Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pulm Med ; 22(1): 350, 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36114516

RESUMO

BACKGROUND: High flow nasal cannula (HFNC) is increasingly being used to support patients with acute respiratory failure (ARF) and to avoid need for intubation. However, almost one third of the patients do not respond and require escalation of respiratory support. Previously, ROX index (SpO2/FIO2 [SF] ratio/respiratory rate) has been validated among pneumonia patients to facilitate early recognition of patients likely to fail HFNC and therefore, benefit from timely interventions. However, it has been postulated that incorporation of PaO2/FIO2 (PF) ratio from arterial blood gas (ABG) analysis may better predict the outcome of HFNC compared to indices that utilizes SF ratio. Similarly, heart rate increase after HFNC therapy initiation has been found to be associated with HFNC failure. Therefore, we aimed to compare ROX index with a new modified index to predict HFNC outcomes among ARF patients. MATERIALS AND METHODS: This single centre 2-year retrospective study included ARF patients of varying etiologies treated with HFNC. The modified index incorporated heart rate and substituted PF ratio for SF ratio in addition to respiratory rate. We named the index POX-HR and calculated Delta POX-HR index as the difference pre- and post-HFNC initiation POX-HR. We also recorded ROX index at the time when post-HFNC initiation ABG was done ('post-HFNC initiation ROX') and calculated Delta ROX. HFNC success was defined as no need of escalation of respiratory support or discharged to ward within 48 h of HFNC initiation, or successful wean off HFNC for at least 12 h. Evaluation was performed using area under the receiver operating characteristic curve (AUROC) and cut-offs assessed for prediction of HFNC outcomes. RESULTS: One hundred eleven patients were initiated on HFNC for ARF, of whom 72 patients (64.9%) had HFNC success. Patients with HFNC failure had significantly lower values for all the indices. At median of 3.33 h (IQR 1.48-7.24 h), Delta POX-HR demonstrated the best prediction accuracy (AUROC 0.813, 95% CI 0.726-0.900). A Delta POX-HR > 0.1 was significantly associated with a lower risk of HFNC failure. CONCLUSIONS: Our proposed modified dynamic index (Delta POX-HR) may facilitate early and accurate prediction of HFNC outcomes compared to ROX index among ARF patients of varied etiologies.


Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Cânula/efeitos adversos , Frequência Cardíaca , Humanos , Oxigenoterapia/efeitos adversos , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Taxa Respiratória , Estudos Retrospectivos
2.
Ann Acad Med Singap ; 50(6): 467-473, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34195753

RESUMO

INTRODUCTION: Despite adhering to criteria for extubation, up to 20% of intensive care patients require re-intubation, even with use of post-extubation high-flow nasal cannula (HFNC). This study aims to identify independent predictors and outcomes of extubation failure in patients who failed post-extubation HFNC. METHODS: We conducted a multicentre observational study involving 9 adult intensive care units (ICUs) across 5 public hospitals in Singapore. We included patients extubated to HFNC following spontaneous breathing trials. We compared patients who were successfully weaned off HFNC with those who failed HFNC (defined as re-intubation ≤7 days following extubation). Generalised additive logistic regression analysis was used to identify independent risk factors for failed HFNC. RESULTS: Among 244 patients (mean age: 63.92±15.51 years, 65.2% male, median APACHE II score 23.55±7.35), 41 (16.8%) failed HFNC; hypoxia, hypercapnia and excessive secretions were primary reasons. Stroke was an independent predictor of HFNC failure (odds ratio 2.48, 95% confidence interval 1.83-3.37). Failed HFNC, as compared to successful HFNC, was associated with increased median ICU length of stay (14 versus 7 days, P<0.001), ICU mortality (14.6% versus 2.0%, P<0.001) and hospital mortality (29.3% versus 12.3%, P=0.006). CONCLUSION: Post-extubation HFNC failure, especially in patients with stroke as a comorbidity, remains a clinical challenge and predicts poorer clinical outcomes. Our observational study highlights the need for future prospective trials to better identify patients at high risk of post-extubation HFNC failure.


Assuntos
Extubação , Insuficiência Respiratória , Adulto , Cânula , Cuidados Críticos , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Insuficiência Respiratória/epidemiologia , Insuficiência Respiratória/terapia , Singapura/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA