RESUMO
The structural morphology of coronary stents and the local hemodynamic environment following stent deployment in coronary arteries are crucial determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to facilitate geometrically accurate three-dimensional (3D) reconstruction of coronary stents. This work presents an innovative algorithm for the 3D reconstruction of coronary artery stents, leveraging intravascular ultrasound (IVUS) and angiography. The accuracy and reproducibility of our method were tested in stented patient-specific silicone models, with micro-computed tomography serving as a reference standard. We also evaluated the clinical feasibility and ability to perform computational fluid dynamics (CFD) studies in a clinically stented coronary bifurcation. Our experimental and clinical studies demonstrated that our proposed algorithm could reproduce the complex 3D stent configuration with a high degree of precision and reproducibility. Moreover, the algorithm was proved clinically feasible in cases with stents deployed in a diseased coronary artery bifurcation, enabling CFD studies to assess the hemodynamic environment. In combination with patient-specific CFD studies, our method can be applied to stenting optimization, training in stenting techniques, and advancements in stent research and development.
Assuntos
Doença da Artéria Coronariana , Vasos Coronários , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/anatomia & histologia , Microtomografia por Raio-X , Imageamento Tridimensional , Estudos de Viabilidade , Reprodutibilidade dos Testes , Stents , Ultrassonografia de Intervenção , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgiaRESUMO
Purpose: Optical coherence tomography has emerged as an important intracoronary imaging technique for coronary artery disease diagnosis as it produces high-resolution cross-sectional images of luminal and plaque morphology. Precise and fast lumen segmentation is essential for efficient OCT morphometric analysis. However, due to the presence of various image artifacts, including side branches, luminal blood artifacts, and complicated lesions, this remains a challenging task. Approach: Our research study proposes a rapid automatic segmentation method that utilizes nonuniform rational B-spline to connect limited pixel points and identify the edges of the OCT lumen. The proposed method suppresses image noise and accurately extracts the lumen border with a high correlation to ground truth images based on the area, minimal diameter, and maximal diameter. Results: We evaluated the method using 3300 OCT frames from 10 patients and found that it achieved favorable results. The average time taken for automatic segmentation by the proposed method is 0.17 s per frame. Additionally, the proposed method includes seamless vessel reconstruction following the lumen segmentation. Conclusions: The developed automated system provides an accurate, efficient, robust, and user-friendly platform for coronary lumen segmentation and reconstruction, which can pave the way for improved assessment of the coronary artery lumen morphology.
RESUMO
Artificial intelligence, computational simulations, and extended reality, among other 21st century computational technologies, are changing the health care system. To collectively highlight the most recent advances and benefits of artificial intelligence, computational simulations, and extended reality in cardiovascular therapies, we coined the abbreviation AISER. The review particularly focuses on the following applications of AISER: 1) preprocedural planning and clinical decision making; 2) virtual clinical trials, and cardiovascular device research, development, and regulatory approval; and 3) education and training of interventional health care professionals and medical technology innovators. We also discuss the obstacles and constraints associated with the application of AISER technologies, as well as the proposed solutions. Interventional health care professionals, computer scientists, biomedical engineers, experts in bioinformatics and visualization, the device industry, ethics committees, and regulatory agencies are expected to streamline the use of AISER technologies in cardiovascular interventions and medicine in general.
Assuntos
Inteligência Artificial , Humanos , Resultado do TratamentoRESUMO
Coronary bifurcation lesions represent a challenging anatomical subset, and the understanding of their 3D anatomy and plaque composition appears to play a key role in devising the optimal stenting strategy. This study proposes a new approach for the 3D reconstruction of coronary bifurcations and plaque materials by combining intravascular ultrasound (IVUS) and angiography. Three patient-specific silicone bifurcation models were 3D reconstructed and compared to micro-computed tomography (µCT) as the gold standard to test the accuracy and reproducibility of the proposed methodology. The clinical feasibility of the method was investigated in three diseased patient-specific bifurcations of varying anatomical complexity. The IVUS-based 3D reconstructed bifurcation models showed high agreement with the µCT reference models, with r2 values ranging from 0.88 to 0.99. The methodology successfully 3D reconstructed all the patient bifurcations, including plaque materials, in less than 60 min. Our proposed method is a simple, time-efficient, and user-friendly tool for accurate 3D reconstruction of coronary artery bifurcations. It can provide valuable information about bifurcation anatomy and plaque burden in the clinical setting, assisting in bifurcation stent planning and education.
Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Microtomografia por Raio-X , Ultrassonografia de Intervenção , Placa Aterosclerótica/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgiaRESUMO
This study sought to investigate the role of triggering receptor expressed on myeloid cells-1 (TREM-1) in the mechanotransduction signaling pathways that link low shear stress with inflammation. Human coronary artery endothelial cells, human coronary artery smooth muscle cells, and THP-1 monocytes were co-cultured and exposed to varying endothelial shear stress (ESS) conditions: low (5 ± 3 dynes/cm2), medium (10 ± 3 dynes/cm2), and high (15 ± 3 dynes/cm2). We showed that low ESS increased the expression of TREM-1 by the cultured cells leading to increased production of inflammatory mediators and matrix-degrading enzymes, whereas high ESS did not have a significant effect in the expression of TREM-1 and inflammatory mediators. Furthermore, TREM-1 transcriptional inhibition with siRNA in endothelial cells, smooth muscle cells, and monocytes exposed to low ESS, led to a significant reduction in the production of vascular inflammatory mediators and matrix-degrading enzymes. Additionally, we identified the transcription factors that appear to upregulate the TREM-1 gene expression in response to low ESS. To the best of our knowledge, this is the first study to investigate the pathophysiologic association and molecular pathways that link low ESS, TREM-1, and inflammation using a sophisticated in-vitro model of atherosclerosis. Future studies on animals and humans are warranted to investigate the potential of TREM-1 inhibitors as adjunctive anti-atherosclerotic therapies.
Assuntos
Aterosclerose , Mecanotransdução Celular , Transdução de Sinais , Receptor Gatilho 1 Expresso em Células Mieloides , Humanos , Aterosclerose/metabolismo , Células Endoteliais/metabolismo , Inflamação/metabolismo , Mediadores da Inflamação/metabolismo , Receptor Gatilho 1 Expresso em Células Mieloides/metabolismoRESUMO
INTRODUCTION: Coronary artery bypass graft surgery (CABG) is an intervention in patients with extensive obstructive coronary artery disease diagnosed with invasive coronary angiography. Here we present and test a novel application of non-invasive computational assessment of coronary hemodynamics before and after bypass grafting. METHODS AND RESULTS: We tested the computational CABG platform in n = 2 post-CABG patients. The computationally calculated fractional flow reserve showed high agreement with the angiography-based fractional flow reserve. Furthermore, we performed multiscale computational fluid dynamics simulations of pre- and post-CABG under simulated resting and hyperemic conditions in n = 2 patient-specific anatomies 3D reconstructed from coronary computed tomography angiography. We computationally created different degrees of stenosis in the left anterior descending artery, and we showed that increasing severity of native artery stenosis resulted in augmented flow through the graft and improvement of resting and hyperemic flow in the distal part of the grafted native artery. CONCLUSIONS: We presented a comprehensive patient-specific computational platform that can simulate the hemodynamic conditions before and after CABG and faithfully reproduce the hemodynamic effects of bypass grafting on the native coronary artery flow. Further clinical studies are warranted to validate this preliminary data.
Assuntos
Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Humanos , Constrição Patológica , Ponte de Artéria Coronária , Vasos Coronários , Angiografia CoronáriaRESUMO
BACKGROUND: This work aims to present a fast, affordable, and reproducible three-cell co-culture system that could represent the different cellular mechanisms of atherosclerosis, extending from atherogenesis to pathological intimal thickening. METHODS AND RESULTS: We built four culture models: (i) Culture model #1 (representing normal arterial intima), where human coronary artery endothelial cells were added on top of Matrigel-coated collagen type I matrix, (ii) Culture model #2 (representing atherogenesis), which demonstrated the subendothelial accumulation and oxidative modification of low-density lipoproteins (LDL), (iii) Culture model #3 (representing intimal xanthomas), which demonstrated the monocyte adhesion to the endothelial cell monolayer, transmigration into the subendothelial space, and transformation to lipid-laden macrophages, (iv) Culture model #4 (representing pathological intimal thickening), which incorporated multiple layers of human coronary artery smooth muscle cells within the matrix. Coupling this model with different shear stress conditions revealed the effect of low shear stress on the oxidative modification of LDL and the upregulation of pro-inflammatory molecules and matrix-degrading enzymes. Using electron microscopy, immunofluorescence confocal microscopy, protein and mRNA quantification assays, we showed that the behaviors exhibited by the endothelial cells, macrophages and vascular smooth muscle cells in these models were very similar to those exhibited by these cell types in nascent and intermediate atherosclerotic plaques in humans. The preparation time of the cultures was 24 hours. CONCLUSION: We present three-cell co-culture models of human atherosclerosis. These models have the potential to allow cost- and time-effective investigations of the mechanobiology of atherosclerosis and new anti-atherosclerotic drug therapies.