Lab Chip ; 14(6): 1087-98, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24448498

RESUMO

During the last decade, saliva has emerged as a potentially ideal diagnostic biofluid for noninvasive testing. In this paper, we present an automated, integrated platform useable by minimally trained personnel in the field for the diagnosis of respiratory diseases using human saliva as a sample specimen. In this platform, a saliva sample is loaded onto a disposable microfluidic chip containing all the necessary reagents and components required for saliva analysis. The chip is then inserted into the automated analyzer, the SDReader, where multiple potential protein biomarkers for respiratory diseases are measured simultaneously using a microsphere-based array via fluorescence sandwich immunoassays. The results are read optically, and the images are analyzed by a custom-designed algorithm. The fully automated assay requires as little as 10 µL of saliva sample, and the results are reported in 70 min. The performance of the platform was characterized by testing protein standard solutions, and the results were comparable to those from the 3.5 h lab bench assay that we have previously reported. The device was also deployed in two clinical environments where 273 human saliva samples collected from different subjects were successfully tested, demonstrating the device's potential to assist clinicians with the diagnosis of respiratory diseases by providing timely protein biomarker profiling information. This platform, which combines noninvasive sample collection and fully automated analysis, can also be utilized in point-of-care diagnostics.


Assuntos
Asma/metabolismo , Técnicas Analíticas Microfluídicas , Saliva/metabolismo , Proteínas e Peptídeos Salivares/metabolismo , Adulto , Asma/diagnóstico , Biomarcadores/metabolismo , Feminino , Humanos , Masculino , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Estudos Retrospectivos , Fatores de Tempo
2.
Lab Chip ; 13(7): 1325-32, 2013 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-23370016

RESUMO

A microfluidic chip integrating DNA extraction, amplification, and detection for the identification of bacteria in saliva is described. The chip design integrated a monolithic aluminum oxide membrane (AOM) for DNA extraction with seven parallel reaction wells for real-time polymerase chain reaction (rtPCR) amplification of the extracted DNA. Samples were first heated to lyse target organisms and then added to the chip and filtered through the nanoporous AOM to extract the DNA. PCR reagents were added to each of the wells and the chip was thermocycled. Identification of Streptococcus mutans in a saliva sample is demonstrated along with the detection of 300 fg (100-125 copies) of both methicillin-susceptible Staphylococcus aureus (MSSA) and methicillin-resistant S. aureus (MRSA) genomic DNA (gDNA) spiked into a saliva sample. Multiple target species and strains of bacteria can be simultaneously identified in the same sample by varying the primers and probes used in each of the seven reaction wells. In initial tests, as little as 30 fg (8-12 copies) of MSSA gDNA in buffer has been successfully amplified and detected with this device.


Assuntos
DNA Bacteriano/genética , DNA Bacteriano/isolamento & purificação , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Técnicas Analíticas Microfluídicas/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Saliva/microbiologia , Streptococcus mutans/isolamento & purificação , Contaminação por DNA , Primers do DNA/genética , Humanos , Staphylococcus aureus Resistente à Meticilina/genética , Streptococcus mutans/genética , Fatores de Tempo