1.
Cardiovasc Revasc Med ; 59: 93-98, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37723011

RESUMO

INTRODUCTION: Clinical events may occur after percutaneous coronary intervention (PCI), particularly in complex lesions and complex patients. The optimization of PCI result, using pressure guidewire and intracoronary imaging techniques, may reduce the risk of these events. The hypothesis of the present study is that the clinical outcome of patients with indication of PCI and coronary stent implantation that are at high risk of events can be improved with an unrestricted use of intracoronary tools that allow PCI optimization. METHODS AND ANALYSIS: Observational prospective multicenter international study, with a follow-up of 12 months, including 1064 patients treated with a cobalt­chromium everolimus-eluting stent. Inclusion criteria include any of the following: Lesion length > 28 mm; Reference vessel diameter < 2.5 mm or > 4.25 mm; Chronic total occlusion; Bifurcation with side branch ≥2.0 mm;Ostial lesion; Left main lesion; In-stent restenosis; >2 lesions stented in the same vessel; Treatment of >2 vessels; Acute myocardial infarction; Renal insufficiency; Left ventricular ejection fraction <30 %; Staged procedure. The control group will be comprised by a similar number of matched patients included in the "extended risk" cohort of the XIENCE V USA study. The primary endpoint will be the 1-year rate of target lesion failure (TLF) (composite of ischemia-driven TLR, myocardial infarction (MI) related to the target vessel, or cardiac death related to the target vessel). Secondary endpoints will include overall mortality, cardiovascular mortality, acute myocardial infarction, TVR, TLR, target vessel failure, and definitive or probable stent thrombosis at 1 year. IMPLICATIONS: The ongoing OPTI-XIENCE study will contribute to the growing evidence supporting the use of intra-coronary imaging techniques for stent optimization in patients with complex coronary lesions.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Sirolimo , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
2.
J Am Coll Cardiol ; 70(1): 42-55, 2017 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-28662806

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is standard therapy for patients with severe aortic stenosis who are at high surgical risk. However, national data regarding procedural characteristics and clinical outcomes over time are limited. OBJECTIVES: The aim of this study was to assess nationwide performance trends and clinical outcomes of TAVR during a 6-year period. METHODS: TAVRs performed in 48 centers across France between January 2013 and December 2015 were prospectively included in the FRANCE TAVI (French Transcatheter Aortic Valve Implantation) registry. Findings were further compared with those reported from the FRANCE 2 (French Aortic National CoreValve and Edwards 2) registry, which captured all TAVRs performed from January 2010 to January 2012 across 34 centers. RESULTS: A total of 12,804 patients from FRANCE TAVI and 4,165 patients from FRANCE 2 were included in this analysis. The median age of patients was 84.6 years, and 49.7% were men. FRANCE TAVI participants were older but at lower surgical risk (median logistic European System for Cardiac Operative Risk Evaluation [EuroSCORE]: 15.0% vs. 18.4%; p < 0.001). More than 80% of patients in FRANCE TAVI underwent transfemoral TAVR. Transesophageal echocardiography guidance decreased from 60.7% to 32.3% of cases, whereas more recent procedures were increasingly performed in hybrid operating rooms (15.8% vs. 35.7%). Rates of Valve Academic Research Consortium-defined device success increased from 95.3% in FRANCE 2 to 96.8% in FRANCE TAVI (p < 0.001). In-hospital and 30-day mortality rates were 4.4% and 5.4%, respectively, in FRANCE TAVI compared with 8.2% and 10.1%, respectively, in FRANCE 2 (p < 0.001 for both). Stroke and potentially life-threatening complications, such as annulus rupture or aortic dissection, remained stable over time, whereas rates of cardiac tamponade and pacemaker implantation significantly increased. CONCLUSIONS: The FRANCE TAVI registry provided reassuring data regarding trends in TAVR performance in an all-comers population on a national scale. Nonetheless, given that TAVR indications are likely to expand to patients at lower surgical risk, concerns remain regarding potentially life-threatening complications and pacemaker implantation. (Registry of Aortic Valve Bioprostheses Established by Catheter [FRANCE TAVI]; NCT01777828).


Assuntos
Estenose da Valva Aórtica/cirurgia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/tendências , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/epidemiologia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , França/epidemiologia , Humanos , Incidência , Masculino , Prognóstico , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo