Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Materials (Basel) ; 13(21)2020 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-33142941

RESUMO

This study evaluated the effectiveness of NiTi ultrasonic tips for Enterococcus faecalis (E. faecalis) biofilm removal in simulated complex root canals. Sixty root canal models consisting of a 30-degree curved main canal and two lateral canals were constructed from polydimethylsiloxane and incubated with E. faecalis. Irrigants in root canals were activated using a manual syringe (SI), a stainless steel (SS) instrument, a nickel-titanium (Ni-Ti) ultrasonic instrument, or a sonic instrument (EA). Instruments of SI, SS, and NiTi-9 groups were placed 9 mm from the apex, whereas those in NiTi-2 and EA groups were placed 2 mm from the apex. The efficacy of each method was determined as the ratio of fluorescence concentration before and after activation. In the apical curved canal, the highest efficacy was found in the NiTi-2 group (99.40%), followed by SI (84.25%), EA (80.38%), SS (76.93%), and NiTi-9 (67.29%) groups. In lateral canals 1 and 2, the efficacy was the highest in the NiTi-2 group and the lowest in the SI group. The NiTi ultrasonic instrument could effectively remove biofilms in the curved canal and lateral canals. This instrument should be introduced close to the working length. An up-and-down motion of the activation instrument is recommended.

3.
J Dent ; 86: 27-32, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31121242

RESUMO

OBJECTIVES: Conventional methods for detecting root fractures cannot assess their depth or bacterial contamination. This study was designed to measure the autofluorescence emitted from a root fracture, with the aim of determining whether this is a suitable method for quantifying the depth and bacterial invasion of a fracture. METHODS: This in vitro study investigated 33 mandibular second molars with periapical lesions that had been extracted after finding root fractures in endodontically treated teeth during intentional replantation or diagnostic surgery. The root fractures were scanned using a fluorescence technique, and the association between fluorescence parameters and fracture depth was analyzed. The significance of the association between the red fluorescence among autofluorescence parameters and bacterial contamination within the fracture was examined. RESULTS: When the depth of the root fractures was evaluated by micro computed tomography, the scattering of light in the fractures increased with depth, and there was a gradual increase in the quantitative fluorescence parameter indicating the deepest point (ΔFmax) in the fractures. In addition, we observed red fluorescence on the outer surface of deeper fractures. The tooth fractures exhibiting red fluorescence were evaluated for bacterial contamination associated with red-fluorescent porphyrin, which revealed bacterial invasion into these fractures. On the other hand, non-red-fluorescing fractures contained necrotic tissue, debris, and irritants. CONCLUSIONS: This viable fluorescent technique can potentially quantify the depth of root fractures and be used as a risk indicator for root fractures with periodontal inflammation. CLINICAL SIGNIFICANCE: The auto-fluorescence technique can be used to detect depth and bacterial contamination of root fractures. It is postulated that the auto-fluorescence can be used as a risk indicator of deep fractures and can replace conventional fracture detection methods.


Assuntos
Fraturas dos Dentes/microbiologia , Raiz Dentária/microbiologia , Dente não Vital , Humanos , Dente Molar , Microtomografia por Raio-X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA