Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Radiat Oncol ; 10: 213, 2015 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-26499318

RESUMO

BACKGROUND: Exploiting biologic imaging, studies have been performed to boost dose to gross intraprostatic tumor volumes (GTV) while reducing dose elsewhere in the prostate. Interest in proton beams has increased due to superior normal-tissue sparing they afford. Our goal was to dosimetrically compare 3D conformal proton boost plans with intensity-modulated radiation therapy (IMRT) plans with respect to target coverage and avoiding organs at risk. METHODS: Treatment planning computer tomography scans of ten patients were selected. For each patient, two hypothetical but realistic GTVs each with a fixed volume were contoured in different anatomical locations of the prostate. IMRT and proton beam plans were created with a prescribed dose of 50.4 Gy to the initial planning target volume (PTV) including the PTV of the seminal vesicles (PSV), 70.2 Gy to the PTV of the prostate (PPS), and 90 Gy to the PTV of the gross tumor volumes (PGTVs). For proton plans, uncertainties of range and patient setup were accounted for; apertures were adjusted until the dose-volume coverage of PTVs matched that of the IMRT plan. For both plans, prescribed PTV doses were made identical to allow for comparing normal-tissue doses. RESULTS: Protons delivered more homogeneous but less conformal doses to PGTVs than IMRT did and comparable doses to PSV and PPS. Volumes of bladder and rectum receiving doses higher than 65 Gy were similar for both plans. However, volumes receiving less than 65 Gy were significantly reduced, i.e., protons reduced integral dose by 45.6 % and 26.5 % for rectum and bladder, respectively. This volume-sparing was also seen in femoral heads and penile bulb. CONCLUSIONS: Protons delivered comparable doses to targets in dose homogeneity and conformity and spared normal tissues from intermediate-to-low doses better than IMRT did. Further improvement of dose sparing and changes in homogeneity and conformity may be achieved by reducing proton range uncertainties and from implementing intensity modulation.


Assuntos
Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Dosagem Radioterapêutica
2.
J Gastrointest Oncol ; 6(2): 108-14, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25830030

RESUMO

BACKGROUND: Pancreatic cancer is a highly aggressive malignancy. Chemoradiotherapy (CRT) is utilized in many cases to improve locoregional control; however, toxicities associated with radiation can be significant given the location of the pancreas. RTOG 0848 seeks to evaluate chemoradiation using either intensity-modulated radiation therapy (IMRT) or 3D conformal photon radiotherapy (3DCRT) modalities as an adjuvant treatment. The purpose of this study is to quantify the dosimetric changes seen when using IMRT or 3D CRT photon modalities, as well as proton radiotherapy, in patients receiving CRT for cancer of the pancreas treated per RTOG 0848 guidelines. MATERIALS: Ten patients with pancreatic head adenocarcinoma treated between 2010 and 2013 were evaluated in this study. All patients were simulated with contrast-enhanced CT imaging. Separate treatment plans using IMRT and 3DCRT as well as proton radiotherapy were created for each patient. All planning volumes were created per RTOG 0848 protocol. Dose-volume histograms (DVH) were calculated and analyzed in order to compare plans between the three modalities. The organs at risk (OAR) evaluated in this study are the kidneys, liver, small bowel, and spinal cord. RESULTS: There was no difference between the IMRT and 3DCRT plans in dose delivered to the kidneys, liver, or bowel. The proton radiotherapy plans were found to deliver lower mean total kidney doses, mean liver doses, and liver D1/3 compared to the IMRT plans. The proton plans also gave less mean liver dose, liver D1/3, bowel V15, and bowel V50 in comparison to the 3DCRT. CONCLUSIONS: For patients receiving radiotherapy per ongoing RTOG 0848 for pancreatic cancer, there was no significant difference in normal tissue sparing between IMRT and 3DCRT treatment planning. Therefore, the choice between the two modalities should not be a confounding factor in this study. The proton plans also demonstrated improved OAR sparing compared to both IMRT and 3DCRT treatment plans.

3.
Cancers (Basel) ; 6(4): 2356-68, 2014 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-25489937

RESUMO

Background. While neoadjuvant concurrent chemoradiotherapy has improved outcomes for esophageal cancer patients, surgical complication rates remain high. The most frequent perioperative complications after trimodality therapy were cardiopulmonary in nature. The radiation modality utilized can be a strong mitigating factor of perioperative complications given the location of the esophagus and its proximity to the heart and lungs. The purpose of this study is to make a dosimetric comparison of Intensity-Modulated Radiation Therapy (IMRT), proton and 3D conformal radiotherapy (3D-CRT) with regard to reducing perioperative cardiopulmonary complications in esophageal cancer patients. Materials. Ten patients with esophageal cancer treated between 2010 and 2013 were evaluated in this study. All patients were simulated with contrast-enhanced CT imaging. Separate treatment plans using proton radiotherapy, IMRT, and 3D-CRT modalities were created for each patient. Dose-volume histograms were calculated and analyzed to compare plans between the three modalities. The organs at risk (OAR) being evaluated in this study are the heart, lungs, and spinal cord. To determine statistical significance, ANOVA and two-tailed paired t-tests were performed for all data parameters. Results. The proton plans showed decreased dose to various volumes of the heart and lungs in comparison to both the IMRT and 3D-CRT plans. There was no difference between the IMRT and 3D-CRT plans in dose delivered to the lung or heart. This finding was seen consistently across the parameters analyzed in this study. Conclusions. In patients receiving radiation therapy for esophageal cancer, proton plans are technically feasible while achieving adequate coverage with lower doses delivered to the lungs and cardiac structures. This may result in decreased cardiopulmonary toxicity and less morbidity to esophageal cancer patients.

4.
Phys Med Biol ; 54(16): N367-74, 2009 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-19636083

RESUMO

Electron monitor unit (MU) calculation requires measured beam data such as the relative output factor (ROF) of a cone, insert correction factor (ICF) and effective source-to-surface distance (ESD). Measuring the beam data to cover all possible clinical cases is not practical for a busy clinic because it takes tremendous time and labor. In this study, we propose a practical approach to reduce the number of data measurements without affecting accuracy. It is based on two findings of dosimetric properties of electron beams. One is that the output ratio of two inserts is independent of the cone used, and the other is that ESD is a function of field size but independent of cone and jaw opening. For the measurements to prove the findings, a parallel plate ion chamber (Markus, PTW 23343) with an electrometer (Cardinal Health 35040) was used. We measured the outputs to determine ROF, ICF and ESD of different energies (5-21 MeV). Measurements were made in a Plastic Water phantom or in water. Three linear accelerators were used: Siemens MD2 (S/N 2689), Siemens Primus (S/N 3305) and Varian Clinic 21-EX (S/N 1495). With these findings, the number of data set to be measured can be reduced to less than 20% of the data points.


Assuntos
Elétrons , Radiometria/métodos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA