Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Int Braz J Urol ; 50(3): 277-286, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598830

RESUMO

PURPOSE: CT-guided MWA is a safe and effective tool that should be utilized in the treatment of small renal masses (SRMs). We aim to clarify the utility of CT-guided MWA by examining patient outcomes such as recurrence, treatment success, changes in renal function, and complications. METHODS: A retrospective review of consecutive patients with SRMs who underwent same day renal mass biopsy (RMB) and CT-guided MWA between 2015 and 2022 was performed. Treatment safety was assessed by 30-day complications according to the Clavien-Dindo system and change in eGFR >30 days post-procedure. Treatment efficacy was defined by local recurrence and incomplete treatment rates and calculated using the Kaplan-Meier method. RESULTS: A total of 108 renal masses were found in 104 patients. The overall complication rate was 7.4% (8/108), of which 4 were major complications (3.7%). For those with renal function available >30 days post ablation, the median eGFR was 47.2 (IQR: 36.0, 57), compared to 52.3 (IQR: 43.7, 61.5) pre-ablation, p<0.0001. 5-year local recurrence free survival was 86%. Among those with biopsy proven malignancy (n= 66), there were five local recurrences (7.54%) occurring at a median of 25.1 months (IQR 19.9, 36.2) and one case (1.5%) of incomplete treatment. CONCLUSIONS: As the medical field continues to evolve towards less invasive interventions, MWA offers a valuable tool in the management of renal masses. With low major complication and recurrence rates, our findings support the utility of CT-guided MWA as a tool for treatment of SRMs.


Assuntos
Técnicas de Ablação , Carcinoma de Células Renais , Ablação por Cateter , Neoplasias Renais , Humanos , Neoplasias Renais/patologia , Carcinoma de Células Renais/patologia , Micro-Ondas/uso terapêutico , Resultado do Tratamento , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Estudos Retrospectivos , Ablação por Cateter/métodos
2.
Spine (Phila Pa 1976) ; 42(3): E163-E168, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27306257

RESUMO

STUDY DESIGN: Single-institution, retrospective case series. OBJECTIVE: To determine whether the microbiology of deep surgical site infections (SSIs) after spinal fusion surgery for deformity has changed over the last decade at our institution. SUMMARY OF BACKGROUND DATA: SSI after pediatric spinal deformity surgery results in significantly increased patient morbidity and health care costs. Although risk factors are multifactorial, prophylactic and treatment antibiotic coverage is based in part on historical epidemiologic data, which may evolve over time. METHODS: This study represents a retrospective review of clinical and microbiology records of patients less than 21 years old who underwent spinal deformity surgery at a single institution between 2000 and 2012. Patients were included who underwent index surgery at our institution and developed a deep SSI. Patients with growth-preserving spine constructs were excluded. RESULTS: The overall incidence of deep SSI was 3.6% (39/1094). The incidence of deep SSI following primary surgery was 3.3% (34/1034) and 8.3% (5/60) following revision surgery. The incidence of deep SSI varied by primary diagnosis: idiopathic (1.0%), neuromuscular (14.3%), syndromic (5.3%), congenital (5.7%), and kyphosis (0.0%). The most common inciting pathogens were Staphylococcus epidermidis (26%), methicillin-sensitive Staphylococcus aureus (MSSA, 18%), Propionibacterium acnes (P. acnes; 18%), and Escherichia coli (18%). Sixteen of the 18 (89%) gram-negative infections occurred in neuromuscular patients (P = 0.006). Between 2000 and 2006 and between 2007 and 2012, MSSA occurred in 2/18 (11%) and 5/21 (24%) of cases (P = 0.41), methicillin-resistant S. aureus occurred in 1/18 (6%) and 3/21 (14%) (P = 0.61), and P. acnes occurred in 3/18 (17%) and 4/21 (19%) (P = 1.0). CONCLUSION: The epidemiology of deep SSI following spinal fusion for deformity in pediatric patients at our institution has not changed significantly during 13 years. Prophylactic antibiotic coverage for both gram-positive and gram-negative organisms may be indicated for patients with primary neuromuscular diagnoses. LEVEL OF EVIDENCE: 4.


Assuntos
Antibacterianos/uso terapêutico , Doenças da Coluna Vertebral/cirurgia , Fusão Vertebral/efeitos adversos , Infecções Estafilocócicas/epidemiologia , Staphylococcus aureus/isolamento & purificação , Infecção da Ferida Cirúrgica/epidemiologia , Adolescente , Antibioticoprofilaxia/métodos , Criança , Humanos , Incidência , Masculino , Resistência a Meticilina/efeitos dos fármacos , Estudos Retrospectivos , Fatores de Risco
3.
J Biomech ; 47(5): 1127-33, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24480701

RESUMO

The cost and time efficiency of computational polyethylene wear simulations may enable the optimization of total knee replacements for the reduction of polyethylene wear. The present study proposes an energy dissipation wear model for polyethylene which considers the time dependent molecular behavior of polyethylene, aspects of tractive rolling and contact pressure. This time dependent - energy dissipation wear model was evaluated, along with several other wear models, by comparison to pin-on-disk results, knee simulator wear test results under various kinematic conditions and knee simulator wear test results that were performed following the ISO 14243-3 standard. The proposed time dependent - energy dissipation wear model resulted in improved accuracy for the prediction of pin-on-disk and knee simulator wear test results compared with several previously published wear models.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/fisiologia , Prótese do Joelho , Modelos Biológicos , Polietileno/química , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Articulação do Joelho/cirurgia , Pressão
4.
J Arthroplasty ; 28(1): 197.e17-21, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22770854

RESUMO

A 34-year-old female patient received a cobalt-chromium (CoCr) alloy femoral head on cross-linked polyethylene total hip replacement for the revision of her fractured ceramic-on-ceramic total hip replacement. The CoCr alloy femoral head became severely worn due to third-body abrasive wear by ceramic particles that could not be removed by synovectomy or irrigation at revision surgery. Ceramic particles were found embedded in the cross-linked polyethylene liner. The CoCr alloy femoral head exhibited a total mass loss of 14.2 g and the generated wear particles triggered metallosis in the patient. The present case study suggests not revising a fractured ceramic-on-ceramic total hip replacement with a CoCr alloy femoral head and a cross-linked polyethylene liner to avoid metallosis due to third-body abrasive wear.


Assuntos
Artroplastia de Quadril , Ligas de Cromo/efeitos adversos , Prótese de Quadril/efeitos adversos , Polietilenos/efeitos adversos , Falha de Prótese , Adulto , Cerâmica/efeitos adversos , Feminino , Humanos , Reoperação , Estresse Mecânico
5.
J Pediatr Urol ; 8(3): 276-81, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21616719

RESUMO

PURPOSE: Laparoscopic reconstructive procedures in the pediatric patient are associated with a steep learning curve. Outcomes from robotic-assisted pediatric urology have been reported by surgeons with known facility in laparoscopic surgery. We describe the experience of a single surgeon in transitioning from open to robotic-assisted laparoscopic pyeloplasty (RALP) without previous training in traditional laparoscopic pyeloplasty or intracorporeal suturing. MATERIALS AND METHODS: We reviewed our experience with 20 (mean age 7.4 years) consecutive children undergoing RALP for ureteropelvic junction obstruction at our institution over 36 months. Additionally, a literature search was conducted to identify age-similar patient groups who underwent open and laparoscopic pyeloplasty. RESULTS: Length of hospitalization and postoperative analgesia requirement were greater in the age-similar open pyeloplasty group compared to the other two groups. Intraoperative times were greater in the laparoscopic and RALP groups compared to the open pyeloplasty group. CONCLUSIONS: Our experience confirms the feasibility of transitioning from open to robotic-assisted laparoscopic pediatric pyeloplasty without previous experience in conventional laparoscopy. Outcomes, analgesic requirement and hospitalization for the patients from our institution are comparable to the laparoscopy patient group and improved compared to open pyeloplasty patients from the literature.


Assuntos
Pelve Renal/cirurgia , Laparoscopia/métodos , Procedimentos de Cirurgia Plástica/métodos , Robótica/métodos , Ureter/cirurgia , Obstrução Ureteral/cirurgia , Procedimentos Cirúrgicos Urológicos/métodos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Lactente , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA