Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Chemosphere ; 263: 127827, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32835966

RESUMO

Volatile losses of hydrophobic organic contaminants from a confined disposal facility (CDF) containing dredged contaminated sediments is of substantial concern to surrounding communities. A partitioning passive sampling approach using polyoxymethylene (POM) was applied to measure long-term average (weeks to months) air concentrations resulting from evaporation at a CDF. Measurements at 10 locations surrounding the CDF using the POM air samplers indicated that the highest concentrations of ΣPCBs∼13 ng/m3 and ΣPAHs ∼65 ng/m3 were measured during an active dredge material placement period when the average temperature was 23 °C. The measurements were dominated by the more volatile, lower molecular weight compounds of each type. Partitioning to the POM during the post dredge material placement period with average temperature of 5 °C was corrected for temperature and the measured ∑PCBs and ∑PAHs were ∼3 ng/m3 and 45 ng/m3 respectively. The partitioning passive sampling measurements agreed well with the available weekly 24-h high-volume air samples (HVAS) averaged over the POM equilibration time for lower congener number PCBs (15, 18, 20/28 and 31) and naphthalene but were as much as 10 times lower than HVAS for high molecular weight PAHs. The difference was likely the result of the greater association of these PAHs with particulates and sources other than evaporation from the CDF. The POM air sampler achieved the goal of providing a long-term average air concentration without having to collect, analyze and average multiple HVAS samples although the technique is largely limited to the lower molecular weight PAHs and PCBs and different equilibration times for different compounds complicate its use and analysis.


Assuntos
Poluentes Atmosféricos , Bifenilos Policlorados , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Atmosféricos/análise , Monitoramento Ambiental , Bifenilos Policlorados/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Resinas Sintéticas
2.
Environ Pollut ; 265(Pt A): 114720, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32473506

RESUMO

In this study, 76 µm polyoxymethylene (POM) strips were evaluated as a passive air sampler (PAS) for monitoring the volatile emissions from dredged material placed in confined disposal facilities (CDF). Laboratory evaluations were used to assess the uptake kinetics, average equilibrium time, and estimate the POM-air partition coefficients (KPOM-A) of 16 PCB congeners. The uptake kinetics defined the effective averaging time for air sampling and ranged from about a week for dichlorobiphenyls to 2 weeks or more for tetra- and pentachlorobiphenyls at ∼20 °C under internal mass transfer resistance control which was applicable for Log KPOM-A < 8. The measured Log KPOM-A for PCBs ranged from 5.65 to 9.34 and exhibited an average deviation of 0.19 log unit from the theoretical value of KPOM-W/KAW. The PAS approach was then tested with a preliminary field application (n = 17) at a CDF allowing equilibration over 42 days. The field application focused on lower congener PCBs as a result of the estimated increase in KPOM-A and longer uptake times expected at the low ambient temperatures during the field study (average of 3.5 °C). Total PCB air concentrations around the CDF averaged 0.32 ng/m3 and varied according to proximity to placement of the dredged materials and predominant wind directions. Average PAS concentration of low congener number PCBs (15, 18, 20/28, 31) were compared to available high volume air sampler (HVAS) measurements. The PAS concentrations were within 20% of HVAS in the dominant north and south directions and showed similar trends as east and west HVAS samplers although PAS concentrations were as much as an order of magnitude below the west HVAS.


Assuntos
Poluentes Atmosféricos/análise , Bifenilos Policlorados/análise , Monitoramento Ambiental , Resinas Sintéticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA