Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
EuroIntervention ; 20(2): e158-e167, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38224253

RESUMO

BACKGROUND: Both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) are Class Ia recommended therapies for specific subgroups of severe aortic stenosis (AS) patients in the latest 2021 European guidelines. AIMS: We aimed to report on the multidisciplinary Heart Team evaluation process and real-world practice of treating severe symptomatic AS in East Denmark in the context of the latest European guideline recommendations. METHODS: All consecutive patients with severe AS referred for intervention in 2021 (N=672) were discussed in a multidisciplinary Heart Team meeting. All patients (100%) had a cardiac computed tomography (CT) analysis prior to the meeting. Baseline characteristics, Heart Team decision-making, final treatment and 30-day clinical outcomes were prospectively recorded. RESULTS: The majority of severe AS patients (N=456, 68%) were referred for TAVI following discussion in the Heart Team. Ultimately, 94% of patients (N=632) received the Heart Team-recommended treatment. Patients undergoing TAVI (N=439) were significantly older (78.4±6.7 vs 67.2±8.3 years; p<0.001) and more comorbid than patients undergoing SAVR (N=189). The overall 30-day clinical outcomes were satisfactory for both treatment groups (overall 30-day mortality: 1.1%). The mean index hospitalisation length was markedly longer in the SAVR group (8.6±8.3 days) as compared to the TAVI group (1.8±3.2 days). CONCLUSIONS: TAVI was routinely performed in low surgical risk patients in 2021 with two-thirds of all severe AS patients undergoing TAVI, thereby applying the latest European guidelines. A dedicated Heart Team meeting, including CT evaluation for all AS patients, is needed to make individualised management decisions in this new era of aortic valve interventions.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Coração , Hospitalização , Pacientes , Estenose da Valva Aórtica/cirurgia
2.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-37982158

RESUMO

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Dispositivos de Oclusão Vascular , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Hemorragia/etiologia , Hemorragia/prevenção & controle , Técnicas Hemostáticas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
4.
EuroIntervention ; 19(7): 589-599, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37436190

RESUMO

BACKGROUND: The optimal timing to perform percutaneous coronary interventions (PCI) in transcatheter aortic valve implantation (TAVI) patients remains unknown. AIMS: We sought to compare different PCI timing strategies in TAVI patients. METHODS: The REVASC-TAVI registry is an international registry including patients undergoing TAVI with significant, stable coronary artery disease (CAD) at preprocedural workup. In this analysis, patients scheduled to undergo PCI before, after or concomitantly with TAVI were included. The main endpoints were all-cause death and a composite of all-cause death, stroke, myocardial infarction (MI) or rehospitalisation for congestive heart failure (CHF) at 2 years. Outcomes were adjusted using the inverse probability treatment weighting (IPTW) method. RESULTS: A total of 1,603 patients were included. PCI was performed before, after or concomitantly with TAVI in 65.6% (n=1,052), 9.8% (n=157) or 24.6% (n=394), respectively. At 2 years, all-cause death was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (6.8% vs 20.1% vs 20.6%; p<0.001). Likewise, the composite endpoint was significantly lower in patients undergoing PCI after TAVI as compared with PCI before or concomitantly with TAVI (17.4% vs 30.4% vs 30.0%; p=0.003). Results were confirmed at landmark analyses considering events from 0 to 30 days and from 31 to 720 days. CONCLUSIONS: In patients with severe aortic stenosis and stable coronary artery disease scheduled for TAVI, performance of PCI after TAVI seems to be associated with improved 2-year clinical outcomes compared with other revascularisation timing strategies. These results need to be confirmed in randomised clinical trials.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/métodos , Estenose da Valva Aórtica/terapia , Infarto do Miocárdio/complicações , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
6.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36093795

RESUMO

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Circ Cardiovasc Interv ; 15(12): e012417, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36538579

RESUMO

BACKGROUND: The best management of stable coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is still unclear due to the marked inconsistency of the available evidence. METHODS: The REVASC-TAVI registry (Management of Myocardial Revascularization in Patients Undergoing Transcatheter Aortic Valve Implantation With Coronary Artery Disease) collected data from 30 centers worldwide on patients undergoing TAVI who had significant, stable CAD at preprocedural work-up. For the purposes of this analysis, patients with either complete or incomplete myocardial revascularization were compared in a propensity score matched analysis, to take into account of baseline confounders. The primary and co-primary outcomes were all-cause death and the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure, respectively, at 2 years. RESULTS: Among 2407 patients enrolled, 675 pairs of patients achieving complete or incomplete myocardial revascularization were matched. The primary (21.6% versus 18.2%, hazard ratio' 0.88 [95% CI, 0.66-1.18]; P=0.38) and co-primary composite (29.0% versus 27.1%, hazard ratio' 0.97 [95% CI, 0.76-1.24]; P=0.83) outcome did not differ between patients achieving complete or incomplete myocardial revascularization, respectively. These results were consistent across different prespecified subgroups of patients (< or >75 years of age, Society of Thoracic Surgeons score > or <4%, angina at baseline, diabetes, left ventricular ejection fraction > or <40%, New York Heart Association class I/II or III/IV, renal failure, proximal CAD, multivessel CAD, and left main/proximal anterior descending artery CAD; all P values for interaction >0.10). CONCLUSIONS: The present analysis of the REVASC-TAVI registry showed that, among TAVI patients with significant stable CAD found during the TAVI work-up, completeness of myocardial revascularization achieved either staged or concomitantly with TAVI was similar to a strategy of incomplete revascularization in reducing the risk of all cause death, as well as the risk of death, stroke, myocardial infarction, and rehospitalization for heart failure at 2 years, regardless of the clinical and anatomical situations.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Fatores de Risco , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Função Ventricular Esquerda , Revascularização Miocárdica/efeitos adversos , Infarto do Miocárdio/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Intervenção Coronária Percutânea/efeitos adversos
8.
Artigo em Inglês | MEDLINE | ID: mdl-36542648

RESUMO

BACKGROUND: Use of a right-left (R-L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self-expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data-driven explanation for this observation is missing. AIMS: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/NavitorTM transcatheter heart valve (THV; Abbott). METHODS: A TAVR-population treated with Portico/NavitorTM had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system. The impact of these different implantation views on the spatial relationship between THV and native aortic annulus and the risk of conduction disturbances and PPMI after TAVR was studied. RESULTS: A total of 366 matched TAVR patients were studied: 183 in the RAO group and 183 in the LAO group. The degree of aortic annulus plane tilt was significantly smaller in the RAO versus LAO group (median: 0° vs. 23°, p < 0.001), with no plane tilt in 105 out of 183 cases (57.3%) in the RAO group. At 30 days after TAVR, the overall PPMI and guideline-directed PPMI rates were 12.6% versus 18.0% (p = 0.15) and 8.2% versus 15.3% (p = 0.04) in the RAO versus LAO group, respectively. CONCLUSIONS: Use of a R-L cusp overlap (RAO-caudal) view for implantation of the Portico/NavitorTM valve results in less tilt of the native aortic annulus plane and a clear trend toward a lower 30-day PPMI rate as compared to TAVR using the conventional LAO implantation view.

11.
Catheter Cardiovasc Interv ; 100(5): 795-800, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35880854

RESUMO

OBJECTIVES: This study aimed to assess the rate of difficult interatrial septum (IAS) crossing with the intracardiac echocardiography (ICE) probe during percutaneous left atrial appendage (LAA) closure and to identify techniques that facilitate IAS crossing with the ICE probe. BACKGROUND: Percutaneous LAA closure is increasingly performed by ICE guidance. Although such an approach omits the need for general anesthesia, crossing of the IAS with the ICE probe may sometimes be challenging. METHODS: All consecutive patients that underwent ICE-guided percutaneous LAA closure with an Amplatzer Amulet (Abbott) or WatchmanFLX (Boston Scientific) at our center in the period 2018-2021 were included. Cases in which IAS crossing with ICE was difficult were identified and techniques used to facilitate IAS crossing were identified and listed. RESULTS: In 17 (5%) out of 354 cases, IAS crossing with the ICE probe was difficult and required use of additional techniques. Ultimately, IAS crossing was also successful in these 17 cases by using one of three possible facilitation techniques: the probing technique (12 cases), the double-wire technique (3 cases), and the snaring technique (2 cases). In one case, the double-wire technique was converted to the snaring technique, as crossing of the ICE probe remained challenging despite the use of two stiff guidewires. CONCLUSION: Crossing of the IAS with the ICE probe can be challenging in 5% of ICE-guided percutaneous LAA closure procedures. Operators should be aware of possible facilitation techniques in challenging cases, as these show to be safe and effective.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento
12.
Clin Res Cardiol ; 111(12): 1358-1366, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35767098

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) in bicuspid aortic valve (BAV) stenosis has become more frequent in the last years. This may pose challenges for long-time valve durability. Therefore, we aimed to evaluate the prevalence of bioprosthetic valve dysfunction (BVD) with the newest-generation devices in BAV stenosis up to one-year follow-up (FU). METHODS: The primary endpoint was defined as the prevalence of BVD during the first procedural year according to Valve Academic Research Consortium (VARC)-3 criteria. Secondary endpoints were defined as failure in device success and clinical endpoints according to VARC-3. RESULTS: A total of 107 patients were included. Of these, 34 subjects (31.8%) met the criteria for BVD during a mean FU of 263 ± 180 days, of which 20.2% were already documented after thirty days. Device success after one year was lower in the + BVD cohort (57.6% vs. 98.7%, p < 0.0001*). The rates of structural valve deterioration were 6.5%, non-structural valve deterioration (NSVD) 17.8%, subclinical leaflet thickening 10.3%, and endocarditis 0.9%. NSVD was foremost triggered by patient prosthesis mismatch in balloon-expandable valves. Hemodynamic valve deterioration stage 1 and 2 was confirmed in 16.8% of + BVD patients, while stage 1 and 3 bioprosthetic valve failure occurred in 1.9%. There was no impact of BVD on mortality. CONCLUSION: There is critical evidence of early BVD after TAVI in BAV during one-year FU in one-third of patients, also lowering device success. The most frequently observed bioprosthetic valve dysfunction was NSVD due to patient prosthesis mismatch following TAVI with a balloon-expandable valve.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Constrição Patológica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/cirurgia
13.
Cardiovasc Revasc Med ; 40S: 120-122, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35450811

RESUMO

This case report describes the first transcatheter aortic valve replacement (TAVR) with the latest-generation Navitor Titan™ transcatheter heart valve (Abbott, USA) in a European patient with severe symptomatic aortic valve stenosis (AS). The Navitor Titan™ transcatheter heart valve has been developed to treat patients with large aortic annuli, namely aortic annulus perimeter 85 to 95 mm. In combination with the low profile FlexNav™ delivery system, the Navitor Titan™ valve offers the unique possibility to treat AS patients with large aortic annuli and suboptimal vascular access.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
14.
J Vis Exp ; (181)2022 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-35343967

RESUMO

During the last decade, transcatheter aortic valve implantation (TAVI) has evolved as a well-established therapy for aging patients suffering from symptomatic severe aortic valve stenosis. This is also reflected in the recently updated international guidelines on managing patients with valvular heart disease. A transfemoral (TF) TAVI approach has proven superior to alternative access strategies. With the introduction of intravascular lithotripsy (IVL), patients with calcified iliofemoral vascular disease and borderline intraluminal diameters have also become candidates for percutaneous TF-TAVI. Moreover, IVL reduces the risk of major vascular complications by modifying the superficial and deep vascular calcium, thereby changing the vessel compliance and controlling luminal expansion. In this way, IVL has shown to safely facilitate TF delivery of TAVI devices in patients with calcified peripheral artery disease. The present article aims to provide a detailed step-by-step description on how to perform IVL-assisted TF-TAVI safely and efficiently. Furthermore, a literature review on the outcomes obtained with this technology is included, along with a concise discussion on this unique TAVI approach.


Assuntos
Estenose da Valva Aórtica , Litotripsia , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Eur Heart J ; 40(22): 1804-1814, 2019 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-30895296

RESUMO

AIMS: During the first 6-12 h of intensive care unit (ICU) stay, post-cardiac arrest (CA) patients treated with a mean arterial pressure (MAP) 65 mmHg target experience a drop of the cerebral oxygenation that may cause additional cerebral damage. Therefore, we investigated whether an early goal directed haemodynamic optimization strategy (EGDHO) (MAP 85-100 mmHg, SVO2 65-75%) is safe and could improve cerebral oxygenation, reduce anoxic brain damage, and improve outcome when compared with a MAP 65 mmHg strategy. METHODS AND RESULTS: A total of 112 out-of-hospital CA patients were randomly assigned to EGDHO or MAP 65 mmHg strategies during the first 36 h of ICU stay. The primary outcome was the extent of anoxic brain damage as quantified by the percentage of voxels below an apparent diffusion coefficient (ADC) score of 650.10-6 mm2/s on diffusion weighted magnetic resonance imaging (at day 5 ± 2 post-CA). Main secondary outcome was favourable neurological outcome (CPC score 1-2) at 180 days. In patients assigned to EGDHO, MAP (P < 0.001), and cerebral oxygenation during the first 12 h of ICU stay (P = 0.04) were higher. However, the percentage of voxels below an ADC score of 650.10-6 mm2/s did not differ between both groups [16% vs. 12%, odds ratio 1.37, 95% confidence interval (CI) 0.95-0.98; P = 0.09]. Also, the number of patients with favourable neurological outcome at 180 days was similar (40% vs. 38%, odds ratio 0.98, 95% CI 0.41-2.33; P = 0.96). The number of serious adverse events was lower in patients assigned to EGDHO (P = 0.02). CONCLUSION: Targeting a higher MAP in post-CA patients was safe and improved cerebral oxygenation but did not improve the extent of anoxic brain damage or neurological outcome.


Assuntos
Hemodinâmica/fisiologia , Hipóxia Encefálica/prevenção & controle , Neuroproteção/fisiologia , Parada Cardíaca Extra-Hospitalar/terapia , Idoso , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Coma/etiologia , Coma/fisiopatologia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Hipóxia Encefálica/etiologia , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/complicações , Oxigênio/sangue , Oxigênio/metabolismo , Resultado do Tratamento , Troponina/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA