RESUMO
Background: The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) has recently introduced a consensus document that outlines risk factors to identify high bleeding risk (HBR) in patients undergoing transcatheter aortic valve replacement (TAVR). The objective of the present study was to evaluate the prevalence and predictive value of the VARC-HBR definition in a contemporary, large-scale TAVR population. Methods: Multicenter study including 10,449 patients undergoing TAVR. Based on consensus, twenty-one clinical and laboratory criteria were identified and classified as major or minor. Patients were stratified as at low, moderate, high, and very high bleeding risk according to VARC-HBR definition. The primary endpoint was the rate of BARC type 3 or 5 bleeding at 1 year, defined as the composite of peri-procedural (within 30 days) or late (after 30 days) bleeding. Results: Patients with at least one VARC-HBR criterion (n=9,267, 88.7%) had a higher risk of BARC 3 or 5 bleeding, proportional to the severity of risk assessment (10.8%, 16.1%, and 24.6% for moderate, high, and very high-risk groups, respectively). However, a comparable rate of bleeding events was observed in the low-risk and moderate-risk groups. The area under ROC curve was 0.58. Patients with VARC-HBR criteria also exhibited a gradual increase in 1-year all-cause mortality, with an up to 2-fold increased mortality risk for high and very high-risk groups (HR: 1.33, 95% CI: 1.04-1.70; and HR: 1.97, 95% CI: 1.53-2.53, respectively). Conclusions: The VARC-HBR consensus offered a pragmatic approach to guide bleeding risk stratification in TAVR. The results of the present study would support the predictive validity of the newly definition and promote its application in clinical practice to minimize bleeding risk and improve patient outcomes.
RESUMO
BACKGROUND: The occurrence of conduction disturbances (CDs) remains the most frequent complication of transcatheter aortic valve replacement (TAVR). However, little is known about the timing of electrocardiogram (ECG) changes and CDs during the TAVR procedure. OBJECTIVE: The objective of this study was to describe ECG changes throughout the TAVR procedure using the CARA monitor. METHODS: This was a multicenter study including 196 prospectively enrolled patients without preexisting CDs undergoing TAVR. All patients were monitored with the CARA system, which uses a 12-lead ECG to measure PQ and QRS intervals, QRS axis, and variations with each heartbeat at every step: baseline, wire insertion, pre-dilatation, valve deployment, post-dilatation, and end of procedure. RESULTS: PQ and QRS intervals progressively increased throughout the procedure, with a cumulative increase from 169.2 ± 20.0 ms to 186.0 ± 31.6 ms (P < .001) for the PQ interval and from 101.3 ± 10.5 ms to 126.0 ± 25.4 ms (P < .001) for the QRS interval, from baseline to the end of the procedure. A significant increase in the number of patients with left axis deviation was observed (7.7% at baseline vs 31.8% at end of procedure; P < .001). A total of 161 (82.1%) patients exhibited at least 1 CD episode (PQ >200 ms, QRS ≥120 ms, advanced heart block) during the procedure, with most episodes occurring during pre-dilatation and valve implantation maneuvers. CONCLUSION: The CARA system facilitated real-time ECG monitoring, detecting subtle and progressive changes during TAVR. ECG changes occurred at each step, with most patients experiencing CDs, especially during pre-dilatation and valve implantation. The potential clinical impact of monitoring ECG dynamics and timing for early detection of severe CDs should be explored in future studies.
RESUMO
INTRODUCTION AND OBJECTIVES: Percutaneous left atrial appendage closure (LAAC) has emerged as a nonpharmacological alternative for the prevention of thromboembolic events in patients with nonvalvular atrial fibrillation. However, there are few data on readmissions after LACC. The aim of this study was to determine the rate of early (≤ 30 days) and late (31-365 days) readmission after LAAC, and to assess the predictors and clinical impact of rehospitalization. METHODS: This multicenter study included 1419 consecutive patients who underwent LAAC. The median follow-up was 33 [17-55] months, and follow-up was complete in all but 54 (3.8%) patients. The primary endpoint was readmissions for any cause. Logistic regression and Cox regression analysis were performed to determine the predictors of readmission and its clinical impact. RESULTS: A total of 257 (18.1%) patients were readmitted within the first year after LAAC (3.2% early, 14.9% late). The most common causes of readmission were bleeding (24.5%) and heart failure (20.6%). A previous gastrointestinal bleeding event was associated with a higher risk of early readmission (OR, 2.65; 95%CI, 1.23-5.71). The factors associated with a higher risk of late readmission were a lower body mass index (HR, 0.96-95%CI, 0.93-0.99), diabetes (HR, 1.38-95%CI, 1.02-1.86), chronic kidney disease (HR, 1.60; 95%CI, 1.21-2.13), and previous heart failure (HR, 1.69; 95%CI, 1.26-2.27). Both early (HR, 2.12-95%CI, 1.22-3.70) and late (HR, 1.75; 95%CI, 1.41-2.17) readmissions were associated with a higher risk of 2-year mortality. CONCLUSIONS: Readmissions within the first year after LAAC were common, mainly related to bleeding and heart failure events, and associated with patients' comorbidity burden. Readmission after LAAC confered a higher risk of mortality during the first 2 years after the procedure.
RESUMO
Background: A blood multimarker approach may be useful to enhance risk stratification in patients undergoing TAVI. Objectives: The objective of this study was to determine the prognostic value of multiple blood biomarkers in transcatheter aortic valve implantation (TAVI) patients. Methods: In this prospective study, several blood biomarkers of cardiovascular function, inflammation, and renal function were measured in 362 patients who underwent TAVI. The cohort was divided into 3 groups according to the number of elevated blood biomarkers (ie, ≥ median value for the whole cohort) for each patient before the procedure. Survival analyses were conducted to evaluate the association between blood biomarkers and risk of adverse event following TAVI. Results: During a median follow-up of 2.5 (IQR: 1.9-3.2) years, 34 (9.4%) patients were rehospitalized for heart failure, 99 (27%) patients died, and 113 (31.2%) met the composite endpoint of all-cause mortality or heart failure rehospitalization. Compared to patients with 0 to 3 elevated biomarkers (referent group), those with 4 to 7 and 8 to 9 elevated biomarkers had a higher risk of all-cause mortality (HR: 1.54 [95% CI: 0.84-2.80], P = 0.16, and HR: 2.81 [95% CI: 1.53-5.15], P < 0.001, respectively) and of the composite endpoint (HR: 1.65 [95% CI: 0.95-2.84], P = 0.07, and HR: 2.67 [95% CI: 1.52-4.70] P < 0.001, respectively). Moreover, adding the number of elevated blood biomarkers into the clinical multivariable model provided significant incremental predictive value for all-cause mortality (Net Reclassification Index = 0.71, P < 0.001). Conclusions: An increasing number of elevated blood biomarkers is associated with higher risks of adverse clinical outcomes following TAVI. The blood multimarker approach may be helpful to enhance risk stratification in TAVI patients.
RESUMO
BACKGROUND: Little is known about the occurrence of subclinical new-onset atrial fibrillation (NOAF) after transcatheter aortic valve implantation (TAVI). AIMS: We aimed to evaluate the incidence, predictors, and clinical impact of subclinical NOAF after TAVI. METHODS: This was a multicentre study, including patients with aortic stenosis (AS) and no previous atrial fibrillation undergoing TAVI, with continuous ambulatory electrocardiogram (AECG) monitoring after TAVI. RESULTS: A total of 700 patients (79±8 years, 49% female, Society of Thoracic Surgeons score 2.9% [1.9-4.0]) undergoing transarterial TAVI were included (85% balloon-expandable valves). AECG was started 1 (0-1) day after TAVI (monitoring time: 14121314 days). NOAF was detected in 49 patients (7%), with a median duration of 185 (43-421) minutes (atrial fibrillation burden of 0.7% [0.3-2.8]). Anticoagulation was started in 25 NOAF patients (51%). No differences were found in baseline or procedural characteristics, except for a higher AS severity in the NOAF group (peak gradient: no NOAF: 71.9±23.5 mmHg vs NOAF: 85.2±23.8 mmHg; p=0.024; mean gradient: no NOAF: 44.4±14.7 mmHg vs NOAF: 53.8±16.8 mmHg; p=0.004). In the multivariable analysis, the baseline mean transaortic gradient was associated with a higher risk of NOAF after TAVI (odds ratio 1.04, 95% confidence interval: 1.01-1.06 for each mmHg; p=0.006). There were no differences between groups in all-cause mortality (no NOAF: 4.7% vs NOAF: 0%; p=0.122), stroke (no NOAF: 1.4% vs NOAF: 2.0%; p=0.723), or bleeding (no NOAF: 1.9% vs NOAF: 4.1%; p=0.288) from the 30-day to 1-year follow-up. CONCLUSIONS: NOAF detected with AECG occurred in 7% of TAVI recipients and was associated with a higher AS severity. NOAF detection determined the start of anticoagulation therapy in about half of the patients, and it was not associated with an increased risk of clinical events at 1-year follow-up.
Assuntos
Estenose da Valva Aórtica , Fibrilação Atrial , Eletrocardiografia Ambulatorial , Substituição da Valva Aórtica Transcateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia Ambulatorial/métodos , Fatores de Risco , Resultado do TratamentoRESUMO
INTRODUCTION AND OBJECTIVES: In patients undergoing percutaneous coronary intervention (PCI) in the workup pre-transcatheter aortic valve replacement (TAVR), the clinical impact of coronary revascularization complexity remains unknown. This study sought to examine the impact of PCI complexity on clinical outcomes after TAVR in patients undergoing PCI in the preprocedural workup. METHODS: This was a multicenter study including consecutive patients scheduled for TAVR with concomitant significant coronary artery disease. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥ 3 stents implanted, ≥ 3 lesions treated, bifurcation with 2 stents implanted, total stent length >60mm, or chronic total occlusion. The rates of major adverse cardiac events (MACE), including cardiovascular mortality, myocardial infarction, and coronary revascularization were evaluated. RESULTS: A total of 1550 patients were included, of which 454 (29.3%) underwent complex PCI in the pre-TAVR workup. After a median follow-up period of 2 [1-3] years after TAVR, the incidence of MACE was 9.6 events per 100 patients-years. Complex PCI significantly increased the risk of cardiac death (HR, 1.44; 95%CI, 1.01-2.07), nonperiprocedural myocardial infarction (HR, 1.52; 95%CI, 1.04-2.21), and coronary revascularization (HR, 2.46; 95%CI, 1.44-4.20). In addition, PCI complexity was identified as an independent predictor of MACE after TAVR (HR, 1.31; 95%CI, 1.01-1.71; P=.042). CONCLUSIONS: In TAVR candidates with significant coronary artery disease requiring percutaneous treatment, complex revascularization was associated with a higher risk of MACE. The degree of procedural complexity should be considered a strong determinant of prognosis in the PCI-TAVR population.
RESUMO
Right ventricular (RV) failure remains the strongest determinant of survival in pulmonary hypertension (PH). We aimed to identify relevant mechanisms, beyond pressure overload, associated with maladaptive RV hypertrophy in PH. To separate the effect of pressure overload from other potential mechanisms, we developed in pigs two experimental models of PH (M1, by pulmonary vein banding and M2, by aorto-pulmonary shunting) and compared them with a model of pure pressure overload (M3, pulmonary artery banding) and a sham-operated group. Animals were assessed at 1 and 8 months by right heart catheterization, cardiac magnetic resonance and blood sampling, and myocardial tissue was analyzed. Plasma unbiased proteomic and metabolomic data were compared among groups and integrated by an interaction network analysis. A total of 33 pigs completed follow-up (M1, n = 8; M2, n = 6; M3, n = 10; and M0, n = 9). M1 and M2 animals developed PH and reduced RV systolic function, whereas animals in M3 showed increased RV systolic pressure but maintained normal function. Significant plasma arginine and histidine deficiency and complement system activation were observed in both PH models (M1&M2), with additional alterations to taurine and purine pathways in M2. Changes in lipid metabolism were very remarkable, particularly the elevation of free fatty acids in M2. In the integrative analysis, arginine-histidine-purines deficiency, complement activation, and fatty acid accumulation were significantly associated with maladaptive RV hypertrophy. Our study integrating imaging and omics in large-animal experimental models demonstrates that, beyond pressure overload, metabolic alterations play a relevant role in RV dysfunction in PH.
Assuntos
Modelos Animais de Doenças , Hipertensão Pulmonar , Hipertrofia Ventricular Direita , Metabolômica , Proteômica , Animais , Hipertensão Pulmonar/metabolismo , Hipertensão Pulmonar/fisiopatologia , Hipertensão Pulmonar/diagnóstico por imagem , Hipertrofia Ventricular Direita/metabolismo , Hipertrofia Ventricular Direita/fisiopatologia , Hipertrofia Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Remodelação Ventricular , Sus scrofa , Suínos , MasculinoRESUMO
The growing number of candidates for transcatheter aortic valve replacement (TAVR) has increased the interest in the concomitant presence of coronary artery disease (CAD) and severe aortic stenosis (AS), prompting the need to define the appropriate revascularization strategy for each case. The reported prevalence of concurrent AS and CAD has varied over the years on the basis of the CAD definition and the population evaluated. Revascularization for treating CAD in patients with severe AS involves additional interventions that could impact outcomes. The addition of coronary artery bypass grafting (CABG) to surgical aortic valve replacement (SAVR) has demonstrated favourable effects on long-term prognosis, while the impact of adding percutaneous coronary intervention (PCI) to TAVR may depend on the CAD complexity and the feasibility of achieving complete or reasonably incomplete revascularization. Furthermore, the comparison between SAVR+CABG and TAVR+PCI in low-intermediate surgical risk and low-intermediate complex CAD patients did not reveal differences in all-cause mortality or stroke between the groups. However, there is some evidence showing a lower incidence of major cardiovascular events with the SAVR+CABG strategy for patients with complex CAD. Thus, SAVR+CABG seems to be the best option for patients with low-intermediate surgical risk and complex CAD, and TAVR+PCI for high surgical risk patients seeking complete and/or reasonable incomplete revascularization. After deciding between TAVR+PCI or SAVR+CABG, factors such as timing for PCI, low ejection fraction, coronary reaccess, and valve durability must be considered. Finally, alternative methods for assessing CAD severity are currently under evaluation to ascertain their real value for guiding revascularization in patients with severe AS with CAD.
Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fatores de RiscoRESUMO
INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.
RESUMO
INTRODUCTION: Small aortic annulus (SAA) poses a challenge in the management of patients with severe aortic stenosis requiring aortic valve replacement - both surgical and transcatheter - since it has been associated with worse clinical outcomes. AREAS COVERED: This review aims to comprehensively summarize the available evidence regarding the management of aortic stenosis in patients with SAA and discuss the current controversies as well as future perspectives in this field. EXPERT OPINION: It is paramount to agree in a common definition for diagnosing and properly treating SAA patients, and for that purpose, multidetector computer tomography is essential. The results of recent trials led to the expansion of transcatheter aortic valve replacement among patients of all the surgical-risk spectrum, and the choice of treatment (transcatheter, surgical) should be based on patient comorbidities, anatomical characteristics, and patient preferences.
Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Desenho de PróteseRESUMO
BACKGROUND: Data comparing valve systems in the valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) field have been obtained from retrospective studies. OBJECTIVES: The authors sought to compare the 1-year hemodynamic performance and clinical outcomes between balloon-expandable valves (BEV) SAPIEN 3/ULTRA (Edwards Lifesciences) and self-expanding valves (SEV) Evolut R/PRO/PRO+ (Medtronic) in ViV-TAVR. METHODS: Patients with a failed small (≤23 mm) surgical valve undergoing ViV-TAVR were randomized to receive a SEV or a BEV. Patients had a clinical and valve hemodynamic (Doppler echocardiography) evaluation at 1-year follow-up. Study outcomes were defined according to VARC-2/VARC-3 criteria. Intended performance of the valve was defined as mean gradient <20 mm Hg, peak velocity <3 m/s, Doppler velocity index ≥0.25 and less than moderate AR. RESULTS: A total of 98 patients underwent ViV-TAVR (46 BEV, 52 SEV). At 1-year follow-up, patients receiving a SEV had a lower mean transaortic gradient (22 ± 8 mm Hg BEV vs 14 ± 7 mm Hg SEV; P < 0.001), and a higher rate of intended valve performance (BEV: 30%, SEV:76%; P < 0.001). There were no cases of greater than mild aortic regurgitation. There were no differences in functional status (NYHA functional class >II, BEV: 7.3%, SEV: 4.1%; P = 0.505) or quality of life (Kansas City Cardiomyopathy Questionnaire, BEV: 77.9 ± 21.2, SEV: 81.8 ± 14.8; P = 0.334). No differences in all-cause mortality (BEV: 6.5%, SEV: 3.8; P = 0.495), heart failure hospitalization (BEV: 6.5%, SEV: 1.9%; P = 0.214), stroke (BEV: 0%, SEV: 1.9%; P = 0.369), myocardial infarction (BEV: 0%, SEV: 1.9%; P = 0.347), or pacemaker implantation (BEV: 2.2%, SEV: 1.9%; P = 0.898) were found. CONCLUSIONS: In patients who underwent ViV-TAVR for failed small aortic bioprostheses, those receiving a SEV exhibited a better valve hemodynamic profile at 1-year follow-up. There were no differences between SEV and BEV regarding functional status, quality of life, or clinical outcomes.
Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Desenho de PróteseRESUMO
BACKGROUND: The updated Valve Academic Research Consortium (VARC) definition for bleeding events after transcatheter aortic valve replacement (TAVR) lacks of clinical validation. OBJECTIVES: The aim of this study was to determine the incidence, predictors, and clinical impact of bleeding events following TAVR as defined by recent VARC-3 criteria. METHODS: A total of 2,384 consecutive patients with severe symptomatic aortic stenosis undergoing TAVR were included. Early (at index hospitalization) and late (after hospital discharge) bleeding complications were defined according to VARC-3 criteria as type 1, 2, 3, or 4. Baseline, procedural, and follow-up (24 [IQR: 12-43] months) data were prospectively collected. RESULTS: Bleeding events occurred in 761 patients (31.9%): types 1, 2, 3, and 4 in 169 (22.2%), 399 (52.4%), 149 (19.6%), and 44 (5.8%) patients, respectively. The primary vascular access site and gastrointestinal locations were the most common bleeding sources among early and late bleeding events, respectively. Female sex, thoracotomy access, larger (14-F) sheath use, and dual antiplatelet therapy determined an increased risk of early bleeding events (P < 0.02 for all). The use of the radial artery for secondary access was associated with a significant risk reduction of early bleeding (P < 0.001). Type 2 and type 3 events were associated with an increased mortality risk at 30-day (HR: 2.94 [95% CI: 1.43-6.03; P = 0.003] and HR: 4.91 [95% CI: 2.19-11.03; P < 0.001], respectively) and 1-year (HR: 1.86 [95% CI: 1.28-2.69; P = 0.001] and HR: 2.28 [95% CI: 1.41-3.66; P = 0.001], respectively) follow-up. A similar prognostic pattern was observed when applying VARC-2 criteria but with a much lower global incidence of early bleeding events (19% vs 27%; P < 0.001). CONCLUSIONS: Bleeding events after TAVR were associated with poorer short- and long-term survival. The magnitude of this correlation was proportional to bleeding severity defined according to VARC-3 criteria. Further studies on bleeding prevention following TAVR are warranted to improve procedural safety and patient prognosis.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Prognóstico , Incidência , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Medição de Risco , Hemorragia/epidemiologia , Hemorragia/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgiaRESUMO
Assessment of frailty before heart transplant (HT) is recommended but is not standard in most HT protocols. Our objective was to evaluate frailty at inclusion in HT list and during follow-up and to assess the influence of baseline frailty on prognosis. A prospective multicenter study in all adults included in the nonurgent HT waiting list. Frailty was defined as Fried's frailty phenotype score ≥3. Mean follow-up was 25.9 ± 1.2 months. Of 99 patients (mean age 54.8 [43.1 to 62.5] years, 70 men [70.7%]), 28 were frail (28.3%). A total of 85 patients received HT after 0.5 ± 0.01 years. Waiting time was shorter in frail patients (0.6 years [0.3 to 0.8] vs 0.2 years [0.1 to 0.4], p = 0.001) because of an increase in priority. Baseline frailty was not associated with overall mortality, (hazard ratio 0.99 [95% confidence interval 0.41 to 2.37, p = 0.98]). A total of 16 transplant recipients died (18.8%). Of the remaining 69 HT recipients, 65 underwent frailty evaluation during follow-up. Patients without baseline frailty (n = 49) did not develop it after HT. Of 16 patients with baseline frailty, only 2 were still frail at the end of follow-up. Frailty is common in HT candidates but is reversible in most cases after HT and is not associated with post-transplant mortality. Our results suggest that frailty should not be considered an exclusion criterion for HT.
Assuntos
Fragilidade , Transplante de Coração , Masculino , Adulto , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Fragilidade/epidemiologia , Modelos de Riscos Proporcionais , Listas de EsperaRESUMO
INTRODUCTION AND OBJECTIVES: To evaluate the prevalence, clinical characteristics, and outcomes of patients with angina undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. METHODS: A total of 1687 consecutive patients with severe aortic stenosis undergoing TAVR at our center were included and classified according to patient-reported angina symptoms prior to the TAVR procedure. Baseline, procedural and follow-up data were collected in a dedicated database. RESULTS: A total of 497 patients (29%) had angina prior to the TAVR procedure. Patients with angina at baseline showed a worse New York Heart Association (NYHA) functional class (NYHA class> II: 69% vs 63%; P=.017), a higher rate of coronary artery disease (74% vs 56%; P <.001), and a lower rate of complete revascularization (70% vs 79%; P <.001). Angina at baseline had no impact on all-cause mortality (HR, 1.02; 95%CI, 0.71-1.48; P=.898) and cardiovascular mortality (HR, 1.2; 95%CI, 0.69-2.11; P=.517) at 1 year. However, persistent angina at 30 days post-TAVR was associated with increased all-cause mortality (HR, 4.86; 95%CI, 1.71-13.8; P=.003) and cardiovascular mortality (HR, 20.7; 95%CI, 3.50-122.6; P=.001) at 1-year follow-up. CONCLUSIONS: More than one-fourth of patients with severe aortic stenosis undergoing TAVR had angina prior to the procedure. Angina at baseline did not appear to be a sign of a more advanced valvular disease and had no prognostic impact; however, persistent angina at 30 days post-TAVR was associated with worse clinical outcomes.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Prognóstico , Angina Pectoris/epidemiologia , Angina Pectoris/etiologia , Angina Pectoris/cirurgia , Valva Aórtica/cirurgia , Índice de Gravidade de DoençaRESUMO
BACKGROUND: The Valve Academic Research Consortium (VARC)-3 definition for myocardial injury after transcatheter aortic valve replacement (TAVR) lacks of clinical validation. OBJECTIVES: This study sought to determine the incidence, predictors, and clinical impact of periprocedural myocardial injury (PPMI) following TAVR as defined by recent VARC-3 criteria. METHODS: We included 1,394 consecutive patients who underwent TAVR with a new-generation transcatheter heart valve. High-sensitivity troponin levels were assessed at baseline and within 24 hours after the procedure. PPMI was defined according to VARC-3 criteria as an increase ≥70 times in troponin levels (vs ≥15 times according to the VARC-2 definition). Baseline, procedural, and follow-up data were prospectively collected. RESULTS: PPMI was diagnosed in 193 (14.0%) patients. Female sex and peripheral artery disease were independent predictors of PPMI (P < 0.01 for both). PPMI was associated with a higher risk of mortality at 30-day (HR: 2.69, 95% CI: 1.50-4.82; P = 0.001) and 1-year (for all-cause mortality, HR: 1.54; 95% CI: 1.04-2.27; P = 0.032; for cardiovascular mortality, HR: 3.04; 95% CI: 1.68-5.50; P < 0.001) follow-up. PPMI according to VARC-2 criteria had no impact on mortality. CONCLUSIONS: About 1 out of 10 patients undergoing TAVR in the contemporary era had PPMI as defined by recent VARC-3 criteria, and baseline factors like female sex and peripheral artery disease determined an increased risk. PPMI had a negative impact on early and late survival. Further studies on the prevention of PPMI post-TAVR and implementing measures to improve outcomes in PPMI patients are warranted.
Assuntos
Traumatismos Cardíacos , Doença Arterial Periférica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Catéteres , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologiaRESUMO
Transcatheter aortic valve replacement (TAVR) has gained over time a major reduction in procedural complications. Despite this, clinically relevant bleeding still occurs in a non-negligible proportion of patients and adversely affects prognosis. Patients with severe aortic stenosis are at heightened risk for spontaneous bleeding due to advanced age and a high comorbidity burden. Also, procedural factors and antithrombotic management contribute to define individual bleeding susceptibility. Bleeding prevention represents an emerging area for improving patient care. Because of the tight hemorrhagic/ischemic balance, a tailored approach based on individual bleeding-risk profile, such as a less invasive antithrombotic regimen or appropriate diagnostic preprocedural evaluation, should be pursued to avoid bleeding events. This review aims to provide an in-depth overview of bleeding events in the TAVR field, including definitions, timing and the extent of risk, and clinical impact, as well as updates on antithrombotic management and its potential influence on bleeding complications.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fibrinolíticos/uso terapêutico , Fatores de Risco , Resultado do Tratamento , Hemorragia/epidemiologia , Hemorragia/etiologia , Hemorragia/tratamento farmacológico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/tratamento farmacológico , Valva Aórtica/cirurgiaRESUMO
BACKGROUND: No data exist on the clinical and prognostic significance of syncope in patients undergoing transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. METHODS: A total of 1705 consecutive patients with severe aortic stenosis undergoing TAVR in a tertiary university centre between 2007 and 2021 were included and classified according to the presence of syncope before the TAVR procedure. Baseline, procedural, and follow-up data were collected prospectively in a dedicated database. RESULTS: A total of 115 patients (7%) presented with syncope before the TAVR procedure. Of these, 15 patients (13%) showed arrhythmic episodes as the probable cause of the syncope, and all of them had pacemakers implanted at a median of 13 (6 to 53) days before the TAVR procedure. Patients with syncope were older (82 ± 8 years vs 80 ± 8 years, P = 0.001) and had a higher rate of pacemaker implantation before the TAVR procedure (27% vs 14%, P < 0.001), with no differences between groups regarding the severity of aortic stenosis (transvalvular gradient, valve area). There were no differences between groups in 30-day (adjusted hazard ratio [HR], 1.28; 95% confidence interval [CI], 0.46-3.60) and 1-year (adjusted HR, 0.71; 95% CI, 0.0.35-1.45) mortality following TAVR. CONCLUSIONS: Syncope was not associated with a more advanced valvular disease and had no significant prognostic impact on patients undergoing TAVR. However, arrhythmias and conduction-system disturbances were more common in patients with previous syncope and might play a relevant role in the pathogenesis of syncope in patients with aortic stenosis.
Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Fatores de Risco , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Prognóstico , Valva Aórtica/cirurgia , Índice de Gravidade de DoençaAssuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Hospitais , AlemanhaRESUMO
AIMS: Pulmonary hypertension (PH) associated with left heart disease is an increasingly prevalent problem, orphan of targeted therapies, and related to a poor prognosis, particularly when pre- and post-capillary PH combine. The current study aimed to determine whether treatment with the selective ß3 adrenoreceptor agonist mirabegron improves outcomes in patients with combined pre- and post-capillary PH (CpcPH). METHODS AND RESULTS: The ß3 Adrenergic Agonist Treatment in Chronic Pulmonary Hypertension Secondary to Heart Failure (SPHERE-HF) trial is a multicentre, randomized, parallel, placebo-controlled clinical trial that enrolled stable patients with CpcPH associated with symptomatic heart failure. A total of 80 patients were assigned to receive mirabegron (50 mg daily, titrated till 200 mg daily, n = 39) or placebo (n = 41) for 16 weeks. Of them, 66 patients successfully completed the study protocol and were valid for the main analysis. The primary endpoint was the change in pulmonary vascular resistance (PVR) on right heart catheterization. Secondary outcomes included the change in right ventricular (RV) ejection fraction by cardiac magnetic resonance or computed tomography, other haemodynamic variables, functional class, and quality of life. The trial was negative for the primary outcome (placebo-corrected mean difference of 0.62 Wood units, 95% confidence interval [CI] -0.38, 1.61, p = 0.218). Patients receiving mirabegron presented a significant improvement in RV ejection fraction as compared to placebo (placebo-corrected mean difference of 3.0%, 95% CI 0.4, 5.7%, p = 0.026), without significant differences in other pre-specified secondary outcomes. CONCLUSIONS: SPHERE-HF is the first clinical trial to assess the potential benefit of ß3 adrenergic agonists in PH. The trial was negative since mirabegron did not reduce PVR, the primary endpoint, in patients with CpcPH. On pre-specified secondary outcomes, a significant improvement in RV ejection fraction assessed by advanced cardiac imaging was found, without differences in functional class or quality of life.