1.
Biomicrofluidics ; 17(1): 014106, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36704613

RESUMO

Herringbone micromixers are a powerful tool for introducing advection into microfluidic systems. While these mixers are typically used for mixing fluids faster than the rate of diffusion, there has been recent interest in using the device to enhance interactions between suspended particles and channel walls. We show how the common approximations applied to herringbone micromixer theory can have a significant impact on results. We show that the inclusion of gravity can greatly alter the interaction probability between suspended particles and channel walls. We also investigate the proposed impedance matching condition and the inclusion of imperfect binding using numerical methods, and investigate transient behaviors using an experimental system. These results indicate that while traditional methods, such as simple streamline analysis, remain powerful tools, it should not be considered predictive in the general case.

2.
J Appl Phys ; 132(16): 164701, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36313737

RESUMO

Integrating miniature pumps within microfluidic devices is crucial for advancing point-of-care diagnostics. Understanding the emergence of flow from novel integrated pumping systems is the first step in their successful implementation. A Purcell-like elasto-magnetic integrated microfluidic pump has been simulated in COMSOL Multiphysics and its performance has been investigated and evaluated. An elastic, cilia-like element contains an embedded magnet, which allows for actuation via a weak, uniaxial, sinusoidally oscillating, external magnetic field. Pumping performance is correlated against a number of variables, such as the frequency of the driving field and the proximity of the pump to the channel walls, in order to understand the emergence of the pumping behavior. Crucially, these simulations capture many of the trends observed experimentally and shed light on the key interactions. The proximity of the channel walls in the in-plane direction strongly determines the direction of net fluid flow. This characterization has important implications for the design and optimization of this pump in practical applications.

3.
Lab Chip ; 21(15): 3019-3020, 2021 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-34165486

RESUMO

Correction for 'Microfluidic devices powered by integrated elasto-magnetic pumps' by Jacob L. Binsley et al., Lab Chip, 2020, 20, 4285-4295, DOI: .

4.
ACS Nano ; 15(1): 387-395, 2021 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-33119252

RESUMO

Nanoscopic lamellae of centrosymmetric ferromagnetic alloys have recently been reported to host the biskyrmion spin texture; however, this has been disputed as the misidentication of topologically trivial type-II magnetic bubbles. Here we demonstrate resonant soft X-ray holographic imaging of topological magnetic states in lamellae of the centrosymmetric alloy (Mn1-xNix)0.65Ga0.35 (x = 0.5), showing the presence of magnetic stripes evolving into single core magnetic bubbles. We observe rotation of the stripe phase via the nucleation and destruction of disclination defects. This indicates the system behaves as a conventional uniaxial ferromagnet. By utilizing the holography with extended reference by autocorrelation linear differential operator (HERALDO) method, we show tilted holographic images at 30° incidence confirming the presence of type-II magnetic bubbles in this system. This study demonstrates the utility of X-ray imaging techniques in identifying the topology of localized structures in nanoscale magnetism.

5.
Lab Chip ; 20(22): 4285-4295, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-33094306

RESUMO

We show how an asymmetric elasto-magnetic system provides a novel integrated pumping solution for lab-on-a-chip and point of care devices. This monolithic pumping solution, inspired by Purcell's 3-link swimmer, is integrated within a simple microfluidic device, bypassing the requirement of external connections. We experimentally prove that this system can provide tuneable fluid flow with a flow rate of up to 600 µL h-1. This fluid flow is achieved by actuating the pump using a weak, uniform, uniaxial, oscillating magnetic field, with field amplitudes in the range of 3-6 mT. Crucially, the fluid flow can be reversed by adjusting the driving frequency. We experimentally prove that this device can successfully operate on fluids with a range of viscosities, where pumping at higher viscosity correlates with a decreasing optimal driving frequency. The fluid flow produced by this device is understood here by examining the non-reciprocal motion of the elasto-magnetic component. This device has the capability to replace external pumping systems with a simple, integrated, lab-on-a-chip component.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Fenômenos Magnéticos , Magnetismo , Viscosidade
6.
Nat Commun ; 10(1): 4696, 2019 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-31619673

RESUMO

Magnetic actuation is widely used in engineering specific forms of controlled motion in microfluidic applications. A challenge, however, is how to extract different desired responses from different components in the system using the same external magnetic drive. Using experiments, simulations, and theoretical arguments, we present emergent rotational patterns in an array of identical magnetic rotors under an uniform, oscillating magnetic field. By changing the relative strength of the external field strength versus the dipolar interactions between the rotors, different collective modes are selected by the rotors. When the dipole interaction is dominant the rotors swing upwards or downwards in alternating stripes, reflecting the spin-ice symmetry of the static configuration. For larger spacings, when the external field dominates over the dipolar interactions, the rotors undergo full rotations, with different quarters of the array turning in different directions. Our work sheds light on how collective behaviour can be engineered in magnetic systems.

7.
Adv Mater ; 31(16): e1806598, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30844122

RESUMO

The intense research effort investigating magnetic skyrmions and their applications for spintronics has yielded reports of more exotic objects including the biskyrmion, which consists of a bound pair of counter-rotating vortices of magnetization. Biskyrmions have been identified only from transmission electron microscopy images and have not been observed by other techniques, nor seen in simulations carried out under realistic conditions. Here, quantitative Lorentz transmission electron microscopy, X-ray holography, and micromagnetic simulations are combined to search for biskyrmions in MnNiGa, a material in which they have been reported. Only type-I and type-II magnetic bubbles are found and images purported to show biskyrmions can be explained as type-II bubbles viewed at an angle to their axes. It is not the magnetization but the magnetic flux density resulting from this object that forms the counter-rotating vortices.

8.
Sci Rep ; 8(1): 933, 2018 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-29343852

RESUMO

We propose a new class of magnetically actuated pumps and valves that could be incorporated into microfluidic chips with no further external connections. The idea is to repurpose ferromagnetic low Reynolds number swimmers as devices capable of generating fluid flow, by restricting the swimmers' translational degrees of freedom. We experimentally investigate the flow structure generated by a pinned swimmer in different scenarios, such as unrestricted flow around it as well as flow generated in straight, cross-shaped, Y-shaped and circular channels. This demonstrates the feasibility of incorporating the device into a channel and its capability of acting as a pump, valve and flow splitter. Different regimes could be selected by tuning the frequency and amplitude of the external magnetic field driving the swimmer, or by changing the channel orientation with respect to the field. This versatility endows the device with varied functionality which, together with the robust remote control and reproducibility, makes it a promising candidate for several applications.

9.
Sci Rep ; 7: 44142, 2017 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-28276490

RESUMO

Microscopic swimming devices hold promise for radically new applications in lab-on-a-chip and microfluidic technology, diagnostics and drug delivery etc. In this paper, we demonstrate the experimental verification of a new class of autonomous ferromagnetic swimming devices, actuated and controlled solely by an oscillating magnetic field. These devices are based on a pair of interacting ferromagnetic particles of different size and different anisotropic properties joined by an elastic link and actuated by an external time-dependent magnetic field. The net motion is generated through a combination of dipolar interparticle gradient forces, time-dependent torque and hydrodynamic coupling. We investigate the dynamic performance of a prototype (3.6 mm) of the ferromagnetic swimmer in fluids of different viscosity as a function of the external field parameters (frequency and amplitude) and demonstrate stable propulsion over a wide range of Reynolds numbers. We show that the direction of swimming has a dependence on both the frequency and amplitude of the applied external magnetic field, resulting in robust control over the speed and direction of propulsion. This paves the way to fabricating microscale devices for a variety of technological applications requiring reliable actuation and high degree of control.

10.
Opt Express ; 19(17): 16223-8, 2011 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-21934984

RESUMO

We demonstrate magnetic lensless imaging by Fourier transform holography using extended references. A narrow slit milled through an opaque gold mask is used as a holographic reference and magnetic contrast is obtained by x-ray magnetic circular dichroism. We present images of magnetic domains in a Co/Pt multilayer thin film with perpendicular magnetic anisotropy. This technique holds advantages over standard Fourier transform holography, where small holes are used to define the reference beam. An increased intensity through the extended reference reduces the counting time to record the farfield diffraction pattern. Additionally it was found that manufacturing narrow slits is less technologically demanding than the same procedure for holes. We achieve a spatial resolution of ∼30 nm, which was found to be limited by the sample period of the chosen experimental setup.

11.
Langmuir ; 26(13): 10677-83, 2010 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-20423068

RESUMO

We present results from an experimental study of ordering characteristics in monolayers of polystyrene nanospheres self-assembled at a water-air interface. We demonstrate that the interaction of spheres, governed by the dissemination of surface charge, leads to the formation of macroscopic close-packed ordered areas or "domains" with a well-defined orientation of the lattice axes over areas of 25 mm(2). It was found that by changing the surface chemistry of the spheres it is possible to modify the balance between the attractive and repulsive forces and thus to control the ordering characteristics. We implemented a model that simulates the process of self-assembly and examines the ordering characteristics for layers with different ratio between attractive and repulsive forces. A good qualitative agreement was found between the simulations and experiment. These studies are technologically relevant as a method of producing nanosphere templates for large area patterned materials.


Assuntos
Ar , Nanosferas/química , Poliestirenos/química , Água/química , Microscopia Eletrônica de Varredura , Nanosferas/ultraestrutura , Nanotecnologia
12.
J Biophotonics ; 2(3): 157-66, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19343696

RESUMO

We show that naturally occurring chitinous nanostructures found on the wings of the Graphium butterfly can be used as substrates for surface-enhanced Raman scattering when coated with a thin film of gold or silver. The substrates were found to exhibit excellent biocompatibility and sensitivity, making them ideal for protein assaying. An assay using avidin/biotin binding showed that the substrates could be used to quantify protein binding directly from changes in the surface-enhanced Raman scattering (SERS) spectra and were sensitive over a concentration range comparable with a typical enzyme-linked immunosorbent assays (ELISA) assay. A biomimetic version of the wing nanostructures produced using a highly reproducible, large-scale fabrication process, yielded comparable enhancement factors and biocompatibility. The excellent biocompatibility of the wings and biomimetic substrates is unparalleled by other lithographically produced substrates, and this could pave the way for widespread application of ultrasensitive SERS-based bioassays.


Assuntos
Lepidópteros/ultraestrutura , Análise Espectral Raman/métodos , Asas de Animais/ultraestrutura , Animais , Avidina , Biomimética , Biotina , Materiais Revestidos Biocompatíveis , Ouro , Microscopia Eletrônica de Varredura , Nanoestruturas , Prata , Propriedades de Superfície
13.
Phys Rev Lett ; 100(21): 218102, 2008 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-18518640

RESUMO

We propose a model for a novel artificial low Reynolds number swimmer, based on the magnetic interactions of a pair of ferromagnetic particles: one with hard and the other with soft magnetic properties, connected by a linear spring. Using a computational model, we analyze the behavior of the system and demonstrate that for realistic values of the parameters involved, the swimmer is capable of self-propelling with average speeds of the order of hundreds of micrometers per second.


Assuntos
Compostos Férricos , Modelos Teóricos , Anisotropia , DNA/química , Elasticidade , Flagelos/fisiologia , Polímeros/química , Proteínas/química
14.
Langmuir ; 23(3): 1057-60, 2007 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-17241014

RESUMO

We have extended the widely used technique of nanosphere lithography to produce nanosphere templates with significantly improved long-range order. Single, ordered domains stretching over areas greater than 1 cm2 have been achieved by assembling spheres with the correct surface chemistry on a water/air interface. Self-assembly over macroscopic areas is facilitated by a combination of electrostatic and capillary forces. The presented technique is easily implemented, and the assembled monolayers can be transferred onto almost any surface, thus making the procedure applicable to a broad range of nanoscale research. We demonstrate this through the fabrication of hexagonally ordered, macroscopic arrays of magnetic nanostructures with modified magnetic properties.

15.
Langmuir ; 20(25): 11208-12, 2004 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-15568877

RESUMO

Nanosphere lithography (NSL) is a simple, cost-effective, and powerful technique capable of producing large-area arrays of ferromagnetic nanostructures with dimensions below 100 nm. These properties make NSL an attractive process for the fabrication of arrays of magnetic elements with applications in magnetic data storage. The main disadvantage with conventional NSL is that the monolayer of spheres always contains imperfections that are transferred to the resulting nanostructures. This can significantly affect the structural and magnetic properties of the fabricated array. In this paper we present a novel adaptation of NSL that reduces the effect of such defects on the resulting nanostructures. The technique also offers excellent control over the diameter, aspect ratio, and pitch of the fabricated elements. These properties are demonstrated through the fabrication of arrays of Ni elements of 210 nm diameter and arrays of Co elements with diameters between 200 and 320 nm.