1.
J Thorac Dis ; 16(4): 2623-2636, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38738252

RESUMO

Background and Objective: Blood flow assessment is an emerging technique that allows for assessment of hemodynamics in the heart and blood vessels. Recent advances in cardiovascular imaging technologies have made it possible for this technique to be more accessible to clinicians and researchers. Blood flow assessment typically refers to two techniques: measurement-based flow visualization using echocardiography or four-dimensional flow magnetic resonance imaging (4D flow MRI), and computer-based flow simulation based on computational fluid dynamics modeling. Using these methods, blood flow patterns can be visualized and quantitative measurements of mechanical stress on the walls of the ventricles and blood vessels, most notably the aorta, can be made. Thus, blood flow assessment has been enhancing the understanding of cardiac and aortic diseases; however, its introduction to clinical practice has been negligible yet. In this article, we aim to discuss the clinical applications and future directions of blood flow assessment in aortic surgery. We then provide our unique perspective on the technique's translational impact on the surgical management of aortic disease. Methods: Articles from the PubMed database and Google Scholar regarding blood flow assessment in aortic surgery were reviewed. For the initial search, articles published between 2013 and 2023 were prioritized, including original articles, clinical trials, case reports, and reviews. Following the initial search, additional articles were considered based on manual searches of the references from the retrieved literature. Key Content and Findings: In aortic root pathology and ascending aortic aneurysms, blood flow assessment can elucidate postoperative hemodynamic changes after surgical reconfiguration of the aortic valve complex or ascending aorta. In cases of aortic dissection, analysis of blood flow can predict future aortic dilatation. For complicated congenital aortic anomalies, surgeons may use preoperative imaging to perform "virtual surgery", in which blood flow assessment can predict postoperative hemodynamics for different surgical reconstructions and assist in procedural planning even before entering the operating room. Conclusions: Blood flow assessment and computational modeling can evaluate hemodynamics and flow patterns by visualizing blood flow and calculating biomechanical forces in patients with aortic disease. We anticipate that blood flow assessment will become an essential tool in the treatment planning and understanding of the progression of aortic disease.

2.
Ann Vasc Surg ; 80: 273-282, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34752856

RESUMO

BACKGROUND: Unlike periprocedural Type 1A endoleaks, late appearing proximal endoleaks have been poorly described. METHODS: We studied all elective EVAR from 2010 -2018 in a single institution. Late endoleaks were defined as those appearing after 1 year. We used Cox regression to study factors associated with late Type 1A endoleaks and survival. RESULTS: Of 477 EVAR during the study period, 411 (86%) had follow-up imaging, revealing 24 Type 1A endoleaks; 4 early and 20 late. Freedom from Type 1A endoleaks was 99%, 92-81% at 1, 5 and 8 years with a median time to occurrence of 2.5 years (.01-8.2 years). On completion angiogram, only 10% of patients with a late Type 1A had a proximal endoleak, and 60% had no endoleak. Only 21% of late Type 1As were diagnosed on routine 1-year CT angiogram, but 79% had stable or expanding sacs. Two thirds (65%) of the patients eventually diagnosed with late Type 1A endoleaks had previously been treated for other endoleaks, mostly Type 2 (10/13). Age (HR 1.07/year [1.02-1.12], P = 0.01), neck diameter >28mm (HR 3.5 [1.2-10.3], P = 0.02), neck length <20mm (HR 3.0 [1.1-8.6], P = 0.04), and neck angle>60 degrees (HR 3.4 [1.5-7.9], P = 0.004) were associated with higher rates of Type 1A endoleak, but not female sex, endograft, or the use of suprarenal fixation. 2 patients had proximal degeneration and 5 experienced graft migration. There were 2 ruptures (10%), and 13 patients underwent repair with 5 open conversions. Median survival after late Type 1A repair was 6.6 years (0-8.4 years). CONCLUSION: Late appearing Type 1A endoleaks have a high rate of rupture and present significant diagnostic and management challenges. Careful surveillance is needed in patients with hostile neck anatomy and those who undergo intervention for other endoleaks. Adverse neck anatomy may be better suited for open repair or fenestrated/branched devices rather than conventional EVAR.


Assuntos
Aneurisma Aórtico/cirurgia , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/mortalidade , Ruptura Aórtica/etiologia , Endoleak/diagnóstico , Endoleak/terapia , Feminino , Humanos , Masculino , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Stents , Análise de Sobrevida , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA