Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Heart Vessels ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38494555

RESUMO

Epicardial adipose tissue (EAT) induces inflammation in the atria and is associated with atrial fibrillation (AF). Several studies have examined the relationship between EAT volume (EAT-V) and density (EAT-D) and the presence of AF after catheter ablation. However, conclusions have been inconsistent. This study included 43 consecutive patients who underwent catheter ablation for AF and 30 control patients. EAT-V and EAT-D around the entire heart, entire atrium, left atrium (LA), and right atrium (RA) were measured in detail using reconstructed three-dimensional (3D) EAT images from dual-source computed tomography (CT). None of the measurements of EAT-V differed significantly between patients with AF and controls or between patients with recurrent AF and those without. On the other hand, all measurements of EAT-D were higher in patients with AF than in controls (entire atrium, p < 0.001; RA, p < 0.001; LA, p = 0.002). All EAT-D measurements were associated with the presence of AF. Among patients with AF who underwent ablation, all EAT-D measurements were higher in patients with recurrent AF than in those without. The difference was significant for EATRA-D (p = 0.032). All atrial EAT-D values predicted recurrent AF (EATRA-D: hazard ratio [HR], 1.208; 95% confidence interval [95% CI], 1.053-1.387; p = 0.007; EATLA-D: HR, 1.108; 95% CI 1.001-1.225; p = 0.047; EATatrial-D: HR, 1.174; 95% CI 1.040-1.325; p = 0.010). The most sensitive cutoffs for predicting recurrent AF were highly accurate for EATRA-D (area under the curve [AUC], 0.76; p < 0.01) and EATatrial-D (AUC = 0.75, p < 0.05), while the cutoff for EATLA-D had low accuracy (AUC, 0.65; p = 0.209). For predicting the presence of AF and recurrent AF after catheter ablation, 3D analysis of atrial EAT-D, rather than EAT-V, is useful.

2.
J Arrhythm ; 39(6): 884-893, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38045469

RESUMO

Background: This study thought to elucidate the anatomical features that can predict an epicardial connection (EC) between the right pulmonary vein (RPV) and right atrium. Methods: We retrospectively analyzed 251 consecutive patients undergoing initial radiofrequency pulmonary vein isolation. We defined EC as present when RPV could not be isolated with circumferential ablation and additional ablation for the conduction gap if needed, and RPV isolation could be achieved by ablation for the earliest activation site >10 mm inside the initial ablation line. Using computed tomography data, we evaluated the RPV bifurcation angle, and the area occupation ratio of the carina region to the RPV antrum (ARC) for predicting EC. In subjects with EC undergoing RPV activation mapping after circumferential ablation, the correlation between conduction delay and bipolar/unipolar potential voltage in the carina region was investigated. Results: There were ECs in 45 out of 251 patients (17.9%). The RPV bifurcation angle (47.7° vs. 38.8°, p < .001) and ARC (37.2% vs. 29.7%, p < .001) were significantly greater in the EC (+) group. Multivariate logistic regression analysis revealed that RPV bifurcation angle (odds ratio [OR]: 1.994, p = .002) and ARC (OR: 3.490, p = .013) were independent predictors of EC. In nine patients with EC undergoing carina region mapping, the unipolar potential voltage was correlated with conduction delay in RPV with EC (R = -0.401, p < .001). Conclusion: Anatomical features suggesting a wider RPV carina region could predict the presence of EC, and potential with high voltage could be helpful for detecting EC connection sites.

3.
J Cardiovasc Electrophysiol ; 34(9): 1969-1978, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37482964

RESUMO

INTRODUCTION: Atrial premature beats (APBs) are the trigger for atrial fibrillation (AF). We sought to investigate the clinical significance of APB occurrence 1 day after pulmonary vein isolation (PVI) for AF using a short-time electrocardiogram. METHODS: A total of 206 patients undergoing PVI for paroxysmal AF were included. Electrocardiogram recording for 100 consecutive beats was performed 1 day after PVI. The patients were divided into two groups: those with reproducible APBs (≥1 beat) during reassessment (APB group, n = 49) or those without (non-APB group, n = 157). Late recurrence was defined as atrial tachyarrhythmia recurrence 3-12 months after PVI. The impact of APB occurrence on outcomes was investigated. RESULTS: Late recurrence occurred in 19 patients (9.2%). The presence of low-voltage areas, left atrial volume, and recurrence rate were higher in the APB group than in the non-APB group. In the APB group, the patients with recurrence had lower prematurity index (PI, coupling interval of APB/previous cycle length) compared to those without. Receiver-operating characteristic analysis revealed PI (<59.3) to be a predictive factor of recurrence (area under the curve: 0.733). The study subjects were then reclassified into three groups according to the absence of APB occurrence (n = 157), presence thereof with PI ≥ 59.3 (n = 33), and presence with PI < 59.3 (n = 16). The multivariate Cox models revealed that APB with PI < 59.3 was an independent predictor for recurrence (hazard ratio, 8.735; p < 0.001). CONCLUSION: A short-time electrocardiogram enables risk assessment for arrhythmia recurrence, and APB with low PI 1 day after PVI is a powerful predictor.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Complexos Atriais Prematuros/diagnóstico , Recidiva
4.
Int Heart J ; 64(4): 614-622, 2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37460316

RESUMO

Radiofrequency catheter ablation (RFCA) to treat ventricular arrhythmias (VAs) originating below the His bundle (HB) region of the right ventricular (RV) septum could impair the atrioventricular node conduction. This study aimed to clarify the parameters of the 12-lead electrocardiography that predict successful RFCA of VAs originating from this region. This study included 20 consecutive patients (13 men; mean age, 68 ± 7 years) with monomorphic VAs in whom the earliest ventricular activation during the VA was below the HB region of the RV septum. According to the ablation results, the patients were divided into two groups: successful ablation (S-group; n = 10) and failed ablation groups (F-group; n = 10). The electrocardiographic parameters during the VAs and RFCA results were assessed. The R wave amplitudes in leads aVL (P = 0.001) and I (P = 0.010) in the S-group were both smaller than those in the F-group. In addition, the S-group had smaller negative deflection amplitudes in leads III (P = 0.002) and aVF (P = 0.003) than the F-group. According to the receiver operating characteristic curve analysis, the most useful electrocardiographic parameter for predicting successful ablation was the R wave amplitude in lead aVL (area under the curve, 0.895; P < 0.001); a cutoff value of < 1.3 mV predicted a successful RFCA with the highest accuracy (sensitivity, 90%; specificity, 80%; positive predictive value, 82%; negative predictive value, 89%). The R wave amplitude in lead aVL was the most useful parameter for predicting a successful RFCA to treat VAs originating below the HB region of the RV septum.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Ventrículos do Coração , Fascículo Atrioventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Eletrocardiografia/métodos , Ablação por Cateter/métodos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 34(3): 565-574, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36571163

RESUMO

INTRODUCTION: Epicardial adipose tissue (EAT) exacerbates both electrical and structural remodeling in obese atrial fibrillation (AF) patients, but the impacts of EAT on atrial arrhythmogenicity remain unclear in normal-weight AF patients. Therefore, we sought to investigate this issue using electroanatomic mapping. METHODS AND RESULTS: We enrolled drug-refractory 105 paroxysmal AF patients in the normal body mass index range (18.5-24.9 kg/m2 ), who had undergone electroanatomic mapping after pulmonary vein isolation (PVI). One day before PVI, we assessed P-wave duration in a 12-lead electrocardiogram and left atrial (LA)-EAT volumes using contrast-enhanced computed tomography. The patients were divided into two groups based on the median LA-EAT volume (16.0 ml); the high LA-EAT group (≥16.0 ml, n = 53) and low LA-EAT group (<16.0 ml, n = 52). We compared P-wave duration, LA conduction velocity and bipolar voltage, the presence of low-voltage zone (<0.5 mV), and LA volume index on echocardiography between the two groups. The LA bipolar voltage, low-voltage zone, and LA volume index were not different between the high and low LA-EAT groups. However, P-wave duration was significantly longer in the high group than in the low group (p < .001). Additionally, the LA conduction velocity was significantly more depressed in the high group than in the low group (p < .001). Multivariate linear regression analysis revealed that LA-EAT volume was correlated with P-wave duration (ß = .367, p < .001) and conduction velocity (ß = -.566, p < .001), respectively. CONCLUSIONS: Increased LA-EAT volumes were associated with electrical conduction disturbance after PVI in normal-weight patients with AF. P-wave duration may be a clinically useful predictor of LA-EAT.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Átrios do Coração , Tecido Adiposo , Ablação por Cateter/métodos , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 33(12): 2599-2605, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36104930

RESUMO

BACKGROUND: Even a short duration of paroxysmal episodes of atrial fibrillation (AF) is associated with sinus node (SN) remodeling and a reduced SN reserve or dysfunction. The number of earliest atrial activation sites (EASs) during sinus rhythm decreases according to the decrease in the SN reserve. OBJECTIVE: We sought to evaluate the EASs during sinus rhythm using an ultrahigh-density mapping system. METHODS: This study included 35 patients (supraventricular tachycardia [SVT]/paroxysmal atrial fibrillation [PAF]/persistent atrial fibrillation [PsAF] = 5/21/9) who underwent ultrahigh-resolution endocardial mapping of the SN area at rest and during ß-stimulation. The number of EASs was determined by the Lumipoint™ algorithm. RESULTS: The number of EASs was greatest in SVT patients both at rest (SVT/PAF/PsAF = 1.4 ± 0.8/1.0 ± 0/1.0 ± 0, p = .04) and during ß-stimulation (SVT/PAF/PsAF = 2.6 ± 1.0/1.3 ± 0.6/1.0 ± 0, p < .01). The number significantly increased with ß-stimulation as compared to baseline in the PAF patients (p = .02), but not in the PsAF patients. The brain natriuretic peptide (BNP) level was significantly higher in AF than SVT patients (SVT/PAF/PsAF = 12.3 [10.1-14.5]/25.7 [14.8-36.0]/73.4 [57.6-140] pg/ml, p < .01). In the PAF patients, the BNP level was significantly higher in those with unicentric EASs than multicentric EASs during ß-stimulation (28.1 [19.1-46.5] vs. 13.1 [9.4-26.9] pg/ml, p = .03), and the optimal cutoff point for the BNP level predicting unicentric EASs was 21.8 pg/ml (sensitivity 82.6%; specificity 85.7%). CONCLUSIONS: AF patients have a smaller number of EASs and poorer response to ß-stimulation than non-AF patients. An elevated BNP level might predict subclinical SN dysfunction in patients with PAF.


Assuntos
Fibrilação Atrial , Taquicardia Paroxística , Taquicardia Supraventricular , Humanos , Fibrilação Atrial/diagnóstico , Síndrome do Nó Sinusal , Átrios do Coração , Nó Sinoatrial
7.
PLoS One ; 17(8): e0273541, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35998187

RESUMO

BACKGROUND: A 12-lead electrocardiogram (ECG) and Holter ECG have been established as gold standards for detection of arrhythmias. Recently, wearable ECG monitoring devices have been available. Our purpose of the present study was to investigate whether a novel wearable electrode embedded in an undershirt is useful for ECG monitoring and detection of arrhythmias. METHODS: We studied 31 consecutive hospitalized patients who underwent catheter ablation of tachyarrhythmias. Patients equipped a wearable electrode and a lead CM5 of Holter ECG simultaneously, and total heart beats, maximum heart rate (HR), mean HR, minimum HR, detections of arrhythmias, such as atrial fibrillation, non-sustained ventricular tachycardia, and premature ventricular contractions (Lown's grade >II), were compared between the two methods using a Holter ECG analysis software. RESULTS: Median recording time of ECG by wearable electrodes was 12.6 hours. Strong correlations between the two methods were observed in total heart beats (R = 0.999, P <0.001), maximum HR (R = 0.997, P <0.001), mean HR (R = 0.999, P <0.001), minimum HR (R = 0.989, P <0.001) and QRS duration (R = 0.900, P <0.001). Bland-Altman analysis showed excellent concordance between each parameter measured by two methods. In addition, the detection of atrial fibrillation (nine events), non-sustained ventricular tachycardia (two events), and premature ventricular contractions of Lown's grade >II (five events) were concordant in two methods. In addition, there were no significant difference in parameters of time-domain and frequency-domain analyses of heart rate variability between the two methods. CONCLUSIONS: The usefulness of a novel electrode embedded in an undershirt is equivalent to that of a Holter ECG in monitoring the ECG and detection of arrythmias.


Assuntos
Fibrilação Atrial , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial/métodos , Eletrodos , Humanos , Taquicardia Ventricular/diagnóstico , Complexos Ventriculares Prematuros/diagnóstico
8.
Heart Vessels ; 37(8): 1425-1435, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35174414

RESUMO

Interatrial conduction consists of various muscular bundles, including the Bachmann bundle. In this study, we investigated interatrial activation patterns using ultrahigh-resolution left atrial endocardial mapping. This study investigated 58 patients who underwent catheter ablation of atrial arrhythmia via an ultrahigh-resolution mapping system (Rhythmia) at our hospital from May 2020 to January 2021. Left atrial voltage maps and activation maps were acquired after the ablation procedure during right atrial appendage (RAA) pacing. We defined left atrial breakout sites (LABSs) as centrifugal activation patterns shown by the LUMIPOINT Activation Search Tool. The distance between each LABS in the left atrial anterior wall and the superior border of the interatrial septum (DLABS-IAS) was measured on the shell of the electroanatomical map, and anterior LABSs were divided equally into roof- and septal-side groups. Fifty-three (91%) patients underwent cryoballoon pulmonary vein isolation. Ultrahigh-resolution left atrial mapping was successfully performed in all patients (6831 ± 2158 points). A total of 82 LABSs were identified in left atrial anterior wall; 34 patients had single LABS and 24 patients had dual LABSs. The mean DLABS-IAS was 10.3 ± 9.6 mm. Seven patients also exhibited posterior LABS near the interatrial raphe below the right inferior pulmonary vein. Patients with a single roof-side LABS had significantly shorter left atrial activation times than those with a single septal-side LABS (81.6 ± 13.2 ms vs. 93.5 ± 13.7 ms, p < 0.05). Interatrial conduction patterns during RAA pacing varied between patients and affected the left atrial activation time.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter/efeitos adversos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia
9.
BMC Cardiovasc Disord ; 22(1): 57, 2022 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-35172730

RESUMO

BACKGROUND: Left atrial roof-dependent tachycardias (LARTs) are common macroreentrant atrial tachycardias (ATs). We sought to characterize clinical LARTs using an ultra-high resolution mapping system. METHODS: This study included 22 consecutive LARTs in 21 patients who underwent AT mapping/ablation using Rhythmia systems. RESULTS: Three, 13, 4, and 2 LART patients were cardiac intervention naïve (Group-A), post-roof line ablation (Group-B), post-atrial fibrillation ablation without linear ablation (Group-C), and post-cardiac surgery (Group-D), respectively. The mean AT cycle length was 244 ± 43 ms. Coronary sinus activation was proximal-to-distal or distal-to-proximal in 16 (72.7%) ATs. The activation map revealed 13 (59.1%) clockwise and 9 (40.9%) counter-clockwise LARTs. A 12-lead synchronous isoelectric interval was observed in 10/19 (52.6%) LARTs. The slow conduction area was identified on the LA roof, anterior/septal wall, and posterior wall in 18, 6, and 2 ATs, respectively. Twenty concomitant ATs among 13 procedures were also eliminated, and peri-mitral AT coexisted in 7 of 9 non-group-B patients. In group-B, the conduction gap was predominantly located on the mid-roof. Sustained LARTs were terminated by a single application and linear ablation in 6 (27.3%) and 9 (40.9%), while converting to other ATs in 7 (31.8%) LARTs. Complete linear block was created without any complications in all, however, ablation at the mid-posterior wall was required to achieve block in 4 (18.2%) procedures. During 14.0 (6.5-28.5) months of follow-up, 17 (81.0%) and 19 (90.5%) patients were free from any atrial tachyarrhythmias after single and last procedures. CONCLUSIONS: The LART mechanisms were distinct in individual patients, and elimination of all concomitant ATs was required for the management.


Assuntos
Potenciais de Ação , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Átrios do Coração/cirurgia , Taquicardia Supraventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Feminino , Átrios do Coração/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
10.
Heart Vessels ; 37(7): 1203-1212, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35064297

RESUMO

The electrophysiological properties of the gap associated with the cavotricuspid isthmus (CTI) block line near the inferior vena cava (IVC) are not fully elucidated. Of 143 patients who underwent CTI block line ablation between September 2020 and April 2021, high-resolution CTI gap mapping was performed for 15 patients. Four patients were identified as having a gap near the IVC (IVC-side gap) despite wide double potentials (DPs) with > 90 ms intervals at the block line. Detailed gap mapping during coronary sinus ostial pacing was performed before and after touch-up ablation. CTI conduction delays caused by an IVC-side gap were classified into 3 patterns: (1) conduction delay at the IVC-side gap without detouring gap conduction, (2) detouring gap conduction due to intrinsic lower lateral right atrium (LLRA)-IVC functional block, and (3) detouring gap conduction due to LLRA-IVC conduction block created by lateral deviation of the CTI ablation line. In Pattern 2, IVC-side gap conduction traveled backward toward the crista terminalis below the LLRA-IVC junction and came back forward again above the border. One patient presented with a head-to-bottom activation pattern of the lateral right atrium (pseudo-CTI block). Pattern 3 was caused by lateral deviation of initial RF deliveries and presented with the same course as intrinsic LLRA-IVC functional block. All patients had wide DP intervals near the tricuspid annulus (mean, 112 ms) and just above the gap site (mean, 109 ms). An IVC-side gap associated with the CTI block line can present with various conduction delay patterns.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Átrios do Coração/cirurgia , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Veia Cava Inferior/cirurgia
11.
BMC Cardiovasc Disord ; 22(1): 14, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35067224

RESUMO

PURPOSE: The purpose of this study was to investigate the safety and efficacy of high-power short-duration (HP-SD) ablation compared to conventional ablation in patients with atrial fibrillation (AF). METHODS: We enrolled consecutive 158 drug-refractory symptomatic AF patients (119 males, mean age 63 ± 10 years) who had undergone first radiofrequency pulmonary vein isolation (PVI). PVI was performed using the conventional setting (20-35 W) in 73 patients (Conventional group) and using the HP-SD setting (45-50 W) in 85 patients (HP-SD group). The rate of first pass isolation, remaining gaps after circumferential ablation, dormant conduction, and the radiofrequency application time in each pulmonary vein (PV) were compared between the groups. RESULTS: The first pass isolation ratio was significantly higher in the HP-SD group than in the Conventional group (81% vs. 65%, P = 0.027) in the right PV, but did not differ in the left PV. The remaining gaps were fewer in the right superior PV (4% vs. 21%, P = 0.001) and left inferior PV (1% vs. 8%, P = 0.032) areas, and the radiofrequency application time in each PV was shorter (right PV, 12.0 ± 8.9 min vs. 34.0 ± 31.7 min, P < 0.001; left PV, 10.6 ± 3.6 min vs. 25.7 ± 22.3 min, P < 0.001) in the HP-SD group than in the Conventional group. CONCLUSION: The use of the HP-SD setting might contribute to improve the first pass isolation rate and to shorten the radiofrequency application time in each PV.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
12.
J Interv Card Electrophysiol ; 63(1): 143-152, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33575920

RESUMO

BACKGROUND: The novel fourth-generation cryoballoon (4th-CB) is characterized by a shorter-tip that potentially facilitates better time-to-isolation (TTI) monitoring. We sought to clarify the advantages and disadvantages of the 4th-CB compared to the second-generation cryoballoon (2nd-CB) in pulmonary vein isolation (PVI). METHODS: Forty-one and 49 consecutive atrial fibrillation patients underwent 2nd-CB and 4th-CB PVIs using 28-mm balloons and short freeze strategies. When effective freezing was not obtained, the CB was switched to the other CB. RESULTS: The rate of successful PVIs was significantly higher for 2nd-CBs than 4th-CBs (162/162[100%] vs. 178/193[92.2%] PVs, p < 0.0001). The difference was significant for lower PVs, especially right inferior PVs (RIPVs)(p = 0.005). In a total of 15 PVs in 11 patients, 4th-CBs were switched to 2nd-CBs, and 14/15(93.3%) PVs were successfully isolated. The balloon temperature tended to reach -55℃ more frequently with 2nd-CBs than 4th-CBs during RIPV ablations (15/41[36.6%] vs. 12/49[24.5%], p = 0.21). The TTI monitoring capability was significantly higher with 4th-CBs than 2nd-CBs (131/188[69.7%] vs. 83/160[51.9%] PVs, p = 0.0007). The difference was significant for right superior and left inferior PVs, but not for left superior PVs. Even if PVs requiring crossover were excluded, the total freeze duration (715±152 vs. 755±215 seconds, p = 0.31) tended to be shorter for 2nd-CBs than 4th-CBs. The incidence of phrenic nerve injury was similar for 2nd-CB and 4th-CB ablation (0/41 vs. 2/49, p = 0.12) CONCLUSIONS: The 4th-CB's shorter balloon tip enabled a significantly higher capability of TTI monitoring; however, it resulted in significantly lower rates of successful PVIs than the 2nd-CB, especially for the RIPVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Congelamento , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 45(5): 589-597, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34427933

RESUMO

BACKGROUND: Additional benefit of cryoballoon left atrial roof line ablation (CB-RA) beyond cryoballoon pulmonary vein isolation (CB-PVI) is suggested in patients with persistent atrial fibrillation (PsAF). We sought to investigate the feasibility of CB-RA for PsAF and to determine the ablation area. METHODS AND RESULTS: Fifty-three PsAF patients (67[58.5-75.5] years, 36 men, 11 longstanding PsAF) underwent CB-PVI. Subsequently, 44(83.0%) out of 53 patients underwent additional CB-RA. Voltage maps were created in all patients with a high-resolution mapping system. The total number and duration of CB-RAs were 3.9 ± 0.7 and 468 ± 84 s. LA roof areas were complete low voltage areas (LVAs) /scar in 37/44(84.1%) patients ("complete roof modification"). The normal LA posterior wall (LAPW) voltage area was 6.1(4.1-8.4) cm2 , and the %LAPW isolation area was 61.0(47.2-71.7)%. The %LAPW isolation area was significantly greater in CB-RA patients than those without (64.0[54.2-73.2] vs. 45.0[39.5-50.5]%, p = .041) despite significantly larger LAs in the former group. The %LAPW isolation area was significantly greater in patients with transverse LA diameters < 45 mm than those ≥ 45 mm (p < .0001). The single procedure 1-year AF freedom was 87.4% (22.5% on antiarrhythmic drug) and tended to be higher in CB-RA patients than those without. Among the 44 CB-RA patients, it was significantly higher in patients with a complete roof modification than those without (94.4% vs. 75.0%, p = .0049). One CB-RA patient experienced a delayed cardiac tamponade requiring drainage at 4-months post-procedure. CONCLUSIONS: CB-RA significantly expanded the LAPW isolation area, and a complete roof modification resulted in a high arrhythmia freedom in PsAF patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Cateter/métodos , Criocirurgia/métodos , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
14.
Ann Noninvasive Electrocardiol ; 27(1): e12900, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34676627

RESUMO

BACKGROUND: The clinical implications of chronic kidney disease (CKD) and cardiac sympathetic nervous activity (CSNA) regarding lethal arrhythmic events have not yet been fully elucidated in patients with chronic heart failure (CHF). We hypothesized that the combination of CKD and abnormal CSNA, assessed by 123 I-metaiodobenzylguanidine (123 I-MIBG) scintigraphy, may provide useful prognostic information for lethal arrhythmic events. METHODS: We studied 165 consecutive hospitalized CHF patients without dialysis. Cardiac 123 I-MIBG scintigraphy was performed in a clinically stable condition, and abnormal CSNA was defined as a late heart-to-mediastinum ratio of <1.6. CKD was defined as an estimated glomerular filtration rate of <60 ml/min/1.73 m2 . We then investigated the incidence of lethal arrhythmic events (sustained ventricular tachyarrhythmia, appropriate implantable cardioverter-defibrillator therapy, or sudden cardiac death). RESULTS: During a median follow-up of 5.3 years, lethal arrhythmic events were observed in 40 patients (24.2%). The patients were divided into four groups according to the presence of CKD and CSNA abnormality: non-CKD/normal CSNA (n = 52), CKD/normal CSNA (n = 39), non-CKD/abnormal CSNA (n = 33), and CKD/abnormal CSNA (n = 41). Kaplan-Meier analysis showed that CKD/abnormal CSNA had the highest event rate (log-rank p = .004). Additionally, the Cox proportional hazard analysis revealed that CKD/abnormal CSNA was a predictor for lethal arrhythmic events compared with non-CKD/normal CSNA (hazard ratio, 5.368, p = .001). However, the other two groups did not show significant differences compared with the non-CKD/normal CSNA group. CONCLUSIONS: The combination of CKD and abnormal CSNA, assessed by 123 I-MIBG scintigraphy, had a high predictive value for lethal arrhythmic events in patients with CHF.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Insuficiência Renal Crônica , 3-Iodobenzilguanidina , Doença Crônica , Eletrocardiografia , Coração , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Prognóstico , Insuficiência Renal Crônica/complicações
15.
J Cardiovasc Electrophysiol ; 33(1): 40-45, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34676946

RESUMO

BACKGROUND: Cavo-tricuspid isthmus (CTI) linear ablation is performed not only for atrial flutter (AFL) but empirically during atrial fibrillation (AF) ablation in real-world practice.  PURPOSE: We sought to evaluate the safety and durability of the CTI ablation.  METHODS: This retrospective study included 1078 consecutive patients who underwent a CTI ablation. AFL was documented before or during the procedure in 249 (23.1%) patients, and an empirical CTI and AF ablation were performed in 829 (76.9%) patients.  RESULTS: CTI block was successfully created in 1051 (97.5%) patients with a 10.3 ± 6.6 min total radiofrequency time. Repeat procedures were performed for recurrent arrhythmias in 187 (17.3%) patients at a median of 11.0 (5.0-30.0) months postprocedure, and conduction resumption was identified in 68/174 (39.1%). Among those undergoing a CTI ablation with an AF ablation, the durability was significantly higher in those with than without documented AFL (78.1% vs. 58.2%, p = .031).  The total radiofrequency time was significantly shorter (9.0 ± 5.3 vs. 10.0 ± 6.4 [mins], p = .024) and durability significantly higher (78.1 vs. 58.7[%], p = .043) in the large-tip than irrigated-tip catheter group. Iatrogenic AFL was observed after the empiric CTI ablation in 11 (1.3%) patients. Procedure-related complications occurred in 15 (1.4%) patients. Eight patients experienced coronary artery spasms, including one with ventricular fibrillation following ST elevation on the ward. The other six patients experienced transient atrioventricular block and one experienced cardiac tamponade requiring drainage.  CONCLUSIONS: Despite a high acute CTI ablation success, the conduction block durability was relatively low after the empiric ablation. An empiric CTI ablation at the time of the AF ablation is not recommended.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
16.
J Interv Card Electrophysiol ; 65(1): 25-31, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34468891

RESUMO

PURPOSE: High-power short-duration (HP-SD) ablation could reduce collateral tissue damage by shortening the conductive heating phase. However, it is difficult to evaluate the transmural effect of ablation lesions during pulmonary vein isolation (PVI) procedures. The present study aimed to evaluate the change in superior vena cava (SVC) potential delay as a surrogate marker of collateral tissue damage during right PVI, which is adjacent to SVC. METHODS: Out of 250 consecutive patients who underwent PVI, 86 patients in whom SVC potential during sinus rhythm was recorded both before and after right PVI were analyzed. In 46 of the patients, an HP-SD setting of 45-50 W was used (HP-SD group). In the remaining 40 patients, a conventional power setting of 20-30 W was used (conventional group). We compared the change in SVC potential delay after right PVI, radiofrequency energy, and mean contact force in the anterior-superior right PVI line, which was close to the posterior aspect of SVC, between the two groups. RESULTS: Although the total delivered radiofrequency energy (2,924 J vs. 2,604 J) and the mean contact force (18.5 g vs. 16.0 g) in the SVC overlapping area did not differ, the change in SVC potential delay after right PVI was significantly longer in the conventional group compared to the HP-SD group (5.0 ms vs. 0.0 ms, p < 0.001). CONCLUSIONS: The changes in SVC potential delay after right PVI might be a surrogate marker of collateral tissue damage according to the used energy settings.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Veia Cava Superior/cirurgia
17.
J Interv Card Electrophysiol ; 64(3): 581-586, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34292463

RESUMO

BACKGROUND: The time-to-isolation (TTI) may be a physiological predictor of durable isolations, and TTI-guided dosing strategies are widely performed in cryoballoon ablation. We sought to investigate the impact of the order of targeting the pulmonary veins (PVs) on the TTI values of left ipsilateral PVs. METHODS: This study included 144 atrial fibrillation patients who underwent PV isolations using 28-mm fourth-generation cryoballoons. In 101 patients, the left superior PV (LSPV) was targeted and followed by the left inferior PV (LIPV) (group 1), and the LIPV was targeted and followed by the LSPV in the remaining 43 (group 2). RESULTS: The total LSPV and LIPV freeze durations were 193 ± 60 and 171 ± 40 s, respectively. Real-time PV isolation monitoring was capable in 137 (95.1%) LSPVs and 119 (82.6%) LIPVs and in 112 (77.8%) patients (78 in group 1 and 34 in group 2) in both LSPVs and LIPVs. Among them, the LSPV TTI was significantly longer in group 1 than that in group 2 (54.8 ± 32.1 vs. 34.1 ± 17.3 s, p < 0.0001), while the LIPV TTI was significantly shorter in group 1 than that in group 2 (23.7 ± 11.8 vs. 39.2 ± 19.4 s, p < 0.0001). The ΔTTI ((TTI in LSPV)-(TTI in LIPV)) was significantly greater in group 1 than that in group 2 (31.1 ± 31.4 vs. - 5.0 ± 25.9 s, p < 0.0001). In 5 patients (3 in group 1 and 2 in group 2), initially targeted left PVs were not isolated despite complete vein occlusions, while they were by subsequent applications at the other ipsilateral PVs. CONCLUSIONS: In CB ablation, the order of targeting PVs highly influenced the TTI of the left PVs owing to the presence of electrical connections between left ipsilateral PVs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Congelamento , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
18.
J Interv Card Electrophysiol ; 63(2): 333-339, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33963960

RESUMO

PURPOSE: We aimed to elucidate the right atrial posterior wall (RAPW) and interatrial septum (IAS) conduction pattern during reverse typical atrial flutter (clockwise AFL: CW-AFL). METHODS: This study included 30 patients who underwent catheter ablation of CW-AFL (n = 11) and counter-clockwise AFL (CCW-AFL; n = 19) using an ultra-high resolution mapping system. RAPW transverse conduction block was evaluated by the conduction pattern on propagation maps and double potentials separated by an isoelectric line. The degree of blockade was evaluated by the %blockade, which was calculated by the length of the blocked area divided by the RAPW length. IAS activation patterns were also investigated dependent on the propagation map. RESULTS: The average %blockade of the RAPW was significantly smaller in patients with CW-AFL than those with CCW-AFL (25 [3-74]% vs. 67 [57-75]%, p < 0.05). CW-AFL patients exhibited 3 different RAPW conduction patterns: (1) a complete blockade pattern (3 patients), (2) moderate (> 25% blockade) blockade pattern (2 patients), and (3) little (< 25% blockade) blockade pattern (6 patients). In contrast, the little blockade pattern was not observed in CCW-AFL patients. Of 11 CW-AFL patients, 4, including all patients with an RAPW complete blockade pattern, had an IAS activation from the wavefront from the anterior tricuspid annulus (TA), and 6 had an IAS activation from the wavefronts from both the anterior TA and RAPW. One patient had IAS activation dominantly from the wavefront from the RAPW. CONCLUSIONS: RAPW transverse conduction blockade during CW-AFL was less frequent than during CCW-AFL, which possibly caused various IAS activation patterns.


Assuntos
Flutter Atrial , Ablação por Cateter , Arritmias Cardíacas/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/etiologia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Átrios do Coração/cirurgia , Bloqueio Cardíaco , Humanos
19.
J Interv Card Electrophysiol ; 64(2): 291-300, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33755817

RESUMO

BACKGROUND: A novel technology able to measure the local impedance (LI) during radiofrequency ablation has become available for clinical use. We investigated the change in the LI characteristics during superior vena cava isolations (SVCIs) using a novel catheter equipped with mini-electrodes. METHODS: Twenty paroxysmal atrial fibrillation patients (68 ± 9 years; 14 males) underwent an SVCI by targeting breakthroughs. Subsequently, dormant conduction provoked by adenosine triphosphate (ATP) was evaluated. RESULTS: Electrical SVCIs were successfully achieved in all with 7.2 ± 3.0 radiofrequency applications (RFA) without any complications. The procedure and fluoroscopic times were 13.1 ± 8.1 and 2.8 ± 2.3 min. No ablation was required at the anteroseptal SVC in 19 (95.0%) patients. The baseline LI and generator impedance (GI) were 125 ± 23 and 105 ± 14Ω. LI drops during RFA were significantly greater than GI drops (17 ± 12 vs. 4 ± 4Ω, p < 0.001). The correlation between the LI drops and GI drops was relatively high (R = 0.69, p < 0.001). LI drops were highest at the septal SVC and lowest at the lateral followed by antero-lateral SVC. The baseline electrogram amplitude between the mini-electrodes and tip-ring electrodes was 1.2 ± 1.4 and 0.8 ± 0.6 mV. The mini-electrode amplitude is more sharply attenuated with a greater magnitude than the tip-ring amplitude (p < 0.001). ATP-provoked dormant conduction was exposed in 10/17 (58.8%) patients and antero-lateral SVC gap locations in 7. Antero-lateral SVC LI drops were similar between patients with and without dormancy. CONCLUSIONS: The LI drop magnitude during RFA significantly differed among the SVC segments. Antero-lateral SVC ATP-provoked dormant conduction was often exposed, and additional applications are recommended following the isolation for a robust SVCI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Trifosfato de Adenosina , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Catéteres , Impedância Elétrica , Humanos , Masculino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
20.
J Interv Card Electrophysiol ; 63(1): 115-123, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33564988

RESUMO

PURPOSE: To elucidate the electrophysiological predictors of the intramural origins of left ventricular outflow tract-ventricular tachyarrhythmias (LVOT-VAs), and to clarify the involvement of anatomical factors. METHODS: Twenty-nine successfully ablated LVOT-VAs patients with origins in the aortomitral continuity (AMC) (n = 8), aortic sinus of valsalva (ASV) (n = 9), great cardiac vein (GCV) (n = 5), and intramural myocardium (n = 7) were enrolled. Intramural origins were defined as when effective ablation from AMC and epicardium (ASV and/or GCV) was needed. The local activation time difference (LATD) was calculated as follows: (earliest AMC activation) - (earliest epicardial activation), and was presented as an absolute value. Electrophysiological parameters and anatomical factors predisposing the intramural origins were investigated. RESULTS: LATD of intramural origins was significantly shorter than that of AMC and GCV (4.5 ± 2.6 vs. 12.1 ± 7.4 vs. 17.4 ± 4.7, P < 0.05), respectively. In multivariate logistic regression analysis, LATD was associated with intramural origins (odds ratio: 0.711, confidence interval: 0.514-0.985, P = 0.040). ROC analysis revealed LATD of 7 ms as cut-off value. In computed tomography analysis, some patients who had thick fat tissue below the GCV, and an unusual GCV running pattern might be misdiagnosed as intramural origins. CONCLUSION: LATD ≤ 7 ms was associated with intramural origins, but with some anatomical limitations.


Assuntos
Ablação por Cateter , Seio Coronário , Taquicardia Ventricular , Eletrocardiografia , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA