RESUMO
STUDY DESIGN: Descriptive study. OBJECTIVE: This study aimed to develop and evaluate a systematic arrangement for improvement and monitoring of data quality of the National Spinal Cord (and Column) Injury Registry of Iran (NSCIR-IR)-a multicenter hospital-based registry. SETTING: SCI community in Iran. METHODS: Quality assurance and quality control were the primary objectives in improving overall quality of data that were considered in designing a paper-based and computerized case report. To prevent incorrect data entry, we implemented several validation algorithms, including 70 semantic rules, 18 syntactic rules, seven temporal rules, and 13 rules for acceptable value range. Qualified and trained staff members were also employed to review and identify any defect, inaccuracy, or inconsistency in the data to improve data quality. A set of functions were implemented in the software to cross-validate, and feedback on data was provided by reviewers and registrars. RESULTS: Socio-demographic data items were 100% complete, except for national ID and education level, which were 97% and 92.3% complete, respectively. Completeness of admission data and emergency medical services data were 100% except for arrival and transfer time (99.4%) and oxygen saturation (48.9%). Evaluation of data received from two centers located in Tehran proved to be 100% accurate following validation by quality reviewers. All data was also found to be 100% consistent. CONCLUSIONS: This approach to quality assurance and consistency validation proved to be effective. Our solutions resulted in a significant decrease in the number of missing data.
Assuntos
Confiabilidade dos Dados , Traumatismos da Medula Espinal , Escolaridade , Humanos , Irã (Geográfico)/epidemiologia , Sistema de Registros , Traumatismos da Medula Espinal/epidemiologiaRESUMO
BACKGROUND: The National Traumatic Spinal Cord Injury Registry in Iran (NSCIR-IR), was implemented initially in three hospitals as a pilot phase from 11 Oct 2015 to 19 Jun 2016 and has been active in eight centers from 19 Jun 2016. Poursina Hospital, a trauma care referral center in Rasht, Guilan Province of Iran is one of the registry sites, and has been involved in registering eligible patients since 1 Jan 2016. This study aimed to identify the challenges and solutions for sustaining the NSCIR-IR in a regional center. METHODS: This was a mixed-methods study. For the quantitative analysis, a retrospective observational design was used to measure case capture or case identification rate, mapping cases in the registry against those eligible for registry inclusion amongst the register of hospital admissions. For the qualitative component, data was collected using focus group discussions and semi-structured interviews, followed by thematic analysis. RESULTS: From 19 Jun 2016 to 24 Jan 2018, the proportion of case capture (case identification rate) was 17%. The median time between case identification and data entry to the system was 30.5 d (range: 2 to 193 d). Thematic analysis identified a lack of trained human resources as the most important cause of low case identification rate and delay in data completion. CONCLUSION: Recruitment and education to increase trained human resources are needed to improve case capture, the timeliness of data input and registry sustainability in a regional participating site.
RESUMO
STUDY DESIGN: Descriptive study. OBJECTIVES: The aim of this manuscript is to describe the development process of the data set for the National Spinal Cord Injury Registry of Iran (NSCIR-IR). SETTING: SCI community in Iran. METHODS: The NSCIR-IR data set was developed in 8 months, from March 2015 to October 2015. An expert panel of 14 members was formed. After a review of data sets of similar registries in developed countries, the selection and modification of the basic framework were performed over 16 meetings, based on the objectives and feasibility of the registry. RESULTS: The final version of the data set was composed of 376 data elements including sociodemographic, hospital admission, injury incidence, prehospital procedures, emergency department visit, medical history, vertebral injury, spinal cord injury details, interventions, complications, and discharge data. It also includes 163 components of the International Standards for the Neurologic Classification of Spinal Cord Injury (ISNCSCI) and 65 data elements related to quality of life, pressure ulcers, pain, and spasticity. CONCLUSION: The NSCIR-IR data set was developed in order to meet the quality improvement objectives of the registry. The process was centered around choosing the data elements assessing care provided to individuals in the acute and chronic phases of SCI in hospital settings. The International Spinal Cord Injury Data Set was selected as a basic framework, helped by comparison with data from other countries. Expert panel modifications facilitated the implementation of the registry process with the current clinical workflow in hospitals.
Assuntos
Bases de Dados Factuais/normas , Pessoal de Saúde/normas , Qualidade da Assistência à Saúde/normas , Sistema de Registros/normas , Traumatismos da Medula Espinal/epidemiologia , Traumatismos da Medula Espinal/terapia , Bases de Dados Factuais/tendências , Pessoal de Saúde/tendências , Humanos , Irã (Geográfico)/epidemiologia , Qualidade da Assistência à Saúde/tendênciasRESUMO
BACKGROUND: Spinal cord injury (SCI) is one of the most disabling consequences of trauma with unparalleled economic, social, and personal burden. Any attempt aimed at improving quality of care should be based on comprehensive and reliable data. This pilot investigation studied the feasibility of implementing the National Spinal Cord and Column Injury Registry of Iran (NSCIR-IR) and scrutinized the quality of the registered data. METHODS: From October 2015 to May 2016, over an 8-month period, 65 eligible trauma patients who were admitted to hospitals in three academic centers in mainland Iran were included in this pilot study. Certified registered nurses and neurosurgeons were in charge of data collection, quality verification, and registration. RESULTS: Sixty-five patients with vertebral column fracture dislocations were registered in the study, of whom 14 (21.5%) patients had evidence of SCI. Mechanisms of injury included mechanical falls in 30 patients (46.2%) and motor vehicle accidents in 29 (44.6%). The case identification rate i.e. clinical and radiographic confirmation of spine and SCI, ranged from 10.0% to 88.9% in different registry centers. The completion rate of all data items was 100%, except for five data elements in patients who could not provide clinical information because of their medical status. Consistency i.e. identification of the same elements by all the registrars, was 100% and accuracy of identification of the same pathology ranged from 66.6% to 100%. CONCLUSIONS: Our pilot study showed both the feasibility and acceptable data quality of the NSCIR-IR. However, effective and successful implementation of NSCIR-IR data use requires some modifications such as presence of a dedicated registrar in each center, verification of data by a neurosurgeon, and continuous assessment of patients' neurological status and complications.