Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 32(8): 14607-14619, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38859401

RESUMO

X-ray dual-phase grating interferometry provides quantitative micro-structural information beyond the optical resolution through its tunable correlation length. Ensuring optimal performance of the set-up requires accurate correlation length estimation and precise alignment of the gratings. This paper presents an automated procedure for determining the complete geometrical parameters of the interferometer set-up with a high degree of precision. The algorithm's effectiveness is then evaluated through a series of experimental tests, illustrating its accuracy and robustness.

2.
Sci Rep ; 14(1): 384, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172504

RESUMO

The multi-scale characterization of building materials is necessary to understand complex mechanical processes, with the goal of developing new more sustainable materials. To that end, imaging methods are often used in materials science to characterize the microscale. However, these methods compromise the volume of interest to achieve a higher resolution. Dark-field (DF) contrast imaging is being investigated to characterize building materials in length scales smaller than the resolution of the imaging system, allowing a direct comparison of features in the nano-scale range and overcoming the scale limitations of the established characterization methods. This work extends the implementation of a dual-phase X-ray grating interferometer (DP-XGI) for DF imaging in a lab-based setup. The interferometer was developed to operate at two different design energies of 22.0 keV and 40.8 keV and was designed to characterize nanoscale-size features in millimeter-sized material samples. The good performance of the interferometer in the low energy range (LER) is demonstrated by the DF retrieval of natural wood samples. In addition, a high energy range (HER) configuration is proposed, resulting in higher mean visibility and good sensitivity over a wider range of correlation lengths in the nanoscale range. Its potential for the characterization of mineral building materials is illustrated by the DF imaging of a Ketton limestone. Additionally, the capability of the DP-XGI to differentiate features in the nanoscale range is proven with the dark-field of Silica nanoparticles at different correlation lengths of calibrated sizes of 106 nm, 261 nm, and 507 nm.

3.
Opt Express ; 31(24): 40450-40468, 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38041345

RESUMO

The dark-field signal provided by X-ray grating interferometry is an invaluable tool for providing structural information beyond the direct spatial resolution and their variations on a macroscopic scale. However, when using a polychromatic source, the beam-hardening effect in the dark-field signal makes the quantitative sub-resolution structural information inaccessible. Especially, the beam-hardening effect in dual-phase grating interferometry varies with spatial location, inter-grating distance, and diffraction order. In this work, we propose a beam-hardening correction algorithm, taking into account all these factors. The accuracy and robustness of the algorithm are then validated by experimental results. This work contributes a necessary step toward accessing small-angle scattering structural information in dual-phase grating interferometry.

4.
Opt Express ; 31(2): 1677-1691, 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36785198

RESUMO

In this work, we analyze the interference patterns measured in lab-based dual-phase grating interferometry and for the first time explain the spatial dependencies of the measured interference patterns and the large visibility deviations between the theoretical prediction and the experimental results. To achieve this, a simulator based on wave propagation is developed. This work proves that the experimental results can be simulated with high accuracy by including the effective grating thickness profile induced by the cone-beam geometry, the measured detector response function and a non-ideal grating shape. With the comprehensive understanding of dual-phase grating interferometry, this provides the foundations for a more efficient and accurate algorithm to retrieve sample's structure information, and the realistic simulator is a useful tool for optimizing the set-up.

5.
J Imaging ; 8(10)2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36286376

RESUMO

Mineral building materials suffer from weathering processes such as salt efflorescence, freeze-thaw cycling, and microbial colonization. All of these processes are linked to water (liquid and vapor) in the pore space. The degree of damage following these processes is heavily influenced by pore space properties such as porosity, pore size distribution, and pore connectivity. X-ray computed micro-tomography (µCT) has proven to be a valuable tool to non-destructively investigate the pore space of stone samples in 3D. However, a trade-off between the resolution and field-of-view often impedes reliable conclusions on the material's properties. X-ray dark-field imaging (DFI) is based on the scattering of X-rays by sub-voxel-sized features, and as such, provides information on the sample complementary to that obtained using conventional µCT. In this manuscript, we apply X-ray dark-field tomography for the first time on four mineral building materials (quartzite, fired clay brick, fired clay roof tile, and carbonated mineral building material), and investigate which information the dark-field signal entails on the sub-resolution space of the sample. Dark-field tomography at multiple length scale sensitivities was performed at the TOMCAT beamline of the Swiss Light Source (Villigen, Switzerland) using a Talbot grating interferometer. The complementary information of the dark-field modality is most clear in the fired clay brick and roof tile; quartz grains that are almost indistinguishable in the conventional µCT scan are clearly visible in the dark-field owing to their low dark-field signal (homogenous sub-voxel structure), whereas the microporous bulk mass has a high dark-field signal. Large (resolved) pores on the other hand, which are clearly visible in the absorption dataset, are almost invisible in the dark-field modality because they are overprinted with dark-field signal originating from the bulk mass. The experiments also showed how the dark-field signal from a feature depends on the length scale sensitivity, which is set by moving the sample with respect to the grating interferometer.

6.
Sci Rep ; 11(1): 18446, 2021 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-34531486

RESUMO

X-ray computed micro-tomography typically involves a trade-off between sample size and resolution, complicating the study at a micrometer scale of representative volumes of materials with broad feature size distributions (e.g. natural stones). X-ray dark-field tomography exploits scattering to probe sub-resolution features, promising to overcome this trade-off. In this work, we present a quantification method for sub-resolution feature sizes using dark-field tomograms obtained by tuning the autocorrelation length of a Talbot grating interferometer. Alumina particles with different nominal pore sizes (50 nm and 150 nm) were mixed and imaged at the TOMCAT beamline of the SLS synchrotron (PSI) at eighteen correlation lengths, covering the pore size range. The different particles cannot be distinguished by traditional absorption µCT due to their very similar density and the pores being unresolved at typical image resolutions. Nevertheless, by exploiting the scattering behavior of the samples, the proposed analysis method allowed to quantify the nominal pore sizes of individual particles. The robustness of this quantification was proven by reproducing the experiment with solid samples of alumina, and alumina particles that were kept separated. Our findings demonstrate the possibility to calibrate dark-field image analysis to quantify sub-resolution feature sizes, allowing multi-scale analyses of heterogeneous materials without subsampling.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA