Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
J Clin Pharm Ther ; 38(1): 68-70, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22725831

RESUMO

WHAT IS KNOWN AND OBJECTIVE: Levetiracetam is an anticonvulsant agent that was first approved for use in the United States in 1999 and has a maximum recommended adult dose of 3000 mg daily. It has been noted to have a relatively mild adverse effect profile, with the most common side effects being somnolence, asthenia, infection, and dizziness. Although it has been widely prescribed, there have been few reports on the safety of this agent in overdose. CASE SUMMARY: We present the case of a 49-year-old man who ingested over 22 500 mg of levetiracetam in a suicide attempt. The patient arrived at the Emergency Department 6·5 h after the ingestion and was noted to have no significant sequelae from the ingestion. Based on the patient's weight, he ingested 358 mg/kg of levetiracetam. WHAT IS NEW AND CONCLUSION: The few cases of levetiracetam overdose reported in the literature were associated with relatively mild, if any, symptoms. However, one patient who overdosed on levetiracetam became obtunded and developed significant respiratory distress that required intubation and ventilatory support. Therefore, clinical vigilance is still required in the cases of levetiracetam overdose.


Assuntos
Anticonvulsivantes/intoxicação , Overdose de Drogas , Piracetam/análogos & derivados , Humanos , Levetiracetam , Masculino , Pessoa de Meia-Idade , Piracetam/intoxicação , Tentativa de Suicídio
4.
Angiology ; 48(5): 463-7, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9158391

RESUMO

Four pregnant women with mitral stenosis who did not respond to medical therapy underwent successful percutaneous balloon valvuloplasty with complete resolution of their symptoms. Their clinical features and echocardial and hemodynamic data are presented. The procedures and the remainder of their pregnancy were uncomplicated. Percutaneous balloon valvuloplasty of the mitral valve is a safe and effective alternative to surgical therapy if medical management is unsuccessful.


Assuntos
Cateterismo , Estenose da Valva Mitral/terapia , Complicações Cardiovasculares na Gravidez/terapia , Adulto , Feminino , Humanos , Gravidez , Resultado do Tratamento
5.
Echocardiography ; 12(1): 29-34, 1995 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10150388

RESUMO

Fifteen patients with constrictive pericarditis were prospectively evaluated with echocardiography and Doppler recordings during respiratory monitoring. Eleven who agreed to surgery also underwent right heart catheterization and a repeat echocardiography with Doppler 10 days after pericardiectomy. Preoperatively, there was a significant inspiratory decrease in the mitral E wave (P < 0.05) and increase in the tricuspid E wave velocities (P < 0.05), which both normalized after pericardiectomy. The mitral deceleration times increased from 110 +/- 40 to 149 +/- 46 msec (P < 0.05) postoperatively. The preoperative hepatic vein velocities showed an accentuated systolic flow pattern. The systolic to diastolic ratio of the hepatic vein velocities was higher in patients who improved with surgery (1.42 +/- 0.31 vs 0.65 +/- 0.13) (P < 0.05). Postoperatively the diastolic flow became more pronounced. There was a 100% expiratory diastolic flow reversal in eight patients preoperatively, which normalized after pericardiectomy. Clinically these patients improved significantly postoperatively. Left atrial size, ejection fraction, and mitral and tricuspid filling velocities during respiratory monitoring could not predict surgical outcome. Pericardiectomy improved Doppler filling dynamics in all patients although this was not parallel to clinical improvement.


Assuntos
Ecocardiografia Doppler , Ecocardiografia , Pericardiectomia , Pericardite Constritiva/diagnóstico por imagem , Adulto , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pericardite Constritiva/epidemiologia , Pericardite Constritiva/cirurgia , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
6.
ASAIO J ; 40(3): M619-24, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-8555589

RESUMO

Copolymers composed of polar and nonpolar blocks, when blended with a base polymer in low concentrations, migrate to the base polymer surface during and after fabrication. Migration of these surface modifying additives (SMAs) dramatically changes the outermost surface molecular layers that comprise the region that determines biocompatibility. The blood compatibility of cardiopulmonary bypass and hemodialysis components have been improved by using SMA blended polymers or SMA coated surfaces. The particular SMAs used were a series of triblock copolymers with a general formulation of polycaprolactone-polydimethylsiloxane-polycaprolactone. X-ray fluorescence (XRF), fourier transform infrared (FTIR), refractive increments (RI), and gel permeation chromatography (GPC) were used to characterize the molecular weight of SMA and the bulk concentration of SMA after blending. Electron spectroscopy for chemical analysis (ESCA) proved that the surface of blended polymers was highly saturated with SMA. Results of in vitro experiments with human blood demonstrated that SMA blended polymers delay contact activation (kallikrein-like activity), reduce coagulation activity (thrombin-antithrombin [TAT] generation), and do not adversely affect complement activation (terminal complement complex [TCC] generation) or mononuclear cells activation (IL-1 beta production). Ex vivo canine AV shunt studies showed improvement of platelet compatibility of SMA blended polymers. Reduction of cellular and protein system activation by using components fabricated with SMA blood contacting surfaces can potentially result in reduced morbidity associated with extracorporeal circulation.


Assuntos
Materiais Biocompatíveis , Sangue , Circulação Extracorpórea , Animais , Materiais Biocompatíveis/química , Coagulação Sanguínea , Fenômenos Químicos , Físico-Química , Ativação do Complemento , Dimetilpolisiloxanos/química , Cães , Circulação Extracorpórea/efeitos adversos , Circulação Extracorpórea/métodos , Humanos , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Poliésteres/química , Silicones/química , Propriedades de Superfície
7.
Jpn Heart J ; 34(1): 117-9, 1993 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8515569

RESUMO

A patient was found to have a mobile catheter fragment in the right atrium incidentally during echocardiography. On further investigation, it was learned that the catheter had been inserted 9 years earlier during surgery and had probably been broken during removal. The patient did not experience any symptoms during this period. The catheter was removed percutaneously without any complications using a system similar to the loopsnare catheter.


Assuntos
Cateterismo Venoso Central/instrumentação , Corpos Estranhos/terapia , Átrios do Coração , Ecocardiografia , Corpos Estranhos/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
8.
Eur J Cardiothorac Surg ; 6(3): 161-3, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1567632

RESUMO

A hydatid cyst of the heart is rare. Surgical treatment is the preferable method in the treatment of cardiac echinococcosis. A 27-year-old patient with right ventricular hydatid cyst causing recurrent pulmonary emboli and diagnosed by 2-dimensional echocardiography and treated surgically is presented.


Assuntos
Cardiomiopatias/complicações , Equinococose/complicações , Embolia Pulmonar/etiologia , Adulto , Cardiomiopatias/diagnóstico , Equinococose/diagnóstico , Ecocardiografia , Feminino , Humanos , Recidiva
9.
Nuklearmedizin ; 30(5): 183-8, 1991 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1800943

RESUMO

Left ventricular function including regional wall motion (RWM) was evaluated by 99mTc first-pass and equilibrium gated blood pool ventriculography and glycohemoglobin (HbA1c) blood levels determined by a quantitative column technique in 25 young patients with insulin-dependent diabetes mellitus without clinical evidence of heart disease, and in healthy controls matched for age and sex. Phase analysis revealed abnormal RWM in 19 of 21 diabetic patients. The mean left ventricular global ejection fraction, the mean regional ejection fraction and the mean 1/3 filling fraction were lower and the time to peak ejection, the time to peak filling and the time to peak ejection/cardiac cycle were longer in diabetics than in controls. We found high HbA1c levels in all diabetics. There was no significant difference between patients with and without retinopathy and with and without peripheral neuropathy in terms of left ventricular function and HbA1c levels.


Assuntos
Diabetes Mellitus Tipo 1/fisiopatologia , Hemoglobinas Glicadas/metabolismo , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Criança , Diabetes Mellitus Tipo 1/sangue , Retinopatia Diabética/fisiopatologia , Feminino , Imagem do Acúmulo Cardíaco de Comporta , Humanos , Masculino , Contração Miocárdica/fisiologia
10.
Int J Cardiol ; 31(2): 199-204, 1991 May.
Artigo em Inglês | MEDLINE | ID: mdl-1869329

RESUMO

Because previous studies have shown that mast cells can be activated by IgE-mediated mechanisms to release potent mediators which affect coronary blood flow, we measured serum IgE levels in 156 patients with coronary arterial disease and in 53 healthy controls (27 men, 26 women, mean 54 years). Patients were classified into 3 groups according to well established criteria as having stable angina pectoris (28 men, 15 women, mean 58 years), unstable angina pectoris (37 men, 15 women, mean 57 years), and acute myocardial infarction (52 men, 9 women, mean 58 years). In every subject, serum IgE measurement, eosinophil count, and stool examination for parasites were performed. Every subject was interviewed concerning history of allergy, smoking habits and the other risk factors for coronary arterial disease. In a model including the factors that may affect the serum levels of IgE (namely, age, sex, cigarette smoking, parasites, and family and personal history of allergy), IgE levels were found to be significantly higher in the patients with unstable angina and acute myocardial infarction compared to the patients with stable angina pectoris and controls. These data indicate that IgE may play a role in the pathogenesis of unstable angina pectoris and acute myocardial infarction.


Assuntos
Doença das Coronárias/sangue , Imunoglobulina E/análise , Adulto , Idoso , Angina Pectoris/sangue , Angina Instável/sangue , Eosinófilos , Feminino , Humanos , Contagem de Leucócitos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/sangue , Fatores de Risco
11.
Pacing Clin Electrophysiol ; 14(5 Pt 1): 800-6, 1991 May.
Artigo em Inglês | MEDLINE | ID: mdl-1712957

RESUMO

Eleven patients with rate responsive pacemakers (7 men, 4 women, mean age 41 years with a range of 23-60) were randomly assigned to a cross-over study in order to assess their overall exercise capacity and quality-of-life (QOL) scores. All of the pacemakers were implanted for complete AV block or sick sinus syndrome. The pacemakers were randomly programmed into VVI or rate responsive (VVIR) pacing modes for 3-week study periods in each mode. At the end of each period, an exercise test was performed and the QOL was evaluated by the "Hacettepe Quality-of-Life Questionnaire". All patients exercised longer in the VVIR mode (mean 10.54 +/- 0.73 min) than in the VVI mode (mean 7.81 +/- 0.62 min) (P less than 0.05). QOL scores were also found to be significantly higher in the VVIR mode (mean 173.81 +/- 16.22 points) compared to the VVI mode (mean 156.27 +/- 21.22 points) (P less than 0.01). In conclusion, our results suggest that VVIR pacing offers a better QOL in addition to an improved exercise capacity, compared to the single chamber nonrate modulated pacing (VVI).


Assuntos
Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Qualidade de Vida , Adulto , Atitude Frente a Saúde , Feminino , Bloqueio Cardíaco/terapia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Resistência Física/fisiologia , Esforço Físico/fisiologia , Síndrome do Nó Sinusal/terapia , Fatores de Tempo
12.
Eur J Cardiothorac Surg ; 5(7): 388-90, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1892670

RESUMO

Familial and biatrial myxomas of the heart have rarely been described. We describe a familial atrial myxoma involving a parent with biatrial and a child with a left atrial myxoma. Atrial myxomas were diagnosed preoperatively by echocardiography and successfully removed at operation. Echocardiography can be used in the diagnosis of cardiac myxoma, detection of its possible recurrence and for screening other members of the family.


Assuntos
Neoplasias Cardíacas/genética , Mixoma/genética , Adolescente , Ecocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Neoplasias Cardíacas/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Mixoma/diagnóstico por imagem
15.
Jpn J Pharmacol ; 52(2): 189-93, 1990 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2179605

RESUMO

Hypertensive crises require immediate therapy, usually by parenteral drug administration. Sublingual nifedipine has been shown to be highly effective. However, the blood pressure fall following nifedipine is frequently associated with side-effects. The use of sublingual captopril has recently been indicated in hypertensive crisis, assuming that by this route, there would be a faster absorption and thus a more rapid effect on blood pressure than with the oral route. To verify this hypothesis, we have compared the hypotensive effects of sublingual nifedipine and sublingual captopril in 52 patients with hypertensive emergencies: 25-mg captopril and 10-mg nifedipine were administered sublingually to 28 and 24 patients, respectively. Blood pressures and heart rates were continuously measured up to 240 min postdose. A significant (P less than 0.001) hypotensive effect of both sublingual captopril and nifedipine therapy occurred at 5 min and persisted for 240 min. Heart rates increased with nifedipine, but decreased with captopril. We observed no side-effects in the captopril group, but flushing, tachycardia and headache were observed in 6 patients in the nifedipine group. We conclude that sublingual captopril is effective in patients with hypertensive emergencies and that captopril may be an excellent alternative to sublingual nifedipine in the urgent treatment of hypertensive crisis.


Assuntos
Captopril/uso terapêutico , Hipertensão/tratamento farmacológico , Nifedipino/uso terapêutico , Administração Sublingual , Pressão Sanguínea/efeitos dos fármacos , Captopril/administração & dosagem , Captopril/efeitos adversos , Emergências , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Nifedipino/administração & dosagem , Nifedipino/efeitos adversos
17.
Acta Diabetol Lat ; 19(1): 49-53, 1982.
Artigo em Inglês | MEDLINE | ID: mdl-7072441

RESUMO

Left ventrical performance was assessed by systolic and diastolic time intervals measured echocardiographically in 24 diabetic patients without clinical heart disease and in 18 healthy subjects. It was found that diabetics had longer PEP, higher PEP/LVET ratio and longer IVRT (p less than 0.01). The possible pathogenetic explanations of these abnormalities are discussed and it is concluded that the measurement of time intervals is a useful method for detecting this myocardial dysfunction on the preclinical stage.


Assuntos
Diabetes Mellitus/fisiopatologia , Coração/fisiopatologia , Adolescente , Adulto , Diástole , Eletrocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Sístole , Fatores de Tempo
19.
J Cardiovasc Surg (Torino) ; 21(4): 509-12, 1980.
Artigo em Inglês | MEDLINE | ID: mdl-7419570

RESUMO

Aneurysms of the left atrium or its appendage are uncommon. Some occur with an intact pericardium and others are associated with a pericardial defect. The majority of patients are asymptomatic, but dysrhythmias and systemic embolism may occur. The condition should be suspected after chest radiography but can only be confirmed by angiocardiography. Resection is advised with cardiopulmonary bypass standing by. A patient with an intrapericardial aneurysm of the appendage correctly diagnosed by angiocardiography and successfully treated by simple excision is described.


Assuntos
Aneurisma Cardíaco/cirurgia , Átrios do Coração/cirurgia , Taquicardia Paroxística/etiologia , Adulto , Angiocardiografia , Feminino , Aneurisma Cardíaco/complicações , Aneurisma Cardíaco/diagnóstico , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA