química , Corrosão , Teste de Materiais , Espectroscopia Fotoeletrônica , Propriedades de Superfície , Difração de Raios X
16.
Acta Biomater ; 12: 352-361, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25449914

RESUMO

In this study, various amounts of oxygen were added to Ti-10Cr (mass%) alloys. It is expected that a large changeable Young's modulus, caused by a deformation-induced ω-phase transformation, can be achieved in Ti-10Cr-O alloys by the appropriate oxygen addition. This "changeable Young's modulus" property can satisfy the otherwise conflicting requirements for use in spinal implant rods: high and low moduli are preferred by surgeons and patients, respectively. The influence of oxygen on the microstructures and mechanical properties of the alloys was examined, as well as the bending springback and cytocompatibility of the optimized alloy. Among the Ti-10Cr-O alloys, Ti-10Cr-0.2O (mass%) alloy shows the largest changeable Young's modulus following cold rolling for a constant reduction ratio. This is the result of two competing factors: increased apparent ß-lattice stability and decreased amounts of athermal ω phase, both of which are caused by oxygen addition. The most favorable balance of these factors for the deformation-induced ω-phase transformation occurred at an oxygen concentration of 0.2mass%. Ti-10Cr-0.2O alloy not only exhibits high tensile strength and acceptable elongation, but also possesses a good combination of high bending strength, acceptable bending springback and great cytocompatibility. Therefore, Ti-10Cr-0.2O alloy is a potential material for use in spinal fixture devices.


Assuntos
Ligas , Materiais Biocompatíveis , Cromo/química , Oxigênio/química , Coluna Vertebral/cirurgia , Titânio/química , Teste de Materiais
17.
J Mech Behav Biomed Mater ; 41: 208-20, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25460417

RESUMO

The predominant factor determining the wear properties of a new titanium alloy, Ti-29Nb-13Ta-4.6Zr (TNTZ) and a conventional titanium alloy, Ti-6Al-4V extra-low interstitial (Ti64) was investigated for TNTZ and Ti64 combinations in metal-to-metal contacting bio-implant applications. The worn surfaces, wear debris, and subsurface damages were analyzed using a scanning electron microscopy combined with energy-dispersive spectroscopy and electron-back scattered diffraction analysis. The volume loss of TNTZ is found to be larger than that of Ti64, regardless of the mating material. The wear track of TNTZ exhibits the galled regions and severe plastic deformation with large flake-like debris, indicative of delamination wear, which strongly suggests the occurrence of adhesive wear. Whereas, the wear track of Ti64 have a large number of regular grooves and microcuttings with cutting chip-like wear debris and microfragmentation of fine oxide debris, indicative of abrasive wear combined with oxidative wear. This difference in the wear type is caused by severe and mild subsurface deformations of TNTZ and Ti64, respectively. The lower resistance to plastic shearing for TNTZ compared to that of Ti64 induces delamination, resulting in a higher wear rate.


Assuntos
Ligas , Materiais Biocompatíveis , Teste de Materiais , Nióbio , Tantálio , Titânio , Zircônio , Dureza , Microscopia Eletrônica de Varredura , Próteses e Implantes , Propriedades de Superfície
18.
J Mech Behav Biomed Mater ; 35: 123-31, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24769914

RESUMO

Ag-Pd-Au-Cu alloys have been used widely for dental prosthetic applications. Significant enhancement of the mechanical properties of the Ag-20Pd-12Au-14.5Cu alloy as a result of the precipitation of the ß' phase through high-temperature solution treatment (ST), which is different from conventional aging treatment in these alloys, has been reported. The relationship between the unique hardening behavior and precipitation of the ß' phase in Ag-20Pd-12Au-xCu alloys (x=6.5, 13, 14.5, 17, and 20mass%) subjected to the high-temperature ST at 1123K for 3.6ks was investigated in this study. Unique hardening behavior after the high-temperature ST also occurs in Ag-20Pd-12Au-xCu alloys (x=13, 17, and 20) with precipitation of the ß' phase. However, hardening is not observed and the ß' phase does not precipitate in the Ag-20Pd-12Au-6.5Cu alloy after the same ST. The tensile strength and 0.2% proof stress also increase in Ag-20Pd-12Au-xCu alloys (x=13, 14.5, 17, and 20) after the high-temperature ST. In addition, these values after the high-temperature ST increase with increasing Cu content in Ag-20Pd-12Au-xCu alloys (x=14.5, 17, and 20). The formation process of the ß' phase can be explained in terms of diffusion of Ag and Cu atoms and precipitation of the ß' phase. Clarification of the relationship between hardening and precipitation of the ß' phase via high-temperature ST is expected to help the development of more effective heat treatments for hardening in Ag-20Pd-12Au-xCu alloys.


Assuntos
Cobre/química , Ligas Dentárias/química , Materiais Dentários/química , Prótese Dentária , Análise do Estresse Dentário/métodos , Ligas/química , Difusão , Ouro/química , Dureza , Temperatura Alta , Teste de Materiais , Microscopia Eletrônica de Transmissão e Varredura , Espectrofotometria , Estresse Mecânico , Resistência à Tração , Difração de Raios X , Raios X
19.
Mater Sci Eng C Mater Biol Appl ; 37: 204-9, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24582241

RESUMO

Dental Ag-20Pd-12Au-14.5Cu alloys exhibit a unique hardening behavior, which the mechanical strengths enhance significantly which enhances the mechanical strength significantly after high-temperature (1123K) solution treatment without aging treatment. The mechanism of the unique hardening is not clear. The contribution of two precipitates (ß' and ß phases) to the unique hardening behavior in the as-solutionized Ag-20Pd-12Au-14.5Cu alloys was investigated. In addition, the chemical composition of the ß' phase was investigated. The fine ß' phase densely precipitates in a matrix. The ß' phase (semi-coherent precipitate), which causes lattice strain, contributes greatly to the unique hardening behavior. On the other hand, the coarse ß phase sparsely precipitates in the matrix. The contribution of the ß phase (incoherent precipitate), which does not cause lattice strain, is small. The chemical composition of the ß' phase was determined. This study reveals that the fine ß' phase precipitated by high-temperature solution treatment leads to the unique hardening behavior in dental Ag-20Pd-12Au-14.5Cu alloys in the viewpoints of the lattice strain contrast and interface coherency. It is expected to make the heat treatment process more practical for hardening. The determined chemical composition of ß' phase would be helpful to study an unknown formation process of ß' phase.


Assuntos
Ligas Dentárias/química , Prótese Dentária , Dureza , Temperatura Alta , Soluções/química
20.
J Mech Behav Biomed Mater ; 34: 66-74, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24561725

RESUMO

The springback behavior of Ti-12Cr and Ti-29Nb-13Ta-4.6Zr (TNTZ) during deformation by bending was investigated; and the microstructures of the non-deformed and deformed parts of both alloys were systematically examined to clarify the relationship between microstructure and springback behavior. For the deformed Ti-12Cr alloy, deformation-induced ω-phase transformation occurs in both the areas of compression and tension within the deformed part, which increases the Young׳s modulus. With the deformed TNTZ alloy, deformation-induced ω-phase transformation is observed in the area of compression within the deformed part; while a deformation-induced α″ martensite transformation occurs in the area under tension, which is likely to be associated with the pseudoelasticity of TNTZ. Among these two alloys, Ti-12Cr exhibits a smaller springback and a much greater bending strength when compared with TNTZ; making Ti-12Cr the more advantageous for spinal fixation applications.


Assuntos
Ligas/química , Cromo/química , Módulo de Elasticidade , Teste de Materiais , Nióbio/química , Transição de Fase , Coluna Vertebral/cirurgia , Tantálio/química , Titânio/química , Zircônio/química , Força Compressiva , Estresse Mecânico , Dispositivos de Fixação Cirúrgica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA