1.
Micromachines (Basel) ; 15(2)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38398969

RESUMO

A wax-based contact printing method to create microfluidic devices is demonstrated. This printing technology demonstrates a new pathway to rapid, cost-effective device prototyping, eliminating the use of expensive micromachining equipment and chemicals. Derived from the traditional Ukrainian Easter egg painting technique called "pysanky" a series of microfluidic devices were created. Pysanky is the use of a heated wax stylus, known as a "kistka", to create micro-sized, intricate designs on the surface of an egg. The proposed technique involves the modification of an x-y-z actuation translation system with a wax extruder tip in junction with Polydimethysiloxane (PDMS) device fabrication techniques. Initial system optimization was performed considering design parameters such as extruder tip size, contact angle, write speed, substrate temperature, and wax temperature. Channels created ranged from 160 to 900 µm wide and 10 to 150 µm high based upon system operating parameters set by the user. To prove the capabilities of this technology, a series of microfluidic mixers were created via the wax technique as well as through traditional photolithography: a spiral mixer, a rainbow mixer, and a linear serial dilutor. A thermo-fluidic computational fluid dynamic (CFD) model was generated as a means of enabling rational tuning, critical to the optimization of systems in both normal and extreme conditions. A comparison between the computational and experimental models yielded a wax height of 57.98 µm and 57.30 µm, respectively, and cross-sectional areas of 11,568 µm2 and 12,951 µm2, respectively, resulting in an error of 1.18% between the heights and 10.76% between the cross-sectional areas. The device's performance was then compared using both qualitative and quantitative measures, considering factors such as device performance, channel uniformity, repeatability, and resolution.

2.
J Biomed Opt ; 28(8): 080903, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37614568

RESUMO

Significance: Photoacoustic tomography has emerged as a prominent medical imaging technique that leverages its hybrid nature to provide deep penetration, high resolution, and exceptional optical contrast with notable applications in early cancer detection, functional brain imaging, drug delivery monitoring, and guiding interventional procedures. Test phantoms are pivotal in accelerating technology development and commercialization, specifically in photoacoustic (PA) imaging, and can be optimized to achieve significant advancements in PA imaging capabilities. Aim: The analysis of material properties, structural characteristics, and manufacturing methodologies of test phantoms from existing imaging technologies provides valuable insights into their applicability to PA imaging. This investigation enables a deeper understanding of how phantoms can be effectively employed in the context of PA imaging. Approach: Three primary categories of test phantoms (simple, intermediate, and advanced) have been developed to differentiate complexity and manufacturing requirements. In addition, four sub-categories (tube/channel, block, test target, and naturally occurring phantoms) have been identified to encompass the structural variations within these categories, resulting in a comprehensive classification system for test phantoms. Results: Based on a thorough examination of literature and studies on phantoms in various imaging modalities, proposals have been put forth for the development of multiple PA-capable phantoms, encompassing considerations related to the material composition, structural design, and specific applications within each sub-category. Conclusions: The advancement of novel and sophisticated test phantoms within each sub-category is poised to foster substantial progress in both the commercialization and development of PA imaging. Moreover, the continued refinement of test phantoms will enable the exploration of new applications and use cases for PA imaging.


Assuntos
Sistemas de Liberação de Medicamentos , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Monitoramento de Medicamentos , Detecção Precoce de Câncer
3.
Micromachines (Basel) ; 12(5)2021 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-33922553

RESUMO

We propose an integrated serial dilution generator utilizing centrifugal force with a degassed polydimethylsiloxane (PDMS) microfluidic device. Using gas-soluble PDMS as a centrifugal microfluidic device material, the sample can be dragged in any arbitrary direction using vacuum-driven force, as opposed to in a single direction, without adding further actuation components. The vacuum-driven force allows the device to avoid the formation of air bubbles and exhibit high tolerance in the surface condition. The device was then used for sample metering and sample transferring. In addition, centrifugal force was used for sample loading and sample mixing. In this study, a series of ten-fold serial dilutions ranging from 100 to 10-4 with about 8 µL in each chamber was achieved, while the serial dilution ratio and chamber volume could easily be altered by changing the geometrical designs of the device. As a proof of concept of our hybrid approach with the centrifugal and vacuum-driven forces, ten-fold serial dilutions of a cDNA (complementary DNA) sample were prepared using the device. Then, the diluted samples were collected by fine needles and subject to a quantitative polymerase chain reaction (qPCR), and the results were found to be in good agreement with those for samples prepared by manual pipetting.

4.
Biomicrofluidics ; 14(3): 031503, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32509049

RESUMO

Suitable micropumping methods for flow control represent a major technical hurdle in the development of microfluidic systems for point-of-care testing (POCT). Passive micropumping for point-of-care microfluidic systems provides a promising solution to such challenges, in particular, passive micropumping based on capillary force and air transfer based on the air solubility and air permeability of specific materials. There have been numerous developments and applications of micropumping techniques that are relevant to the use in POCT. Compared with active pumping methods such as syringe pumps or pressure pumps, where the flow rate can be well-tuned independent of the design of the microfluidic devices or the property of the liquids, most passive micropumping methods still suffer flow-control problems. For example, the flow rate may be set once the device has been made, and the properties of liquids may affect the flow rate. However, the advantages of passive micropumping, which include simplicity, ease of use, and low cost, make it the best choice for POCT. Here, we present a systematic review of different types of passive micropumping that are suitable for POCT, alongside existing applications based on passive micropumping. Future trends in passive micropumping are also discussed.

5.
Micromachines (Basel) ; 11(4)2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32244684

RESUMO

Microfluidic devices and systems are well-suited for the manipulation of biomolecules, cells, or particles [...].

6.
IEEE Trans Biomed Eng ; 67(5): 1321-1327, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31425013

RESUMO

OBJECTIVE: We present a new photoacoustic tomography system that provides visualization of angiographic features in a human breast with mammogram-like images. METHODS: The system images a mildly compressed breast, from both top and bottom, using two 128-element, 2.25 MHz linear transducer arrays and line optical fiber bundles. The mild compression is achieved using plastic films, which is a more comfortable experience for the patient compared to rigid metal plates used in a traditional mammogram. RESULTS: We could image a D cup-sized breast of 7 cm thickness within 1 minute and achieve a spatial resolution of around 1 mm in all directions. CONCLUSION: Our system possesses the benefits of portability, speedy scanning, and patient comfort. The craniocaudal-view images can be easily correlated with existing imaging modalities for data interpretation. SIGNIFICANCE: Early cancer detection plays a critical role in overall cancer survival rate. Our system may address the limitations of mammogram and offer a radiation-free screening technique for patients with dense breasts.


Assuntos
Neoplasias da Mama , Técnicas Fotoacústicas , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Mamografia , Tomografia Computadorizada por Raios X , Transdutores
7.
Micromachines (Basel) ; 10(8)2019 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-31426526

RESUMO

In this paper, a simple syringe­assisted pumping method is introduced. The proposed fluidic micropumping system can be used instead of a conventional pumping system which tends to be large, bulky, and expensive. The micropump was designed separately from the microfluidic channels and directly bonded to the outlet of the microfluidic device. The pump components were composed of a dead­end channel which was surrounded by a microchamber. A syringe was then connected to the pump structure by a short tube, and the syringe plunger was manually pulled out to generate low pressure inside the microchamber. Once the sample was loaded in the inlet, air inside the channel diffused into the microchamber through the PDMS (polydimethylsiloxane) wall, acting as a dragging force and pulling the sample toward the outlet. A constant flow with a rate that ranged from 0.8 nl · s - 1 to 7.5 nl · s - 1 was achieved as a function of the geometry of the pump, i.e., the PDMS wall thickness and the diffusion area. As a proof-of-concept, microfluidic mixing was demonstrated without backflow. This method enables pumping for point-of-care testing (POCT) with greater flexibility in hand-held PDMS microfluidic devices.

8.
Micromachines (Basel) ; 9(10)2018 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-30424422

RESUMO

In this paper, we presented a straightforward strategy to generate 15 combinations of three samples based on an experimental simplex lattice design using a single-layer microfluidic network. First, we investigated the performances of the plain structural and the groove structural combinatorial devices by computational simulation (CFD-ACE+). The simulated output concentrations were extremely close to the desirable values within an absolute error of less than 1%. Based on the simulated designs, polydimethylsiloxane (PDMS) devices were fabricated with soft lithography and tested with fluorescent dye (sodium salt). The mixing results for 15 combinations showed good performance, with an absolute error of less than 4%. We also investigated two liquid handling methods (bottom⁻up and top⁻down) for high-throughput screening and assay. The liquid-handling methods were successfully accomplished by adding the systematic structured groove sets on the mixing channels.

9.
Sci Rep ; 8(1): 13004, 2018 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-30158556

RESUMO

Although linear transducer arrays have been intensely used in photoacoustic imaging, their geometrical shape constrains light illumination. Today, most linear array based photoacoustic systems utilize side-illumination geometry, which consists of two line fiber bundles attached to the side of the probe. The angled light illumination increases the light travel distance in deep tissue, consequently limiting the imaging depth. This issue was partially addressed by adding a right angle prism in front of the transducer. While this design makes the light illumination and acoustic detection co-axial, the transducer and the fiber bundles are orthogonal to each other, making the system inconvenient for handheld use. To overcome this limitation, here we propose a double-reflector design, in which the second reflector redirects the acoustic signals by another 90°, so that the transducer and the fiber bundle are now parallel to each other. In this design, both the transducer and fiber bundle output are fitted into a compact housing for convenient handheld imaging. To evaluate the efficiency of our design, we performed various phantom and human in vivo experiments. Our results demonstrate that the double-reflector design indeed provides deeper imaging depth and it also allows for easy imaging of objects with uneven surfaces.

10.
Biomicrofluidics ; 12(3): 034111, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29937951

RESUMO

This paper presents a novel manipulation method for micro-objects using acoustically oscillating bubbles with a controllable position based on the gas permeability of polydimethylsiloxane. The oscillating bubble trapped within the side channel attracts the neighboring micro-objects, and the position of the air-liquid interface is controlled by generating temporary pressure difference between the side channel and the air channel. To demonstrate the feasibility of the method in technological applications, polystyrene microparticles of 10 µm in diameter were successfully captured, transported, and released. The influence of pressure difference on the movement speed of the air-liquid interface was demonstrated in our experiments, and the manipulation performance was also characterized by varying the frequency of the acoustic excitation and the pressure difference. Since the bubble generation and the air-liquid interface movement in our manipulation method do not need any electrochemical reaction and any high temperature, this on-chip manipulation method provides a controllable, efficient, and noninvasive tool for handling micro-objects such as particles, cells, and other entities. The whole manipulation process, including capturing, transporting, and releasing of particles, spent less than 1 min. It can be used to select the cells and particles in the microfluidic device or change the cell culture medium.

11.
Lab Chip ; 18(2): 276-284, 2018 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-29199733

RESUMO

In capillary- or vacuum-driven microfluidics, surge backflow events are common when merging or pumping two similar or dissimilar liquids together if a pressure difference exists between them. In this work, a robust, portable micromixing device that is insensitive to backflow was designed, fabricated and characterised. A capillary-driven pressure balancing bypass connected between two inlet ports diminished the initial pressure difference caused by capillarity and gravity present in each liquid at the two inlet ports. Then, using manual syringe-assisted vacuum-driven pumping that operated based on the high gas permeability of polydimethylsiloxane, the two pre-balanced liquid streams could synchronously enter a dead-end micromixing channel without any backflow. To test the performance of this device, we first used it to mix two aqueous solutions of different coloured dyes. We varied the initial volume difference between the solutions to study the effect of gravity-induced pressure difference on mixing. Next, as a proof-of-concept application, ABO/Rh blood groups were successfully determined through detection of blood antigen-antibody agglutination. The filling time of agglutinated samples, driven by the simple syringe-assisted pumping, in the dead-end mixing channel was consistently 10% longer than that of blood samples without the agglutination reaction. Thus, the proposed device shows great potential for use in a wide variety of blood typing assays, agglutination-based assays and point-of-care or lab-on-a-chip testing applications.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Tipagem e Reações Cruzadas Sanguíneas/instrumentação , Tipagem e Reações Cruzadas Sanguíneas/métodos , Desenho de Equipamento , Humanos , Vácuo
12.
Micromachines (Basel) ; 8(9)2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-30400470

RESUMO

Polydimethylsiloxane (PDMS) is a flexible and biocompatible material widely used in the fabrication of microfluidic devices, and is often studied for the fabrication of flexible electrodes. The most popular method of fabricating a flexible electrode using PDMS is done by transferring a metal electrode onto said PDMS. However, the transfer process is difficult and the transferred metal layer is easily damaged due to inherently weak adhesion forces between the metal and PDMS, thus requiring a chemical treatment or sacrificial layer between the two. The fabrication process using a chemical treatment or sacrificial layer is complicated and expensive, which is the major limitation of using PDMS in the fabrication of flexible electrodes. This paper discusses the findings of a possible solution to create strong bonding between PDMS and various metals (copper, nickel and silver) using a chemical-free metal to PDMS thermal bonding technique. This method is the same as the PDMS curing process, but with a variation in the curing condition. The condition required to create strong bonding was studied by observing copper transferred by various PDMS curing conditions, including the standard condition. The condition creating the strong bonding was baking PDMS (5:1 = base polymer: curing agent) at 150 °C for 20 min. Experimentation showed that the optimum thickness of the transferred metal shows that the optimum thickness is approximately 500 nm, which allows for a higher resistance to stresses. The successful transfer of copper, nickel and silver layers onto PDMS with a stronger adhesion force opens up many new applications dealing with the fabrication of flexible electrodes, sensors, and flexible soft magnets.

13.
Micromachines (Basel) ; 8(12)2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-30400533

RESUMO

Life scientists are closely working with engineers to solve biological and biomedical problems through the application of engineering tools.[...].

14.
Micromachines (Basel) ; 7(10)2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30404347

RESUMO

We report a simple method to fabricate PDMS (polydimethylsiloxane) microwell arrays on glass by using a PDMS stamp to study cell-to-cell adhesion. In the cell-to-cell study, a glass substrate is required since glass has better cell attachment. The microwell arrays are replicated from an SU-8 master mold, and then are transferred to a glass substrate by lifting the PDMS stamp, followed by oxygen plasma bonding of the PDMS stamp on the glass substrate. For the cell-to-cell adhesion, four different types of PDMS arrays (e.g., rectangle, bowtie, wide-rhombus, and rhombus) were designed to vary the cell-to-cell contact length. The transfer success rates of the microwell arrays were measured as a function of both the contact area of the PDMS and the glass substrate and the different ratios between the base polymers and the curing agent. This method of generating the microwell arrays will enable a simple and robust construction of PDMS-based devices for various biological applications.

15.
Lab Chip ; 15(20): 3962-79, 2015 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-26329518

RESUMO

Suitable pumping methods for flow control remain a major technical hurdle in the path of biomedical microfluidic systems for point-of-care (POC) diagnostics. A vacuum-driven power-free micropumping method provides a promising solution to such a challenge. In this review, we focus on vacuum-driven power-free microfluidics based on the gas solubility or permeability of polydimethylsiloxane (PDMS); degassed PDMS can restore air inside itself due to its high gas solubility or gas permeable nature. PDMS allows the transfer of air into a vacuum through it due to its high gas permeability. Therefore, it is possible to store or transfer air into or through the gas soluble or permeable PDMS in order to withdraw liquids into the embedded dead-end microfluidic channels. This article provides a comprehensive look at the physics of the gas solubility and permeability of PDMS, a systematic review of different types of vacuum-driven power-free microfluidics, and guidelines for designing solubility-based or permeability-based PDMS devices, alongside existing applications. Advanced topics and the outlook in using micropumping that utilizes the gas solubility or permeability of PDMS will be also discussed. We strongly recommend that microfluidics and lab-on-chip (LOC) communities harness vacuum energy to develop smart vacuum-driven microfluidic systems.

16.
Biomicrofluidics ; 9(1): 014106, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25713688

RESUMO

We propose a blood separation microfluidic device suitable for point-of-care (POC) applications. By utilizing the high gas permeability of polydimethylsiloxane (PDMS) and phaseguide structures, a simple blood separation device is presented. The device consists of two main parts. A separation chamber with the phaseguide structures, where a sample inlet, a tape-sealed outlet, and a dead-end ring channel are connected, and pneumatic chambers, in which manually operating syringes are plugged. The separation chamber and pneumatic chambers are isolated by a thin PDMS wall. By manually pulling out the plunger of the syringe, a negative pressure is instantaneously generated inside the pneumatic chamber. Due to the gas diffusion from the separation chamber to the neighboring pneumatic chamber through the thin permeable PDMS wall, low pressure can be generated, and then the whole blood at the sample inlets starts to be drawn into the separation chamber and separated through the phaseguide structures. Reversely, after removing the tape at the outlet and manually pushing in the plunger of the syringe, a positive pressure will be created which will cause the air to diffuse back into the ring channel, and therefore allow the separated plasma to be recovered at the outlet on demand. In this paper, we focused on the study of the plasma separation and associated design parameters, such as the PDMS wall thickness, the air permeable overlap area between the separation and pneumatic chambers, and the geometry of the phaseguides. The device required only 2 µl of whole blood but yielding approximately 0.38 µl of separated plasma within 12 min. Without any of the requirements of sophisticated equipment or dilution techniques, we can not only separate the plasma from the whole blood for on-chip analysis but also can push out only the separated plasma to the outlet for off-chip analysis.

17.
J Am Soc Cytopathol ; 4(3): 141-147, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-31051695

RESUMO

INTRODUCTION: The advent of precision medicine will increase the demand for molecular testing on patient tumor specimens. Cytology specimens have been shown to be ideal substrates for molecular testing, but their often paucicellular nature can lead to conflicts in prioritizing sample management. A microfluidic platform was investigated to determine whether cytologic and molecular data could be procured from the same cells, obviating the need for partitioning a sample by multiplexing it instead. MATERIALS AND METHODS: Cytology samples were created from a tissue source, stained with a supravital dye, and enriched using immunomagnetic beads. These cells and the attached immunomagnetic beads were then run through a microfluidic channel, temporarily immobilized for cytologic examination, and then recovered. The cytologic characteristics of these cells was compared with cells from the same source prepared by conventional cytologic preparatory means. DNA was extracted from the cells recovered from the microfluidic channel and the nature of their integrity was assessed. RESULTS: Cytologic features between cells run in a microfluidic channel and prepared by conventional means were similar. The DNA recovered from the cells run through the microfluidic channel was of high molecular weight. CONCLUSIONS: Microfluidics enables multiplex testing of cytologic specimens, allowing for cytology-based diagnostic examination and recovery of high-quality DNA. This approach will be of particular benefit for cytology specimens that are paucicellular and will need molecular testing.

18.
Biomicrofluidics ; 8(4): 044113, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25379098

RESUMO

In this paper, we propose a continuous flow droplet-based microfluidic platform for magnetic particle-based assays by employing in-droplet washing. The droplet-based washing was implemented by traversing functionalized magnetic particles across a laterally merged droplet from one side (containing sample and reagent) to the other (containing buffer) by an external magnetic field. Consequently, the magnetic particles were extracted to a parallel-synchronized train of washing buffer droplets, and unbound reagents were left in an original train of sample droplets. To realize the droplet-based washing function, the following four procedures were sequentially carried in a droplet-based microfluidic device: parallel synchronization of two trains of droplets by using a ladder-like channel network; lateral electrocoalescence by an electric field; magnetic particle manipulation by a magnetic field; and asymmetrical splitting of merged droplets. For the stable droplet synchronization and electrocoalescence, we optimized droplet generation conditions by varying the flow rate ratio (or droplet size). Image analysis was carried out to determine the fluorescent intensity of reagents before and after the washing step. As a result, the unbound reagents in sample droplets were significantly removed by more than a factor of 25 in the single washing step, while the magnetic particles were successfully extracted into washing buffer droplets. As a proof-of-principle, we demonstrate a magnetic particle-based immunoassay with streptavidin-coated magnetic particles and fluorescently labelled biotin in the proposed continuous flow droplet-based microfluidic platform.

19.
Sensors (Basel) ; 14(9): 17008-36, 2014 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-25222033

RESUMO

In this paper, we review recent advances in on-chip sensors integrated with microfluidics for biological applications. Since the 1990s, much research has concentrated on developing a sensing system using optical phenomena such as surface plasmon resonance (SPR) and surface-enhanced Raman scattering (SERS) to improve the sensitivity of the device. The sensing performance can be significantly enhanced with the use of microfluidic chips to provide effective liquid manipulation and greater flexibility. We describe an optical image sensor with a simpler platform for better performance over a larger field of view (FOV) and greater depth of field (DOF). As a new trend, we review consumer electronics such as smart phones, tablets, Google glasses, etc. which are being incorporated in point-of-care (POC) testing systems. In addition, we discuss in detail the current optical sensing system integrated with a microfluidic chip.


Assuntos
Técnicas Biossensoriais/instrumentação , Computadores de Mão , Técnicas Analíticas Microfluídicas/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Análise Espectral Raman/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Transdutores
20.
Artigo em Inglês | MEDLINE | ID: mdl-25570074

RESUMO

In this paper, we propose a microfluidic platform toseparate magnetic particles with a constant volumetric flow condition. In order to realize this architecture, three main functions for a droplet manipulation based system are integrated into a single device: synchronization of droplets by matching a location of droplets; lateral electro-coalescence; and magnetic particle manipulation. For an optimized condition of this device, a droplet generation was controlled by varying a droplet size at a fixed flow rate ratio 0.86. The electro-coalescence efficiency and maximum throughput are investigated at a given flow rate condition.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Técnicas Eletroquímicas , Eletrodos , Magnetismo , Técnicas Analíticas Microfluídicas/instrumentação , Compostos de Estanho/química