RESUMO
A novel Imaging Neutral Particle Analyzer (INPA) was newly installed in early 2024 to enhance the understanding of fast ion confinement on Large Helical Devices (LHDs). This diagnostic system, based on a magnetic spectrometer using a scintillator, provides energy-resolved radial profiles of confined fast ions by measuring charge-exchanged fast neutrals escaping from the plasma. The system utilizes a 100 nm thick carbon foil to ionize the fast neutrals, subsequently deflecting the ions toward a scintillator via the existing local magnetic field. The fast ion energy and sightline determine the position of the scintillation, while the light intensity depends on the flux of the fast ions. The INPA features two apertures, facilitating effective measurements in both clockwise and counterclockwise magnetic field directions in the LHD. This INPA was designed as a passive measurement system that measures fast ions charge exchange with background neutrals, focusing on perpendicular beam ions from 5 to 100 keV with an energy resolution of about 5.75 keV. This paper describes the details of the design, installation, and the initial results of the INPA on the LHD. This work will contribute significantly to a deeper understanding of fast ion transport due to magnetohydrodynamic instabilities.
RESUMO
For developing and characterizing a novel compact D-T neutron spectrometer based on a single-crystal chemical vapor deposition diamond stack for plasma diagnostics toward future D-T fusion reactors, the initial measurement was performed using the accelerator-based D-T neutron sources OKTAVIAN at Osaka University. This neutron spectrometer was designed for the detection of 3-17 MeV neutrons and operated in the proton recoil telescope configuration by installing a polyethylene converter in front of the diamond stack. The measured neutron energy spectra were obtained by summing the energy of the recoil protons deposited in the diamond stack after the coincidence of the recoil protons identified by the time coincidence analysis. The neutron energy peaks measured by the compact D-T neutron spectrometer were almost in agreement with those obtained by the Monte Carlo N-Particle transport (MCNP) simulation. The energy resolution of the compact D-T neutron spectrometer was emulated to be about 4%-5% in D-T neutron measurement. In future work, the design of the compact D-T neutron spectrometer would be optimized to measure the fusion neutron for plasma diagnostics.
RESUMO
A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m2 along with additional transient heat loads of 100 kW/m2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 1013 (s-1 cm-2) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. These simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.
RESUMO
OBJECTIVE: This study aimed to quantitatively investigate airborne particle load in the operating room during endoscopic or microscopic epitympanectomy or mastoidectomy. METHOD: In the transcanal endoscopic ear surgery group, drilling was performed underwater. A particle counter was used to measure the particle load before, during and after drilling during transcanal endoscopic ear surgery or microscopic ear surgery. The device counted the numbers of airborne particles of 0.3, 0.5 or 1.0 µm in diameter. RESULTS: The particle load during drilling was significantly higher in the microscopic ear surgery group (n = 5) than in the transcanal endoscopic ear surgery group (n = 11) for all particle sizes (p < 0.01). In the transcanal endoscopic ear surgery group, no significant differences among the particle load observed before, during and after drilling were seen for any of the particle sizes. CONCLUSION: Bone dissection carries a lower risk of airborne infection if it is performed using the endoscopic underwater drilling technique.
Assuntos
Salas Cirúrgicas , Procedimentos Cirúrgicos Otológicos , Humanos , Procedimentos Cirúrgicos Otológicos/métodos , Endoscopia/métodos , Mastoidectomia , Dissecação , Estudos RetrospectivosRESUMO
A fast-sampling fast-ion D-alpha (F-FIDA) measurement has been developed in the large helical device in order to investigate fast ion dynamics associated with helically trapped fast-ion-driven Magnetohydrodynamic (MHD) bursts. F-FIDA consists of a multi-anode photomultiplier tube (PMT) and achieves a sampling rate of 10 kHz. During the deuterium experiment campaign in 2022, F-FIDA measured the spectrum of perpendicular fast ions, using perpendicular lines of sight. We compared F-FIDA with conventional FIDA, using an electron multiplying charge coupled device, and confirmed that the time-averaged images were generally consistent between the two. The statistical properties of the temporal evolution associated with MHD bursts were analyzed using a conditional sampling technique. The results showed that the PMT signal varied in different spatial and wavelength channels. Although the signal-to-noise ratio was poor and there was room for improvement, it could provide useful information for studies on the phase-space dynamics of fast ions.
RESUMO
Fast ions play a crucial role in plasma heating, and their behavior in the plasma must be accurately understood. A diagnostics method based on charge exchange emission from the n = 4 - 3 transition (λ0 = 468.6 nm) of energetic 3He produced by the deuteron-deuteron reaction has been proposed as a for fast deuterons with energies in the order of MeV. The proposed method has the following advantages: No beam emission interferes with the spectra, the direction of the measuring line of sight, and the injection angle of the diagnostic beam can be freely determined. In previous studies, due to competing bremsstrahlung, it was expected that the proposed method will not be practical in the case of high electron density operation. This paper makes the proposed method available for measurement even at high electron densities by optimizing the measurement line of sight direction and the diagnostic beam incidence angle. This allows an electron density five times larger than the range of applications shown in previous studies. This result will contribute to measure of DT alpha in ITER.
RESUMO
BACKGROUND: The effectiveness of moisturizers in preventing infant atopic dermatitis (AD) remains unclear. We previously showed that using 2e moisturizer of commercial moisturizer (Shiseido Japan Co., Ltd.) at least once a day significantly prevented AD in infants as compared with as-needed petroleum jelly. This trial aimed to determine the effectiveness of twice- or once-daily application of Fam's Baby moisturizer (Fam's Inc.) in preventing AD compared with once-daily 2e moisturizer. METHODS: This trial was a single-centre, three-parallel-group, assessor-blinded, superiority, individually randomized, controlled, phase II trial that was conducted from 25 August 2020 to 28 September 2021. We randomly assigned 60 newborns with at least one parent or sibling who has AD to receive Fam's Baby moisturizer twice daily (Group A) or once daily (Group B), or 2e once daily (Group C) in a 1:1:1 ratio until they were 32 weeks old. The primary outcome was the time of AD onset. RESULTS: Atopic dermatitis was observed in 11/20 (55%), 5/20 (25%) and 10/20 (50%), infants in Groups A, B and C, respectively. Cumulative incidence values for AD according to the Kaplan-Meier method showed that infants in Group B tended to maintain an intact skin for a longer period than those in Group C (median time, not reached [NR] vs. 212 days, log-rank test, p = 0.064). Cox regression analysis showed that the risk of AD tended to be lower in Group B (hazard ratio with group C as control, 0.36; 95% confidential intervals: 0.12-1.06). No serious adverse events occurred in any of the enrolled infants. CONCLUSION: Fam's Baby moisturizer may better prevent AD than 2e. Further large-scale trials should be performed to confirm the efficacy of Fam's Baby moisturizer in preventing AD in infants.
Assuntos
Dermatite Atópica , Humanos , Recém-Nascido , Dermatite Atópica/tratamento farmacológico , Dermatite Atópica/prevenção & controle , Emolientes/uso terapêutico , Incidência , Vaselina , Resultado do TratamentoRESUMO
OBJECTIVES: Preserving sufficient oral function and maintaining aadequate nutrition are essential for preventing physical frailty and the following long-term care. We recently developed the 6-month Comprehensive Awareness Modification of Mouth, Chewing And Meal (CAMCAM) program, in which participants gather monthly to learn about oral health and nutrition while eating a textured lunch together. This study examined whether the CAMCAM program could improve attitude and behavior towards oral health, mastication, and diet as well as ameliorate oral frailty in community-dwelling older adults. DESIGN: Single-arm pre-post comparison study. SETTING AND PARTICIPANTS: A total of 271 community-dwelling adults (72.3 ± 5.7 years of age; 159 women [58.7%]) in 4 Japanese municipalities were recruited, of which 249 participants (92%) were assessed at the final evaluation. INTERVENTION: Participants gathered once a month at community centers to learn about oral health and nutrition while eating a "munchy" textured lunch containing proper nutrition. MEASUREMENTS: Oral frailty, frailty, and eating behavior were evaluated with the Oral Frailty Index-8 (OFI-8), Kihon checklist (KCL), and CAMCAM checklist, respectively. Participants were divided into Oral frailty (OF) and Robust groups according to OFI-8 scores. The differences in KCL and CAMCAM checklist results between the OF and Robust groups were statistically tested along with changes in scores after the program. RESULTS: KCL and CAMCAM checklist scores were significantly lower in the OF group at the initial assessment. OFI-8 and KCL findings were significantly improved in the OF group after completing the program (all P <0.05). Regarding the CAMCAM checklist, awareness of chewing improved significantly in the Robust group (P=0.009), with a similar tendency in the OF group (P=0.080). CONCLUSION: The findings of this pilot study suggest that the CAMCAM program may improve both oral and systemic frailty in addition to attitudes towards chewing, oral health, and meals, especially in individuals with oral frailty. The CAMCAM program merits expansion as a community-based frailty prevention program.
Assuntos
Fragilidade , Humanos , Feminino , Idoso , Fragilidade/prevenção & controle , Mastigação , Projetos Piloto , Saúde Bucal , Comportamento Alimentar , Boca , Refeições , Vida Independente , Atitude , Idoso Fragilizado , Japão , Avaliação GeriátricaRESUMO
The recently discovered kagome superconductors AV3Sb5 (A = K, Rb, Cs) exhibit unusual charge-density-wave (CDW) orders with time-reversal and rotational symmetry breaking. One of the most crucial unresolved issues is identifying the symmetry of the superconductivity that develops inside the CDW phase. Theory predicts a variety of unconventional superconducting symmetries with sign-changing and chiral order parameters. Experimentally, however, superconducting phase information in AV3Sb5 is still lacking. Here we report the impurity effects in CsV3Sb5 using electron irradiation as a phase-sensitive probe of superconductivity. Our magnetic penetration depth measurements reveal that with increasing impurities, an anisotropic fully-gapped state changes to an isotropic full-gap state without passing through a nodal state. Furthermore, transport measurements under pressure show that the double superconducting dome in the pressure-temperature phase diagram survives against sufficient impurities. These results support that CsV3Sb5 is a non-chiral, anisotropic s-wave superconductor with no sign change both at ambient and under pressure.
RESUMO
Proton-boron (p11B) fusion is an attractive potential energy source but technically challenging to implement. Developing techniques to realize its potential requires first developing the experimental capability to produce p11B fusion in the magnetically-confined, thermonuclear plasma environment. Here we report clear experimental measurements supported by simulation of p11B fusion with high-energy neutral beams and boron powder injection in a high-temperature fusion plasma (the Large Helical Device) that have resulted in diagnostically significant levels of alpha particle emission. The injection of boron powder into the plasma edge results in boron accumulation in the core. Three 2 MW, 160 kV hydrogen neutral beam injectors create a large population of well-confined, high -energy protons to react with the boron plasma. The fusion products, MeV alpha particles, are measured with a custom designed particle detector which gives a fusion rate in very good relative agreement with calculations of the global rate. This is the first such realization of p11B fusion in a magnetically confined plasma.
RESUMO
The perpendicular line-of-sight compact neutron emission spectrometer (perpendicular CNES) was newly installed to understand the helically trapped fast-ion behavior through deuterium-deuterium (D-D) neutron energy spectrum measurement in the Large Helical Device (LHD). The energy calibration of the EJ-301 liquid scintillation detector system for perpendicular CNES was performed on an accelerator-based D-D neutron source. We installed two EJ-301 liquid scintillation detectors, which view the LHD plasma vertically from the lower side through the multichannel collimator. The D-D neutron energy spectrum was measured in a deuterium perpendicular-neutral-beam-heated deuterium plasma. By the derivative unfolding technique, it was found that the D-D neutron energy spectrum had a double-humped shape with peaks at â¼2.33 and â¼2.65 MeV. D-D neutron energy spectrum was calculated based on the fast ion distribution function using guiding center orbit-following models considering the detector's energy resolution. The calculated peak energies in the D-D neutron energy spectrum almost match the experiment. In addition, a feasibility study toward the measurement of the energy distribution of ion-cyclotron-range-of-frequency-wave-accelerated beam ions was performed.
RESUMO
The Hayabusa2 spacecraft investigated the C-type (carbonaceous) asteroid (162173) Ryugu. The mission performed two landing operations to collect samples of surface and subsurface material, the latter exposed by an artificial impact. We present images of the second touchdown site, finding that ejecta from the impact crater was present at the sample location. Surface pebbles at both landing sites show morphological variations ranging from rugged to smooth, similar to Ryugu's boulders, and shapes from quasi-spherical to flattened. The samples were returned to Earth on 6 December 2020. We describe the morphology of >5 grams of returned pebbles and sand. Their diverse color, shape, and structure are consistent with the observed materials of Ryugu; we conclude that they are a representative sample of the asteroid.
RESUMO
The fast deuteron (non-Maxwellian component) diagnostic method, which is based on the higher resolution optical spectroscopic measurement, has been developed as a powerful tool. Owing to a decrease in the D-H charge-exchange cross section, the diagnostic ability of conventional optical diagnostic methods should be improved for â¼MeV energy deuterons. Because the 3He-H charge-exchange cross section is much larger than that of D-H in the â¼MeV energy range, the visible light (VIS) spectrum of 3He produced by the dueteron-dueteron (DD) reaction may be a useful tool. Although the density of 3He is small because it is produced via the DD reaction, improvement of the emissivity of the VIS spectrum of 3He can be expected by using a high-energy beam. We evaluate the VIS spectrum of 3He for the cases when a fast deuteron tail is formed and not formed in the ITER-like beam injected deuterium plasma. Even when the beam energy is in the MeV energy range, a large change appears in the half width at half maximum of the VIS spectrum. The emissivity of the VIS spectrum of 3He and the emissivity of bremsstrahlung are compared, and the measurable VIS spectrum is obtained. It is shown that the VIS spectrum of 3He is a useful tool for the MeV beam deuteron tail diagnostics.
RESUMO
The present study aimed to verify the changes in the expression levels of 13 candidate genes associated with chemotherapy resistance and to construct a scoring system to predict resistance to these drugs. The expression levels of the 13 candidate genes were compared between 20 dogs with lymphoma that were sensitive to drugs used in CHOP-based protocol and 16 dogs with lymphoma that were resistant to these drugs. The expression levels of six genes; ASNS, CCR3, CALCA, FCER1A, LOC448801, and EDNRB were significantly different between the two groups. A scoring system to predict resistance to cyclophosphamide, doxorubicin and vincristine, which are used in CHOP-based protocol, was constructed based on expression levels of the six genes in these 36 dogs using logistic regression models. After internal validation, sensitivity and specificity of the scoring system were 0.759 and 0.853, respectively. External validation was conducted in another cohort of 33 dogs with lymphoma, and sensitivity and specificity of the scoring system were 0.800 and 0.696, respectively. In conclusion, this study identified six genes associated with resistance to drugs used in CHOP-based protocol in canine lymphoma and proposed a novel scoring system to predict resistance to these drugs. This system might be beneficial in selecting the most appropriate chemotherapy protocol for individual dogs with lymphoma.
Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Doenças do Cão/tratamento farmacológico , Resistencia a Medicamentos Antineoplásicos/genética , Linfoma/veterinária , Transcriptoma , Animais , Estudos de Coortes , Ciclofosfamida/uso terapêutico , Cães , Doxorrubicina/uso terapêutico , Feminino , Linfoma/tratamento farmacológico , Masculino , Prednisona/uso terapêutico , Projetos de Pesquisa , Vincristina/uso terapêuticoRESUMO
BACKGROUND: During stapes surgery, the Teflon wire piston prosthesis is prone to postoperative 'slips' and subsequent necrosis and fracture of the long process of the incus. AIMS/OBJECTIVE: We invented and used a novel cup-shaped apatite prosthesis to reduce the incidence of necrosis of the long process of the incus and analysed the postoperative results. MATERIAL AND METHODS: Thirty-one ears in 25 patients with otosclerosis who underwent stapes surgery with our apatite prosthesis were evaluated. RESULTS: The air conduction improved by 24.0 dB (the average) from pre- to post-operation. Additionally, 84.8% of patients achieved an air-bone gap of ≤10 dB for the 4-frequency measurements (p < .01). CONCLUSIONS: Our findings indicate that our new prosthesis was associated with a good postoperative prognosis in patients with otosclerosis. SIGNIFICANCE: Our unique prosthesis yielded good outcomes for the treatment of otosclerosis even in the short term.
Assuntos
Condução Óssea/fisiologia , Microcirurgia/métodos , Prótese Ossicular , Otosclerose/cirurgia , Cirurgia do Estribo/métodos , Estribo , Feminino , Seguimentos , Audição , Humanos , Masculino , Pessoa de Meia-Idade , Otosclerose/fisiopatologia , Período Pós-Operatório , Desenho de Prótese , Estudos Retrospectivos , Fatores de TempoRESUMO
A diamond-based neutral particle analyzer (DNPA) array composed of single-crystal chemical vapor deposition (sCVD) diamond detectors was installed on the Large Helical Device (LHD) for measuring the helically trapped energetic particles. In high neutron flux experiments, the unwanted neutron-induced pulse counting rate should be estimated using the neutron diagnostics because a diamond detector is sensitive to neutrons as well as energetic neutral particles. In order to evaluate the quantitative neutron-induced pulse counting rate on the DNPA, the response functions of the sCVD diamond detector for mono-energetic neutrons were obtained using accelerator-based D-D and D-7Li neutron sources in Fast Neutron Laboratory (FNL). As a result of the neutron flux estimation by the Monte Carlo N-Particle code at the NPA position in the LHD and the response function obtained in the FNL experiment, the counting rate of the neutron-induced signal was predicted to be 1.1 kcps for the source neutron emission rate of Sn = 1 × 1015 n/s. In the LHD experiment, the neutron-induced signals were observed by closing the gate valve during the plasma discharges. It is found that the counting rates of the neutron-induced signals proportional to Sn reached 1.1 kcps at Sn = 1 × 1015 n/s. As a result of the quantitative estimation of the neutron-induced signals on the DNPA using other neutron measurements, it has become possible to accurately measure energetic neutral particles in the high neutron flux experiment.
RESUMO
Materials and structures of a collimator for a new neutron emission profile monitor in JT-60SA are examined through Monte Carlo simulations using the Monte Carlo N-Particle transport code. First, the shielding properties of various material combinations are compared in order to determine a combination with high shielding performances against both neutrons and gamma-rays. It is found that a collimator consisting of borated polyethylene and lead has a high shielding performance against neutrons. Moreover, a high shielding performance against gamma-rays is obtained when a lead pipe with a radial thickness of 0.01 m is inserted into a collimation tube. Second, we demonstrate that it is possible to improve the spatial resolution to a desired level by installing a thin tubular extension structure that fits into the limited space available between the main collimator block and the tokamak device. Finally, the collimator structures that meet both the targeted spatial resolutions (<10% of the plasma minor radius) and the targeted counting rate (105 cps order) are discussed.
RESUMO
Two new vertical neutron cameras characterized by high detection efficiency were developed on the Large Helical Device in order to observe poloidal structures of helically trapped beam ions created by the perpendicularly injected positive-ion based neutral beam (P-NB) and are newly operated since 2018. In this work, the neutron fields at the vertical neutron cameras are investigated using the Monte Carlo N-particle transport code to evaluate the performance of its collimators. The results indicate that neutrons are attenuated by the heavy concrete and are well collimated through the collimator to detectors. Neutron spectra at the detector position show over 99% of uncollided 2.45 MeV neutrons. Time evolution of neutron emission profiles during the short pulse of P-NB injection is measured by the vertical neutron cameras. Peaks on the neutron emission profiles corresponding to the helically trapped beam ion are successfully obtained, as designed. The decrease in line integrated neutron flux at the peak positions after the P-NB stops is consistent with the behavior of the total neutron emission rate measured by the neutron flux monitor.
RESUMO
The near-Earth asteroid (162173) Ryugu is thought to be a primitive carbonaceous object that contains hydrated minerals and organic molecules. We report sample collection from Ryugu's surface by the Hayabusa2 spacecraft on 21 February 2019. Touchdown images and global observations of surface colors are used to investigate the stratigraphy of the surface around the sample location and across Ryugu. Latitudinal color variations suggest the reddening of exposed surface material by solar heating and/or space weathering. Immediately after touchdown, Hayabusa2's thrusters disturbed dark, fine grains that originate from the redder materials. The stratigraphic relationship between identified craters and the redder material indicates that surface reddening occurred over a short period of time. We suggest that Ryugu previously experienced an orbital excursion near the Sun.