RESUMO

Cochlear implants (CIs) are neuroprosthetics that can provide a sense of sound to people with severe-to-profound hearing loss. A CI contains an electrode array (EA) that is threaded into the cochlea during surgery. Recent studies have shown that hearing outcomes are correlated with EA placement. An image-guided cochlear implant programming technique is based on this correlation and utilizes the EA location with respect to the intracochlear anatomy to help audiologists adjust the CI settings to improve hearing. Automated methods to localize EA in postoperative CT images are of great interest for large-scale studies and for translation into the clinical workflow. In this work, we propose a unified deep-learning-based framework for automated EA localization. It consists of a multi-task network and a series of postprocessing algorithms to localize various types of EAs. The evaluation on a dataset with 27 cadaveric samples shows that its localization error is slightly smaller than the state-of-the-art method. Another evaluation on a large-scale clinical dataset containing 561 cases across two institutions demonstrates a significant improvement in robustness compared to the state-of-the-art method. This suggests that this technique could be integrated into the clinical workflow and provide audiologists with information that facilitates the programming of the implant leading to improved patient care.

2.
Simul Synth Med Imaging ; 14288: 11-20, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38560492

RESUMO

Cochlear implants (CIs) are considered the standard-of-care treatment for profound sensory-based hearing loss. Several groups have proposed computational models of the cochlea in order to study the neural activation patterns in response to CI stimulation. However, most of the current implementations either rely on high-resolution histological images that cannot be customized for CI users or CT images that lack the spatial resolution to show cochlear structures. In this work, we propose to use a deep learning-based method to obtain µCT level tissue labels using patient CT images. Experiments showed that the proposed super-resolution segmentation architecture achieved very good performance on the inner-ear tissue segmentation. Our best-performing model (0.871) outperformed the UNet (0.746), VNet (0.853), nnUNet (0.861), TransUNet (0.848), and SRGAN (0.780) in terms of mean dice score.

3.
Med Image Comput Comput Assist Interv ; 14228: 249-259, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38515783

RESUMO

In cochlear implant (CI) procedures, an electrode array is surgically inserted into the cochlea. The electrodes are used to stimulate the auditory nerve and restore hearing sensation for the recipient. If the array folds inside the cochlea during the insertion procedure, it can lead to trauma, damage to the residual hearing, and poor hearing restoration. Intraoperative detection of such a case can allow a surgeon to perform reimplantation. However, this intraoperative detection requires experience and electrophysiological tests sometimes fail to detect an array folding. Due to the low incidence of array folding, we generated a dataset of CT images with folded synthetic electrode arrays with realistic metal artifact. The dataset was used to train a multitask custom 3D-UNet model for array fold detection. We tested the trained model on real post-operative CTs (7 with folded arrays and 200 without). Our model could correctly classify all the fold-over cases while misclassifying only 3 non fold-over cases. Therefore, the model is a promising option for array fold detection.