Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Biomed Mater ; 19(4)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38740059

RESUMO

Cell-based tissue engineering often requires the use of scaffolds to provide a three-dimensional (3D) framework for cell proliferation and tissue formation. Polycaprolactone (PCL), a type of polymer, has good printability, favorable surface modifiability, adaptability, and biodegradability. However, its large-scale applicability is hindered by its hydrophobic nature, which affects biological properties. Composite materials can be created by adding bioactive materials to the polymer to improve the properties of PCL scaffolds. Osteolectin is an odontogenic factor that promotes the maintenance of the adult skeleton by promoting the differentiation of LepR+ cells into osteoblasts. Therefore, the aim of this study was to evaluate whether 3D-printed PCL/osteolectin scaffolds supply a suitable microenvironment for the odontogenic differentiation of human dental pulp cells (hDPCs). The hDPCs were cultured on 3D-printed PCL scaffolds with or without pores. Cell attachment and cell proliferation were evaluated using EZ-Cytox. The odontogenic differentiation of hDPCs was evaluated by alizarin red S staining and alkaline phosphatase assays. Western blot was used to evaluate the expression of the proteins DSPP and DMP-Results: The attachment of hDPCs to PCL scaffolds with pores was significantly higher than to PCL scaffolds without pores. The odontogenic differentiation of hDPCs was induced more in PCL/osteolectin scaffolds than in PCL scaffolds, but there was no statistically significant difference. 3D-printed PCL scaffolds with pores are suitable for the growth of hDPCs, and the PCL/osteolectin scaffolds can provide a more favorable microenvironment for the odontogenic differentiation of hDPCs.


Assuntos
Diferenciação Celular , Proliferação de Células , Polpa Dentária , Odontogênese , Poliésteres , Impressão Tridimensional , Engenharia Tecidual , Alicerces Teciduais , Humanos , Polpa Dentária/citologia , Poliésteres/química , Alicerces Teciduais/química , Diferenciação Celular/efeitos dos fármacos , Odontogênese/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Engenharia Tecidual/métodos , Células Cultivadas , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Adesão Celular/efeitos dos fármacos , Osteoblastos/citologia
2.
J. appl. oral sci ; 25(6): 680-688, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - odontologia (Brasil) | ID: biblio-893667

RESUMO

Abstract Objectives: Methylcellulose (MC) is a chemical compound derived from cellulose. MTA mixed with MC reduces setting time and increases plasticity. This study assessed the influence of MC as an anti-washout ingredient and CaCl2 as a setting time accelerator on the physical and biological properties of MTA. Material and Methods: Test materials were divided into 3 groups; Group 1(control): distilled water; Group 2: 1% MC/CaCl2; Group 3: 2% MC/CaCl2. Compressive strength, pH, flowability and cell viability were tested. The gene expression of bone sialoprotein (BSP) was detected by RT-PCR and real­ time PCR. The expression of alkaline phosphatase (ALP) and mineralization behavior were evaluated using an ALP staining and an alizarin red staining. Results: Compressive strength, pH, and cell viability of MTA mixed with MC/CaCl2 were not significantly different compared to the control group. The flowability of MTA with MC/CaCI2 has decreased significantly when compared to the control (p<.05). The mRNA level of BSP has increased significantly in MTA with MC/CaCl2 compared to the control (p<.05). This study revealed higher expression of ALP and mineralization in cells exposed to MTA mixed with water and MTA mixed with MC/CaCl2 compared to the control (p<.05). Conclusions: MC decreased the flowability of MTA and did not interrupt the physical and biological effect of MTA. It suggests that these cements may be useful as a root-end filling material.


Assuntos
Animais , Camundongos , Óxidos/farmacologia , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Cloreto de Cálcio/farmacologia , Silicatos/farmacologia , Silicatos/química , Compostos de Cálcio/farmacologia , Compostos de Cálcio/química , Compostos de Alumínio/farmacologia , Compostos de Alumínio/química , Metilcelulose/farmacologia , Teste de Materiais , Células Cultivadas/efeitos dos fármacos , Força Compressiva , Polpa Dentária/efeitos dos fármacos , Combinação de Medicamentos
3.
J. appl. oral sci ; 21(4): 293-299, Jul-Aug/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-684563

RESUMO

OBJECTIVE: The purpose of this study was to investigate the polymerization temperature of a bulk filled composite resin light-activated with various light curing modes using infrared thermography according to the curing depth and approximation to the cavity wall. MATERIAL AND METHODS: Composite resin (AeliteFlo, Bisco, Schaumburg, IL, USA) was inserted into a Class II cavity prepared in the Teflon blocks and was cured with a LED light curing unit (Dr's Light, GoodDoctors Co., Seoul, Korea) using various light curing modes for 20 s. Polymerization temperature was measured with an infrared thermographic camera (Thermovision 900 SW/TE, Agema Infra-red Systems AB, Danderyd, Sweden) for 40 s at measurement spots adjacent to the cavity wall and in the middle of the cavity from the surface to a 4 mm depth. Data were analyzed according to the light curing modes with one-way ANOVA, and according to curing depth and approximation to the cavity wall with two-way ANOVA. RESULTS: The peak polymerization temperature of the composite resin was not affected by the light curing modes. According to the curing depth, the peak polymerization temperature at the depth of 1 mm to 3 mm was significantly higher than that at the depth of 4 mm, and on the surface. The peak polymerization temperature of the spots in the middle of the cavity was higher than that measured in spots adjacent to the cavity wall. CONCLUSION: In the photopolymerization of the composite resin, the temperature was higher in the middle of the cavity compared to the outer surface or at the internal walls of the prepared cavity. .


Assuntos
Lâmpadas de Polimerização Dentária , Resinas Compostas/efeitos da radiação , Temperatura Alta , Cura Luminosa de Adesivos Dentários/métodos , Polimerização/efeitos da radiação , Análise de Variância , Resinas Compostas/química , Teste de Materiais , Propriedades de Superfície , Fatores de Tempo
4.
J. appl. oral sci ; 20(5): 576-580, Sept.-Oct. 2012. tab
Artigo em Inglês | LILACS | ID: lil-654924

RESUMO

OBJECTIVE: The aim of this study was to evaluate the effect of multiple layers of an infection control barrier on the micro-hardness of a composite resin. MATERIAL AND METHODS: One, two, four, and eight layers of an infection control barrier were used to cover the light guides of a high-power light emitting diode (LeD) light curing unit (LCU) and a low-power halogen LCU. The composite specimens were photopolymerized with the LCUs and the barriers, and the micro-hardness of the upper and lower surfaces was measured (n=10). The hardness ratio was calculated by dividing the bottom surface hardness of the experimental groups by the irradiated surface hardness of the control groups. The data was analyzed by two-way ANOVA and Tukey's HSD test. RESULTS: The micro-hardness of the composite specimens photopolymerized with the LED LCU decreased significantly in the four- and eight-layer groups of the upper surface and in the two-, four-, and eight-layer groups of the lower surface. The hardness ratio of the composite specimens was <80% in the eight-layer group. The micro-hardness of the composite specimens photopolymerized with the halogen LCU decreased significantly in the eight-layer group of the upper surface and in the two-, four-, and eight-layer groups of the lower surface. However, the hardness ratios of all the composite specimens photopolymerized with barriers were <80%. CONCLUSIONS: The two-layer infection control barrier could be used on high-power LCUs without decreasing the surface hardness of the composite resin. However, when using an infection control barrier on the low-power LCUs, attention should be paid so as not to sacrifice the polymerization efficiency.


Assuntos
Humanos , Lâmpadas de Polimerização Dentária , Resinas Compostas/química , Controle de Infecções Dentárias/métodos , Análise de Variância , Resinas Compostas/efeitos da radiação , Testes de Dureza , Teste de Materiais , Polimerização , Propriedades de Superfície , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA