Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-36847677

RESUMO

BACKGROUND: Sex does have an effect on disease perception and outcomes after cardiac surgery. OBJECTIVES: The aim of this study was to quantify the differences in cardiovascular risk profiles within an age-matched cohort and assess the long-term survival differences in males and females who underwent surgical aortic valve replacement (SAVR) with or without concomitant coronary artery bypass surgery. METHODS: All-comers patients who underwent SAVR with or without coronary artery bypass surgery were included. Characteristics, clinical features and survival up to 30 years were compared between female and male patients. Propensity matching and age matching using propensity scores were used to compare both groups. RESULTS: During the total study period between 1987 and 2017, there were 3462 patients {mean age 66.8 [standard deviation (SD): 11.1] years, 37.1% female} who underwent SAVR with or without coronary artery bypass surgery at our institution. In general, female patients were older than male patients (69.1 (SD : 10.3) versus 65.5 (SD : 11.3), respectively). In the age-matched cohort, female patients were less likely to have multiple comorbidities and undergo concomitant coronary artery bypass surgery. Twenty-year survival following the index procedure was higher in age-matched female patients (27.1%) compared to male patients (24.4%) in the overall cohort (P = 0.018). CONCLUSIONS: Substantial sex differences in cardiovascular risk profile exist. However, when SAVR with or without coronary artery bypass surgery is performed, extended long-term mortality is comparable between males and females. More research regarding sex-dimorphic mechanisms of aortic stenosis and coronary atherosclerosis would promote more awareness in terms of sex-specific risk factors after cardiac surgery and contribute to more guided personalized surgery in the future.

2.
J Thorac Cardiovasc Surg ; 164(6): 1742-1751.e8, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34053741

RESUMO

OBJECTIVE: The study objective was to analyze temporal changes in baseline and procedural characteristics and long-term survival of patients undergoing surgical aortic valve replacement over a 30-year period. METHODS: A retrospective analysis of patients undergoing surgical aortic valve replacement between 1987 and 2016 in the Erasmus Medical Center (Rotterdam, The Netherlands) was conducted. Patient baseline and procedural characteristics were analyzed in periods according to the date of surgical aortic valve replacement (period A: 1987-1996; B: 1997-2006; C: 2007-2016). Survival status was determined using the Dutch National Death Registry. Relative survival was obtained by comparing the survival after surgical aortic valve replacement with the survival of the age-, sex-, and year-matched general population. RESULTS: Between 1987 and 2016, 4404 patients underwent SAVR. From period A to C, the mean age increased from 63.9 ± 11.2 years to 66.2 ± 12.3 years (P < .001), and the prevalence of diabetes mellitus, hypertension, hypercholesterolemia, previous myocardial infarction, and previous stroke at baseline increased (P values for trend for all < .001). The prevalence of concomitant procedures increased from 42.4% in period A to 48.3% in period C (P = .004). Bioprosthesis use increased significantly (18.8% in period A vs 67.1% in period C, P < .001). Mean survival after surgical aortic valve replacement was 13.8 years. Relative survival at 20 years in the overall cohort was 60.4% (95% confidence interval, 55.9-65.2) and 73.8% (95% confidence interval, 67.1-81.1) in patients undergoing isolated primary surgical aortic valve replacement. CONCLUSIONS: Patient complexity has been continuously increasing over the last 30 years, yet long-term survival after surgical aortic valve replacement remains high compared with the age-, sex-, and year-matched general population.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Pessoa de Meia-Idade , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos , Fatores de Risco
3.
Front Cardiovasc Med ; 9: 1031365, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36712256

RESUMO

Background: Impairment of conduction across Bachmann's Bundle (BB) may cause advanced interatrial block (a-IAB), which in turn is associated with development of atrial fibrillation. However, the exact relation between a complete transverse line of conduction block (CB) across BB and the presence of a-IAB has not been studied. Objective: The aims of this study are to determine whether (1) a complete transversal line of CB across BB established by high resolution mapping correlates with a-IAB on the surface ECG, (2) conduction abnormalities at the right and left atria correlate with a-IAB, and (3) excitation patterns are associated with ECG characteristics of a-IAB. Methods: We included 40 patients in whom epicardial mapping revealed a complete transverse line of CB across BB. Pre-operative ECGs and post-operative telemetry were assessed for the presence of (a) typical a-IAB and de novo early post-operative AF (EPOAF), respectively. Total atrial excitation time (TAET) and RA-LA delay were calculated. Entry site and trajectory of the main sinus rhythm wavefront at the pulmonary vein area (PVA) were assessed. Results: Thirteen patients were classified as a-IAB (32.5%). In the entire atria and BB there were no differences in conduction disorders, though, patients with a-IAB had an increased TAET and longer RA-LA delay compared to patients without a-IAB (90.0 ± 21.9 ms vs. 74.9 ± 13.0 ms, p = 0.017; 160.0 ± 27.0 ms vs. 136.0 ± 24.1 ms, p = 0.012, respectively). Patients with typical a-IAB solely had caudocranial activation of the PVA, without additional cranial entry sites. Prevalence of de novo EPOAF was 69.2% and was similar between patients with and without a-IAB. Conclusion: A transverse line of CB across BB partly explains the ECG characteristics of a-IAB. We found atrial excitation patterns underlying the ECG characteristics of both atypical and typical a-IAB. Regardless of the presence of a-IAB, the clinical impact of a complete transverse line of CB across BB was reflected by a high incidence of de novo EPOAF.

4.
J Cardiovasc Dev Dis ; 8(4)2021 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-33807143

RESUMO

Objectives the exact timing of aortic valve replacement (AVR) in asymptomatic patients with severe aortic stenosis (AS) remains a matter of debate. Therefore, we described the natural history of asymptomatic patients with severe AS, and the effect of AVR on long-term survival. Methods: Asymptomatic patients who were found to have severe AS between June 2006 and May 2009 were included. Severe aortic stenosis was defined as peak aortic jet velocity Vmax ≥ 4.0 m/s or aortic valve area (AVA) ≤ 1 cm2. Development of symptoms, the incidence of AVR, and all-cause mortality were assessed. Results: A total of 59 asymptomatic patients with severe AS were followed, with a mean follow-up of 8.9 ± 0.4 years. A total of 51 (86.4%) patients developed AS related symptoms, and subsequently 46 patients underwent AVR. The mean 1-year, 2-year, 5-year, and 10-year overall survival rates were higher in patients receiving AVR compared to those who did not undergo AVR during follow-up (100%, 93.5%, 89.1%, and 69.4%, versus 92.3%, 84.6%, 65.8%, and 28.2%, respectively; p < 0.001). Asymptomatic patients with severe AS receiving AVR during follow-up showed an incremental benefit in survival of up to 31.9 months compared to conservatively managed patients (p = 0.002). Conclusions: The majority of asymptomatic patients turn symptomatic during follow-up. AVR during follow-up is associated with better survival in asymptomatic severe AS patients.

5.
Eur J Cardiothorac Surg ; 59(6): 1191-1199, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-33496318

RESUMO

OBJECTIVES: Patients with bicuspid aortic valve (BAV) comprise a substantial portion of patients undergoing surgical aortic valve replacement (SAVR). Our goal was to quantify the prevalence of BAV in the current SAVR ± coronary artery bypass grafting (CABG) population, assess differences in cardiovascular risk profiles and assess differences in long-term survival in patients with BAV compared to patients with tricuspid aortic valve (TAV). METHODS: Patients who underwent SAVR with or without concomitant CABG and who had a surgical report denoting the relevant valvular anatomy were eligible and included. Prevalence, predictors and outcomes for patients with BAV were analysed and compared to those patients with TAV. Matched patients with BAV and TAV were compared using a propensity score matching strategy and an age matching strategy. RESULTS: A total of 3723 patients, 3145 of whom (mean age 66.6 ± 11.4 years; 37.4% women) had an operative report describing their aortic valvular morphology, underwent SAVR ± CABG between 1987 and 2016. The overall prevalence of patients with BAV was 19.3% (607). Patients with BAV were younger than patients with TAV (60.6 ± 12.1 vs 68.0 ± 10.7, respectively). In the age-matched cohort, patients with BAV were less likely to have comorbidities, among others diabetes (P = 0.001), hypertension (P < 0.001) and hypercholesterolaemia (P = 0.003), compared to patients with TAV. Twenty-year survival following the index procedure was higher in patients with BAV (14.8%) compared to those with TAV (12.9%) in the age-matched cohort (P = 0.015). CONCLUSIONS: Substantial differences in the cardiovascular risk profile exist in patients with BAV and TAV. Long-term survival after SAVR in patients with BAV is satisfactory.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
6.
Interact Cardiovasc Thorac Surg ; 31(5): 587-594, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32995837

RESUMO

OBJECTIVES: Although the standard of care for patients with severe aortic stenosis at low-surgical risk has included surgical aortic valve replacement (SAVR) since the mid-1960s, many clinical studies have investigated whether transcatheter aortic valve implantation (TAVI) can be a better approach in these patients. As no individual study has been performed to detect the difference in mortality between these 2 treatment strategies, we did a reconstructive individual patient data analysis to study the long-term difference in all-cause mortality. METHODS: Randomized clinical trials and propensity score-matched studies that included low-risk adult patients with severe aortic stenosis undergoing either SAVR or TAVI and with reports on the mortality rates during the follow-up period were considered. The primary outcome was all-cause mortality of up to 5 years. RESULTS: In the reconstructed individual patient data analysis, there was no statistically significant difference in all-cause mortality between TAVI and SAVR at 5 years of follow-up [30.7% vs 21.4%, hazard ratio (HR) 1.19, 95% confidence interval (CI) 0.96-1.48; P = 0.104]. However, landmark analyses in patients surviving up to 1 year of follow-up showed significantly higher all-cause mortality at 5 years of follow-up (27.5% vs 17.3%, HR 1.77, 95% CI 1.29-2.43; P < 0.001) in patients undergoing TAVI compared to patients undergoing SAVR, respectively. CONCLUSIONS: This reconstructed individual patient data analysis in low-risk patients with severe aortic stenosis demonstrates that the 5-year all-cause mortality rates are higher after TAVI than after SAVR, driven by markedly higher mortality rates between 1 and 5 years of follow-up in the TAVI group. The present results call for caution in expanding the TAVI procedure as the treatment of choice for the majority of all low-risk patients until long-term data from contemporary randomized clinical trials are available.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Modelos de Riscos Proporcionais , Resultado do Tratamento
7.
J Am Heart Assoc ; 9(17): e017069, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32808551

RESUMO

Background The significance of endo-epicardial asynchrony (EEA) and atrial conduction block (CB), which play an important role in the pathophysiology of atrial fibrillation (AF) during sinus rhythm is poorly understood. The aim of our study was therefore to examine 3-dimensional activation of the human right atrium (RA). Methods and Results Eighty patients (79% men, 39% history of AF) underwent simultaneous endo-epicardial sinus rhythm mapping of the inferior, middle and superior RA. Areas of CB were defined as conduction delays of ≥12 ms, EEA as activation time differences of opposite electrodes of ≥15 ms and transmural CB as CB at similar endo-epicardial sites. CB was more pronounced at the endocardium (all locations P<0.025). Amount, extensiveness and severity of CB was higher at the superior RA. Transmural CB at the inferior RA was associated with a higher incidence of post-operative AF (P=0.03). EEA occurred up to 84 ms and was more pronounced at the superior RA (superior: 27 ms [interquartile range, 18.3-39.3], versus mid-RA: 20.3 ms [interquartile range, 0-29.9], and inferior RA: 0 ms [interquartile range, 0-21], P<0.001). Hypertension (P=0.009), diabetes mellitus (P=0.018), and hypercholesterolemia (P=0.015) were associated with a higher degree of EEA. CB (P=0.007) and EEA (P=0.037) were more pronounced in patients with a history of persistent AF compared with patients without AF history. Conclusions This study provides important insights into complex atrial endo-epicardial excitation. Significant differences in conduction disorders between the endo- and epicardium and a significant degree of EEA are already present during sinus rhythm and are more pronounced in patients with cardiovascular risk factors or a history of persistent AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Mapeamento Epicárdico/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Doença do Sistema de Condução Cardíaco/fisiopatologia , Complicações do Diabetes/fisiopatologia , Eletrofisiologia/métodos , Endocárdio/fisiopatologia , Feminino , Bloqueio Cardíaco/fisiopatologia , Fatores de Risco de Doenças Cardíacas , Humanos , Hipercolesterolemia/complicações , Hipercolesterolemia/fisiopatologia , Hipertensão/complicações , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Índice de Gravidade de Doença
8.
Eur Heart J Digit Health ; 1(1): 62-70, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36713960

RESUMO

Aims: Increased complexity in cardiac surgery over the last decades necessitates more precise preoperative planning to minimize operating time, to limit the risk of complications during surgery and to aim for the best possible patient outcome. Novel, more realistic, and more immersive techniques, such as three-dimensional (3D) virtual reality (VR) could potentially contribute to the preoperative planning phase. This study shows our initial experience on the implementation of immersive VR technology as a complementary research-based imaging tool for preoperative planning in cardiothoracic surgery. In addition, essentials to set up and implement a VR platform are described. Methods: Six patients who underwent cardiac surgery at the Erasmus Medical Center, Rotterdam, The Netherlands, between March 2020 and August 2020, were included, based on request by the surgeon and availability of computed tomography images. After 3D VR rendering and 3D segmentation of specific structures, the reconstruction was analysed via a head mount display. All participating surgeons (n = 5) filled out a questionnaire to evaluate the use of VR as preoperative planning tool for surgery. Conclusion: Our study demonstrates that immersive 3D VR visualization of anatomy might be beneficial as a supplementary preoperative planning tool for cardiothoracic surgery, and further research on this topic may be considered to implement this innovative tool in daily clinical practice. Lay summary: Over the past decades, surgery on the heart and vessels is becoming more and more complex, necessitating more precise and accurate preoperative planning. Nowadays, operative planning is feasible on flat, two-dimensional computer screens, however, requiring a lot of spatial and three-dimensional (3D) thinking of the surgeon. Since immersive 3D virtual reality (VR) is an upcoming imaging technique with promising results in other fields of surgery, we aimed in this study to explore the additional value of this technique in heart surgery. Our surgeons planned six different heart operations by visualizing computed tomography scans with a dedicated VR headset, enabling them to visualize the patient's anatomy in an immersive and 3D environment. The outcomes of this preliminary study are positive, with a much more reality-like simulation for the surgeon. In such, VR could potentially be beneficial as a preoperative planning tool for complex heart surgery.

9.
Eur Heart J Qual Care Clin Outcomes ; 6(1): 10-18, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31287501

RESUMO

AIMS: This study aims to provide a contemporary overview of outcomes after tricuspid valve (TV) surgery for functional tricuspid regurgitation (TR). METHODS AND RESULTS: The literature was systematically searched for papers published between January 2005 and December 2017 reporting on clinical/echocardiographic outcomes after TV surgery for functional TR. A random effects meta-analysis was conducted for outcome variables, and late outcomes are visualized by pooled Kaplan-Meier curves. Subgroup analyses were performed for studies with a within-study comparison of suture vs. ring repair and flexible vs. rigid ring repair. Eighty-seven publications were included, encompassing 13 184 patients (mean age: 62.1 ± 11.8 years, 55% females). A mitral valve procedure was performed in 92% of patients. Pooled mean follow-up was 4.0 ± 2.8 years. Pooled early mortality was 3.9% (95% CI: 3.2-4.6), and late mortality rate was 2.7%/year (95% CI: 2.0-3.5), of which approximately half was cardiac-related 1.2%/year (95% CI: 0.8-1.9). Pooled risk of early moderate-to-severe TR at discharge was 9.4% (95% CI: 7.0-12.1). Late moderate-to-severe TR rate after discharge was 1.9%/year (95% CI: 1.0-3.5). Late reintervention rate was 0.3%/year (95% CI: 0.2-0.4). Mortality and overall (early and late) TR rate were comparable between suture vs. ring annuloplasty (14 studies), whereas overall TR rate was higher after flexible ring vs. rigid ring annuloplasty (6 studies) (7.5%/year vs. 3.9%/year, P = 0.002). CONCLUSION: This study shows that patients undergoing surgery for functional tricuspid regurgitation (FTR) have an acceptable early and late mortality. However, TR remains prevalent after surgery. The results of this study can be used to inform patients and clinicians about the expected outcome after surgery for FTR and can results serve as a benchmark for the performance of emerging transcatheter TV interventions.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Função Ventricular/fisiologia , Humanos , Fatores de Risco , Resultado do Tratamento , Insuficiência da Valva Tricúspide/fisiopatologia
10.
Eur Heart J ; 41(20): 1932-1940, 2020 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-31511897

RESUMO

Tricuspid regurgitation (TR) is a frequent and complex problem, commonly combined with left-sided heart disease, such as mitral regurgitation. Significant TR is associated with increased mortality if left untreated or recurrent after therapy. Tricuspid regurgitation was historically often disregarded and remained undertreated. Surgery is currently the only Class I Guideline recommended therapy for TR, in the form of annuloplasty, leaflet repair, or valve replacement. As growing experience of transcatheter therapy in structural heart disease, many dedicated transcatheter tricuspid repair or replacement devices, which mimic well-established surgical techniques, are currently under development. Nevertheless, many aspects of TR are little understood, including the disease process, surgical or interventional risk stratification, and predictors of successful therapy. The optimal treatment timing and the choice of proper surgical or interventional technique for significant TR remain to be elucidated. In this context, we aim to highlight the current evidence, underline major controversial issues in this field and present a future roadmap for TR therapy.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
11.
Interact Cardiovasc Thorac Surg ; 28(1): 108-111, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29986014

RESUMO

Mapping of the unorganized activation patterns of atrial fibrillation requires a high-resolution mapping approach to diagnose substrate-mediated pathophysiological mechanisms. At present, epicardial mapping is the only approach that is able to acquire electrograms of >200 high-density sites simultaneously. This study introduces a technique to perform high-resolution mapping in minimally invasive surgery. In 3 patients with mitral valve disease, epicardial mapping of the right atrium, Bachmann's bundle and parts of the left atrium was safely performed via minimal right thoracotomy.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Mapeamento Epicárdico/métodos , Sistema de Condução Cardíaco/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Valva Mitral/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Átrios do Coração/fisiopatologia , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade
12.
Circ Arrhythm Electrophysiol ; 9(5): e003972, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27153879

RESUMO

BACKGROUND: Bachmann's bundle (BB) is considered to be the main route of interatrial conduction and to play a role in development of atrial fibrillation (AF). The goals of this study are to characterize the presence of conduction disorders in BB during sinus rhythm and to study their relation with AF. METHODS AND RESULTS: High-resolution epicardial mapping (192 unipolar electrodes, interelectrode distance: 2 mm) of sinus rhythm was performed in 185 patients during coronary artery bypass surgery of whom 13 had a history of paroxysmal AF. Continuous rhythm monitoring was used to detect postoperative AF during the first 5 postoperative days. In 67% of the patients, BB was activated from right to left; in the remaining patients from right and middle (21%), right, central, and left (8%), or central (4%) site. Mean effective conduction velocity was 89 cm/s. Conduction block was present in most patients (75%; median 1.1%, range 0-12.8) and was higher in patients with paroxysmal AF compared with patients without a history of AF (3.2% versus 0.9%; P=0.03). A high amount of conduction block (>4%) was associated with de novo postoperative AF (P=0.02). Longitudinal lines of conduction block >10 mm were also associated with postoperative AF (P=0.04). CONCLUSIONS: BB may be activated through multiple directions, but the predominant route of conduction is from right to left. Conduction velocity across BB is around 90 cm/s. Conduction is blocked in both longitudinal and transverse direction in the majority of patients. Conduction disorders, particularly long lines of longitudinal conduction block, are more pronounced in patients with AF episodes.


Assuntos
Fibrilação Atrial/fisiopatologia , Fascículo Atrioventricular/fisiopatologia , Eletrodos Implantados , Mapeamento Epicárdico/instrumentação , Frequência Cardíaca/fisiologia , Processamento de Sinais Assistido por Computador , Taquicardia Paroxística/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Taquicardia Paroxística/diagnóstico
13.
Int J Cardiovasc Imaging ; 32(8): 1171-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27168076

RESUMO

Contradiction exists on the incremental value of two-dimensional (2D) and 3D transoesophageal echocardiography (TOE) over 2D transthoracic echocardiography (TTE) for the detection of mitral valve (MV) prolapse in readers with different echocardiographic experience. Twenty patients and five healthy persons were retrospectively identified who had undergone 2D-TTE, 2D-TOE and 3D-TOE. Fifteen (75 %) patients had surgical evidence of prolapse of the posterior MV leaflet and five patients (25 %) had a dilated MV annulus without prolapse. Three reader groups with different echocardiographic expertise (novice, trainees, cardiologists) scored thus in total 675 posterior scallops. Overall there was an improvement in agreement and Kappa values from novice to trainees to cardiologists. Diagnostic accuracies of 2D-TOE were higher than those of 2D-TTE mainly in novice readers. The incremental value of 3D-TOE over 2D-TOE was mainly seen in specificities. Time to diagnosis was dramatically reduced from 2D to 3D-TEE in all reader groups (all P < 0.001). 3D-TOE also improved the agreement (+12 to +16 %) and Kappa values (+0.14 to +0.21) in all reader groups for the exact description of P2 prolapse. Differences between readers with variable experience in determining the precise localization and extent of the prolapsing posterior MV scallops exist in particular in 2D-TTE analysis. 3D-TOE analysis was extremely fast compared to the 2D analysis methods and showed the best diagnostic accuracy (mainly driven by specificity) with identification of P1 and P3 prolapse still improving from novice to trainees to cardiologists and provided optimal description of P2 prolapse extent.


Assuntos
Competência Clínica , Ecocardiografia Tridimensional , Prolapso da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Diagnóstico Tardio , Feminino , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
14.
J Cardiovasc Transl Res ; 9(3): 194-201, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26935733

RESUMO

The heterogeneous presentation and progression of atrial fibrillation (AF) implicate the existence of different pathophysiological processes. Individualized diagnosis and therapy of the arrhythmogenic substrate underlying AF may be required to improve treatment outcomes. Therefore, this single-center study aims to identify the arrhythmogenic areas underlying AF by intra-operative, high-resolution, multi-site epicardial mapping in 600 patients with different heart diseases. Participants are divided into 12 groups according to the underlying heart diseases and presence of prior AF episodes. Mapping is performed with a 192-electrode array for 5-10 s during sinus rhythm and (induced) AF of the entire atrial surface. Local activation times are converted into activation and wave maps from which various electrophysiological parameters are derived. Postoperative cardiac rhythm registrations and a 5-year follow-up will show the incidence of postoperative and persistent AF. This project provides the first step in the development of a tool for individual AF diagnosis and treatment.


Assuntos
Fibrilação Atrial/diagnóstico , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Mapeamento Epicárdico , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Função Atrial , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte de Artéria Coronária/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Cardiopatias Congênitas/cirurgia , Frequência Cardíaca , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Países Baixos , Valor Preditivo dos Testes , Projetos de Pesquisa , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
15.
J Interv Card Electrophysiol ; 44(3): 221-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26497659

RESUMO

PURPOSE: A new technique is demonstrated for extensive high-resolution intra-operative atrial mapping that will facilitate the localization of atrial fibrillation (AF) sources and identification of the substrate perpetuating AF. METHODS: Prior to the start of extra-corporal circulation, a 8 × 24-electrode array (2-mm inter-electrode distance) is placed subsequently on all the right and left epicardial atrial sites, including Bachmann's bundle, for recording of unipolar electrograms during sinus rhythm and (induced) AF. AF is induced by high-frequency pacing at the right atrial free wall. A pacemaker wire stitched to the right atrium serves as a reference signal. The indifferent pole is connected to a steal wire fixed to subcutaneous tissue. Electrograms are recorded by a computerized mapping system and, after amplification (gain 1000), filtering (bandwidth 0.5-400 Hz), sampling (1 kHz) and analogue to digital conversion (16 bits), automatically stored on hard disk. During the mapping procedure, real-time visualization secures electrogram quality. Analysis will be performed offline. RESULTS: This technique was performed in 168 patients of 18 years and older, with coronary and/or structural heart disease, with or without AF, electively scheduled for cardiac surgery and a ventricular ejection fraction above 40 %. The mean duration of the entire mapping procedure including preparation time was 9 ± 2 min. Complications related to the mapping procedure during or after cardiac surgery were not observed. CONCLUSIONS: We introduce the first epicardial atrial mapping approach with a high resolution of ≥1728 recording sites which can be performed in a procedure time of only 9±2 mins. This mapping technique can potentially identify areas responsible for initiation and persistence of AF and hopefully can individualize both diagnosis and therapy of AF.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Aumento da Imagem/instrumentação , Monitorização Intraoperatória/instrumentação , Cirurgia Assistida por Computador/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrodos Implantados , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Átrios do Coração , Humanos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Análise em Microsséries/instrumentação , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
16.
Multimed Man Cardiothorac Surg ; 2014: mmu002, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24618339

RESUMO

Atrial septal defect (ASD) is the most common congenital cardiac disorder requiring intervention. Nowadays, most defects are closed percutaneously, but there will always remain defects that have to be closed surgically. In the past, techniques other than the standard median sternotomy approach have been advocated such as axial thoracotomy, lateral thoracotomy and limited sternotomy. In the last years, an increasing number of techniques of video-assisted mini-thoracotomy or full thoracoscopic methods including robotic-assisted operations have been described. Here, we describe and illustrate our experience with a video-assisted approach using femoral cannulation and a small thoracotomy for closure of an ASD. With this method, it is easy to perform a (additional) tricuspid valve operation at the same time, should this be indicated.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interatrial/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Complicações Pós-Operatórias/prevenção & controle , Implantação de Prótese , Cirurgia Torácica Vídeoassistida , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/métodos , Cateterismo Periférico , Ecocardiografia , Artéria Femoral/cirurgia , Comunicação Interatrial/diagnóstico , Humanos , Cuidados Intraoperatórios/métodos , Países Baixos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Reprodutibilidade dos Testes , Dispositivo para Oclusão Septal , Cirurgia Torácica Vídeoassistida/efeitos adversos , Cirurgia Torácica Vídeoassistida/instrumentação , Cirurgia Torácica Vídeoassistida/métodos , Toracotomia/métodos , Resultado do Tratamento
17.
J Heart Valve Dis ; 23(6): 721-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25790619

RESUMO

BACKGROUND AND AIM OF THE STUDY: Mitral regurgitation (MR) is a common disorder for which mitral valve surgery is an established therapy. Although surgical indications are clearly defined for the management of valvular heart disease, a gap exists between current guidelines and their effective application. The study aim was to provide an insight into the diagnostic information provided for cardiac surgeons before performing mitral valve surgery. METHODS: The source documents and echocardiographic studies of 100 patients, referred by nine hospitals, were screened for arguments for MR severity justifying referral for surgery. Details of the documented MR mechanism, mitral annulus (MA) size, tricuspid regurgitation (TR) severity and annulus size were also noted. RESULTS: According to the referring physician, MR was severe in 83% and moderate-to-severe in 17%. In the great majority of patients (98%) the MR mechanism was mentioned, although specific information on the prolapsing scallops was available in only 17% of cases. The recommended primary determinants of MR severity, vena contracta and proximal isovelocity surface area (PISA) were measured in only 22% and 31% of patients, respectively. In 94% of patients with available PISA information this was described only qualitatively. Correct image expansion using the zoom mode was performed in only 25% of these patients, and a correct adaptation of the Nyquist limit in only 6%. Tricuspid annulus measurements guiding the need for concomitant tricuspid valvuloplasty in patients with less than severe TR were reported in only 6% of patients. CONCLUSION: These data demonstrate a clear and important gap between current guidelines and real-world practice with regards to the echocardiographic diagnostic information provided to the surgeon before performing mitral valve surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Fidelidade a Diretrizes , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Idoso , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Avaliação das Necessidades , Países Baixos , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Encaminhamento e Consulta , Índice de Gravidade de Doença , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
18.
J Cardiothorac Surg ; 7: 109, 2012 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-23046536

RESUMO

We describe a patient with acute cardiogenic shock due to cardiac involvement in idiopathic hypereosinophilic syndrome (Löffler endocarditis). At the echocardiography, there was a huge mass in the left ventricular cavity, resulting in inflow- and outflow tract obstruction. The posterior leaflet of the mitral valve apparatus was completely embedded in a big (organized) thrombus mass. The patient was treated with high dose corticosteroids, however without effect. Partial remission was achieved after treatment with hydroxycarbamide. He was also treated with anticoagulants and high dose beta-blockers. The patient's condition improved remarkably after correction of the mitral valve insufficiency by a mitral valve bioprosthesis.


Assuntos
Insuficiência Cardíaca/etiologia , Síndrome Hipereosinofílica/diagnóstico , Trombose/diagnóstico , Adulto , Implante de Prótese de Valva Cardíaca , Humanos , Síndrome Hipereosinofílica/complicações , Síndrome Hipereosinofílica/tratamento farmacológico , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Trombose/complicações , Trombose/cirurgia
20.
Hum Immunol ; 63(11): 1019-25, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12392854

RESUMO

Cryopreserved human heart valves are used for valve replacement in patients with congenital or acquired heart disease. Although no blood group or human leukocyte antigens (HLA) matching is performed and no immunosuppression is administered, the clinical results are relatively good. After valve replacement, the majority of the patients develop HLA antibodies, whereas a smaller group of patients shows valve-related events at the long term after right ventricular outflow tract reconstruction. Therefore, we hypothesized that not the mere presence, but rather the titers of antidonor HLA antibodies may be related to valve allograft failure. The presence and specificity of HLA class I antibodies were determined by complement-dependent microlymphocytotoxicity (CDC) test in longitudinally taken peripheral blood samples of 35 valve allograft recipients. In eight patients with an antibody response specific against donor-HLA class I, the titers were measured by this CDC method after stepwise dilution of the plasma. Panel reactive antibodies of more than 10% were found in 31 of 35 (89%) valve allograft recipients. From these 31 patients, 24 (77%) developed donor-specific HLA class I antibodies. All eight selected patients had detectable donor-specific antibody titers, ranging from 1:2 to 1:8,000. Two donor valve recipients before retransplantation had (donor-specific) HLA antibodies and showed high titers of 1:256 and 1:8,000 shortly after the second allograft valve replacement, which was associated with an early graft failure in the latter patient. We conclude that transplantation of cryopreserved human heart valve allografts leads to a broad and strong humoral response, which is probably the result of a lack of immunosuppressive therapy after valve transplantation. Patients receiving a second or following valve allograft appeared to be sensitized and developed early and high allo-antibody titers after second valve allograft implantation. Valve failure was diagnosed in a patient with extremely high titers. These findings suggest that preoperative cross-matching may identify patients with high donor-specific HLA antibody titers and may reduce the risk for early recurrent graft failure.


Assuntos
Antígenos HLA/imunologia , Valvas Cardíacas/transplante , Isoanticorpos/biossíntese , Adolescente , Adulto , Idoso , Especificidade de Anticorpos , Criança , Pré-Escolar , Criopreservação , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Doadores de Tecidos , Transplante Homólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA