Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
medRxiv ; 2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32793919

RESUMO

T cells are involved in the early identification and clearance of viral infections and also support the development of antibodies by B cells. This central role for T cells makes them a desirable target for assessing the immune response to SARS-CoV-2 infection. Here, we combined two high-throughput immune profiling methods to create a quantitative picture of the T-cell response to SARS-CoV-2. First, at the individual level, we deeply characterized 3 acutely infected and 58 recovered COVID-19 subjects by experimentally mapping their CD8 T-cell response through antigen stimulation to 545 Human Leukocyte Antigen (HLA) class I presented viral peptides (class II data in a forthcoming study). Then, at the population level, we performed T-cell repertoire sequencing on 1,815 samples (from 1,521 COVID-19 subjects) as well as 3,500 controls to identify shared "public" T-cell receptors (TCRs) associated with SARS-CoV-2 infection from both CD8 and CD4 T cells. Collectively, our data reveal that CD8 T-cell responses are often driven by a few immunodominant, HLA-restricted epitopes. As expected, the T-cell response to SARS-CoV-2 peaks about one to two weeks after infection and is detectable for at least several months after recovery. As an application of these data, we trained a classifier to diagnose SARS-CoV-2 infection based solely on TCR sequencing from blood samples, and observed, at 99.8% specificity, high early sensitivity soon after diagnosis (Day 3-7 = 85.1% [95% CI = 79.9-89.7]; Day 8-14 = 94.8% [90.7-98.4]) as well as lasting sensitivity after recovery (Day 29+/convalescent = 95.4% [92.1-98.3]). These results demonstrate an approach to reliably assess the adaptive immune response both soon after viral antigenic exposure (before antibodies are typically detectable) as well as at later time points. This blood-based molecular approach to characterizing the cellular immune response has applications in clinical diagnostics as well as in vaccine development and monitoring.

2.
J Am Chem Soc ; 142(5): 2110-2114, 2020 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-31985216

RESUMO

Unnatural base pairs (UBPs) have been developed and used for a variety of in vitro applications as well as for the engineering of semisynthetic organisms (SSOs) that store and retrieve increased information. However, these applications are limited by the availability of methods to rapidly and accurately determine the sequence of unnatural DNA. Here we report the development and application of the MspA nanopore to sequence DNA containing the dTPT3-dNaM UBP. Analysis of two sequence contexts reveals that DNA containing the UBP is replicated with an efficiency and fidelity similar to that of natural DNA and sufficient for use as the basis of an SSO that produces proteins with noncanonical amino acids.


Assuntos
Pareamento de Bases , Código Genético , Nanoporos , Interações Hidrofóbicas e Hidrofílicas
3.
Nat Biotechnol ; 37(6): 651-656, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31011178

RESUMO

Nanopore DNA sequencing is limited by low base-calling accuracy. Improved base-calling accuracy has so far relied on specialized base-calling algorithms, different nanopores and motor enzymes, or biochemical methods to re-read DNA molecules. Two primary error modes hamper sequencing accuracy: enzyme mis-steps and sequences with indistinguishable signals. We vary the driving voltage from 100 to 200 mV, with a frequency of 200 Hz, across a Mycobacterium smegmatis porin A (MspA) nanopore, thus changing how the DNA strand moves through the nanopore. A DNA helicase moves the DNA through the nanopore in discrete steps, and the variable voltage moves the DNA continuously between these steps. The electronic signal produced with variable voltage is used to overcome the primary error modes in base calling. We found that single-passage de novo base-calling accuracy of 62.7 ± 0.5% with a constant driving voltage improves to 79.3 ± 0.3% with a variable driving voltage. The variable-voltage sequencing mode is complementary to other methods to boost the accuracy of nanopore sequencing and could be incorporated into any enzyme-actuated nanopore sequencing device.


Assuntos
DNA Helicases/genética , DNA/genética , Nanoporos , Porinas/genética , Algoritmos , DNA/isolamento & purificação , DNA Helicases/química , Mycobacterium smegmatis/genética , Porinas/química , Análise de Sequência de DNA/métodos
4.
Nucleic Acids Res ; 47(5): 2506-2513, 2019 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-30649515

RESUMO

Motor enzymes that process nucleic-acid substrates play vital roles in all aspects of genome replication, expression, and repair. The DNA and RNA nucleobases are known to affect the kinetics of these systems in biologically meaningful ways. Recently, it was shown that DNA bases control the translocation speed of helicases on single-stranded DNA, however the cause of these effects remains unclear. We use single-molecule picometer-resolution nanopore tweezers (SPRNT) to measure the kinetics of translocation along single-stranded DNA by the helicase Hel308 from Thermococcus gammatolerans. SPRNT can measure enzyme steps with subangstrom resolution on millisecond timescales while simultaneously measuring the absolute position of the enzyme along the DNA substrate. Previous experiments with SPRNT revealed the presence of two distinct substates within the Hel308 ATP hydrolysis cycle, one [ATP]-dependent and the other [ATP]-independent. Here, we analyze in-depth the apparent sequence dependent behavior of the [ATP]-independent step. We find that DNA bases at two sites within Hel308 control sequence-specific kinetics of the [ATP]-independent step. We suggest mechanisms for the observed sequence-specific translocation kinetics. Similar SPRNT measurements and methods can be applied to other nucleic-acid-processing motor enzymes.


Assuntos
DNA Helicases/genética , DNA de Cadeia Simples/genética , DNA/genética , Translocação Genética , Trifosfato de Adenosina/química , Trifosfato de Adenosina/genética , DNA/química , DNA Helicases/química , Hidrólise , Cinética , Nanoporos , Thermococcus/enzimologia
5.
Proc Natl Acad Sci U S A ; 114(45): 11932-11937, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-29078357

RESUMO

Enzymes that operate on DNA or RNA perform the core functions of replication and expression in all of biology. To gain high-resolution access to the detailed mechanistic behavior of these enzymes, we developed single-molecule picometer-resolution nanopore tweezers (SPRNT), a single-molecule technique in which the motion of polynucleotides through an enzyme is measured by a nanopore. SPRNT reveals two mechanical substates of the ATP hydrolysis cycle of the superfamily 2 helicase Hel308 during translocation on single-stranded DNA (ssDNA). By analyzing these substates at millisecond resolution, we derive a detailed kinetic model for Hel308 translocation along ssDNA that sheds light on how superfamily 1 and 2 helicases turn ATP hydrolysis into motion along DNA. Surprisingly, we find that the DNA sequence within Hel308 affects the kinetics of helicase translocation.


Assuntos
DNA Helicases/metabolismo , Replicação do DNA/fisiologia , DNA de Cadeia Simples/química , Pinças Ópticas , Difosfato de Adenosina/química , Trifosfato de Adenosina/química , Humanos , Cinética , Imagem Individual de Molécula , Translocação Genética/fisiologia
6.
PLoS One ; 12(7): e0181599, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28749972

RESUMO

Nanopore DNA sequencing is a promising single-molecule analysis technology. This technique relies on a DNA motor enzyme to control movement of DNA precisely through a nanopore. Specific experimental buffer conditions are required based on the preferred operating conditions of the DNA motor enzyme. While many DNA motor enzymes typically operate in salt concentrations under 100 mM, salt concentration simultaneously affects signal and noise magnitude as well as DNA capture rate in nanopore sequencing, limiting standard experimental conditions to salt concentrations greater than ~100 mM in order to maintain adequate resolution and experimental throughput. We evaluated the signal contribution from ions on both sides of the membrane (cis and trans) by varying cis and trans [KCl] independently during phi29 DNA Polymerase-controlled translocation of DNA through the biological porin MspA. Our studies reveal that during DNA translocation, the negatively charged DNA increases cation selectivity through MspA with the majority of current produced by the flow of K+ ions from trans to cis. Varying trans [K+] has dramatic effects on the signal magnitude, whereas changing cis [Cl-] produces only small effects. Good signal-to-noise can be maintained with cis [Cl-] as small as 20 mM, if the concentration of KCl on the trans side is kept high. These results demonstrate the potential of using salt-sensitive motor enzymes (helicases, polymerases, recombinases) in nanopore systems and offer a guide for selecting buffer conditions in future experiments to simultaneously optimize signal, throughput, and enzyme activity.


Assuntos
Proteínas de Bactérias/química , Porinas/química , Potássio/química , Cloretos/química , DNA de Cadeia Simples/química , Cinética , Nanotecnologia , Análise de Sequência de DNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA