Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Environ Pollut ; 180: 221-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23792381

RESUMO

This study investigated potential ammonia impacts on a sand dune nature reserve 600 m upwind of an intensive poultry unit. Ammonia concentrations and total nitrogen deposition were measured over a calendar year. A series of ammonia and nitrogen exposure experiments using dune grassland species were conducted in controlled manipulations and in the field. Ammonia emissions from the intensive poultry unit were detected up to 2.8 km upwind, contributing to exceedance of critical levels of ammonia 800 m upwind and exceedance of critical loads of nitrogen 2.8 km upwind. Emissions contributed 30% of the total N load in parts of the upwind conservation site. In the nitrogen exposure experiments, plants showed elevated tissue nitrogen contents, and responded to ammonia concentrations and nitrogen deposition loads observed in the conservation site by increasing biomass. Estimated long-term impacts suggest an increase in the soil carbon pool of 9% over a 50-year timescale.


Assuntos
Poluentes Atmosféricos/análise , Amônia/análise , Monitoramento Ambiental , Aves Domésticas , Criação de Animais Domésticos , Animais
2.
Australas Phys Eng Sci Med ; 29(3): 278-80, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17058591

RESUMO

Illuminance level in the softcopy image viewing room is a very important factor to optimize productivity in radiological diagnosis. In today's radiological environment, the illuminance measurements are normally done during the quality control procedure and performed annually. Although the room is equipped with dimmer switches, radiologists are not able to decide the level of illuminance according to the standards. The aim of this study is to develop a simple real-time illuminance detector system to assist the radiologists in deciding an adequate illuminance level during radiological image viewing. The system indicates illuminance in a very simple visual form by using light emitting diodes. By employing the device in the viewing room, illuminance level can be monitored and adjusted effectively.


Assuntos
Monitoramento Ambiental/instrumentação , Iluminação/instrumentação , Fotometria/instrumentação , Radiologia/instrumentação , Transdutores , Monitoramento Ambiental/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Fotometria/métodos , Radiologia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA