Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Dosim ; 48(4): 261-266, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37455221

RESUMO

We modeled the Qfix Encompass™ immobilization system and further verified the calculated dose distribution of the AcurosXB (AXB) dose calculation algorithm using SRS MapCHECKⓇ (SRSMC) in the HyperArc™ (HA) clinical plan. An Encompass system with a StereoPHAN™ QA phantom was scanned by SOMATOM go.Sim and imported to an Eclipse™ treatment planning system to create a treatment plan for Encompass modeling. The Encompass modeling was performed in the StereoPHAN with a pinpoint ion chamber for 6 MV and 6 MV flattening filter free (6 MV FFF), and 2 × 2 cm2, 4 × 4 cm2, and 6 × 6 cm2 irradiation field sizes. The dose calculation algorithm used was AXB ver. 15.5 with a 1.0 mm calculation grid size. The Hounsfield unit (HU) values of the Encompass modeling were set to 400, -100, -200, and -300 for Encompass, and -400, -600, -700, and -800 for the Encompass base. We evaluated the dose distribution after Encompass modeling by SRSMC using gamma analysis in 12 patients. We adopted HU values of -200 for Encompass, -800 for Encompass base for 6 MV, and -200 for Encompass and -700 for Encompass. Base for 6 MV FFF was adopted as the HU values for the Encompass modeling based on the measurement results. The proposed Encompass modeling resulted in a mean pass rate evaluation >98% for both 6 MV and 6 MV FFF when the 1%/1 mm criterion was used, demonstrating that the proposed HU value can be adopted to calculate more accurate dose distributions.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Imagens de Fantasmas , Radioterapia de Intensidade Modulada/métodos
2.
Biologicals ; 30(4): 303-14, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12421588

RESUMO

We have established a manufacturing system for a Vero cell-derived inactivated Japanese encephalitis vaccine at a 500l scale. The production system involves expansion of Vero cells using microcarrier, followed by virus infection. Except for an additional purification step, the downstream purification processes are similar to those used for the current mouse brain-derived vaccine; cell removal, concentration and removal of low-molecular weight impurities by membrane filtration, formalin-inactivation, sucrose density gradient ultracentrifugation, and Sulfate-Cellulofine column chromatography are conducted. The antigen obtained from the manufacturing system was highly purified and its physico-chemical and immunological properties were comparable with those of antigen derived from mouse brains. Our system is very simple and could be easily scaled-up to allow vaccine production at a several thousand litre scale.


Assuntos
Vacinas contra Encefalite Japonesa/isolamento & purificação , Animais , Antígenos Virais/análise , Chlorocebus aethiops , Vírus da Encefalite Japonesa (Espécie)/imunologia , Vírus da Encefalite Japonesa (Espécie)/isolamento & purificação , Vírus da Encefalite Japonesa (Espécie)/ultraestrutura , Ensaio de Imunoadsorção Enzimática , Fermentação , Vacinas contra Encefalite Japonesa/imunologia , Camundongos , Microscopia Eletrônica , Testes de Neutralização , Segurança , Vacinas de Produtos Inativados/imunologia , Vacinas de Produtos Inativados/isolamento & purificação , Células Vero , Cultura de Vírus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA