Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Microbiol Spectr ; 11(3): e0504422, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37212699

RESUMO

The COVID-19 pandemic has given rise to numerous commercially available antigen rapid diagnostic tests (Ag-RDTs). To generate and to share accurate and independent data with the global community requires multisite prospective diagnostic evaluations of Ag-RDTs. This report describes the clinical evaluation of the OnSite COVID-19 rapid test (CTK Biotech, CA, USA) in Brazil and the United Kingdom. A total of 496 paired nasopharyngeal (NP) swabs were collected from symptomatic health care workers at Hospital das Clínicas in São Paulo, Brazil, and 211 NP swabs were collected from symptomatic participants at a COVID-19 drive-through testing site in Liverpool, United Kingdom. Swabs were analyzed by Ag-RDT, and results were compared to quantitative reverse transcriptase PCR (RT-qPCR). The clinical sensitivity of the OnSite COVID-19 rapid test in Brazil was 90.3% (95% confidence interval [CI], 75.1 to 96.7%) and in the United Kingdom was 75.3% (95% CI, 64.6 to 83.6%). The clinical specificity in Brazil was 99.4% (95% CI, 98.1 to 99.8%) and in the United Kingdom was 95.5% (95% CI, 90.6 to 97.9%). Concurrently, analytical evaluation of the Ag-RDT was assessed using direct culture supernatant of SARS-CoV-2 strains from wild-type (WT), Alpha, Delta, Gamma, and Omicron lineages. This study provides comparative performance of an Ag-RDT across two different settings, geographical areas, and populations. Overall, the OnSite Ag-RDT demonstrated a lower clinical sensitivity than claimed by the manufacturer. The sensitivity and specificity from the Brazil study fulfilled the performance criteria determined by the World Health Organization, but the performance obtained from the UK study failed to do. Further evaluation of Ag-RDTs should include harmonized protocols between laboratories to facilitate comparison between settings. IMPORTANCE Evaluating rapid diagnostic tests in diverse populations is essential to improving diagnostic responses as it gives an indication of the accuracy in real-world scenarios. In the case of rapid diagnostic testing within this pandemic, lateral flow tests that meet the minimum requirements for sensitivity and specificity can play a key role in increasing testing capacity, allowing timely clinical management of those infected, and protecting health care systems. This is particularly valuable in settings where access to the test gold standard is often restricted.


Assuntos
COVID-19 , Humanos , Brasil , COVID-19/diagnóstico , Pandemias , Estudos Prospectivos , SARS-CoV-2 , Reino Unido , Biotecnologia , Teste para COVID-19
2.
Antibiotics (Basel) ; 11(11)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36358222

RESUMO

This study evaluates a possible correlation between multidrug-resistant Klebsiella pneumoniae strains and virulence markers in a Danio rerio (zebrafish) model. Whole-genome sequencing (WGS) was performed on 46 strains from three Brazilian hospitals. All of the isolates were colistin-resistant and harbored blaKPC-2. Ten different sequence types (STs) were found; 63% belonged to CC258, 22% to ST340, and 11% to ST16. The virulence factors most frequently found were type 3 fimbriae, siderophores, capsule regulators, and RND efflux-pumps. Six strains were selected for a time-kill experiment in zebrafish embryos: infection by ST16 was associated with a significantly higher mortality rate when compared to non-ST16 strains (52% vs. 29%, p = 0.002). Among the STs, the distribution of virulence factors did not differ significantly except for ST23, which harbored a greater variety of factors than other STs but was not related to a higher mortality rate in zebrafish. Although several virulence factors are described in K. pneumoniae, our study found ST16 to be the only significant predictor of a virulent phenotype in an animal model. Further research is needed to fully understand the correlation between virulence and sequence types.

3.
J Infect Dis ; 226(10): 1726-1730, 2022 11 11.
Artigo em Inglês | MEDLINE | ID: mdl-36134610

RESUMO

In this prospective cohort of 30 vaccinated healthcare workers with mild Omicron variant infection, we evaluated viral culture, rapid antigen test (RAT), and real-time reverse-transcription polymerase chain reaction (RT-PCR) of respiratory samples at days 5, 7, 10, and 14. Viral culture was positive in 46% (11/24) and 20% (6/30) of samples at days 5 and 7, respectively. RAT and RT-PCR (Ct ≤35) showed 100% negative predictive value (NPV), with positive predictive values (PPVs) of 32% and 17%, respectively, for predicting viral culture positivity. A lower RT-PCR threshold (Ct ≤24) improved culture prediction (PPV = 39%; NPV = 100%). Vaccinated persons with mild Omicron infection are potentially transmissible up to day 7. RAT and RT-PCR might be useful tools for shortening the isolation period.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Estudos Prospectivos , Pessoal de Saúde
4.
Artigo em Inglês | MEDLINE | ID: mdl-34586308

RESUMO

Mobile phones (MPs) have become an important work tool around the world including in hospitals. We evaluated whether SARS-CoV-2 can remain on the surface of MPs of first-line healthcare workers (HCW) and also the knowledge of HCWs about SARS-CoV-2 cross-transmission and conceptions on the virus survival on the MPs of HCWs. A cross-sectional study was conducted in the COVID-19 Intensive Care Unit of a teaching hospital. An educational campaign was carried out on cross-transmission of SARS-CoV-2, and its permanence in fomites, in addition to the proper use and disinfection of MPs. Herewith an electronic questionnaire was applied including queried conceptions about hand hygiene and care with MP before and after the pandemic. The MPs were swabbed with a nylon FLOQ Swab™, in an attempt to increase the recovery of SARS-CoV-2. All MP swab samples were subjected to SARS-CoV-2 RT-PCR; RT-PCR positive samples were subjected to viral culture in Vero cells (ATCC® CCL-81™). Fifty-one MPs were swabbed and a questionnaire on hand hygiene and the use and disinfection of MP was applied after an educational campaign. Most HCWs increased adherence to hand hygiene and MP disinfection during the pandemic. Fifty-one MP swabs were collected and two were positive by RT-PCR (4%), with Cycle threshold (Ct ) values of 34-36, however, the cultures of these samples were negative. Although most HCWs believed in the importance of cross-transmission and increased adherence to hand hygiene and disinfection of MP during the pandemic, SARS-CoV-2 RNA was detected in MPs. Our results suggest the need for a universal policy in infection control guidelines on how to care for electronic devices in hospital settings.


Assuntos
COVID-19 , Telefone Celular , Animais , Chlorocebus aethiops , Estudos Transversais , Hospitais , Humanos , RNA Viral , SARS-CoV-2 , Células Vero
5.
Am J Infect Control ; 49(4): 512-515, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33080363

RESUMO

This study assessed the disinfection using 70% ethanol; H2O2-quaternary ammonium salt mixture; 0.1% sodium hypochlorite and autoclaving of four 3D-printed face shields with different designs, visor materials; and visor thickness (0.5-0.75 mm). We also investigated their clinical suitability by applying a questionnaire to health workers (HW) who used them. Each type of disinfection was done 40 times on each type of mask without physical damage. In contrast, autoclaving led to appreciable damage.


Assuntos
COVID-19/prevenção & controle , Desinfetantes/farmacologia , Desinfecção/métodos , Equipamento de Proteção Individual/virologia , Impressão Tridimensional , SARS-CoV-2 , COVID-19/epidemiologia , Coleta de Dados , Desenho de Equipamento , Etanol/farmacologia , Pessoal de Saúde , Humanos , Peróxido de Hidrogênio/farmacologia , Hipoclorito de Sódio/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA